CERN Accelerating science

CERN Document Server 2,035 records found  1 - 10próximoend  jump to record: Search took 0.77 seconds. 
1.
CMS Hadron Forward Calorimeter Phase I Upgrade Status / Onel, Yasar (U. Iowa, Iowa City) /for the CMS Collaboration
The Hadron Forward Calorimeter of CMS is going through a complete Phase I upgrade. The current photomultiplier tubes (PMTs) are being replaced with thinner window, higher quantum efficiency, four-anode photomultiplier tubes. [...]
CMS-CR-2014-075.- Geneva : CERN, 2015 - 13 p. - Published in : J. Phys.: Conf. Ser. 587 (2015) 012007 Fulltext: PDF; IOP Open Access article: PDF;
In : 16th International Conference on Calorimetry in High Energy Physics, Giessen, Germany, 7 - 11 Apr 2014, pp.012007
2.
Noise Filter Studies for CMS Forward Hadron Calorimeter (HF) Between Old and New PMT's Using Data in 2012 / Dumanoglu, Isa (Cukurova U.) ; Guler, Yalcin (Cukurova U.) ; Gurpinar, Emine (Texas Tech.) ; Kunori, Shuichi (Texas Tech.) ; Lezki, Samet (Cukurova U.) ; Tali, Bayram (Cukurova U.)
During the data taking before 2012 some abnormal events which have higher signals than expected were observed. Most of these were due to muons. [...]
CMS-CR-2016-355.- Geneva : CERN, 2016 - 6 p. Fulltext: PDF;
3.
CMS Hadron Forward Calorimeter Phase I Upgrade Status / Bilki, Burak (Iowa U.) ; Onel, Yasar (Iowa U.) /CMS Collaboration
The Hadron Forward Calorimeter of CMS is going through a complete Phase I upgrade. The current photomultiplier tubes (PMTs) are being replaced with thinner window, higher quantum efficiency, four-anode photomultiplier tubes. [...]
CMS-CR-2014-117.- Geneva : CERN, 2014 - 5 p. - Published in : PoS: TIPP2014 (2014) , pp. 267 Fulltext: PDF;
In : International Conference on Technology and Instrumentation in Particle Physics 2014, Amsterdam, Netherlands, 2 - 6 Jun 2014, pp.267
4.
Comparison of the Multi-anode PMTs with the old HF PMTs by Studying the Collision Data / Oz, Yavuz
The Hadron Forward (HF) calorimeter of the CMS detector improves jet detection and missing transverse energy resolution in the high pseudorapidity range [...]
CERN-THESIS-2013-084 CMS-TS-2013-019. - 2013. - 58 p.

Fulltext
5.
CMS Hadron Forward Calorimeter Phase I Upgrade Status / Onel, Yasar (Iowa U.) /CMS Collaboration
The Hadron Forward Calorimeter of CMS completed the Long Shutdown 1 part of the Phase I upgrade. Approximately 1800 photomultiplier tubes were replaced with thinner window, higher quantum efficiency, four-anode photomultiplier tubes. [...]
CMS-CR-2015-327.- Geneva : CERN, 2016 - 4 p. - Published in : 10.1109/NSSMIC.2015.7581885 Fulltext: PDF;
In : 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, San Diego, CA, USA, 31 Oct - 7 Nov 2015, pp.7581885
6.
Commissioning of Upgrade Forward Hadron Calorimeters of CMS / Bilki, Burak (Iowa U.) /CMS Collaboration
The CMS experiment at the Large Hadron Collider (LHC) at CERN is upgrading the photo-detection and readout system of the forward hadron calorimeter (HF). During Long Shutdown 1, all of the original PMTs were replaced with multi-anode, thin window photomultipliers. [...]
CMS-CR-2016-417.- Geneva : CERN, 2016 - 5 p. Fulltext: PDF;
In : IEEE Nuclear Science Symposium and Medical Imaging Conference, Strasbourg, France, 29 Oct - 6 Nov 2016
7.
Search for heavy Majorana neutrinos in pp collisions at √s = 8 TeV with the CMS detector & photodetector and calorimeter R&D; for particle colliders / Tiras, Emrah
This thesis contains both physics analysis and hardware studies [...]
CERN-THESIS-2017-362. - 145 p.

Full text - Fulltext - Full text
8.
Phase 1 upgrade of the CMS forward hadronic calorimeter / Noonan, Daniel Christopher (Florida Inst. Tech.) /CMS Collaboration
The CMS experiment at the Large Hadron Collider at CERN is upgrading the photo- detection and readout system of the forward hadronic calorimeter. The phase 1 upgrade of the CMS forward calorimeter requires the replacement of the current photomultiplier tubes, as well as the installation of a new front-end readout system. [...]
CMS-CR-2016-340.- Geneva : CERN, 2017 - 9 p. - Published in : JINST 12 (2017) C02026 Fulltext: PDF;
In : Topical Workshop on Electronics for Particle Physics, Karlsruhe, Germany, 26 - 30 Sep 2016, pp.C02026
9.
Phase I Upgrade of the CMS Hadron Calorimeter / Cooper, Seth Isaac (Alabama U.) /CMS Collaboration
In preparation for Run 2 (2015) and Run 3 of the LHC (2019), the CMS hadron calorimeter has begun a series of ambitious upgrades. These include new photodetectors in addition to improved front-end and back-end readout electronics. [...]
CMS-CR-2014-258.- Geneva : CERN, 2014 - 7 p. Fulltext: PDF;
In : 37th International Conference on High Energy Physics, Valencia, Spain, 2 - 9 Jul 2014
10.
The CMS Hadron Forward Calorimeter Upgrade during Phase I / Gulmez, Erhan (Bogazici U.) /CMS Collaboration
The CMS Hadron Forward Calorimeter will be upgraded during phase 1. The upgrade will include the replacement of the current PMTs with the 4-anode ones and the readout electronics. [...]
CMS-CR-2013-226.- Geneva : CERN, 2014 - 6 p. - Published in : 10.1142/9789814603164_0089 Fulltext: PDF;
In : 14th ICATPP Conference on Astroparticle, Particle, Space Physics and Detectors for Physics Applications, Como, Italy, 23 - 27 Sep 2013, pp.568-572

Haven't found what you were looking for? Try your search on other servers:
recid:1702273 em Amazon
recid:1702273 em CERN EDMS
recid:1702273 em CERN Intranet
recid:1702273 em CiteSeer
recid:1702273 em Google Books
recid:1702273 em Google Scholar
recid:1702273 em Google Web
recid:1702273 em IEC
recid:1702273 em IHS
recid:1702273 em INSPIRE
recid:1702273 em ISO
recid:1702273 em KISS Books/Journals
recid:1702273 em KISS Preprints
recid:1702273 em NEBIS
recid:1702273 em SLAC Library Catalog