NOTE: Use this procedure together with the Master Minimum Equipment List (MMEL).
If the fault indication is because of a defect in the indication system it is permitted to disp
atch the aircraft. It is also permitted to dispatch the aircraft if the defect is in the RAT gro
und test system (if the system is known to be in the "flight" condition).
It is not permitted to dispatch the aircraft if the fault indication is because of a defect whi
ch could prevent operation of the RAT.
NOTE: If any part of the system is deactivated, after each flight, the deactivated component mu
st be reactivated and this procedure done again. This is to find any faults which were not
shown because of the deactivation.
A. Referenced Information
REFERENCE DESIGNATION
Ref. 24-41-00-861-002-A Energize the Aircraft Electrical Circuits from the External Po
wer
Ref. 24-41-00-861-002-A01 Energize the Aircraft Electrical Circuits from the APU
Ref. 24-41-00-861-002-A02 Energize the Aircraft Electrical Circuits from Engine 1(2)
Ref. 24-41-00-862-002-A De-energize the Aircraft Electrical Circuits Supplied from the
External Power
Ref. 24-41-00-862-002-A01 De-energize the Aircraft Electrical Circuits Supplied from the
APU
Ref. 24-41-00-862-002-A02 De-energize the Aircraft Electrical Circuits Supplied from the
Engine 1(2)
Ref. 29-10-00-863-003-A Pressurize the Blue Hydraulic System with a Hydraulic Groun
d Power-Cart
Ref. 29-10-00-863-003-A01 Pressurize the Blue Hydraulic System with the Blue Electric
Pump
Ref. 29-10-00-864-003-A Depressurize the Blue Hydraulic System
Ref. 29-22-00-869-005-A Extension of the Ram Air Turbine (RAT) on the Ground
Ref. 29-22-00-869-006-A Retraction of the Ram Air Turbine (RAT) on the Ground
Ref. 31-60-00-860-001-A EIS Start Procedure
Ref. 31-60-00-860-002-A EIS Stop Procedure
Ref. TSM 29-22-00-810-801 Fault of the Ram Air Turbine
Ref. Fig. Location of RAT - Components
3. Job Set-up
SUBTASK 29-30-00-860-050-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-861-002.
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
Ref. AMM TASK 31-60-00-860-001.
(3) On the ECAM control panel on the center pedestal, press the HYD pushbutton switch
(P/BSW). Make sure that the ECAM lower Display Unit (DU) shows the HYD page.
(4) Make sure that the ECAM upper DU shows the RAT FAULT indication.
SUBTASK 29-30-00-010-056-A
B. Get Access
(1) Open the access panels 195BB and 197EB.
4. Procedure
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
about:blank 2/4
6/19/24, 11:59 PM ABY - A318 / A319 / A320 / A321 - AMM - FSN: 317 - 01-May-2024 - 29-30-00-040-001-A - Integrity Check of the RAT after RAT F…
(a) Pressurize the Blue hydraulic system Ref. AMM TASK 29-10-00-863-003.
(b) Extend the RAT Ref. AMM TASK 29-22-00-869-005. If the RAT STOWED indicat
or light comes on, ignore it.
(c) Make sure that the RAT stays in the deployed position.
(d) Retract the RAT Ref. AMM TASK 29-22-00-869-006. If the RAT STOWED indicat
or light goes off, ignore it.
(e) Make sure that the RAT stays in the stowed position. If the RAT FAULT indicator
light comes on, ignore it. This RAT FAULT warning is false.
(f) Depressurize the Blue hydraulic system Ref. AMM TASK 29-10-00-864-003.
5. Close-up
SUBTASK 29-30-00-410-054-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access panels 195BB and 197EB.
SUBTASK 29-30-00-860-051-A
B. Put the aircraft back to the serviceable condition.
(1) Do the EIS stop procedure
Ref. AMM TASK 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-862-002.
A B
195BB
197EB
1GE -E
C C
E J E CT I O N J A CK
B
I N D I C AT I O N L I G H T S
RAM
AIR
TURBINE
RESET
O
RAT CONTROL N
STOW LAMP
TEST
PANEL 3GE
O
F
28V DC F
J 2