Congratulations on the purchase of your DOMONIAL security system. This system is designed to operate on an authorised radio frequency and will in no way endanger the user. To make the best out of your system we advise you to read this manual carefully. This manual has been written for your special attention and integrates remarks and suggestions of existing users. Full set Part set Annex
Zone 1 : Zone 2 : Zone 3 : Zone 4 : Zone 5 : Zone 6 : Zone 7 : Zone 8 : Zone 9 : Zone 10 :
Zone 11 : Zone 12 : Zone 13 : Zone 14 : Zone 15 : Zone 16 : Zone 17 : Zone 18 : Zone 19 : Zone 20 :
INDEX
4 6 8 12 15
1
4 7
2 5 8 0
3 6 9
SOS
The Domonial control panel/communicator unit is the brain of your security system. It exchanges information with the associated wireless peripherals. The control panel centralises the data sent by the detectors, records the arming and disarming operations and communicates with the Alarm Receiving Centre.
CHARACTERISTICS
Radio G Narrow band frequency modulation G Identification code specific to each component (no possible interference between neighbouring systems) G Protection against attempted jamming G Radio monitoring of the system detectors and sounders
Electrical G 240V mains with battery backup G Built-in voltage surge protection G System supply monitoring
Transmission G Built-in telephone transmission G Telephone line loss detection G Transmission monitoring by periodical tests (as programmed)
Operational G 3 protected area groups - 20 detection points G Alert functions, with sounder or silent G All door and window contacts, closed position checked upon arming G Control panel tamper protection against opening
Indicator lights
The front cover of the control panel features LED indicators which show the status of your security system.
ON : It indicates a fault on a technical channel or a remote reset is required BLINKING : It indicates a fault on the system ( Battery fault, Supervision, Tamper, Phone line failure or Radio Jamming ) The indicator will remain ON or BLINKING until the condition has been cleared.
2 1
When Arming, confirms that the control panel has received the information.
Duration : 4 seconds
When Disarming, confirms that the control panel has received the information.
2 times 7 fast beeps FAULT signal This signal indicates a fault in the system
Upon arming... Exit delay confirmation one beep every second Upon entry... Entry delay one beep every second This entry tone sounds for 30 seconds after you open the entry door. You should disarm your system within this time. This will sound until five second after the exit door is closed
1
4
2 5 8 0
3 6 9
SOS
The keypad is used to arm and to disarm your security system by means of an access code chosen at the installation stage.
1
4 2 5 8 0 3 6 9
To use all the functions of the keypad you must have the master code chosen at the installation stage or have the master key tag.
SOS
A green light on the keypad confirms that the TAG has been accepted. The audible confirmation tone is simultaneously emitted by the sounder at this moment remove your key TAG
1
4 7
2 5 8 0
3 6 9
SOS
The keypad confirms the code with a flashing red light, - The audible confirmation emitted by the sounder. is simultaneously
Always make sure that when arming the system it is followed by the audible confirmation. Premises will be armed after you have closed the exit door (full set) or after 30 seconds (part set).
Your system is equipped with a TAG Reader, presenting the TAG in front of the keypad can take the place of entering your code.
Presenting the TAG for more than 2 seconds will arm your system.
If the red LED is illuminated on your alarm panel, this indicates an alarm has occured in one zone only and the system will not operate until it has been reset.
1
4 7
2 5 8 0
3 6 9
SOS
To reset the system follow the disarming procedures using either your code or keytag four times consecutively. Ensure the audible disarm tone sounds after each disarming procedure.
If the two red LEDs are illuminated on your alarm panel, this indicates a confirmed alarm has occured and a remote reset is required and the system will not operate. To remotely reset your system call your Service Department :
simultaneously
The red light will flash slowly Enter the 4 digit master code (user 1) Select and enter an existing or new single digit user ID (0-9) (N.B. : User 1 is always the master) Enter the new 4 digit code for this user A double beep on the keypad will confirm acceptance of the new code. You must confirm the new code by re entering the 4 digits numbers. A double beep on the keypad will confirm acceptance of the new code. Exit programming mode by pressing key.
simultaneously
10
1
4 7
2 5 8 0
3 6 9
SOS
Enter the 4 digit master code (user 1) Select and enter an existing digit user ID (0-9) Present the new key TAG A double beep on the keypad will confirm acceptance of the new TAG. Exit programming mode by pressing key.
WARNING : The system will automatically exit programming mode after 15 seconds if no keys have been pressed and the red light will be timed off. If this occurs you must start this process again from the beginning.
G ENTRY DELAY
The entry delay gives you the time necessary to enter your access code or use your key TAG on the keypad to disarm your security system.
11
The keyfob is an optional extra. This can be used to arm or disarm your security system as well as to trigger an audible or silent alert.
G ARMING
Press key :
The indicator light on the keyfob comes on briefly when you release the button - An audible confirmation is simultaneously emitted by the signaling equipments.
Always make sure that your arming the system is followed by the audible confirmation. N.B. Arming and disarming can only be operated whilst inside the premises. If, upon arming, a door or window contact is in the "open" position (e.g. window not properly shut), a FAULT signal will inform you. Disarm the system, shut the corresponding window and repeat arming.
The indicator light on the keyfob comes on briefly when you release the button. - The audible confirmation signaling equipment. is emitted by the
N.B. This function can only be used when the entry route delay has been triggered.
12
Provided that this function has been programmed by the installer, you can choose to protect only a part of your premises whilst you are in the other part. For instance, you can protect the ground floor while your are sleeping upstairs. Press key
The indicator light on the keyfob comes on when you release the button.
is simultaneously
Part protection becomes effective 30 seconds after you have armed it. Any intruder in the protected zone will trigger an alarm. Part set is disarmed by pressing the key.
G PANIC ALARM
These keys enable you to send an instant alarm if you need urgent assistance at home.
Press and hold the two SOS keys simultaneously for two seconds.
+
The indicator light comes on.
13
The PANIC function is operative even when your system is not armed. The sounder stops by itself after 30 second but you can stop it manually by pressing
Stopping the sounder does not interrupt the transmission to the ARC station.
Press key :
14
G Check regulary your system (once a month or follow your operators specifications)
G Avoid shocks for all the components and more especially avoid dropping the remote keyfob.
G Do not immerse.
G Do not try to open or move the components. They are tamper-protected and some of them can present electric shock hazards.
15