Plexiglas Impact Family Data Sheet
Plexiglas Impact Family Data Sheet
Plexiglas Impact Family Data Sheet
A C RY L I C S H E E T
Ever wished you could have a Plexiglas® acrylic sheet product n Improved Toughness
that has more impact resistance and toughness compared to
n Increased Chemical Resistance
standard Plexiglas® MC acrylic sheet? The Plexiglas® IMPACT
Family of acrylic sheet products provides this option! n High Optical Clarity
n Proven Weatherability
Depending on your application needs, there are four levels of
toughness and impact resistance to choose from. Plexiglas® T n Can be easily fabricated and thermoformed
acrylic sheet contains the lowest level of impact modifier. As the
n Thickness range from 0.080” – 0.236”
level of impact modifier is increased, Plexiglas® T2 and Plexiglas®
T3 are offered all the way up to Plexiglas® DR acrylic sheet, which n Colors available upon request
has the highest level of impact modifier throughout the sheet.
SHEET SIZE
The Plexiglas® IMPACT Family of products combines the beauty 48” x 96”
of Plexiglas® MC with added toughness. You no longer have to 60” x 96”
72” x 96”
sacrifice clarity, design flexibility, or fabrication techniques to
get the performance you desire. Custom sizes available
upon request
Plexiglas IMPACT Family
®
1-888-CURBELL
www.curbellplastics.com
ACRYLIC SH E E T
OpTIcal
Luminous Transmittance1 ASTM D-1003 % 92.0 91.0 91.0 90.0
Haze 1
ASTM D-1003 % < 1.5 < 2.0 < 2.0 < 2.5
MEcHanIcal
Tensile Strength, Maximum ASTM D-638 psi 7600 6800 5900 5400
Tensile Strength, Yield ASTM D-638 psi 8600 7900 6500 5600
Tensile Modulus of Elasticity ASTM D-638 psi 405,000 365,000 300,000 250,000
Flexural Strength, Maximum ASTM D-790 psi 14,300 13,000 11,000 9300
Flexural Modulus of Elasticity ASTM D-790 psi 400,000 360,000 310,000 260,000
Notched Izod Impact @ 73°F (23°C) ASTM D-256 ft-lb / in 0.67 0.96 1.23 1.37
Un-notched Charpy @ 73°F (23°C) ASTM D-6110 ft-lb / in 14.2 20.4 25.0 29.5
THErMal
Deflection Temperature under Flexural Load @ 264psi – unannealed1 ASTM D-648 ºF 184 182 174 167
Deflection Temperature under Flexural Load @ 264psi – annealed3 ASTM D-648 ºF 210 207 202 198
Coefficient of Linear Thermal Expansion at 86ºF ASTM D-696 in / in / ºF x 10-5 4.06 4.09 4.91 5.31
Maximum Recommended Continuous Service Temperature N/A ºF 155 - 175 150 - 170 145 – 165 135 - 155
Recommended Thermoforming Temperature N/A ºF 270 - 335 265 - 330 255 - 320 250 - 315
craZE rESISTancE4
Constant Stress Craze Resistance, IPA MIL-PRF-8184F psi 1750 1800 1850 2600
Constant Stress Craze Resistance, Acetone MIL-PRF-8184F psi 600 650 700 1050
Plastics Component – QMFZ2.E39437 Outdoor Suitability f1 (≥ 0.060” clear) f1 (≥ 0.060” clear) f1 (≥ 0.060” clear)
UL 746C N/A ---
f2 (≥ 0.060” ALL) f2 (≥ 0.060” White) f2 (≥ 0.060” White)
Plexiglas® acrylic plastic is a combustible thermoplastic. Observe fire precautions appropriate for comparable forms of wood and paper. For building uses, check code approvals.
Impact resistance is a factor of thickness. Avoid exposure to heat or aromatic solvents. Clean with soap and water. Avoid abrasives.
altuglas International
The statements, technical information and recommendations contained herein are believed to be accurate as of the date hereof. Since the conditions and methods of use of the product
Arkema Inc.
and of the information referred to herein are beyond our control, Arkema expressly disclaims any and all liability as to any results obtained or arising from any use of the product or reliance
on such information; NO WARRANTY OF FITNESS FOR ANY PARTICULAR PURPOSE, WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR
100 PA Rt. 413
IMPLIED, IS MADE CONCERNING THE GOODS DESCRIBED OR THE INFORMATION PROVIDED HEREIN. The information provided herein relates only to the specific product
designated and may not be applicable when such product is used in combination with other materials or in any process. The user should thoroughly test any application before com
Bristol, PA 19007
mercialization. Nothing contained herein constitutes a license to practice under any patent and it should not be construed as an inducement to infringe any patent and the user is advised TEL 800.523.7500
to take appropriate steps to be sure that any proposed use of the product will not result in patent infringement.
FAX 215.826.2698
ROC, 3/13, 400