Next Issue
Volume 7, March
Previous Issue
Volume 6, September
 
 

Chemosensors, Volume 6, Issue 4 (December 2018) – 25 articles

  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list.
  • You may sign up for e-mail alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.
Order results
Result details
Section
Select all
Export citation of selected articles as:
14 pages, 4063 KiB  
Article
Resistive Low-Temperature Sensor Based on the SiO2ZrO2 Film for Detection of High Concentrations of NO2 Gas
by Tatiana N. Myasoedova, Tatiana S. Mikhailova, Galina E. Yalovega and Nina K. Plugotarenko
Chemosensors 2018, 6(4), 67; https://doi.org/10.3390/chemosensors6040067 - 19 Dec 2018
Cited by 11 | Viewed by 3763
Abstract
The SiO2ZrO2 composite films were prepared by means of sol-gel technology and characterized by scanning electron microscopy, energy dispersive X-ray (EDX) analysis, and X-ray diffraction. The presence of the stable monoclinic ZrO2 with an impurity of tetragonal phases is [...] Read more.
The SiO2ZrO2 composite films were prepared by means of sol-gel technology and characterized by scanning electron microscopy, energy dispersive X-ray (EDX) analysis, and X-ray diffraction. The presence of the stable monoclinic ZrO2 with an impurity of tetragonal phases is shown. The film surface is characterized by the presence of ZrOCl2·6H2O or ZrCl(OH)/ZrCl(OH)2 grains. The crystallite size negligibly depends on the annealing temperature of the film and amount to 10–12 nm and 9–12 nm for the films thermally treated at 200 °C and 500 °C, respectively. The film’s resistance is rather sensitive to the presence of NO2 impurities in the air at a low operating temperature (25 °C). Accelerated stability tests of the initial resistance showed high stability and reproducibility of the sensor based on the SiO2ZrO2 film thermally treated at 500 °C. Full article
(This article belongs to the Special Issue Thin Film Based Sensors)
Show Figures

Figure 1

15 pages, 3064 KiB  
Review
Inkjet-Printed Wireless Chemiresistive Sensors—A Review
by Melinda Hartwig, Ralf Zichner and Yvonne Joseph
Chemosensors 2018, 6(4), 66; https://doi.org/10.3390/chemosensors6040066 - 14 Dec 2018
Cited by 37 | Viewed by 6712
Abstract
Microelectronic devices have great potential to be integrated into the Internet of Things, bringing benefits to the environment, society, and economy. Especially, microscaled chemical sensors for environmental monitoring are of great interest since they can be manufactured by cost, time, and resource efficient [...] Read more.
Microelectronic devices have great potential to be integrated into the Internet of Things, bringing benefits to the environment, society, and economy. Especially, microscaled chemical sensors for environmental monitoring are of great interest since they can be manufactured by cost, time, and resource efficient inkjet printing technology. The aim of the present literature review is a reflection of state-of-the-art inkjet-printed chemiresistive sensors. It examines current material approaches used to realize printed chemiresistors, especially the challenges in the realisation of accurate electrode patterns as well as the deposition of various sensing materials by inkjet printing technology. The review will be completed by an overview of current research activities dealing with the integration of chemiresistive sensors into wireless applications. The result of this review confirms that during the last decades, the number of publications covering inkjet-printed chemical, especially chemiresistive, sensors and their introduction into the Internet of Things is growing. Furthermore, it reveals the need for further research regarding material science and printing technology compatibility to achieve reliable and reproducible chemiresistive sensors. Full article
(This article belongs to the Special Issue Printed Electroanalytical Tools for De-Centralized Applications)
Show Figures

Figure 1

13 pages, 1994 KiB  
Article
Raman Spectroscopy as an Assay to Disentangle Zinc Oxide Carbon Nanotube Composites for Optimized Uric Acid Detection
by Shawtik C. Das, Raja R. Pandey, Tuphan Devkota and Charles C. Chusuei
Chemosensors 2018, 6(4), 65; https://doi.org/10.3390/chemosensors6040065 - 12 Dec 2018
Cited by 11 | Viewed by 4882
Abstract
Refluxed zinc oxide (ZnO) nanoparticles (NPs) were prepared and attached to carboxylic acid functionalized multi-walled carbon nanotubes (COOH-MWNTs) via sonication. Practical optimization of electrocatalysts using sonication to disentangle a carbon nanotube composite for monitoring uric acid (UA) is shown. Monitoring UA is important [...] Read more.
Refluxed zinc oxide (ZnO) nanoparticles (NPs) were prepared and attached to carboxylic acid functionalized multi-walled carbon nanotubes (COOH-MWNTs) via sonication. Practical optimization of electrocatalysts using sonication to disentangle a carbon nanotube composite for monitoring uric acid (UA) is shown. Monitoring UA is important for the management of medical disorders. Selection of sonication time is a crucial step in producing the desired composite. We report, for the first time, the practical use of Raman spectroscopy to tune the sonication involved in tethering ZnO NPs to the multi-walled carbon nanotube (MWNT) surface. Maximum current for detecting UA, using chronoamperometry and cyclic voltammetry, correlated with the highest sp2-hybridized carbon signal, as seen in the integrated Raman G band peak areas denoting maximum COOH-MWNT disentanglement. An array of ZnO/COOH-MWNT composites were prepared ranging from 60 to 240 min sonication times. Optimum sonication (150 min) corresponded with both maximum measured current and MWNT disentanglement. The sensor was able to quantitatively and selectively measure UA at clinically relevant concentrations (100–900 μM) with rapid current response time (< 5 s). Full article
(This article belongs to the Special Issue Carbon Nanotube Sensors)
Show Figures

Figure 1

20 pages, 7187 KiB  
Article
Influence of Water Molecules on the Detection of Volatile Organic Compounds (VOC) Cancer Biomarkers by Nanocomposite Quantum Resistive Vapor Sensors vQRS
by Abhishek Sachan, Mickaël Castro, Veena Choudhary and Jean-Francois Feller
Chemosensors 2018, 6(4), 64; https://doi.org/10.3390/chemosensors6040064 - 10 Dec 2018
Cited by 13 | Viewed by 4074
Abstract
The anticipated diagnosis of various fatal diseases from the analysis of volatile organic compounds (VOC) biomarkers of the volatolome is the object of very dynamic research. Nanocomposite-based quantum resistive vapor sensors (vQRS) exhibit strong advantages in the detection of biomarkers, as they can [...] Read more.
The anticipated diagnosis of various fatal diseases from the analysis of volatile organic compounds (VOC) biomarkers of the volatolome is the object of very dynamic research. Nanocomposite-based quantum resistive vapor sensors (vQRS) exhibit strong advantages in the detection of biomarkers, as they can operate at room temperature with low consumption and sub ppm (part per million) sensitivity. However, to meet this application they need to detect some ppm or less amounts of biomarkers in patients’ breath, skin, or urine in complex blends of numerous VOC, most of the time hindered by a huge amount of water molecules. Therefore, it is crucial to analyze the effects of moisture on the chemo-resistive sensing behavior of carbon nanotubes based vQRS. We show that in the presence of water molecules, the sensors cannot detect the right amount of VOC molecules present in their environment. These perturbations of the detection mechanism are found to depend on the chemical interactions between water and other VOC molecules, but also on their competitive absorption on sensors receptive sites, located at the nanojunctions of the conductive architecture. This complex phenomenon studied with down to 12.5 ppm of acetone, ethanol, butanone, toluene, and cyclohexane mixed with 100 ppm of water was worth to investigate in the prospect of future developments of devices analysing real breath samples in which water can reach a concentration of 6%. Full article
(This article belongs to the Special Issue Electronic nose’s, Machine Olfaction and Electronic Tongue’s)
Show Figures

Figure 1

8 pages, 1779 KiB  
Article
Fluorinated Chromium Phthalocyanine Thin Films: Characterization and Ammonia Vapor Detection
by Hikmat Adnan Banimuslem and Burak Y. Kadem
Chemosensors 2018, 6(4), 63; https://doi.org/10.3390/chemosensors6040063 - 6 Dec 2018
Cited by 6 | Viewed by 3434
Abstract
Thin films of fluorinated chromium phthalocyanine were prepared using spin coating techniques and annealed at 100, 200, 300, and 400 °C. The prepared films were investigated using UV-Visible absorption spectroscopy, Raman spectroscopy, and atomic force microscopy. The band gap characteristics were evaluated to [...] Read more.
Thin films of fluorinated chromium phthalocyanine were prepared using spin coating techniques and annealed at 100, 200, 300, and 400 °C. The prepared films were investigated using UV-Visible absorption spectroscopy, Raman spectroscopy, and atomic force microscopy. The band gap characteristics were evaluated to study the difference electronic transitions between the prepared thin films under different annealing temperatures. Films were exposed to ammonia vapor in a concentration range of 40–100 ppm to demonstrate the gas sensing activity of prepared devices. Resistance versus voltage behavior was investigated upon the exposure of ammonia gas and the samples show an increase in the resistance towards the existence of ammonia molecules. The dependency of the sensors on time was studied to evaluate the response and recovery time, which were found to be 10 and 13 s respectively. Full article
(This article belongs to the Special Issue Thin Film Based Sensors)
Show Figures

Figure 1

17 pages, 3173 KiB  
Review
Advances on Sensors Based on Carbon Nanotubes
by Luca Camilli and Maurizio Passacantando
Chemosensors 2018, 6(4), 62; https://doi.org/10.3390/chemosensors6040062 - 6 Dec 2018
Cited by 131 | Viewed by 9312
Abstract
Carbon nanotubes have been attracting considerable interest among material scientists, physicists, chemists, and engineers for almost 30 years. Owing to their high aspect ratio, coupled with remarkable mechanical, electronic, and thermal properties, carbon nanotubes have found application in diverse fields. In this review, [...] Read more.
Carbon nanotubes have been attracting considerable interest among material scientists, physicists, chemists, and engineers for almost 30 years. Owing to their high aspect ratio, coupled with remarkable mechanical, electronic, and thermal properties, carbon nanotubes have found application in diverse fields. In this review, we will cover the work on carbon nanotubes used for sensing applications. In particular, we will see examples where carbon nanotubes act as main players in devices sensing biomolecules, gas, light or pressure changes. Furthermore, we will discuss how to improve the performance of carbon nanotube-based sensors after proper modification. Full article
(This article belongs to the Special Issue Carbon Nanotube Sensors)
Show Figures

Figure 1

11 pages, 2135 KiB  
Article
Hydrogen Sensing Properties of Co-Doped ZnO Nanoparticles
by Fatemeh Moosavi, Mohammad Ebrahim Bahrololoom, Ramin Kamjou, Ali Mirzaei, Salvatore Gianluca Leonardi and Giovanni Neri
Chemosensors 2018, 6(4), 61; https://doi.org/10.3390/chemosensors6040061 - 5 Dec 2018
Cited by 19 | Viewed by 4448
Abstract
In this study, the gas sensing properties of Co-doped ZnO nanoparticles (Co-ZnO NPs) synthesized via a simple sol-gel method are reported. The microstructure and morphology of the synthesized Co-ZnO NPs were characterized by X-ray diffraction (XRD) and transmission electron microscopy (TEM), respectively. Co-ZnO [...] Read more.
In this study, the gas sensing properties of Co-doped ZnO nanoparticles (Co-ZnO NPs) synthesized via a simple sol-gel method are reported. The microstructure and morphology of the synthesized Co-ZnO NPs were characterized by X-ray diffraction (XRD) and transmission electron microscopy (TEM), respectively. Co-ZnO NPs were then used for developing a conductometric gas sensor for the detection, at mild temperature, of low concentration of hydrogen (H2) in air. To evaluate the selectivity of the sensor, the sensing behavior toward some VOCs such as ethanol and acetone, which represent the most important interferents for breath hydrogen analysis, was also investigated in detail. Results reported demonstrated better selectivity toward hydrogen of the Co-ZnO NPs sensor when compared to pure ZnO. The main factors contributing to this behavior, i.e., the transition from n-type behavior of pristine ZnO to p-type behavior upon Co-doping, the modification of oxygen vacancies and acid-base characteristics have been considered. Hence, this study highlights the importance of Co doping of ZnO to realize a high performance breath hydrogen sensor. Full article
(This article belongs to the Special Issue Hierarchical Nanostructures for Gas Sensors)
Show Figures

Figure 1

28 pages, 3998 KiB  
Review
Carbon Nanostructures as a Multi-Functional Platform for Sensing Applications
by Rafael Gregorio Mendes, Paweł S. Wróbel, Alicja Bachmatiuk, Jingyu Sun, Thomas Gemming, Zhongfan Liu and Mark Hermann Rümmeli
Chemosensors 2018, 6(4), 60; https://doi.org/10.3390/chemosensors6040060 - 5 Dec 2018
Cited by 30 | Viewed by 8321
Abstract
The various forms of carbon nanostructures are providing extraordinary new opportunities that can revolutionize the way gas sensors, electrochemical sensors and biosensors are engineered. The great potential of carbon nanostructures as a sensing platform is exciting due to their unique electrical and chemical [...] Read more.
The various forms of carbon nanostructures are providing extraordinary new opportunities that can revolutionize the way gas sensors, electrochemical sensors and biosensors are engineered. The great potential of carbon nanostructures as a sensing platform is exciting due to their unique electrical and chemical properties, highly scalable, biocompatible and particularly interesting due to the almost infinite possibility of functionalization with a wide variety of inorganic nanostructured materials and biomolecules. This opens a whole new pallet of specificity into sensors that can be extremely sensitive, durable and that can be incorporated into the ongoing new generation of wearable technology. Within this context, carbon-based nanostructures are amongst the most promising structures to be incorporated in a multi-functional platform for sensing. The present review discusses the various 1D, 2D and 3D carbon nanostructure forms incorporated into different sensor types as well as the novel functionalization approaches that allow such multi-functionality. Full article
(This article belongs to the Special Issue Nanotechnology Efforts for Chemical Sensors)
Show Figures

Graphical abstract

15 pages, 7646 KiB  
Review
Functionalization of Bulk SiO2 Surface with Biomolecules for Sensing Applications: Structural and Functional Characterizations
by Emanuele Luigi Sciuto, Corrado Bongiorno, Antonino Scandurra, Salvatore Petralia, Tiziana Cosentino, Sabrina Conoci, Fulvia Sinatra and Sebania Libertino
Chemosensors 2018, 6(4), 59; https://doi.org/10.3390/chemosensors6040059 - 30 Nov 2018
Cited by 24 | Viewed by 4636
Abstract
Biomolecule immobilization on bulk silicon dioxide (SiO2) is an important aspect in the field of Si-based interfaces for biosensing. The approach used for surface preparation should guarantee not only the stable anchoring of biomolecules but also their structural integrity and biological [...] Read more.
Biomolecule immobilization on bulk silicon dioxide (SiO2) is an important aspect in the field of Si-based interfaces for biosensing. The approach used for surface preparation should guarantee not only the stable anchoring of biomolecules but also their structural integrity and biological functioning. In this paper, we review our findings on the SiO2 functionalization process to immobilize a variety of biomolecules, including glucose oxidase, horseradish peroxide, metallothionein, and DNA molecules. Morphological and chemical characterization of SiO2 surfaces after biomolecule immobilization using techniques already employed in the microelectronic industry are presented and discussed. Optical and spectrophotometric analysis revealed the preservation of biomolecules’ activity once they are anchored on the biointerface. Full article
(This article belongs to the Special Issue Nanotechnology Efforts for Chemical Sensors)
Show Figures

Figure 1

15 pages, 1451 KiB  
Article
Propylene Glycol Stabilizes the Linear Response of Glutamate Biosensor: Potential Implications for In-Vivo Neurochemical Monitoring
by Gaia Rocchitta, Andrea Bacciu, Paola Arrigo, Rossana Migheli, Gianfranco Bazzu and Pier Andrea Serra
Chemosensors 2018, 6(4), 58; https://doi.org/10.3390/chemosensors6040058 - 28 Nov 2018
Cited by 9 | Viewed by 3836
Abstract
L-glutamate is one the most important excitatory neurotransmitter at the central nervous system level and it is implicated in several pathologies. So, it is very important to monitor its variations, in real time in animal models’ brain. The present study aimed to develop [...] Read more.
L-glutamate is one the most important excitatory neurotransmitter at the central nervous system level and it is implicated in several pathologies. So, it is very important to monitor its variations, in real time in animal models’ brain. The present study aimed to develop and characterize a new amperometric glutamate biosensor design that exploits the selectivity of Glutamate Oxidase (GluOx) for l-glutamate, and the capability of a small molecule as propylene glycol (PG), never used before, to influence and extend the stability and the activity of enzyme. Different designs were evaluated by modifying the main components in their concentrations to find the most suitable design. Moreover, enzyme concentrations from 100 U/mL up to 200 U/mL were verified and different PG concentrations (1%, 0.1% and 0.05%) were tested. The most suitable selected design was Ptc/PPD/PEI(1%)2/GlutOx5/PG(0.1%) and it was compared to the same already described design loading PEDGE, instead of PG, in terms of over-time performances. The PG has proved to be capable of determining an over-time stability of the glutamate biosensor in particular in terms of linear region slope (LRS) up to 21 days. Full article
(This article belongs to the Special Issue Enzyme-Based Sensing Approaches)
Show Figures

Graphical abstract

13 pages, 3362 KiB  
Article
Development of a Cost-Effective Sensing Platform for Monitoring Phosphate in Natural Waters
by Andrew Donohoe, Gareth Lacour, Peter McCluskey, Dermot Diamond and Margaret McCaul
Chemosensors 2018, 6(4), 57; https://doi.org/10.3390/chemosensors6040057 - 27 Nov 2018
Cited by 16 | Viewed by 5251
Abstract
A sensing platform for the in situ, real-time analysis of phosphate in natural waters has been realised using a combination of microfluidics, colorimetric reagent chemistries, low-cost LED-based optical detection and wireless communications. Prior to field deployment, the platform was tested over a period [...] Read more.
A sensing platform for the in situ, real-time analysis of phosphate in natural waters has been realised using a combination of microfluidics, colorimetric reagent chemistries, low-cost LED-based optical detection and wireless communications. Prior to field deployment, the platform was tested over a period of 55 days in the laboratory during which a total of 2682 autonomous measurements were performed (854 each of sample, high standard and baseline, and 40 × 3 spiked solution measurements). The platform was subsequently field-deployed in a freshwater stream at Lough Rea, Co., Galway, Ireland, to track changes in phosphate over a five day period. During this deployment, 165 autonomous measurements (55 each of sample, high standard, and baseline) were performed and transmitted via general packet radio service (GPRS) to a web interface for remote access. Increases in phosphate levels at the sampling location coincident with rainfall events (min 1.45 µM to max 10.24 µM) were detected during the deployment. The response was found to be linear up to 50 µM PO43−, with a lower limit of detection (LOD) of 0.09 µM. Laboratory and field data suggest that despite the complexity of reagent-based analysers, they are reasonably reliable in remote operation, and offer the best opportunity to provide enhanced in situ chemical sensing capabilities. Modifications that could further improve the reliability and scalability of these platforms while simultaneously reducing the unit cost are discussed. Full article
Show Figures

Figure 1

18 pages, 16885 KiB  
Article
CuO Thin Films Functionalized with Gold Nanoparticles for Conductometric Carbon Dioxide Gas Sensing
by Robert Wimmer-Teubenbacher, Florentyna Sosada-Ludwikowska, Bernat Zaragoza Travieso, Stefan Defregger, Oeznur Tokmak, Jan Steffen Niehaus, Marco Deluca and Anton Köck
Chemosensors 2018, 6(4), 56; https://doi.org/10.3390/chemosensors6040056 - 22 Nov 2018
Cited by 11 | Viewed by 4185
Abstract
Metal oxides (MOx) are a well-established material for gas sensing. MOx-based gas sensors are sensitive to a wide variety of gases. Furthermore, these materials can be applied for the fabrication of low-cost and -power consumption devices in mass production. The market of carbon [...] Read more.
Metal oxides (MOx) are a well-established material for gas sensing. MOx-based gas sensors are sensitive to a wide variety of gases. Furthermore, these materials can be applied for the fabrication of low-cost and -power consumption devices in mass production. The market of carbon dioxide (CO 2 ) gas sensors is mainly dominated by infra-red (IR)-based gas sensors. Only a few MOx materials show a sensitivity to CO 2 and so far, none of these materials have been integrated on CMOS platforms suitable for mass production. In this work, we report a cupric oxide (CuO) thin film-based gas sensor functionalized with gold (Au) nanoparticles, which exhibits exceptional sensitivity to CO 2 . The CuO-based gas sensors are fabricated by electron beam lithography, thermal evaporation and lift-off process to form patterned copper (Cu) structures. These structures are thermally oxidized to form a continuous CuO film. Gold nanoparticles are drop-coated on the CuO thin films to enhance their sensitivity towards CO 2 . The CuO thin films fabricated by this method are already sensitive to CO 2 ; however, the functionalization of the CuO film strongly increases the sensitivity of the base material. Compared to the pristine CuO thin film the Au functionalized CuO film shows at equal operation temperatures (300 C) an increase of sensitivity towards the same gas concentration (e.g., 2000 ppm CO 2 ) by a factor of 13. The process flow used to fabricate Au functionalized CuO gas sensors can be applied on CMOS platforms in specific post processing steps. Full article
Show Figures

Figure 1

10 pages, 1112 KiB  
Review
Chemical Sensing Applications of Carbon Nanotube-Deposited Optical Fibre Sensors
by Yung Chuen Tan
Chemosensors 2018, 6(4), 55; https://doi.org/10.3390/chemosensors6040055 - 19 Nov 2018
Cited by 7 | Viewed by 4327
Abstract
Carbon nanotubes are unique one-dimensional materials which can experience a modification in their optical properties as the chemical composition of their ambient environment varies. One of the ways to interrogate these variations in optical properties is through the use of optical fibres. As [...] Read more.
Carbon nanotubes are unique one-dimensional materials which can experience a modification in their optical properties as the chemical composition of their ambient environment varies. One of the ways to interrogate these variations in optical properties is through the use of optical fibres. As such, their integration with optical fibre technology would potentially allow for the development of devices for various chemical sensing applications. Full article
(This article belongs to the Special Issue Carbon Nanotube Sensors)
Show Figures

Figure 1

13 pages, 2568 KiB  
Article
Nanostructured Nickel on Porous Carbon-Silica Matrix as an Efficient Electrocatalytic Material for a Non-Enzymatic Glucose Sensor
by Nassim Zahmouli, Silvia Marini, Mouna Guediri, Nabil Ben Mansour, Mokhtar Hjiri, Lassaad El Mir, Claudia Espro, Giovanni Neri and Salvatore Gianluca Leonardi
Chemosensors 2018, 6(4), 54; https://doi.org/10.3390/chemosensors6040054 - 16 Nov 2018
Cited by 18 | Viewed by 4537
Abstract
Nanostructured nickel on porous carbon-silica matrix (N-CS) has been synthesized using a sol gel process and subsequent pyrolysis treatment at a temperature of 650 °C. The morphology and microstructure of the N-CS sample has been investigated using XRD (X-ray Diffraction), SEM-EDS (Scanning Electron [...] Read more.
Nanostructured nickel on porous carbon-silica matrix (N-CS) has been synthesized using a sol gel process and subsequent pyrolysis treatment at a temperature of 650 °C. The morphology and microstructure of the N-CS sample has been investigated using XRD (X-ray Diffraction), SEM-EDS (Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy), and BET (Brunauer-Emmett-Teller) analysis. The synthesized nanocomposite has been used for developing NCS-modified screen-printed electrodes (NCS-SPCEs) and was applied in the electrochemical monitoring of glucose. After electrochemical activation, via cycling the modified electrode in a potential window from 0 to 0.8 V in 0.1 M KOH solution, the fabricated NCS-SPCEs electrodes were evaluated for the voltammetric and amperometric determination of glucose. The developed sensors showed good sensing performance towards glucose, displaying a sensitivity of 585 µA/mM cm−1 in the linear range from 0.05 to 1.5 mM, a detection limit lower than 30 µM with excellent selectivity. Full article
(This article belongs to the Special Issue Nanotechnology Efforts for Chemical Sensors)
Show Figures

Figure 1

12 pages, 2461 KiB  
Article
Electrochemical Study of Enzymatic Glucose Sensors Biocatalyst: Thermal Degradation after Long-Term Storage
by Marcelinus Christwardana and Domenico Frattini
Chemosensors 2018, 6(4), 53; https://doi.org/10.3390/chemosensors6040053 - 15 Nov 2018
Cited by 14 | Viewed by 4066
Abstract
The thermal degradation related to stability in long-term storage of a carbon nanotube-based biosensor has been investigated. The effect of storage temperature on detachment and denaturation of glucose oxidase (GOx) biocatalyst has been proved. The carbon nanotubes (CNTs) coated with polyethyleneimine (PEI) as [...] Read more.
The thermal degradation related to stability in long-term storage of a carbon nanotube-based biosensor has been investigated. The effect of storage temperature on detachment and denaturation of glucose oxidase (GOx) biocatalyst has been proved. The carbon nanotubes (CNTs) coated with polyethyleneimine (PEI) as entrapping polymer to attract more GOx to form a durable and layered CNT/PEI/GOx structure is used for long-term storage to minimize GOx detachment from the structure and minimize the possibility of enzyme and protein denaturation. After 120 days, the glucose response of the CNT/PEI/GOx biosensor stored under 4°C is preserved up to 66.7% of its initial value, while under a 25 °C storage the response is maintained up to 41.7%. The enzyme coverage activity of CNT/PEI/GOx stored at 4 °C and 25 °C has decreased by 31.1% and 51.4%, respectively. Denaturation and detachment of GOx are the common causes of thermal degradation in biosensors under improper storage temperatures, but the presence of PEI in the structure can slow-down these phenomena. Moreover, the electrons transfer constant of CNT/PEI/GOx biocatalyst stored at 4 °C and 25 °C were 7.5 ± 0.5 s−1 and 6.6 ± 0.3 s−1, respectively, indicating that also electrons mobility is damaged by detachment and denaturation of enzyme protein and the detection of glucose from the glucose oxidation reaction (GOR) is compromised. Full article
(This article belongs to the Special Issue Carbon Nanotube Sensors)
Show Figures

Figure 1

27 pages, 7389 KiB  
Review
Label-Free Biosensors Based onto Monolithically Integrated onto Silicon Optical Transducers
by Michailia Angelopoulou, Sotirios Kakabakos and Panagiota Petrou
Chemosensors 2018, 6(4), 52; https://doi.org/10.3390/chemosensors6040052 - 12 Nov 2018
Cited by 14 | Viewed by 4809
Abstract
The article reviews the current status of label-free integrated optical biosensors focusing on the evolution over the years of their analytical performance. At first, a short introduction to the evanescent wave optics is provided followed by detailed description of the main categories of [...] Read more.
The article reviews the current status of label-free integrated optical biosensors focusing on the evolution over the years of their analytical performance. At first, a short introduction to the evanescent wave optics is provided followed by detailed description of the main categories of label-free optical biosensors, including sensors based on surface plasmon resonance (SPR), grating couplers, photonic crystals, ring resonators, and interferometric transducers. For each type of biosensor, the detection principle is first provided followed by description of the different transducer configurations so far developed and their performance as biosensors. Finally, a short discussion about the current limitations and future perspectives of integrated label-free optical biosensors is provided. Full article
(This article belongs to the Special Issue Label-Free Biosensors and Chemical Sensors)
Show Figures

Figure 1

7 pages, 2958 KiB  
Communication
Fluorescence and Naked-Eye Detection of Pb2+ in Drinking Water Using a Low-Cost Ionophore Based Sensing Scheme
by Aron Hakonen and Niklas Strömberg
Chemosensors 2018, 6(4), 51; https://doi.org/10.3390/chemosensors6040051 - 8 Nov 2018
Cited by 13 | Viewed by 4484
Abstract
Drinking water contamination of lead from various environmental sources, leaching consumer products, and intrinsic water-pipe infrastructure is still today a matter of great concern. Therefore, new highly sensitive and convenient Pb2+ measurement schemes are necessary, especially for in-situ measurements at a low [...] Read more.
Drinking water contamination of lead from various environmental sources, leaching consumer products, and intrinsic water-pipe infrastructure is still today a matter of great concern. Therefore, new highly sensitive and convenient Pb2+ measurement schemes are necessary, especially for in-situ measurements at a low cost. Within this work dye/ionophore/Pb2+ co-extraction and effective water phase de-colorization was utilized for highly sensitive lead measurements and sub-ppb naked-eye detection. A low-cost ionophore Benzo-18-Crown-6-ether was used, and a simple test-tube mix and separate procedure was developed. Instrumental detection limits were in the low ppt region (LOD = 3, LOQ = 10), and naked-eye detection was 500 ppt. Note, however, that this sensing scheme still has improvement potential as concentrations of fluorophore and ionophore were not optimized. Artificial tap-water samples, leached by a standardized method, demonstrated drinking water application. Implications for this method are convenient in-situ lead ion measurements. Full article
(This article belongs to the Special Issue Chemical Sensors for Heavy Metals/Toxin Detection)
Show Figures

Figure 1

12 pages, 1645 KiB  
Communication
In Situ Metalorganic Deposition of Silver Nanoparticles on Gold Substrate and Square Wave Voltammetry: A Highly Efficient Combination for Nanomolar Detection of Nitrate Ions in Sea Water
by Emilie Lebon, Pierre Fau, Maurice Comtat, Myrtil L. Kahn, Alix Sournia-Saquet, Pierre Temple-Boyer, Brigitte Dubreuil, Philippe Behra and Katia Fajerwerg
Chemosensors 2018, 6(4), 50; https://doi.org/10.3390/chemosensors6040050 - 6 Nov 2018
Cited by 16 | Viewed by 4007
Abstract
The electro-reduction of nitrate ions in artificial sea water was investigated at a gold substrate (EAu) functionalized by silver nanoparticles (AgNPs). These AgNPs were generated in situ on the gold substrate by the direct decomposition of the metalorganic N,N′-diisopropylacetamidinate silver precursor [...] Read more.
The electro-reduction of nitrate ions in artificial sea water was investigated at a gold substrate (EAu) functionalized by silver nanoparticles (AgNPs). These AgNPs were generated in situ on the gold substrate by the direct decomposition of the metalorganic N,N′-diisopropylacetamidinate silver precursor [Ag(Amd)] in the liquid phase. Very small and well dispersed AgNPs were deposited on the gold electrode and then used as working electrode (EAu/AgNPs). Square wave voltammetry (SWV) was successfully employed to detect nitrate ions (NO3) with a detection limit (LOD) of 0.9 nmol∙L−1 in artificial sea water (pH = 6.0) without pre-concentration or pH adjustment. Full article
(This article belongs to the Special Issue Nanomaterial Based Chemical Sensors)
Show Figures

Graphical abstract

13 pages, 3784 KiB  
Article
Super Stable Pollution Gas Sensor Based on Functionalized 2D Boron Nitride Nanosheet Materials for High Humidity Environments
by Peter X. Feng, Ermides Chavez and Carlos Malca
Chemosensors 2018, 6(4), 49; https://doi.org/10.3390/chemosensors6040049 - 3 Nov 2018
Cited by 17 | Viewed by 3989
Abstract
We report on studies of new gas sensing devices to be used in high humidity environments. Highly thermal-stable, super hydrophobic 2-dimensional (2D) boron nitride nanosheets (BNNSs) functionalized with Pt nanoparticles were prepared and used as an active layer for the prototype. The morphologic [...] Read more.
We report on studies of new gas sensing devices to be used in high humidity environments. Highly thermal-stable, super hydrophobic 2-dimensional (2D) boron nitride nanosheets (BNNSs) functionalized with Pt nanoparticles were prepared and used as an active layer for the prototype. The morphologic surface, crystallographic structures and chemical compositions of the synthesized 2D materials were characterized by using optical microscope, scanning electron microscope (SEM), transmission electron microscope (TEM) and atomic force microscope (AFM) and Raman scattering, respectively. The experimental data reveals that high-quality BNNSs were prepared. A pair of Au electrodes were combined with a basic electrical circuit and the 2D sensing material to form high-performance gas sensors for the detection of pollution gases. The present structure is simple and the fabrication is easy and fast, which ensures the creation of a low-cost prototype with harsh (high humidity, high temperature) environment resistance and potential for miniaturization. The responses of the prototype to different target gases with different concentrations were characterized. The influences of the operating temperature and bias voltage effect on sensing performances were also investigated. The fabricated sensors appear to have high selectivity, high sensitivity and fast response to target gases. The sensing mechanism in the present case is attributed to the electron donation from the target gas molecules to the active layer, leading to the change of electrical properties on the surface of BNNS layer. Full article
Show Figures

Graphical abstract

9 pages, 861 KiB  
Review
Recent Progress on the Evolution of Pourbaix Sensors: Molecular Logic Gates for Protons and Oxidants
by David C. Magri
Chemosensors 2018, 6(4), 48; https://doi.org/10.3390/chemosensors6040048 - 31 Oct 2018
Cited by 8 | Viewed by 3227
Abstract
Recent progress in the area of molecular logic, in particular molecules capable of sensing for acidity and oxidizability, are gathered together in this short review. Originally proposed as AND logic gates that provide a high fluorescence output when simultaneously protonated and oxidized, the [...] Read more.
Recent progress in the area of molecular logic, in particular molecules capable of sensing for acidity and oxidizability, are gathered together in this short review. Originally proposed as AND logic gates that provide a high fluorescence output when simultaneously protonated and oxidized, the concept has been extended from two-input to three-input variants and to include molecules that function as INHIBIT logic gates. Photochemical concepts such as photoinduced electron transfer (PET) and internal charge transfer (ICT) are exploited as favorite design concepts. This review highlights the evolution of Pourbaix sensors with anthracene, pyrazoline, and naphthalimide fluorophores. Future applications abound in various disciplines from corrosion science, material science, geochemistry to cell imaging. Full article
Show Figures

Figure 1

11 pages, 1131 KiB  
Communication
IR-783 Labeling of a Peptide Receptor for ‘Turn-On’ Fluorescence Based Sensing
by Eun-A Kwak, LeNaiya Kydd, Butaek Lim and Justyn Jaworski
Chemosensors 2018, 6(4), 47; https://doi.org/10.3390/chemosensors6040047 - 16 Oct 2018
Cited by 6 | Viewed by 5132
Abstract
In this study, we examine a means for developing near-IR fluorescent sensors through streamlined, site-specific coupling with peptide-based receptors. As the penultimate step of solid-phase synthesis of a peptide-based receptor, we show a simple means of labeling the N’ terminus with the near [...] Read more.
In this study, we examine a means for developing near-IR fluorescent sensors through streamlined, site-specific coupling with peptide-based receptors. As the penultimate step of solid-phase synthesis of a peptide-based receptor, we show a simple means of labeling the N’ terminus with the near IR fluorophore IR-783 to afford a viable fluorescent sensor after cleavage from the resin. The proof-of-concept probe utilized a biotin mimetic peptide sequence as the receptive moiety. Here we revealed a “turn-on” fluorescence enhancement upon binding of the biotin mimetic probe to its intended streptavidin target. Not all peptide-receptive moieties tested were able to generate such an enhancement upon target binding, and as such, the rationale for the observed fluorescence response properties is discussed. Full article
(This article belongs to the Special Issue Aptamer Technologies)
Show Figures

Graphical abstract

22 pages, 2491 KiB  
Review
Advancements and Potential Applications of Microfluidic Approaches—A Review
by Ishtiaq Ahmed, Zain Akram, Mohammed Hussen Bule and Hafiz M. N. Iqbal
Chemosensors 2018, 6(4), 46; https://doi.org/10.3390/chemosensors6040046 - 15 Oct 2018
Cited by 21 | Viewed by 6472
Abstract
A micro-level technique so-called “microfluidic technology or simply microfluidic” has gained a special place as a powerful tool in bioengineering and biomedical engineering research due to its core advantages in modern science and engineering. Microfluidic technology has played a substantial role in numerous [...] Read more.
A micro-level technique so-called “microfluidic technology or simply microfluidic” has gained a special place as a powerful tool in bioengineering and biomedical engineering research due to its core advantages in modern science and engineering. Microfluidic technology has played a substantial role in numerous applications with special reference to bioscience, biomedical and biotechnological research. It has facilitated noteworthy development in various sectors of bio-research and upsurges the efficacy of research at the molecular level, in recent years. Microfluidic technology can manipulate sample volumes with precise control outside cellular microenvironment, at micro-level. Thus, enable the reduction of discrepancies between in vivo and in vitro environments and reduce the overall reaction time and cost. In this review, we discuss various integrations of microfluidic technologies into biotechnology and its paradigmatic significance in bio-research, supporting mechanical and chemical in vitro cellular microenvironment. Furthermore, specific innovations related to the application of microfluidics to advance microbial life, solitary and co-cultures along with a multiple-type cell culturing, cellular communications, cellular interactions, and population dynamics are also discussed. Full article
(This article belongs to the Special Issue Label-Free Biosensors and Chemical Sensors)
Show Figures

Figure 1

36 pages, 708 KiB  
Review
Applications of Electronic-Nose Technologies for Noninvasive Early Detection of Plant, Animal and Human Diseases
by Alphus Dan Wilson
Chemosensors 2018, 6(4), 45; https://doi.org/10.3390/chemosensors6040045 - 4 Oct 2018
Cited by 88 | Viewed by 9998
Abstract
The development of electronic-nose (e-nose) technologies for disease diagnostics was initiated in the biomedical field for detection of biotic (microbial) causes of human diseases during the mid-1980s. The use of e-nose devices for disease-diagnostic applications subsequently was extended to plant and animal hosts [...] Read more.
The development of electronic-nose (e-nose) technologies for disease diagnostics was initiated in the biomedical field for detection of biotic (microbial) causes of human diseases during the mid-1980s. The use of e-nose devices for disease-diagnostic applications subsequently was extended to plant and animal hosts through the invention of new gas-sensing instrument types and disease-detection methods with sensor arrays developed and adapted for additional host types and chemical classes of volatile organic compounds (VOCs) closely associated with individual diseases. Considerable progress in animal disease detection using e-noses in combination with metabolomics has been accomplished in the field of veterinary medicine with new important discoveries of biomarker metabolites and aroma profiles for major infectious diseases of livestock, wildlife, and fish from both terrestrial and aquaculture pathology research. Progress in the discovery of new e-nose technologies developed for biomedical applications has exploded with new information and methods for diagnostic sampling and disease detection, identification of key chemical disease biomarkers, improvements in sensor designs, algorithms for discriminant analysis, and greater, more widespread testing of efficacy in clinical trials. This review summarizes progressive advancements in utilizing these specialized gas-sensing devices for numerous diagnostic applications involving noninvasive early detections of plant, animal, and human diseases. Full article
(This article belongs to the Special Issue Electronic nose’s, Machine Olfaction and Electronic Tongue’s)
Show Figures

Graphical abstract

20 pages, 3295 KiB  
Review
Stochastic and Temporal Models of Olfactory Perception
by Thomas P. Hettinger and Marion E. Frank
Chemosensors 2018, 6(4), 44; https://doi.org/10.3390/chemosensors6040044 - 26 Sep 2018
Cited by 3 | Viewed by 3889
Abstract
Olfactory systems typically process signals produced by mixtures composed of very many natural odors, some that can be elicited by single compounds. The several hundred different olfactory receptors aided by several dozen different taste receptors are sufficient to define our complex chemosensory world. [...] Read more.
Olfactory systems typically process signals produced by mixtures composed of very many natural odors, some that can be elicited by single compounds. The several hundred different olfactory receptors aided by several dozen different taste receptors are sufficient to define our complex chemosensory world. However, sensory processing by selective adaptation and mixture suppression leaves only a few perceptual components recognized at any time. Thresholds determined by stochastic processes are described by functions relating stimulus detection to concentration. Relative saliences of mixture components are established by relating component recognition to concentration in the presence of background components. Mathematically distinct stochastic models of perceptual component dominance in binary mixtures were developed that accommodate prediction of an appropriate range of probabilities from 0 to 1, and include errors in identifications. Prior short-term selective adaptation to some components allows temporally emergent recognition of non-adapted mixture-suppressed components. Thus, broadly tuned receptors are neutralized or suppressed by activation of other more efficacious receptors. This ‘combinatorial’ coding is more a process of subtraction than addition, with the more intense components dominating the perception. It is in this way that complex chemosensory mixtures are reduced to manageable numbers of odor notes and taste qualities. Full article
(This article belongs to the Special Issue Electronic nose’s, Machine Olfaction and Electronic Tongue’s)
Show Figures

Figure 1

20 pages, 4207 KiB  
Review
Microfluidic Devices for Label-Free DNA Detection
by Gorachand Dutta, Joshua Rainbow, Uros Zupancic, Sotirios Papamatthaiou, Pedro Estrela and Despina Moschou
Chemosensors 2018, 6(4), 43; https://doi.org/10.3390/chemosensors6040043 - 25 Sep 2018
Cited by 40 | Viewed by 9154
Abstract
Sensitive and specific DNA biomarker detection is critical for accurately diagnosing a broad range of clinical conditions. However, the incorporation of such biosensing structures in integrated microfluidic devices is often complicated by the need for an additional labelling step to be implemented on [...] Read more.
Sensitive and specific DNA biomarker detection is critical for accurately diagnosing a broad range of clinical conditions. However, the incorporation of such biosensing structures in integrated microfluidic devices is often complicated by the need for an additional labelling step to be implemented on the device. In this review we focused on presenting recent advances in label-free DNA biosensor technology, with a particular focus on microfluidic integrated devices. The key biosensing approaches miniaturized in flow-cell structures were presented, followed by more sophisticated microfluidic devices and higher integration examples in the literature. The option of full DNA sequencing on microfluidic chips via nanopore technology was highlighted, along with current developments in the commercialization of microfluidic, label-free DNA detection devices. Full article
(This article belongs to the Special Issue Label-Free Biosensors and Chemical Sensors)
Show Figures

Figure 1

Previous Issue
Next Issue
Back to TopTop