CERN Accelerating science

CERN Document Server 2,043 elementer funnet  1 - 10nesteslutt  gå til element: Søket tok 0.60 sekunder. 
1.
Construction and Test of MDT Chambers for the ATLAS Muon Spectrometer / Bauer, F. (Munich, Max Planck Inst.) ; Bratzler, U. (Munich, Max Planck Inst.) ; Dietl, H. (Munich, Max Planck Inst.) ; Kroha, H. (Munich, Max Planck Inst.) ; Lagouri, Th. (Munich, Max Planck Inst.) ; Manz, A. (Munich, Max Planck Inst.) ; Ostapchuk, A. (Munich, Max Planck Inst.) ; Richter, Robert (Munich, Max Planck Inst.) ; Schael, S. (Munich, Max Planck Inst.) ; Chouridou, S. (Munich U.) et al.
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. [...]
MPP-2016-071; arXiv:1604.02000; MPI-PHE-2000-11; MPP-2016-071; MPI-PHE-2000-11.- 2001 - 5 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 461 (2001) 17-20 Preprint: PDF; External link: Preprint
In : 8th Pisa Meeting on Advanced Detectors : Frontier Detectors for Frontier Physics, La Biodola, Italy, 21 - 27 May 2000, pp.17-20
2.
Construction and test of MDT chambers for the ATLAS muon spectrometer / Bauer, F (Munich, Max Planck Inst.) ; Bratzler, U (Munich, Max Planck Inst.) ; Dietl, H (Munich, Max Planck Inst.) ; Kroha, H (Munich, Max Planck Inst.) ; Lagouri, T (Munich, Max Planck Inst.) ; Manz, A (Munich, Max Planck Inst.) ; Ostapchuk, A Ya (Munich, Max Planck Inst.) ; Richter, R (Munich, Max Planck Inst.) ; Schael, S (Munich, Max Planck Inst.) ; Chouridou, S (Munich U.) et al.
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side ofa space frame carrying an optical monitoring system to correct fordeformations. [...]
ATL-MUON-2001-006 ; MPI-PhE-2000-11 ; MPI-Report.
- 2001. - 7 p.
Full text - Access to fulltext document - Access to fulltext document - Access to fulltext document
3.
Construction and test of the precision drift chambers for the ATLAS muon spectrometer / Bauer, F. (Munich, Max Planck Inst.) ; Blum, W. (Munich, Max Planck Inst.) ; Bratzler, U. (Munich, Max Planck Inst.) ; Dietl, H. (Munich, Max Planck Inst.) ; Kotov, S. (Munich, Max Planck Inst.) ; Kroha, H. (Munich, Max Planck Inst.) ; Lagouri, T. (Munich, Max Planck Inst.) ; Manz, A. (Munich, Max Planck Inst.) ; Ostapchuk, A. (Munich, Max Planck Inst.) ; Richter, Robert (Munich, Max Planck Inst.) et al.
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 mum with a single-tube resolution of at least 80 mum und a sense wire positioning accuracy of 20 mum (rms). [...]
arXiv:1604.02259; MPI-PHE-2000-029; MPP-2016-073; MPI-PHE-2000-029; MPP-2016-073.- 2001 - 7 p. - Published in : IEEE Trans. Nucl. Sci. 48 (2001) 302 Fulltext: PDF; External link: Preprint
In : 47th IEEE Nuclear Science Symposium and Medical Imaging Conference, Lyons, France, 15 - 20 Oct 2000, pp.5/11-5/15 (v.1)
4.
Quality Assurance and Control Reference Document for ATLAS MDT Chamber Construction / Kroha, H (Munich, Max Planck Inst.)
Guidelines for the implementation of the quality assurance and quality control procedures during the construction of the Monitored Drift Tube (MDT) Chambers for the ATLAS Muon Spectrometer [...]
ATL-MUON-2000-008.
- 1999.
Access to fulltext document - Access to fulltext document
5.
Development of Fast High-Resolution Muon Drift-Tube Detectors for High Counting Rates / Bittner, B. (Munich, Max Planck Inst.) ; Dubbert, J. (Munich, Max Planck Inst.) ; Horvat, S. (Munich, Max Planck Inst.) ; Kortner, O. (Munich, Max Planck Inst.) ; Kroha, H. (Munich, Max Planck Inst.) ; Legger, F. (Munich, Max Planck Inst.) ; Richter, R. (Munich, Max Planck Inst.) ; Adomeit, S. (Munich U.) ; Biebel, O. (Munich U.) ; Engl, A. (Munich U.) et al.
Pressurized drift-tube chambers are e?cient detectors for high-precision tracking over large areas. The Monitored Drift-Tube (MDT) chambers of the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) reach a spatial resolution of 35 micons and almost 100% tracking e?ciency with 6 layers of 30 mm diameter drift tubes operated with Ar:CO2 (93:7) gas mixture at 3 bar and a gas gain of 20000. [...]
arXiv:1603.09516; MPP-2010-091.- 2011 - 4 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 628 (2011) 154-157 Fulltext: PDF; External link: Preprint
In : 12th Vienna Conference on Instrumentation, Vienna, Austria, 15 - 20 Feb 2010, pp.154-157
6.
The first precision drift tube chambers for the ATLAS muon spectrometer / Bauer, F (Munich, Max Planck Inst.) ; Blum, W (Munich, Max Planck Inst.) ; Dietl, HMunich, Max Planck Inst. ; Kotov, S AMunich, Max Planck Inst. ; Kroha, HMunich, Max Planck Inst. ; Manz, AMunich, Max Planck Inst. ; Ostapchuk, A YaMunich, Max Planck Inst. ; Richter, RMunich, Max Planck Inst. ; Schael, SMunich, Max Planck Inst. ; Chouridou, S (Munich U.) et al.
The muon spectrometer of the ATLAS detector for the Large Hadron Collider is designed to provide a muon transverse momentum resolution of 2-10% for momenta between 6 GeV and 1 TeV over a pseudo-rapidity range of |eta |< 2.7. [...]
ATL-MUON-2001-004 ; MPI-PHE-2001-03.
- 2002. - 9 p.
Access to fulltext document - Access to fulltext document
7.
Construction and test of high precision drift-tube (sMDT) chambers for the ATLAS muon spectrometer / Nowak, Sebastian (Munich, Max Planck Inst.) ; Kortner, Oliver (Munich, Max Planck Inst.) ; Kroha, Hubert (Munich, Max Planck Inst.) ; Schwegler, Philipp (Munich, Max Planck Inst.) ; Sforza, Federico (Munich, Max Planck Inst.)
For the upgrade of the ATLAS muon spectrometer in March 2014 new muon tracking chambers (sMDT) with drift-tubes of 15 mm diameter, half of the value of the standard ATLAS Monitored Drift-Tubes (MDT) chambers, and 10~$\mu$m positioning accuracy of the sense wires have been constructed. The new chambers are designed to be fully compatible with the present ATLAS services but, with respect to the previously installed ATLAS MDT chambers, they are assembled in a more compact geometry and they deploy two additional tube layers that provide redundant rack information. [...]
arXiv:1407.0285.- 2014 - 4 p. - Published in : PoS TIPP2014 (2014) 302 Fulltext: PDF; External link: PoS server
In : International Conference on Technology and Instrumentation in Particle Physics 2014, Amsterdam, Netherlands, 2 - 6 Jun 2014, pp.302
8.
Upgrades of the ATLAS Muon Spectrometer with sMDT Chambers / Ferretti, C. (Michigan U.) ; Kroha, H. (Munich, Max Planck Inst.) /for the ATLAS Muon Collaboration
With half the drift-tube diameter of the Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer and otherwise unchanged operating parameters, small-diameter Muon Drift Tube (sMDT) chambers provide an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit. The chamber assembly time has been reduced by a factor of seven to one working day and the sense wire positioning accuracy improved by a factor of two to better than ten microns. [...]
arXiv:1603.09544.- 2016-07-11 - 3 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 824 (2016) 538-540 Fulltext: PDF; External link: Preprint
In : Frontier Detectors for Frontier Physics: 13th Pisa Meeting on Advanced Detectors, La Biodola, Isola D'elba, Italy, 24 - 30 May 2015, pp.538-540
9.
A Cosmic Ray Measurement Facility for ATLAS Muon Chambers / Biebel, O. (Munich U.) ; Binder, M. (Munich U.) ; Boutemeur, M. (Munich U.) ; Brandt, A. (Munich U.) ; Dubbert, J. (Munich U.) ; Duckeck, G. (Munich U.) ; Elmsheuser, J. (Munich U.) ; Fiedler, F. (Munich U.) ; Hertenberger, R. (Munich U.) ; Kortner, O. (Munich, Max Planck Inst.) et al.
Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. [...]
physics/0307147 ; LMU-ETP-2003-01 ; ATL-MUON-2004-004 ; LMU-ETP-2003-01.
- 2003. - 15 p.
Access to fulltext document - Access to fulltext document - Access to fulltext document - Access to fulltext - Access to fulltext - Full text
10.
Performance of New High-Precision Muon Tracking Detectors for the ATLAS Experiment / Kroha, Hubert (Munich, Max Planck Inst.) ; Kortner, Oliver (Munich, Max Planck Inst.) ; Schmidt-Sommerfeld, Korbinian (Munich, Max Planck Inst.) ; Takasugi, Eric (Munich, Max Planck Inst.)
The goals of the ongoing and planned ATLAS muon detector upgrades are to increase the acceptance for precision muon momentum measurement and triggering and to improve the rate capability of the muon chambers in the high-background regions corresponding to the increasing LHC luminosity. [...]
arXiv:1701.08971 ; MPP-2016-375.
- 2017. - 2 p.
Full text

Fant du ikke det du lette etter? Gjenta søket på andre tjenere:
recid:2145043 i Amazon
recid:2145043 i CERN EDMS
recid:2145043 i CERN Intranet
recid:2145043 i CiteSeer
recid:2145043 i Google Books
recid:2145043 i Google Scholar
recid:2145043 i Google Web
recid:2145043 i IEC
recid:2145043 i IHS
recid:2145043 i INSPIRE
recid:2145043 i ISO
recid:2145043 i KISS Books/Journals
recid:2145043 i KISS Preprints
recid:2145043 i NEBIS
recid:2145043 i SLAC Library Catalog