0% found this document useful (0 votes)
178 views25 pages

GSM Alarm System

This document provides a user manual for a GSM alarm system. It includes the following key information: 1. The alarm system has an LCD screen, touch keypad, supports wired and wireless defense zones, remote controllers, alarm calls to preset phone numbers, and SMS alerts. 2. It allows for arming and disarming in different modes, recording of alarm events, and programming of zone settings. 3. The manual provides instructions on how to initialize the system, add or delete remote controllers and sensors, set zone properties like the alarm type and delay times.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views25 pages

GSM Alarm System

This document provides a user manual for a GSM alarm system. It includes the following key information: 1. The alarm system has an LCD screen, touch keypad, supports wired and wireless defense zones, remote controllers, alarm calls to preset phone numbers, and SMS alerts. 2. It allows for arming and disarming in different modes, recording of alarm events, and programming of zone settings. 3. The manual provides instructions on how to initialize the system, add or delete remote controllers and sensors, set zone properties like the alarm type and delay times.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 25

MOBILE CALL

GSM Alarm System

USER’S MANUAL

Profile
For a better understanding of this product, please read this user manual thoroughly
before using it.

1
Chapter 1.features
★ Thank you for your choose and buy from shenzhen joann electronic technology
co., LTD. Producer of touch screen GSM alarm.
Elegant and advanced touch keypad for easy operation;
★ 128*64 lattice LCD screen with clock display;
★ 2 wired and 10 wireless defense zones; each wireless zone supports maximum
10 sensors;
★ Support maximum 50 remote controllers;
★ With built-in alarm, doorbell function(optional);
★ Built-in high—volume speaker, and artificial intelligent digital voice
announcer;
★ Built-in artificial intelligent English message;
★ Can preset 5 phone number, when alarming, system will make audio call to
these numbers automatically;
★ can preset 5 SMS numbers: when alarming, system will send SMS;
★ Timely arm and disarm;
★ Can be used as a wireless telephone by using keypad to make calls;
★ One-key-control: out arm, home arm, arm by remote controller or phone call;
★ SOS, fire, gas, door, hall, window, balcony, and boundary places alarm;
★ Real-time,delay,24 hours zones programming function;
★ Wireless learning code: easy to add additional wireless accessories;
★ Remote control the device to arm, disarm, monitor, and intercom by phone;
★ Record checking: the device can store 200 alarm records;
★ Different arm status: out arm, home arm, delay arm and timely arm;
★ Arm by different ways: panel keypad, remote controller, remote call;
★ Alarm call has the priority: even when the number or the device is busy;
★ Built-in LI battery; automatically recharge;

2
Chapter2.Alarm Host Introduction

1. LCD screen:resolution:128*64;support English and Chinese display;


2. Status LED
★Light is on at normal status;
★Light flashes every 8 seconds when utility
failure ★Light quickly flashes when alarming
3. Touch keypad: this keypad is Capacitive Touch
: Press it: the system will enter OUT ARM status.

: Press it: the system will enter HOME ARM status.

: Used to make call, enter the number you want to call, and then press this
button, Press it during the phone call will hang up the call.
SOS: Emergency alarm.

3
ESC: Clear the input content or back to last operation.

OK: Confirm.

0+0+OK: Alarm record query.

1. Fixation insallation area


2. Wired Interface: Z1 Z2 GND: Wired zone. AMP+ AMP-: Wired siren.
3. Microphone area
4. Switch for Spare battery
5. Protection switch(Pressing for 10 seconds)
6. SIM card slot: Please pay attention to the direction arrow marked on the slot:
“LOCK” ”OPEN”. Do not insert or take out the SIM card when the main unit is
power on.
7. Speaker
Chapter3.Initialization
Correct initiation of the main panel is important to its normal working and lifespan.
1. Connect the wired accessories that you need.
2. Insert SIM card.
3. Installing 12v power, main engine comes to self inspecting status. check the
SIM card and information signal on the screen in 15 seconds .The SIM card icon
show ”X” when the SIM card is in abnormal status. Need to re-start if the SIM

4
card status and information signal is abnormal.
4. Turn on the battery switch.
5. Check the GSM signal icon on the LCD screen. Signal less than 3 lattice will
affect the normal performance. Please put the main panel at the place with good
GSM signal.
Chapter4. System Settings
1. Enter settings
All the settings have to be done in setting status. Press 2/8/4/6 to turn
up/down/left/right.
Enter setting status: in the state of disarm, input 6-digit password (system default:
888888), and then press “ok”, the screen shows remote controller setting.
Fig1: disarm status Fig2:please enter password Fig3:press “ok” to set

2. Add Remote Controller


This device supports maximum 50 remote controllers. Extra remote controllers
have to be coded to the host in order to perform normally. Their code cannot be
empty or the same with the saved code in the host.
Method: enter remote controller setting menu, press “4”or “6” to choose remote
controller serial number, press “8” to find “coding” and then press “ok” to confirm.
Trigger the remote controller you want to add. The panel will make two beeps after
receiving it. And then press “ok” to confirm. If the remote controller has been
saved before, after triggering it, the main unit will make four beeps and LCD screen
display “Error, Repeated code”.
Operation figures:
Fig1: enter remote control menu Fig2: choose remote control serial Fig3: waiting to receive signal
number and coding menu

5
Fig4A; recognize successfully Fig4B: the host has the same code Fig5: press “ok” to save with
remote controller code

3. Delete Remote Controller


If the remote controller is lost or damaged, it should be deleted. After deletion,
it cannot control the main panel.
Method: enter remote controller setting menu, press “4” or “6” to choose the
remote controller you want to delete. Press “8” to find “delete”, and then press
“ok”.
Operation figures:
Fig1: enter remote controller Fig2: choose the controller you Fig3: press “ok” to confirm
setting want to delete

4. Coding of Defense Zone


This alarm system has 10 wireless defense zones, each of which supports up
to 10 wireless detector, Extra sensors not in the standard package have to be

6
coded to the host in order to perform normally. Their code cannot be empty or
the same with the saved code in the host.
Method: enter defense zone setting menu, press“4” or“6” to choose zone
number, press “8” to find “coding” and the press “ok” to confirm. Trigger the
sensors you want to add, the panel will make two beeps after receiving it. And
then press “ok” to confirm. If the sensor has been saved before, after
triggering it, the main unit will make four beeps and LCD screen display
“Error, Repeated code”.
Operation figures:
Fig1: enter defense zone setting Fig2: choose zone number and Fig3: waiting signal from sensor
Pressok”

Fig 4A: recognize successfully Fig 4B:the host has the same Fig 5:press”ok” to save
code with sensor code

5. Delete Defense Zone


The wireless detector can’t control the main unit after it’s deleted
Method: enter defense zone setting menu: enter defense zone setting menu,
press “4”or “6” to choose the sensor you want to delete. Press “8” to find
“delete”, and then press “ok”.
Operation figures:
Fig1: enter defense zone setting Fig2: choose zone number Fig3: choose Delete and press “ok”

7
6. Defense Zone Place Setting
The location of defense zone can be set in the main panel, so that the panel can send
correspondent alarm message. There are 8 locations for alarm: SOS, fire, gas, door,
hall, window, balcony, and boundary. Please refer to “Chapter6.Technical
Parameters” for system default settings.
Method: enter defense zone setting menu, press”4” or “6” to choose the zone
number, and then press “2” or “8” to enter zone place menu. Press “ok” will shift
the places.
Operation figures:
Fig1: enter defense zone setting Fig2: choose defense zone place Fig3: press “ok” to confirm

Fig4: (this example)


Before setting, the alarm SMS for zone 1 is: 01 zone fire alarm;
After setting, it is: 01 zone gas alarm.
The format of alarm SMS: [01-10] zone [place] alarm. For example, you set the place of zone 4 as
“window”. The alarm SMS you receive is; 04 zone window alarm.
7. Defense Zone Mode Setting
There are different defense zone modes: Gener; Home; 24hour. For example,
you need gas detectors working all the time, please set 24hour.
Method: enter defense zone setting menu, press “ok” choose “Gener, Home,
24hour”.
Operation figures:
Fig1: enter defense zone setting Fig2: choose mode Fig3: pres “ok” to confirm

8
Fig4: (this example)
Before setting, zone 1 alarm in out arm status.
After setting, it will alarm when triggered in home arm status.
8. Siren Setting for Alarm
The siren can be set on or off when there’s alarm from each defense zone.
Method: enter defense zone setting, press “2” or “8” to choose siren enable or
disable.
Operation figures:
Fig1: enter defense zone setting Fig2: choose siren status Fig3: press “ok” to confirm

Fig4: (this example)


Before setting, the siren is on when zone 1 alarms.
After setting, siren will not sound when zone 1 alarms.
9. Alarm Delay Setting
Alarm delay: the main panel will make alarm call and the siren will ring after
the presser delay time.
Method: enter defense zone setting, press “2” or “8” to choose delay enable or
disable.
Operation figures:
Fig1: enter defense zone setting Fig2: choose delay status Fig3: press “ok” to confirm

9
Fig4: (this example)
Before setting, the panel makes alarm and the siren rings immediately when zone 1 is triggered.
After setting, alarm will be after the preset time. (set the delay time under system setting).
10. Alarm Number Setting
This system can store 5 alarm phone numbers. When alarming, it will make
alarm call to these numbers in order for three times automatically until
someone gets through the call.
Method: enter phone number setting menu, press “4” or “6” to choose serial
number and the press “ok”. Input the number you want to set, then press “ok”
to save.
Operation figures:
Fig1: enter phone number setting Fig2: choose serial NO. Fig3: input phone number

st
Fig4: press “ok” to save Fig5: the 1 number is set successfully

11. Delete Alarm Number


Method: enter phone number setting, press”4’or”6”to choose serial number,
then press”8”to choose “delete” and then press “ok” to confirm.
Operation figures:
Fig1: enter phone number setting Fig2: choose the number you Fig3: choose “delete”
menu want to delete

10
st
Fig4: the 1 number is deleted

12. SMS Number Setting


The system can store 5 SMS receiving phone numbers. When alarming, it will
send SMS to these numbers.
Method: enter SMS number setting, press “4” or “6” to choose serial number
and then press “ok”. Input the number you want to set, then press “ok”to
confirm.
Operation figures:
Fig1: enter SMS number setting Fig2: choose serial number and Fig3: input SMS receiving number
Press “ok’

Fig4: press “ok” to save

13. Delete SMS Number


Method: enter SMS number setting, press”4” or”6”to choose serial number,

11
then press”8’to choose “delete” and then press “ok” to confirm.
Operation figures:
Fig1: enter SMS number setting Fig2: choose the number you Fig3: choose “delete” want to
delete

st
Fig4: the 1 number is deleted

14. System Date Setting


This date format is year/month/day. (“Year” setting is from 00-99)
Method: enter “Time” menu, and then choose “Date”. Input the exact date
you want to set and press “ok” to confirm.
Operation figures:
Fig1: enter time setting menu Fig2: choose date setting menu Fig3: input the date

Fig4: press “ok” to save

12
15. System Time Setting
Time in this alarm system is 24-hour system. Enter “Time” menu, you will see
“Date” menu, then press “6” to choose “Time”. Input the exact time you want
to set and press “ok” to confirm.
Operation figures:

Fig1: enter time setting menu Fig2: you’ll see date setting menu Fig3: press “6” to choose “time”

Fig4: input the time Fig5: press “ok” to save

16. Timely Arm Setting


After this setting, the alarm system will start arm status at the preset time.
Method: enter “Time” menu, you will see “Date” menu, then press “6” to
choose “Timely arm”. Input the exact time you want to set and press “ok” to

13
confirm.
Operation figures:
Fig1: enter time setting menu Fig2: you’ll see date setting menu Fig3: press“6”to choose “timely arm”

Fig4: input the time you want to set

17. Timely Disarm Setting


After this setting, the alarm system will disarm automatically at the preset
time.
Method: enter “Time” menu, you will see “Date” menu, then press “6” to
choose “Timely disarm”. Input the exact time you want to set and press “ok”
to confirm.
Operation figures:
Fig1: enter time setting menu Fig2: you’ll see date setting menu Fig3: press“6”to choose ”timely
disarm”

Fig4: input the time you want to set

14
18. Change Operate Password
Operate password is used for daily use (disarm or remote control).System
default is 1234
Method to change this password: enter “settings” menu, and then “operate
password”. Input the 4-digit password you want to set, and save it.
Operation figures
Fig1: enter setting menu Fig2: enter operate password Fig3: input the 4-digit password
menu

Fig1: save it

19. Change Program Password


Program password is used to setup the system. System default is 888888.
Method to change this password: enter “settings” menu, and then “operate
password”, press “6” to choose “program password”, Input the 6-digit
password you want to set, and save it.
Operation figures:
Fig1: enter setting menu Fig2: you’ll see “Operate Fig3: press “6” to choose
password” menu program password

15
Fig4: input password and save it

20. Arm Delay Time Setting


After this setting, the system will enter out arm status after the preset time.
Delay time ranges from 01-99 seconds. The system default time is 60 seconds
Method: enter “settings” menu, then you’ll see “operate password”. Press “6”
to choose “delay arm”. Input the time you want to set and save it.
Operation figures:

Fig1: enter setting menu Fig2: you’ll see “Operate Fig3: press “6” to choose
password” menu “delay alarm

Fig4: input time and save it

21. Alarm Delay Time Setting

16
After this setting, when there’s an alarm, the system will make call after the
preset time. Delay time ranges from 01-99 seconds. The system default time is
40 seconds
Method: enter “settings” menu, then you’ll see “operate password”. Press “6”
to choose “delay arm”. Input the time you want to set and save it.
Operation figures:
Fig1: enter setting menu Fig2: you’ll see “Operate Fig3: press “6”to choose
password” menu “delay alarm

Fig4: input time and save it

22. Voice Prompt Function


This main panel has voice prompt function. When user press arm or disarm of
the remote controller, it will give voice prompt. System default for the prompt
is on. Users can set it according to actual needs.
Method: enter “settings” menu, then you’ll see “operate password”. Press “6”
to choose “voice prompt” and choose “enable” or “disable”.
Operation figures:
Fig1: enter setting menu Fig2: you’ll see “operate Fig3: press “6” to choose
password” menu “voice prompt”

Fig4: choose enable/disable

17
23. Siren Prompt for Remote Controller
Turn on this function, the siren will sound a short beep each time you press the
remote controller. System default is off.
Method: enter “settings” menu, and then you’ll see “operate password”. Press “6”
to choose “siren prompt” and choose “enable or “disable”.
Operation figures:
Fig1: enter setting menu Fig2: you’ll see “operate Fig3: press “6” to choose
password” menu “siren prompt”

Fig4: choose enable/disable

24. Siren Setting in “Emergency Help” mode


System default is that when you press the emergency button of the remote
controller, the siren does not ring. Users can set it according to the actual
needs.
Method: enter “settings” menu, and then you’ll see “operate password”. Press
“6” to choose “remote siren” and choose “enable” or “disable”.
Operation figures:
Fig1: enter setting menu Fig2: you’ll see “operate Fig3: press“6”to choose

18
password” menu “remote siren”

Fig4: choose enable/disable

25. SMS Replay for Arm/Disarm


When the user arm or disarm the system, other users may not know it. Enable
this function, the panel will send SMS notification to all SMS numbers, so
that users could know the status or the system in time SMS content.
Method: enter “settings” menu, and then you’ll see “operate password”. Press
“6” to choose “arm disarm SMS” and choose “enable or “disable”.
Operation figures:
Fig1: enter setting menu Fig2: you’ll see “operate Fig3: press“6”to choose
password” menu “arm disarm SMS”

Fig4: choose enable/disable

26. Language Setting

19
This alarm system supports English and Chinese versions. Please enter
“settings” menu, and then you’ll see “operate password. Press “6” to choose
“language”. Then press “ok” will shift between Chinese and English.
Operation figures:
Fig1: enter setting menu Fig2: you’ll see “operate Fig3: press “6” to choose
password” menu “language”

Fig4: choose the version you need

27. Factory Reset


When the system is unstable, it is recommended to reset it. Enter “settings”
menu, and then you’ll see “operate password”. Press “6” to choose “factory
setting”. After this operation, all the settings return to factory default
Operation figures:
Fig1: enter setting menu Fig2: you’ll see “operate Fig3: press “6” to choose
password” menu “factory setting”

Fig4: Press “ok” to confirm

20
Chapter 5.Operation Instruction
1. Out Arm
Out arm means all the defense zones are in arm status. When there’s
nobody at home, it is required to set all the detectors working. Any
detection source (such as thief, fire, or gas leakage) trigger the detector, the
alarm system will make alarm.
Remote controller operation: press arm button [ ] on the remote
controller.
Main panel operation: press [ ]. The system will enter arm status after the
delay time (default; 60 seconds)

2. Home Arm
Home arm means part of the defense zones are in arm status. When there’s
someone at home, it is recommended, for safety purpose, to enable some of
the detectors (such as sensors for door, window, balcony, etc, and disable the
others (such as sensors for the hall or some places easy to be triggered by
person at home)
Remote controller operation: press home arm button [ ] on the remote

21
controller.
Main panel operation: press [0+ ].
3. Disarm
The purpose of disarming the system is to let it not in alert status. One way is
normal disarming after operation of arming, and the other is to stop the main
unit alarming. After the operation of disarm, all the defense zones except 24-
hour zone shall not work.
Remote controller operation: press disarm button [ ] on the remote
controller.
Main panel operation: password (default: 1234) + “ok”.

4. Answer Alarm Call


When the main unit sounds alarm, it will dial the preset numbers. If no one
answers the call, the system will call the next number automatically. It will
call all the preset numbers in order for 3 times. If you answer the call, you can
set system via your telephone or mobile phone keypad. If you hang up directly
without answering the call, the system will call all the numbers circularly for 3
times.
Press[*]:read the alarm information.
Press[1]:Main unit stops alarming and Arm; it stops calling users.
Press[2]:Main unit stops alarming and Disarm; it stops calling users.
Press[3]:Siren off and monitors the scene for 30 seconds; for continued
monitoring, press [3] again to monitor for another 30 seconds
Press[4]:Main unit starts a 30-second two-way intercom It cannot be

22
controlled the mobile during the time of intercom
5. Remote Control
Dial the number associated to the alarm main unit by phone (mobile phone),
and after the ringing cycle, you can hear a voice prompt “Please inter
password (default: 1234)”.If the password is right, you will here “Press Enter
induction”. Press 1 to arm, Press 2 to disarm, Press 3 to monitor, Press 4 to
intercom. If the password is wrong, you will hear a prompt voice “wrong
password, please re-enter”,
Press[1]: arm, if finished successfully, you will hear a voice prompt “System
armed”.
Press[2]: disarm, if finished successfully, you will hear a voice prompt
“System disarmed”.
Press[3]:monitoring for 30 seconds, to continue monitoring. Press [3] again to
monitor for another 30 seconds
Press[4]:two-way intercom for 30 seconds. You can’t operate the main unit
during this time.

6. Emergency help
Sometimes, there may be some accidents happening (such as sudden illness of
old people or children, fire accident, burglar intrusion).Press [SOS] button on
keypad, or [ ] button on the remote controller or wireless panic button, the
main unit will alarm and make call to the preset user numbers.
Remote controller operation: press [ ] button on the remote controller.
Main panel operation: press [SOS].
The SMS content for emergency help is: 00 zone SOS alarm.
7. System Dialing Function
In disarm status, you can use the main unit to make any call just like a land-
line telephone. Dial telephone number on keypad, press [ ] button, the main
unit will make a beep and the LCD screen will display the number you are
calling. After the call, press [ ] button again, the call will be hanged up

23
and main unit will be in disarm status.
8. Alarming Record Checking
This alarm system can store 200 alarm records. The last alarm is ranked as the
first record. And when the record number exceeds 200, the most previous
record will be deleted automatically.
Checking method: In disarm state, input [00] + status “ok”, the main unit
enters the state of alarm record checking. Press “4” or “6” to upturn or
downturn, and press “ESC” to exit checking.

Fig1:press 00 in disarm status Fig2; press 4 or 6 to check Fig3:press 4 or 6 to check

Chapter6. Technical Parameters


Input Voltage: DC12V/1A
Standby Current: <40mA
Alarming Current: <450Ma
Wireless Frequency: 433/315MHZ EV1527
GSM Frequency: 850/900/1800/1900MHZ
Back-up Battery: Lithium ion rechargeable battery
Siren Volume: 100-110Db