Brocade VA40FC HardwareManual
Brocade VA40FC HardwareManual
Brocade VA40FC HardwareManual
31 May 2012
Brocade VA-40FC
Hardware Reference Manual
2012 Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, MLX, SAN Health, VCS, and VDX are registered trademarks, and
AnyIO, Brocade One, CloudPlex, Effortless Networking, ICX, NET Health, OpenScript, and The Effortless Network are trademarks of
Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names
mentioned may be trademarks of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning
any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to
this document at any time, without notice, and assumes no responsibility for its use. This informational document describes
features that may not be currently available. Contact a Brocade sales office for information on feature and product availability.
Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with
respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that
accompany it.
The product described by this document may contain open source software covered by the GNU General Public License or other
open source license agreements. To find out which open source software is included in Brocade products, view the licensing
terms applicable to the open source software, and obtain a copy of the programming source code, please visit
http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Document History
Corporate and Latin American Headquarters
Brocade Communications Systems, Inc.
130 Holger Way
San Jose, CA 95134
Tel: 1-408-333-8000
Fax: 1-408-333-8101
E-mail: [email protected]
Asia-Pacific Headquarters
Brocade Communications Systems China HK, Ltd.
No. 1 Guanghua Road
Chao Yang District
Units 2718 and 2818
Beijing 100020, China
Tel: +8610 6588 8888
Fax: +8610 6588 9999
E-mail: [email protected]
European Headquarters
Brocade Communications Switzerland Srl
Centre Swissair
Tour B - 4me tage
29, Route de l'Aroport
Case Postale 105
CH-1215 Genve 15
Switzerland
Tel: +41 22 799 5640
Fax: +41 22 799 5641
E-mail: [email protected]
Asia-Pacific Headquarters
Brocade Communications Systems Co., Ltd. (Shenzhen WFOE)
Citic Plaza
No. 233 Tian He Road North
Unit 1308 13th Floor
Guangzhou, China
Tel: +8620 3891 2000
Fax: +8620 3891 2111
E-mail: [email protected]
Title Publication Number Summary of Changes Date
Brocade VA-40FC Hardware Reference Manual 53-1001540-01 New document August 2009
Brocade VA-40FC Hardware Reference Manual 53-1001540-02 Update document for
Release 6.4.
March 2010
Brocade VA-40FC Hardware Reference Manual 53-1001540-03 BSMI compliance
statement updated.
October 2011
Brocade VA-40FC Hardware Reference Manual 53-1001540-04 Chinese regulatory
statement added
May 2012
Brocade VA-40FC Hardware Reference Manual iii
53-1001540-04
Contents
About This Document
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Whats new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Getting technical help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Chapter 1 Brocade VA-40FC Introduction
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Brocade VA-40FC overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Port side of the Brocade VA-40FC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Non-port side of the Brocade VA-40FC . . . . . . . . . . . . . . . . . . . . . . . . 4
Field replaceable units (FRUs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ports on Demand license . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ISL trunking groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Fabric OS Native and Access Gateway modes . . . . . . . . . . . . . . . . . . 6
Disabling and enabling Access Gateway mode . . . . . . . . . . . . . . 7
Chapter 2 Brocade VA-40FC Installation and Configuration
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Items included with the Product Name . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation and safety considerations. . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Environmental considerations . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cabinet considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Recommendations for cable management . . . . . . . . . . . . . . . . 11
Items required for installation. . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing a standalone Product Name . . . . . . . . . . . . . . . . . . . . . . . 12
Cabinet installation for a Product Name . . . . . . . . . . . . . . . . . . . . . . 12
iv Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Product Name configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Providing power to the switch . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Creating a serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Switch IP address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Date and time settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Chapter 3 Brocade VA-40FC Operation
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Powering the Brocade VA-40FC on and off . . . . . . . . . . . . . . . . . . . . 19
LED activity interpretation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Brocade VA-40FC LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
LED locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
LED Patterns. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
POST and boot specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Interpreting POST results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Maintaining the Brocade VA-40FC. . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Installing an SFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Diagnostic tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Field Replaceable Units (FRUs). . . . . . . . . . . . . . . . . . . . . . . . . . 26
Power supply/fan assembly FRU replacement . . . . . . . . . . . . . 26
Managing the Brocade VA-40FC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Appendix A Brocade VA-40FC Specifications
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Access Gateway default port mapping . . . . . . . . . . . . . . . . . . . . . . . 27
Switch components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Weight and physical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Facility requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Power supply specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
General specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Data transmission ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Memory specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Fibre Channel port specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Serial port specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Brocade VA-40FC Hardware Reference Manual v
53-1001540-04
Regulatory compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
FCC warning (US only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
KCC statement (Republic of Korea) . . . . . . . . . . . . . . . . . . . . . . 33
VCCI statement Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Power cords (Japan Denan). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
China statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
BSMI statement (Taiwan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
CE statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Canadian requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Laser compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
RTC battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Regulatory certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Environmental regulation compliance. . . . . . . . . . . . . . . . . . . . . . . . 38
China RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Index
vi Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Brocade VA-40FC Hardware Reference Manual vii
53-1001540-04
About This Document
In this chapter
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Whats new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Getting technical help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
How this document is organized
This document is organized to help you find the information that you want as quickly and easily as
possible.
The document contains the following components:
Chapter 1, Brocade VA-40FC Introduction, provides an overview of the Product Name switch,
a feature list, and a look at the appearance of the switch.
Chapter 2, Brocade VA-40FC Installation and Configuration, provides the information needed
to install the switch into your network.
Chapter 3, Brocade VA-40FC Operation, discusses the day-to-day operational procedures for
using the switch.
Appendix A, Brocade VA-40FC Specifications, provides tables of physical, environmental, and
general specifications, helpful for quick lookup.
The Index points you to the exact pages on which specific information is located.
Supported hardware and software
Although many different software and hardware configurations are tested and supported by
Brocade Communications Systems, Inc. for Fabric OS v6.2.x, documenting all possible
configurations and scenarios is beyond the scope of this document.
This document is specific to the Brocade VA-40FC and Fabric OS vx.x.x. To obtain information about
a Fabric OS version other than vx.x.x, see the documentation specific to that OS version.
viii Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Whats new in this document
The Chinese regulatory statement has been added. China statement.
Document conventions
This section describes text formatting conventions and important notice formats used in this
document.
Text formatting
The narrative-text formatting conventions that are used are as follows:
bold text Identifies command names
Identifies the names of user-manipulated GUI elements
Identifies keywords and operands
Identifies text to enter at the GUI or CLI
italic text Provides emphasis
Identifies variables
Identifies paths and Internet addresses
Identifies document titles
code text Identifies CLI output
Identifies command syntax examples
For readability, command names in the narrative portions of this guide are presented in mixed
lettercase: for example, switchShow. In actual examples, command lettercase is often all
lowercase.
Command syntax conventions
Command syntax in this manual follows these conventions:
command Commands are printed in bold.
--option, option Command options are printed in bold.
-argument, arg Arguments.
[ ] Optional element.
variable Variables are printed in italics. In the help pages, values are underlined or
enclosed in angled brackets < >.
... Repeat the previous element, for example member[;member...]
value Fixed values following arguments are printed in plain font. For example,
--show WWN
| Boolean. Elements are exclusive. Example: --show -mode egress | ingress
Brocade VA-40FC Hardware Reference Manual ix
53-1001540-04
Notes, cautions, and warnings
The following notices and statements are used in this manual. They are listed below in order of
increasing severity of potential hazards.
NOTE
A note provides a tip, guidance or advice, emphasizes important information, or provides a reference
to related information.
ATTENTION
An Attention statement indicates potential damage to hardware or data.
CAUTION
A Caution statement alerts you to situations that can be potentially hazardous to you.
DANGER
A Danger statement indicates conditions or situations that can be potentially lethal or extremely
hazardous to you. Safety labels are also attached directly to products to warn of these conditions
or situations.
Key terms
For definitions specific to Brocade and Fibre Channel, see the Brocade Glossary.
For definitions of SAN-specific terms, visit the Storage Networking Industry Association online
dictionary at:
http://www.snia.org/education/dictionary
Notice to the reader
This document may contain references to the trademarks of the following corporations. These
trademarks are the properties of their respective companies and corporations.
These references are made for informational purposes only.
Corporation Referenced Trademarks and Products
IBM Corporation IBM, FICON, PowerPC
x Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Additional information
This section lists additional Brocade and industry-specific documentation that you might find
helpful.
Brocade resources
To get up-to-the-minute information, go to http://my.brocade.com and register at no cost for a user
ID and password.
For additional Brocade documentation, visit the Brocade SAN Info Center and click the Resource
Library location:
http://www.brocade.com
Release notes are available on the My Brocade website (http://my.brocade.com) and are also
bundled with the Fabric OS firmware.
Other industry resources
White papers, online demos, and data sheets are available through the Brocade Web site at
http://www.brocade.com/products/software.jhtml.
Best practice guides, white papers, data sheets, and other documentation is available through
the Brocade Partner Web site.
For additional resource information, visit the Technical Committee T11 Web site. This Web site
provides interface standards for high-performance and mass storage applications for Fibre
Channel, storage management, and other applications:
http://www.t11.org
For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web
site:
http://www.fibrechannel.org
Brocade VA-40FC Hardware Reference Manual xi
53-1001540-04
Getting technical help
Contact your switch support supplier for hardware, firmware, and software support, including
product repairs and part ordering. To expedite your call, have the following information available:
1. General Information
Technical Support contract number, if applicable
Switch model
Switch operating system version
Error numbers and messages received
supportSave command output
Detailed description of the problem, including the switch or fabric behavior immediately
following the problem, and specific questions
Description of any troubleshooting steps already performed and the results
Serial console and Telnet session logs
syslog message logs
2. Switch Serial Number
The switch serial number and corresponding bar code are provided on the serial number label,
as illustrated below.:
The serial number label is located as follows:
Brocade 300, 4100, 4900, 5100, 5300, 7500, 7500E, 7800, 8000, VA-40FC, and
Brocade Encryption SwitchOn the switch ID pull-out tab located inside the chassis on the
port side on the left
Brocade 5000On the switch ID pull-out tab located on the bottom of the port side of the
switch
Brocade 7600On the bottom of the chassis
Brocade 48000Inside the chassis next to the power supply bays
Brocade DCXOn the bottom right on the port side of the chassis
Brocade DCX-4SOn the bottom right on the port side of the chassis, directly above the
cable management comb
3. World Wide Name (WWN)
Use the wwn command to display the switch WWN.
If you cannot use the wwn command because the switch is inoperable, you can get the WWN
from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX,
access the numbers on the WWN cards by removing the Brocade logo plate at the top of the
non-port side of the chassis.
*FT00X0054E9*
FT00X0054E9
xii Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Document feedback
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and
completeness of this document. However, if you find an error or an omission, or you think that a
topic needs further development, we want to hear from you. Forward your feedback to:
[email protected]
Provide the title and version number of the document and as much detail as possible about your
comment, including the topic heading and page number and your suggestions for improvement.
Brocade VA-40FC Hardware Reference Manual 1
53-1001540-04
Chapter
1 Brocade VA-40FC Introduction
In this chapter
Brocade VA-40FC overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Port side of the Brocade VA-40FC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Non-port side of the Brocade VA-40FC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Field replaceable units (FRUs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ports on Demand license . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ISL trunking groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Fabric OS Native and Access Gateway modes. . . . . . . . . . . . . . . . . . . . . . . . . 6
Brocade VA-40FC overview
The Brocade VA-40FC is an Enterprise class 1U, 40-port Fibre Channel 1, 2, 4 or 8 Gbps Fibre
Channel switch that offers the next generation Brocade, single-chip architecture for Storage Area
Networks (SANs). The Brocade VA-40FC is designed to function in large-scale enterprise SANs and
can also fit the requirements of small to medium-sized work groups.
Because the Brocade VA-40FC has a slim 1U height and a high port count, you can use the Brocade
VA-40FC to create very dense fabrics in a relatively small space. With its flexible Ports On Demand
(POD) capability, the Brocade VA-40FC provides excellent overall value as the foundation of a SAN
with the ability to grow with an organizations SAN needs.
The Brocade VA-40FC is the latest mid-range offer from the Brocade family of entry-to-enterprise
products. It supports the following features:
Up to 40 ports of high-performance 8 Gbps technology and POD scaling from 24 to 32 or 40
ports.
Support for 1, 2, 4, and 8 Gbps auto-sensing Fibre Channel switch and router ports.
FICON
1
Dan hab yungh youq gij dienheiq diuzgen mbouj dwg diegndat
haenx ancienz sawjyungh.
[
]|
j
|)3|2OOOmJ)]]),
#
1
Dan hab yungh youq gij digih haijbaz 2000m doxroengz
haenx ancienz sawjyungh.
[
]|
j
{@5]@Q[|J (English translationdisconnect all power sources before service)
For non tropical use:
For altitude 2000 meter and below:
China-CCC Warning statements
English translation of above statement
This is a Class A product. In a domestic environment this product may cause radio interference, in
which case the user may be required to take adequate measures.
Warning for Class A:
36 Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Regulatory compliance A
BSMI statement (Taiwan)
Warning:
This is Class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
CE statement
ATTENTION
This is a Class A product. In a domestic environment, this product might cause radio interference,
and the user might be required to take corrective measures.
The standards compliance label on the Product Name contains the CE mark which indicates that
this system conforms to the provisions of the following European Council directives, laws, and
standards:
Electromagnetic Compatibility (EMC) Directive 2004/108/EEC
Low Voltage Directive (LVD) 2006/95/EC
EN50082-2/EN55024:1998 (European Immunity Requirements)
EN61000-3-2/JEIDA (European and Japanese Harmonics Spec)
EN61000-3-3
Canadian requirements
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations, ICES-003 Class A.
Laser compliance
This equipment contains Class 1 laser products and complies with FDA Radiation Performance
Standards, 21 CFR Subchapter I and the international laser safety standard IEC 825-2.
ATTENTION
Use only optical transceivers that are qualified by Brocade Communications Systems, Inc. and
comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter I,
and with IEC 825-2. Optical products that do not comply with these standards might emit light that
is hazardous to the eyes.
RTC battery
Brocade VA-40FC Hardware Reference Manual 37
53-1001540-04
Regulatory compliance A
ATTENTION
Do not attempt to replace the real-time clock (RTC) battery. There is danger of explosion if the battery
is incorrectly replaced or disposed of. Contact your switch supplier if the real-time clock begins to
lose time.
Electrical safety
ATTENTION
This switch might have more than one power cord. To reduce the risk of electric shock, disconnect
both power cords before servicing.
ATTENTION
Connect the power cord only to a grounded outlet.
ATTENTION
This product is designed for an IT power system with phase-to-phase voltage of 230V. After operation
of the protective device, the equipment is still under voltage if it is connected to an IT power system.
Regulatory certifications
Table 11 lists the EMC compatibility for the Product Name.
TABLE 11 EMC (electromagnetic compatibility)
Country Safety EMC
United States Bi_Nat UL/CSA 60950-1 1st Ed or
latest
ANSI C63.4
Canada Bi_Nat UL/CSA 60950-1 1st Ed or
latest
ICES-003 Class A
Japan CISPR22 and JEIDA (Harmonics)
European Community EN60950-1 or latest EN55022 and EN55024
Australia/New Zealand EN55022 or CISPR22 or AS/NZS
CISPR22
Argentina IEC60950-1 or latest
Russian Federation IEC60950-1 or latest 51318.22-99 and 51318.24.99
Korea KN22 and KN24
China (PS only) GB4943-2001 and
GB9254-1998 or latest
GB17625.1-2003 or latest
Taiwan (PS only) CNS 14336(94) or latest CNS 13438(95) or latest
38 Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Environmental regulation compliance A
Environmental regulation compliance
This section describes the China RoHS environmental regulatory compliance requirements for
the Brocade VA-40FC switch.
China RoHS
The contents included in this section are per the requirements of the People's Republic of China-
Management Methods for Controlling Pollution by Electronic Information products.
j'
] RoHS
7[]{j[)|]],jj||[
]
Brocade VA-40FC Hardware Reference Manual 39
53-1001540-04
Environmental regulation compliance A
Environmental protection use period (EPUP) disclaimer
In no event do the EPUP logos shown on the product and FRUs alter or expand that warranty that
Brocade provides with respect to its products as set forth in the applicable contract between
Brocade and its customer. Brocade hereby disclaims all other warranties and representations with
respect to the information contained on this CD including the implied warranties of merchantability,
fitness for a particular purposes and non-infringement.
The EPUP assumes that the product will be used under normal conditions in accordance with the
operating manual of the product.
TS/HS dual language sheet
In accordance with China's Management Measures on the Control of Pollution caused by Electronic
Information products (Decree No. 39 by the Ministry of Information Industry), the following
information is provided regarding the names and concentration level of Hazardous substances (HS)
which may be contained in this product.
TABLE 12 China ROHS hazardous substances/toxic substances (HS/TS) concentration chart
Name of the
Component
Hazardous/Toxic Substance/Elements
Lead (PB) Mercury
(Hg)
Cadmium
(CD)
Hexavalent
Chromium
(CR6+)
Polybrominated
Biphenyl (PBB)
Polybrominated
Diphenyl Ether
(PBDE)
Fibre Channel
Switch
X O O O O O
Fan, Blower
assemblies
X O O O O O
PCBA cards X O O O O O
Power Supply kit X O O O O O
SFPs (optical
cable
connectors)
X O O O O O
Sheet Metal X O O O O O
Chassis
Assembly
X O O O O O
Mechanical
brackets and
Slides
X O O O O O
Slot Filler X O O O O O
']))| (EPUP) )|
EPUP |],| FRU [[], Brocade
]j][|,],] Brocade
,)|)[j[){]|][] CD
[|];|,.,|)[),|(j|,[|]jBr
ocade ])|7,)[]|[]|)]j||]|
EPUP ]|,])]|[;),,
40 Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Environmental regulation compliance A
X indicates that the concentration of such hazardous/toxic substance in all the units of
homogeneous material of such component is higher than the SJ/T11363-2006 Requirements for
Concentration Limits.
O indicates that no such substances are used or that the concentration is within the
aforementioned limits.
Cable
management
tray
X O O O O O
Cable Comb O O O O O O
Cables and
power cords
O O O O O O
Replacement
Doors
X O O O O O
Software/
Documentation
CDs
O O O O O O
TABLE 12 China ROHS hazardous substances/toxic substances (HS/TS) concentration chart (Continued)
Name of the
Component
Hazardous/Toxic Substance/Elements
Lead (PB) Mercury
(Hg)
Cadmium
(CD)
Hexavalent
Chromium
(CR6+)
Polybrominated
Biphenyl (PBB)
Polybrominated
Diphenyl Ether
(PBDE)
Brocade VA-40FC Hardware Reference Manual 41
53-1001540-04
Environmental regulation compliance A
42 Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Environmental regulation compliance A
Brocade VA-40FC Hardware Reference Manual 43
53-1001540-04
Index
A
access
NTP, 18
Access Gateway mode
verifying, 8
access gateway mode, 6
default port mapping, 27
accessory kit, 9
B
bandwidth, aggregate, 30
Brocade Advanced Web Tools, 27
Brocade Fabric Manager, 27
Brocade ISL Trunking, 4, 6
BSMI statement (Chinese), 36
BSMI statement (Taiwan), 36
C
Canadian requirements, 36
CE statement, 36
China RoHS, 38
class
Fibre Channel classes supported, 30
Command line interface (CLI), 27
commands
ag --modeShow, 8
components, switch, 28
configuring
date and time, 15
NTP, 18
configuring the Brocade VA-40FC, 13
D
Data Center Fabric Manager, 27
date, 16
date and time, 15
diagnostic tests
about, 25
E
E_Ports, 6
EIA rack
requirements, 29
electrical safety, 37
environmental requirements, 30
event
date and time, 15
F
F_Ports, 6
FCC warning (US only), 33
Fibre Channel classes, supported, 30
Fibre Channel ports
specifications, 31
Field replaceable units (FRUs), 5
FL_Ports, 6
front panel
LEDs, 19
I
installing a Brocade VA-40FC into an EIA cabinet, 12
installing a stand-alone Brocade VA-40FC, 12
installing an SFP, 24
interpreting POST results, 23
IP over Fibre Channel (FC-IP), 30
ISL trunking groups, 6
items required for installation, 11
44 Brocade VA-40FC Hardware Reference Manual
53-1001540-04
K
KCC statement (Republic of Korea), 33
L
laser compliance, 36
latency, 30
LEDs
interpreting, 19
on front panel, 19
local clock, 18
LOCL, 18
logging
timestamp, 15
M
Management Server, 27
monitoring
through LED activity, 19
N
NTP
access, 18
P
physical dimensions of switch, 28
port
configurable types, 30
Ethernet port, 28
Fibre Channel port, 31
serial port, 28, 32
trunking, 4, 6
port numbering, 4
port status LEDs, 19
Ports On Demand, 5
ports, enabling, 5
ports, numbering, 4
POST, 6
error messages, 23
interpreting, 23
POST and boot specifications, 23
power status LED, 19
power supply
general information, 28
specifications, 29
power supply status LED, 19
protocol, ANSI, 30
provide power to the switch, 13
R
rack
requirements, 29
recommendations for cable management, 11
regulatory certifications, 37
regulatory compliance, 32
requirements
airflow, 29
electrical, 29
environmental, 29, 30
facility, 29
rack, 29
shock and vibration, 30
temperature and humidity, 30
RJ-45 connector, 28
RS-232 connector, 28
RTC battery, 36
S
serial port
specifications, 32
setting
time zone, 17
setting the date and time, 15
setting the IP address, 14
setting the switch date and time, 15
Setting time zones, 17
settings
date and time, 15
SNMP, 27
specifications
Fibre Channel ports, 31
general, 30
power supply, 29
serial port, 32
Brocade VA-40FC Hardware Reference Manual 45
53-1001540-04
switch
components, 28
physical dimensions, 28
weight, 28
system status LED, 19
T
temperature requirements, 30
tests, diagnostic, 25
time, 15
time and date, 15
Time zones, 15
time zones, 15
trunking
about, 4, 6
tsclockserver, 17, 18
tsTimeZone, 17
V
VCCI statement, 33
W
weight, switch, 28
46 Brocade VA-40FC Hardware Reference Manual
53-1001540-04