Thank you for purchasing this C&K alarm system. Your system is one of the most powerful and advanced alarm systems on the market today designed to provide you with years of reliable operation. This manual explains how to operate your alarm system. Basic operating instructions are also printed on the small label attached to the inside of your keypad(s) door. If you have questions or need help with your alarm system, call:
(Alarm Company Name)
______________________________________ ______________________________________
______________________________________ ______________________________________
When calling the monitoring company, know the following: My Account Number is: _______________________ My Password is:_____________________
Table of contents
Getting acquainted .............................................. 4-5 What the lights mean ........................................... 6 What the sounds mean ....................................... 7 Arming the system ............................................... 8-17 Arming options .................................................... 18-19 Disarming the system .......................................... 20 After an alarm ...................................................... 21 Options ................................................................ 22-34 Duress (Systems 238, 238i, 2316, 2316i ,236i only) ...... 23-24 Guest combination (Systems 238, 2316 only) .......... 25 Changing a User PIN - System 238 ......................... 26-27 Deleting a User PIN - System 238 ............................ 28 Changing a User PIN - System 236, 2316 ............... 29-30 Deleting a User PIN - System 236, 2316 .................. 31-32 Resetting smoke detectors ............................. 33 Testing your system ............................................ 35-37 Local System Test .......................................... 35 Standby Battery Test ...................................... 36 Bell/Siren Test ................................................. 36 Central Station Test ........................................ 37 Telephone trouble ............................................... 38 Customizing your keypads .................................. 39 Language versions .............................................. 40 Smoke detector placement ................................. 41 Emergency evacuation ........................................ 42 Definitions ............................................................ 43 Limitations of your alarm system ......................... 44 Test procedures index ......................................... 45 Zone description list ............................................ 46-48 .CC Notice / Industry Canada ............................ 50-51
What your alarm system is... Your alarm system is made up of a control panel and several detection devices like motion sensors, magnetic contacts, and so on. Specific areas of detection are called zones. Zones can be programmed to have different characteristics. Some zones may be 24-hour zones, that is, they remain armed even when the alarm system is off. Zones used for fire detection, for example, are always 24-hour zones. In addition, some zones can be programmed to allow bypassing. When you bypass a zone, you temporarily remove it from the alarm system. Always remember, however, that bypassed zones are not protected. How your alarm system works... When a detection device is triggered, the status of its zone goes from normal to .AULTED. If armed, the control panel responds by reporting an alarm condition on site sounding bells, message on keypad display and if programmed, by transmitting an alarm signal over the telephone wires to a central monitoring station. The monitoring station then dispatches the appropriate authorities. Some of your system's operations require you to enter your personal identification number (PIN) on the keypad. These include ARMING and DISARMING. Along with its many other features, your system can be programmed to ARM INSTANTLY or to ARM WITH TIME DELAY (i.e., after giving you time to leave the premises).
Each alarm system in the 2300 family is designed to meet the specific needs of a variety of applications. System 236 is specifically designed for smaller, six zone applications. Systems 238 and 2316 are designed for applications requiring protection of eight and sixteen zones, respectively. Although these systems do not offer all the same options, your alarm professional has installed the system best suited for your application. Refer to the headings at the top of each page to determine if an option is available on your system. (If no systems are listed in the page heading, the option is available on all systems.) Some of the available features of your alarm system are also optional, and will only be installed if appropriate for your installation. In addition, some system features will require you to enter your personal identification number (PIN). As you read through this manual, watch for boxes like these: OPTION INSTALLED box will be checked.
OPTION INSTALLED PIN REQUIRED
. If an optional feature has been installed in your system, its . If a feature of your system requires you to enter your personal
identification number, its PIN REQUIRED box will be checked.
POWER LIGHT
AC POWER .AILURE LOW BATTERY Off Slow .lash
ARMED LIGHT
REMARKS
Power .ailure. System is operating on battery. Battery is low; Call your service department. LCD display will show system trouble.
SYSTEM ARMED SYSTEM DISARMED SYSTEM IS ARMED WITH DELAY ZONES CONVERTED TO INSTANT LCD DISPLAY Invalid PIN Trouble Zone
On
Protection is on.
Off
Protection is off.
Slow .lash NORMAL MESSAGES Ready to ARM .aulted Zone Entry-Disarm Now
SYSTEM TROUBLE MESSAGES AC .ail Connection .ail Low Battery Bell .use .ail
SOUND
2 beeps 5 beeps
continuous tone, beeping fast for last ten seconds continuous beeping, speeding up for last ten seconds 2 second beep
MEANING . system armed or disarmed . successful central station test or battery test . wrong PIN number entered . invalid function . unauthorized command attempted . error changing PIN number . entry delay time . exit delay time . door chime . ring back after closing report* . zone faulted during walk-test . chirp alert warning: system is armed, but a delay zone is faulted; you must disarm the system before entry delay expires or alarm will occur* . alarm signal for zone programmed for chirping bell or siren . alarm signal for zone programmed for steady bell or siren . circuit malfunction (trouble on supervised loops only) . alarm signal for zone programmed for pulsed bell or siren
*Not available on System 236/236i
TO ARM THE SYSTEM: . .aulted zones must be cleared or bypassed before the system can be armed.
Make sure the display reads READY TO ARM.
If the display reads NOT READY TO ARM, followed by .AULTED ZONE, push the # key. The display will then indicate which zone(s) are faulted. .or more information, refer to the sections Bypassing Zones and After An Alarm Occurs.
PIN REQUIRED
. Don't pause for more than 5 seconds while entering the digits or the control panel will . If you make a mistake while entering your PIN number, the keypad will beep five times.
After the fifth beep, enter your PIN number again. 236/236i PIN = 4 digits long 238/238i PIN = 2 - 5 digits long 2316/2316i PIN = 2 - 5 digits long reject your PIN number.
. The keypad will beep twice to confirm that the system is armed. . The display will read EXIT NOW. . The exit delay time can be programmed from 10 seconds to 150 seconds. . If the EXIT PRE-ALARM option is installed, the keypad will beep slowly until 10 seconds . A bar graph will appear on the display, showing how much exit time remains. . Once the exit time has expired, the keypad will beep twice to confirm that the system is
armed, and the display will read ARMED. before the delay time expires, then rapidly for the last 10 seconds.
seconds.
OPTION INSTALLED
The rest of the Arming The System section describes other arming options, and explains how to bypass zones before arming the system. No matter how your system is programmed, you will always disarm it in the same way: enter your PIN, then push the # key.
PIN REQUIRED
. If you do not exit before the exit delay time expires, the system will automatically arm . If you exit through an exit delay door during the Exit Delay Time, the system will automatically arm interior and perimeter zones. perimeter zones and bypass interior zones.
10
INSTANT ARMING
Instant Arming converts all time delayed zones to INSTANT zones. Make sure that the display reads READY TO ARM.
PIN REQUIRED
. The keypad will beep twice to confirm that the system is armed, . The red ARM light will flash while the system is Instant Armed.
and the display will read ARMED - INSTANT.
Enter your PIN (if required), push the key, enter the digit "7", then push the # key.
OPTION INSTALLED
. Bypassing interior zones will allow you to move about freely inside the premises while . Exit Delay Disable (see page 19).
the system is armed. Refer to BYPASSING ZONES (pages 14 - 17).
CAUTION: When the system is Instant Armed, you will not be able to enter through any perimeter door or walk through any protected area without setting off an alarm.
11
HOME ARMING
Home Arming arms perimeter zones, while bypassing interior zones. Make sure that the display reads READY TO ARM.
PIN REQUIRED
. The keypad will beep twice to confirm that the system is armed,
and the display will read ARMED.
Enter your PIN (if required), push the key, enter the digit "4", then push the # key.
. The red ARM light will flash while the system is armed. . Home Arming allows you to move about freely inside the premises while the system is . When the system is Home Armed, you can enter the premises without setting off an
OPTION INSTALLED
armed.
alarm through a delayed entry zone. (Don't forget to disarm the system after entry!)
12
. The keypad will beep twice to confirm that the system . The red ARM light will flash while the perimeter zones
are instant armed.
OPTION INSTALLED
Enter your PIN (if required), push the key, enter the digit "7", the digit "4", then push the # key.
* *
7
OR
4 7
# #
CAUTION: When the system is Instant Home Armed, you will not be able to enter through any perimeter door without setting off an alarm.
13
BYPASSING ZONES
This procedure allows you to bypass one or more zones while your system is DISARMED.
NOTE: System programming determines which PINs can bypass zones, also which zones can be bypassed. To learn if a zone can be bypassed, see the Zone description list on pages 46-48.
PIN REQUIRED
If required, enter your PIN. Push the key, enter the zone to be bypassed, then push the # key.
ZONE #
NOTE: Zones can also be bypassed by remote programming. The system can either be armed or disarmed for remote programming.
14
. To indicate that zones are bypassed, the display will read BYPASSED ZONE. . The procedures for adding a bypass and removing a bypass are identical.
which zones are bypassed, push the # key (once for each bypassed zone).
PIN (if required), push the key, enter the first zone to be bypassed, push the key again, enter the next zone to be bypassed, and so on. When the last zone to be bypassed has been entered, push the # key.
ZONE #
ZONE #
To see
. When you have finished bypassing zones, arm the system by entering your PIN and
pushing the # key. NOTE: Disarming your alarm system REMOVES all bypasses.
To remove a bypass: enter your PIN, push the key, enter the zone from which the bypass is to be removed, then push the # key.
15
BYPASSING ZONES
This procedure allows you to bypass one or more zones while your system is DISARMED1 (See NOTE page 17 ).
NOTE: System programming determines which PINs can bypass zones, also which zones can be bypassed. To learn if a zone can be bypassed, see the Zone description list on page 46.
PIN REQUIRED
Enter your PIN (EBHAGKEHA@). Push the key, enter the digit "2", enter the zone to be bypassed, then push the # key.
OR
OPTION INSTALLED
2
ZONE #
OPTION INSTALLED
Push the key, enter the zone to be bypassed, then push the # key.
#
ZONE #
16
.
1
To indicate that zones are bypassed, the display will read BYPASSED ZONE. To see which zones are bypassed, push the # key.
NOTE: Zones can also be bypassed by remote programming. The system can either be armed or disarmed for remote programming.
. .
The procedures for adding a bypass and removing a bypass are identical. To remove a bypass:
Enter your PIN, push the key, enter the digit "2", enter the zone from which the bypass is to be removed, then push the # key.
OR
Enter your PIN, push the key, enter the zone from which the bypass is to be removed then press the # key.
NOTE: Disarming your alarm system REMOVES all bypasses.
17
Your alarm system has been programmed for one of the following arming types:
OPTION INSTALLED
GOO.-PROO. ARMING
If any zone other than a 24-hour zone is faulted (open window, malfunctioning sensor, etc.), your system will not arm. You will not be able to arm the system until the faulted zone is cleared or manually bypassed.
OPTION INSTALLED
.ORCE ARMING
Any zone (except for 24-hour zones) that is violated during the EXIT DELAY time has expired will be automatically bypassed until the system is disarmed. Warning: bypassed zones are not protected.
18
OPTION INSTALLED
CHIRP ALERT (Available on Systems 238, 238i, 2316 and 2316i ONLY)
The system will arm even if delayed or interior zones are faulted at the time of arming. If an EXIT DELAY zone is still faulted when the EXIT DELAY time expires, the bell/siren will begin to chirp. The chirping will continue for the duration of the ENTRY DELAY time. You must re-enter the premises and disarm the system before the ENTRY DELAY time expires or an alarm will occur.
OPTION INSTALLED
If this option is installed, the exit delay will be eliminated when arming your system using Instant Arming (page 11), Home Arming (page 12), or Instant Home Arming (page 13).
19
. If the ENTRY PRE-ALARM option is installed, the keypad will sound constantly until 10 . The display will read ENTRY - DISARM NOW.
showing how much entry time remains. A bar graph will appear on the display,
seconds before the delay time expires (or the panel is disarmed), then beep rapidly for the last 10 seconds.
PIN REQUIRED
Enter your PIN within seconds and push the # key. Make sure the red ARM light on the keypad goes off.
PIN again.
. If the ARM light does not go off, wait for the keypad to beep five times, then enter your . The display will read READY TO ARM or NOT READY TO ARM (if a zone is faulted).
20
. This will silence the bell/siren and disarm the system. . The display will read ALARM ZONE. To see which zones are in alarm, push the # key.
If this is a false alarm and no emergency response is needed, call our central station IMMEDIATELY at to cancel the alarm. Clear the alarm memory and the display by pushing the key, entering the digit "1", then pushing the # key.
. Write down the number of the triggered zones to help us service you.
21
(Note: The following Options are available on all Systems, UNLESS OTHERWISE NOTED.)
OPTION INSTALLED
24-HOUR MONITORING
With this option installed, your alarm system will transmit alarm signals to our central station. When this option is installed, holding the EMERGENCY key down for three seconds will trigger an alarm. The keypad will beep twice to confirm the alarm condition.
OPTION INSTALLED
EMERGENCY KEY (Available on Systems 238, 238i, 2316 and 2316i ONLY)
.
OPTION INSTALLED
Systems 238, and 2316 have not been investigated by Underwriters Laboratories for compliance with UL 1637, Home Health Care Signalling Equipment. NOTE: When used with System 236 or 236i, this key functions as POLICE/PANIC.
.IRE KEY
When this option is installed, holding down the .IRE key for three seconds will trigger an alarm. The keypad will beep twice to confirm the alarm condition.
NOTE: When used with System 236 or 236i, this key functions as POLICE/PANIC.
22
OPTION INSTALLED
POLICE/PANIC KEY
When this option is installed, holding down the POLICE key for three seconds will trigger an alarm. The keypad will beep twice to confirm the alarm condition.
OPTION INSTALLED
Should an intruder force you to turn your security system off or on, you can send a silent DURESS signal to our central station by adding or subtracting "1" from the last digit of your PIN. .or example, if your PIN is 1-2-3-4, entering 1-2-3-3 OR 1-2-3-5 will trigger a silent alarm. Your system will appear to be operating normally. There will be no indication of an alarm condition.
"9" or "1" instead of the "0" will trigger a DURESS signal. If your PIN ends with a "9", entering "8" or "0" instead of the "9" will trigger a DURESS signal.
23
OPTION INSTALLED
Should an intruder force you to turn your security system off or on, you can send a silent DURESS signal to our central station by entering User Code 6 a code designated exclusively for a DURESS signal. Your system will appear to be operating normally. There is no indication of an alarm condition.
OPTION INSTALLED
DURESS ALARM (Available on Systems 238i and 2316i ONLY) Should an intruder force you to turn your security system off or on, you can send a silent DURESS signal to our central station by entering User Code 7 a code designed exclusively for a DURESS signal. Your system will appear to be operating normally. There is no indication of an alarm condition.
24
OPTION INSTALLED
. Once the time expires, the GUEST COMBINATION will have to be reprogrammed before
it can be used again.
OPTION INSTALLED
If your system is programmed to send closing reports to a monitoring station, ring back will occur after the signal has been sent and acknowledged; otherwise, ring back occurs when the exit delay has expired.
25
User 1 can use his Master PIN to change the PINs of Users 1 - 8. Enter your Master PIN, push the key, enter the digit "0", then push the # key.
# #
. The new PIN can be from two to five digits long, but must start with
the same first digit as the old PIN.
If the new PIN is accepted, the keypad will beep twice, and the display will read PIN ACCEPTED. If you make a mistake while programming, or if the system rejects the new PIN, the keypad will beep five times, and the display will read INVALID PIN.
26
System: 238 and 238i ONLY Exit the programming mode by pushing the key, then the # key. Make sure the new PIN works.
After leaving the programming mode, Arm and Disarm your system to ensure that the new PIN functions properly.
27
User 1 can use his Master PIN to delete the PINs of Users 2 - 8. Enter your Master PIN, push the key, enter the digit "0", then push the # key.
# # #
Enter the User number (2 - 8) you wish to delete, and push the # key. Enter the User number you wish to delete (again), and push the # key.
User 1 can use his Master PIN to change the PINs of Users 1 - 6 (on System 236 and 236i) or Users 1 - 32 (on System 2316 and 2316i).
MASTER PIN REQUIRED
# #
. Enter User number 1 - 6 for System 236/236i. . Enter User number 1 - 32 for System 2316/2316i. (See Note below.)
Enter the new PIN and push the # key.
USER NUMBER
. The new PIN must be four digits long for System 236/236i. . The new PIN can be from two to five digits long for System 2316/2316i.
NOTE: On System 2316i, User Code #32 is reserved for special functions using the Optional Relay Output Module.
29
System: 236, 236i, 2316,and 2316i ONLY Enter the new PIN and push the # key. #
. The new PIN must be four digits long for System 236/236i. . The new PIN can be from two to five digits long for System 2316/2316i.
NOTE: On System 2316i, User Code #32 is reserved for special functions using the Optional Relay Output Module.
If the new PIN is accepted, the keypad will beep twice, and the display will read PIN ACCEPTED. If you make a mistake while programming, or if the system rejects the new PIN, the keypad will beep five times, and the display will read INVALID PIN.
Exit the programming mode by pushing the key, then the # key.
*
30
User 1 can use his Master PIN to delete the PINs of Users 2 - 6 (on System 236 and 236i) or Users 2 - 32 (on System 2316 and 2316i) (See note pg. 29).
MASTER PIN REQUIRED
# #
USER NUMBER . Enter User number 2 - 6 for System 236 and 236i. . Enter User number 2 - 32 for System 2316 and 2316i (See note pg. 29).
System: 236/236i
Enter four zeros and push the # key. Enter four zeros (again) and push the # key.
0 0
0 0
0 0
0 0
# #
31
System: 236, 236i, 2316 and 2316i ONLY Enter zero and push the # key.
System: 2316/2316i 0 0
# # #
Enter zero (again) and push the # key. Exit the programming mode by pushing the key, then the # key.
32
OPTION INSTALLED
When a smoke detector is triggered, the keypad display will read ALARM ZONE, and the bell/siren will sound. Before you do anything else, evacuate the building. Don't go back inside until you're sure it's safe. When it's safe to do so, you can reset the smoke detectors by doing the following: Push the key, enter the digit "6", the digit "2", and push the # key.
33
OPTION INSTALLED
When this option is installed, all keypads on the premises will beep for two seconds each time a designated zone is faulted. To turn the door chime (on all keypads) on and off:
DOOR CHIME
Push the key, enter the digit "5", then push the # key.
STANDBY BATTERY
Should there be a loss of AC power, the green POWER light on the keypad will go out, and your alarm system will switch to its standby battery. If an AC power failure lasts for more than 15 minutes, the display will read SYSTEM TROUBLE.
. If you push the # key, the display will read AC POWER .AIL. . The standby battery should be replaced every four to six years with a rechargeable
12 volt, 6.5 Ah, sealed lead-acid battery (such as C&K Model 1265).
34
This option allows on-site testing of each zone in your system. Enter your PIN (if required), push the key, enter the digit "6", the digit "0", then push the # key.
. To exit the system test, push any key. The display will momentarily read
SYSTEM RESET.
6 Walk through the areas protected by motion sensors; open and close protected doors and windows. Each time a zone is faulted, the display will show the faulted zone's identification, and the keypad will chime.
WARNING: Your alarm system will not report alarms during the LOCAL SYSTEM TEST.
35
OPTION INSTALLED
Your alarm system can be programmed to automatically test its standby battery every 24 hours. During the test, AC power is turned off in order to monitor the battery under load.
. The standby battery test takes 2 minutes. During the test, the green AC light will be off. . If the battery is okay, the keypad will beep twice, and the display will read
OPTION INSTALLED
key, enter the digit "6", the digit "4", then push the # key. The display will read BATTERY TEST.
TEST - PASSED. If the battery is low or dead, the green AC power light will flash, the keypad will beep five times, and the display will read TEST - .AILED.
BELL/SIREN TEST
PIN REQUIRED
To test the bells/sirens in your security system: Enter your PIN (if required), push the * key, enter the digit "6", the digit "3", then push the # key.
36
OPTION INSTALLED
This option tests the reporting capability of your system by sending a test message to the central station. Weekends are the best time for the CENTRAL STATION TEST. To schedule one, call our central station at: CENTRAL STATION To initiate the CENTRAL STATION TEST: Enter your PIN (if required), push the key, enter the digit "6", the digit "1", then push the # key.
PIN REQUIRED
. The display will read TEST REPORTING. . If the test message was successfully transmitted to
. If the test message was not successfully transmitted to the central station, the
the central station, the keypad will beep twice, and the display will read TEST - PASSED. keypad will beep five times, and the display will read TEST - .AILED. Call our Service Department for assistance.
37
.irst, unplug the control panel from its telephone jack to determine if the alarm system is causing the trouble. The phone jack is located .
If the trouble goes away when you unplug the control, call us for service. If you still have telephone trouble after unplugging the alarm system, plug the system back in, then call your telephone company.
NOTE: If your telephone system is serviced, make sure to test your alarm system to insure that it has not been disconnected from the telephone network.
38
You can customize the characteristics of ALPHA Plus keypads by using the combinations shown below. .or example, if you have two keypads on site, you can turn the backlight of one keypad off, while leaving the backlight of the other on.
* * * *
5 5 5
8 1 2 3
# # # #
. To turn the entry and exit delay warning tones on or off, push the * key, enter the digits "5" and "2", then push the # key. . To turn the door chime tones on or off (at each keypad), push the * key, enter the digits "5" and "3", then push the # key.
39
The ALPHA Plus keypad is programmed to display messages in several different languages. Use the combination shown in the left column to access your language. The column checked indicates the languages available on your system.
Key Combinations
Alpha Plus I ENGLISH SPANISH .RENCH CANADIAN - .RENCH ITALIAN GERMAN DUTCH PORTUGUESE
Alpha Plus II ENGLISH HUNGARIAN CZECH POLISH NORWEGIAN .RENCH ITALIAN SWEDISH
* * * * * * * *
40
3 3 3 3 3 3 3 3
1 2 3 4 5 6 7 8
# # # # # # # #
We subscribe to the recommendations for the number and placement of smoke and/or heat detectors found in the National .ire Protection Association's Standard #72, Chapter 2 (N...P.A. Batterymarch Park, Quincy, MA 02269). .or the best early warning, fire detection devices should be installed in all rooms and areas of the premises. A smoke detector should be installed in each separate sleeping area, in the vicinity of bedrooms. (In new construction, a smoke detector shall be installed in each sleeping room.) Heat or smoke detectors should be installed in living rooms, closets, utility and storage rooms, basements, and attached garages.
Place detector near all sleeping areas
DINING ROOM KITCHEN BEDROOM
Best residential detector placement between bedrooms and the rest of the house
BEDROOM
BEDROOM
KITCHEN
DINING ROOM
BEDROOM BEDROOM
= SMOKE DETECTOR
BEDROOM LIVING ROOM
C S K
BEDROOM BASEMENT
BEDROOM
41
Every household should establish and regularly practice an escape plan in the event of a fire. The following steps, recommended by the National .ire Protection Association, can be used as a guide in developing your own emergency plan.
. Plan on your detector or alarm system sounders waking all occupants. . Determine two means of escape from each room, especially
. Sketch a floor plan, showing doors, windows, stairs, and rooftops . Keep all bedroom doors shut while the occupants are asleep.
KITCHEN DINING SAMPLE
the bedrooms, since most fires occur at night when everyone is asleep. One escape path should lead to a door that permits normal exit from the house. The other may be an easily opened window (used if the primary escape path is blocked).
. Escape quickly. But don't panic. . Before you open a door, check to see if it's hot. If it is hot, don't
everyone can gather and account for those missing. Choose someone to notify the authorities. Choose someone to ensure that nobody returns to the house. Many die going back inside.
that can be used for escape. Indicate escape routes for each room (see examples below). Post copies of the sketch in each room. Remember to keep all escape routes free from obstruction. This will prevent deadly smoke from entering the rooms while you escape.
open it. Use an alternate escape route. Even if the door is cool, use your shoulder to open it cautiously. Be ready to slam it closed if heat or smoke rushes in.
.IRST .LOOR
LAUNDRY BATH LIVING ROOM
SECOND .LOOR
BEDROOM BATH BEDROOM
SAMPLE
42
ALARM A condition that occurs when the detection devices in a zone are triggered after the system is armed. ALARM MEMORY Alarm conditions are stored in memory until cleared. BYPASS To take a zone out of the circuit. Bypassing malfunctioning zones allows the rest of the system to be armed. Bypassing interior zones allows freedom of movement inside the premises, while leaving outer zones armed. Bypassed zones are not protected. CENTRAL STATION The office that the alarm system calls when there is an alarm. Signals sent to the central station contain information about the nature of the alarm condition, allowing the dispatcher on duty to appropriately respond. ENTRY DELAY The time you have to enter the premises through a designated DELAY DOOR and disarm the panel (before an alarm occurs). The delay time is programmable from 10 seconds to 150 seconds. [NOTE: if this option is programmed for Long Delay, the delay will be doubled (from 20 to 300 seconds).]
EXIT DELAY Once the system is armed, the time you have to exit the premises through a DELAY DOOR (before an alarm occurs). The delay time is programmable from 10 seconds to 150 seconds. .AULT A trouble condition that occurs when the detection devices in a zone are violated or malfunctioning while the system is disarmed. GRADE "A" System that provides supervision of the transmitter or initiating devices (i.e., detection devices and wiring). PERSONAL IDENTI.ICATION NUMBER (PIN) The combination used to arm and disarm the control panel, and to access any of the special functions that require a combination. (With System 236/236i, the PIN number must be four digits long.) ZONE One of the protected areas in your premises. 24-HOUR ZONE A zone that is always active, whether the system itself is armed or disarmed. .IRE, POLICE, and EMERGENCY zones are usually 24-hour zones. Alarm conditions on these zones are cleared by entering a valid PIN number.
43
. . . . .
. .
44
As required by UL Standard 1023, your alarm system is a Grade "A" system (see definition on page 43). Alarm system malfunctions and failures are caused most often by INADEQUATE MAINTENANCE. Your alarm system should be tested weekly to make sure that all detection devices are working properly. In addition, if your system is being monitored, you should periodically test its ability to transmit signals to our central station. These tests should be performed weekly:
. LOCAL SYSTEM TEST: Enter PIN (if required), then . CENTRAL STATION TEST: Enter PIN (if required), then . BELL/SIREN TEST: . STANDBY
Enter PIN (if required), then
BATTERY TEST
* * * *
6 6 6 6
0 1 3 4
# # # #
45
ZONE LOCATION 1 2 3 4 5 6
BYPASS
YES NO
46
ZONE LOCATION 1 2 3 4 5 6 7 8
BYPASS
YES NO
47
ZONE LOCATION 9 10 11 12 13 14 15 16 48
BYPASS
YES NO
Notes
49
.CC NOTICE
WARNING: This device is intended to be installed by a professional alarm installer. The user shall be cautioned that changes or modifications not expressly approved by C&K SYSTEMS could void the users authority to operate the equipment. .CC Rules PART 15 This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the .CC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient the radio/television antenna. Connect the AC transformer to a different outlet so that the control panel and radio/television are on different branch circuits. Relocate the control panel with respect to the radio/television. Consult the dealer or an experienced radio/television technician for help. .CC Rules PART 68 This equipment has been tested and found to comply with Part 68 of the .CC Rules. On the left outside panel of the can is a label that contains the .CC registration number and the Ringer Equivalence Number (REN) for this equipment. This information must be provided to your telephone company, if requested. The REN may be used to determine the maximum number of devices which may be connected to your telephone line and still have all devices ring properly when your number is called. The maximum sum of all devices should not exceed 5. This number may be different in your area. Contact your local telephone company to determine the maximum REN for your calling area. Should you experience trouble with the telephone lines, disconnect the panel from the line to determine the source of the trouble. If it is determined that the control panel is malfunctioning, discontinue its use until the malfunction has been corrected. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telephone company cause to request the user to disconnect the equipment. Repairs to this equipment should be made by an authorized agent of C&K SYSTEMS, Inc. Contact your local alarm installation company for service. Should this equipment cause harm to the telephone system, the telephone company may temporarily discontinue your service. If possible, they will provide you with advance notice. Otherwise they will notify you as soon as possible. The telephone company will also advise you of changes in its facilities, equipment, operations or procedures which could affect the operation of your equipment, allowing you the opportunity to maintain uninterrupted service. You will also be advised of your right to file a complaint with the .CC. This device must not be used on party lines or coin operated phone lines.
50
Industry Canada
NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. Industry Canada does not guarantee the equipment will operate to the users satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the companys inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Should you experience trouble with the telephone lines, disconnect the panel from the line to determine the source of the trouble. If it is determined that the control panel is malfunctioning, discontinue its use until the malfunction has been corrected. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telephone company cause to request the user to disconnect the equipment. Repairs to this equipment should be made by an authorized agent of C&K SYSTEMS, Inc. Contact your local alarm installation company for service. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all devices does not exceed 100. This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Industry Canada. Le prsent appariel numrique nmet pas de bruits radiolectriques dpassant les limites applicables aux appareils numriques de la Class B prescrites dans le Rglement sur le brouillage radiolectriques dict par Industrie Canada.