PW8 User Manual
PW8 User Manual
PowerWave-8
8 zone Control panel Communicator
Version: 8.69
May 2003
Contents
Introduction ............................................................................................. 5
Meet the Crow Alarm Control System ...........................5 Typical Alarm System Configuration ............................5
Keypad Description ................................................................................. 5
Function Keys.................................................................5 Alphanumeric Keys ........................................................6 Audible Signals ..............................................................6 Indicators ........................................................................7 Summary of Functions ...................................................7
Operation ................................................................................................ 8
How to Arm the System before Exit ..............................8 How to Arm the System when Staying Home................9 How to Arm Partitions..................................................10 How to Bypass Zones...................................................10 How to use Chime (If enable by Installer) .........................10 Emergency Alerts .........................................................11 Generate Threat or Duress............................................11 How to Read System Messages....................................11 How to Read Trouble Messages...................................12 How to Display Events from Memory .........................12 How to Control Outputs and Devices...........................13 How to Get into to User Program/Client Mode............14 How to Change or Add Codes......................................14 How to Change Master Code .......................................14 How to Add or Change User Code...............................15 How to Delete User Code.............................................15 How to Add or Change Telephone Numbers ...............15 3
How to set Time and Date ............................................15 How to operate the access control output .....................16 How to start Walk test Mode........................................16 How Remote command control works .........................16
Warranty ...................................................................18
Introduction
Meet the Crow Alarm Control System
Thank you for choosing to protect your premises with a PowerWave-8 of Crow Electronic Engineering Ltd. PowerWave of Crow Electronic Engineering Ltd. is a highly advanced, multifunction alarm control system, designed to flawlessly manage your security system at home or at business, protects you against burglary and supports the operation of electronic devices.
Keypad Description
The LED Keypad shows all the information required to operate the system . The User communicates with the alarm system via the keypad. The Keypad displays continuous information about the status of the alarm system, and enables the User to operate the system in different modes, change settings and program Users' access codes. The keypad also collects and records events to be displayed afterward on request, to overview system activities, and to analyze system performance for diagnostics.
Function Keys
These keys are used to arm the system, enter commands to alter system settings, or scroll through the history events. ARM , STAY , BYPASS , PROGRAM ,CONTROL , MEMORY , PANIC , ENTER
1 2 3 4 A
5 6 7 8 B
L TRO C ON
MEMORY
PAN IC
ARM
1 4 7 0
2 5 8
3 6 9
STAY
BYPASS
PROGRAM
ENTER
Alphanumeric Keys
These keys are used to enter codes, Initiate Emergency or for programming.
Audible Signals
The keypad emits signals (beeps) in response to User activities. These signals are listed in Table. Table: List of Audible Signals Sound Short beep 3 short beeps Long beep Slow beeping Sequence Once only Once only Once only Through the Exit or Entry delay time Description A key in the keypad has been pressed Operation carried out successfully Illegal operation, or wrong key pressed Exit or entry delay warning when arming the system indicates that you must exit the protected area, also Entry delay warning when entering via the entry zone, to disarm the system.
Indicators
There are 14 LEDs indicators show the status of the system. Zone and Status indicators LEDs 1- 8 Partitions indicators LEDs A, B Ready Byp indicator System indicator, Trouble indicator Program indicator .
Summary of Functions
The system's main functions are listed in table
Function Full or Partition Arm Full Arm Disarm during exit Disarm Arm Stay
Keys
Description
ENTER
Notes
! CODE ! ! !
ARM
Only if enabled by installer Only when slow beeping is emitted Stopping Alarms Only if enabled by installer
ARM
! CODE ! ! ! !
STAY ENTER
Disarms the system Initiates partial alarm when the user is home Initiates partial alarm when the user is home
! CODE
Arm Stay
STAY
! CODE ! ! ! ! ! !
STAY
BYPASS
ENTER
! Zone #
Bypasses a zone(s)
ENTER
PANIC
Keys
Description
Notes Only if enabled by installer Only if enabled by installer Displays events, and automatically scrolls to the next event every 2.5 sec. (Use <MEMORY> key to scroll up manually) Only if enabled by installer Press <Control> for 2 seconds
! ! !
+ +
Activates emergency alert Activates emergency alert Initiates display of events from memory. <ENTER> cancels memory readout
4
MEMORY
! ! ! ! !
CONTROL
! !
PROGRAM
Enable or disable chime function Activates or deactivates outputs and devices Activates program mode to add or change Users' codes
CONTROL
Device#
ENTER
PROGRAM
! M CODE
ENTER
Note:
If you started an operation incorrectly, press <ENTER> to exit and return to the previous mode.
Operation
How to Arm the System before Exit
Preparing the System for Arming Verify that the green <Ready Byp> indicator is lit .This indicator is lit only when all zones are closed (all doors, exits and windows are closed and motion in the protected area is restricted or bypassed) , the system is ready to be armed. If the green <Ready Byp > indicator is not illuminated, the zone LED 1 to 8 is lit displays the open zones . Close open zones, or bypass them. Bypass any zone you cannot close , the <Ready Byp> indicator flashes indicating bypassed zone(s) . For details see page 9. Note: Bypassed zones are not protected. Arming the System
Before leaving premises the system has to be armed. When the system is Ready , indicator is lit , enter user code and then <ENTER> to arm the system. There is a exit delay prior to the system being armed. During this delay time, a slow beeping is heard to indicate that the system is not armed yet and reminds you to leave the protected area. The A indicator lights up to indicate that the system is armed. (The indicators may go out few seconds after exit delay expired , depending on the installer's setting). If you must disarm the system during the exit delay, press <ARM>. Quick Arm (When enabled by the installer)
When the system is Ready , press <ARM> to arm the system. The A indicator lights up to indicate that the system is armed. During exit delay time, a slow beeping is heard to indicate that the system is not armed yet and reminds you to leave the protected area..
Enter Users code and press <ENTER>. The A indicator goes off to indicate that the system is disarmed. Stopping Alarms
In case of alarm condition , Enter Users code and press <ENTER> to stop alarm any time.
During exit delay you can leave the premises. If you wish to stay or that no one will enter the protected premises, you may cancel the Entry/exit delay by pressing the <ENTER> key. The slow beeping stops and the system is immediately armed. The A indicator flashes to indicate that the system is armed in stay mode . (The indicators may go out a few seconds after exit delay expired , depending on the installer's setting).
Enter users code and press <ENTER>, or press <STAY> if enabled by installer. The A indicator goes off to indicate that the system is disarmed.
10
Emergency Alerts
LED # 1 LED # 2 LED # 3 LED # 4 Battery Low Mains Failure Telephone Line Failure Radio Detector Battery Low LED # 5 Radio Pendant Battery Low LED # 6 Supervised Detector Failure LED # 7 Zone Inactivity Timeout LED # 8 Dialer Kiss-off Failure
This special keys function is best programmed by your installer to suit your individual situation. Most commonly it is used in a panic situation to sound only the outside siren and perhaps call a monitoring station. How to initiate Panic
Press the <PANIC> or Press simultaneously <1>and <3> . How to initiate Medical Alarm
11
the 127 historical memory events starting at the most recent event. The second table shows the alarm events that can be displayed in memory mode and what indicators are used to show them. The system will display the last event and automatically scroll to the next one every 2.5 seconds, and a beep is emitted. Use the arrow keys to scroll up manually. Wait until all messages are displayed, or press <ENTER> to cancel memory readout.
EVENT TYPE
DEVICE
INDICATOR
STATUS
ACTIVATION BYPASS
On Steady On Steady On Steady Flashing On Steady Flashing On Steady Flashing On Steady On Steady On Steady On Steady Flashing
DETECTOR TAMPER (SHORT CIRCUIT) DETECTOR TAMPER (OPEN CIRCUIT) CABINET TAMPER LOW BATTERY
Zones 1-4
Zones 5-8
MAINS FAILURE
12
PANIC BUTTON (or BUTTONS 1&3 PRESSED TOGETHER) FIRE ALARM (BUTTONS 4&6 PRESSED TOGETHER) MEDICAL ALARM (BUTTONS 7&9 PRESSED TOGETHER) PENDANT PANIC
Keypad Panic
System
Keypad Fire
System AREA A
Flashing Flashing Flashing Flashing Flashing Flashing On Steady On Steady Flashing Flashing On Steady Flashing On Steady Flashing Flashing On Steady On Steady On Steady On Steady On Steady
Keypad Medical
System AREA B
System LED 1-8 AREA A AREA B AREA A AREA B Trouble AREA A & B
Area A is Armed Area B is Armed Area A STAY Mode ON Area B STAY Mode ON Duress Alarm
Zones 1-8
Trouble LED 3
13
To exit out of program mode press <PROGRAM> and <ENTER>. The Program indicator goes off to indicate that the system is not in User programming mode.
14
15
Press <PROGRAM> <405> <ENTER> <1-31> <ENTER> Where 1-31 = the current date Press <PROGRAM> <406> <ENTER> <1-12> <ENTER> Where 1-12 = the current month Press <PROGRAM> <407> <ENTER> <YY> <ENTER> Where YY = current year, e.g. 02=2002
16
operations whereas the DTMF board provides tones (one Long Tone for ON or three short beeps for OFF). Please talk to your installer to find out if all or any of these options are available on your alarm. To perform any of the Command Control features you must first ring the phone number, which the panel is connected to. The panel may be set up to answer after a specific number of rings of it may be set-up to use a fax defeat option. Either way, when you ring the phone number and the panel answers the call, the first thing you will hear over the phone is a burst of modem tone for two seconds. After this tone has stopped you must enter the access code, which is associated with the Command menu option you wish to access. Remember, the code you enter will determine which menu option you access. If you miss the pause, the panel will repeat the modem tone and then again pause for 5 seconds looking for your access code. This process will be repeated 4 times before hanging up if no valid code is received. When entering codes or other information in Command Control the "#" key acts as a "Clear" button.
When you have entered the required 4-digit access code the panel will reply with the status message associated with the Command Control function you have accessed. For example, lets say we have a code of 2045 to allow Arming & Disarming of Area A. Once the code 2045 has been received the panel checks the current status of Area A and replies with the pre-programmed voice message relating to that status e.g. if Area A is Armed then the Armed message will be sent, if Disarmed then the Disarmed message will be sent. If only the DTMF board is fitted, the voice message is substituted with a long beep if Area A is Armed, and three short beeps if it is disarmed. Once the status message has informed you of the actual state, you can use the "*" key to toggle the option on & off or Arm and Disarm, e.g. in our example above, code 2045 accesses Area "A" arming or disarming. Assuming the status message we received was "Area A alarm is Armed" If we press the "*" key, Area "A" will be Disarmed and we would receive a status message "Area A alarm is Disarmed" (or whatever message is programmed by the installer) While you are on-line with the panel you can move between menu options by entering the code of the option you want to control. Assuming there was a code of 4321 programmed to control outputs. After having used code 2045 to control the Arm/Disarm status of Area A we first press the # button to reset all previous entries. Then we can enter the digits 43215 (that is 4321 as the code to control outputs and 5 to select output #5). The current status of output #5 will be given either by the voice message or the appropriate tone and then the status can be changed with the * button on the remote telephone (Note; For output control you must enter in the 4 digit code e.g. 4321 followed by the output number you wish to control, in this case 5). At any stage, if you enter in an incorrect code you can press the # button on the remote telephone to clear all code entries and then start again.
To turn on the optional Microphone (only available if the Voice Board is fitted) you must enter in the appropriate code followed by the * button. To turn the Microphone off you simply press the * button again. To end a Command Control session simply hangs up the phone. The panel is monitoring the line at all times and 15 seconds after the last key press it will automatically hang up the line. This 15-second timer is active during the whole command control process so a period of 15 seconds without a key press will cause the panel to hang-up.
17
Warranty
CROW LIMITED WARRANTY (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose numbers are printed on the printed circuit board inside his product. Crows obligation is limited to repairing or replacing this product, at its option, free of charge for materials or labor, if it is proved to be defective in materials or workmanship under normal use and service. Crow shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other then Crow. There are no warranties, expressed or implied, of merchantability or fitness for a particular purpose or otherwise, which extend beyond the description on the face hereof. In no case shall Crow be liable to anyone for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever, even if the loss or damage is caused by Crows own negligence or fault. Crow does not represent that this product can not be compromised or circumvented; that this product will prevent any person injury or property loss or damage by burglary, robbery, fire or otherwise; or that this product will in all cases provide adequate warning or protection. Purchaser understands that a properly installed and maintained product can only reduce the risk of burglary, robbery or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result. Consequently, Crow shall have no liability for any personal injury, property damage or any other loss based on claim that this product failed to give any warning. However, if Crow is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, Crows maximum liability shall not in any case exceed the purchase price of this product, which shall be the complete and exclusive remedy against Crow.
18
Use the following form to record your changes and customizations. User Name Out Device Designation Zone Zone Name
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
www.thecrowgroup.com
19