GAGEtrak 7.0.5 User Guide
GAGEtrak 7.0.5 User Guide
GAGEtrak 7.0.5 User Guide
7
The World’s #1 Calibration Management Software Solution
User Guide
®
User Guide
Calibration Management Software Version 7.0.5
CyberMetrics Corporation
1523 West Whispering Wind Drive, Suite 100
Phoenix, Arizona 85085
USA
www.cybermetrics.com
Entire Contents Copyright 1988-2016, CyberMetrics Corporation All Rights Reserved Worldwide. GT7.0.5-11292016
U.S. GOVERNMENT RESTRICTED RIGHTS
This software and documentation are provided with RESTRICTED RIGHTS. Use, duplication, or disclosure by the Government
is subject to restrictions as set forth in subdivision (b)(3)(ii) of The Rights in Technical Data and Computer Software clause at
252.227-7013. Contractor/manufacturer is CyberMetrics Corporation.
QUESTIONS
Should you have any questions concerning this agreement, or if you wish to contact CyberMetrics Corporation for any reason,
please contact us at:
CyberMetrics Corporation
1523 W. Whispering Wind Dr., Suite 100
Phoenix, Arizona 85085 USA
Toll-free: 1-800-777-7020 (USA) Direct: (480) 922-7300 Fax: (480) 922-7400
www.cybermetrics.com
TECHNICAL SUPPORT
Technical support is available during normal business hours, Mountain Standard Time:
1-800-777-7020 ext. 363
[email protected]
www.cybermetrics.com
Note: technical support cannot be provided unless the user has a current maintenance agreement.
TRADEMARK ACKNOWLEDGMENTS
All CyberMetrics Corporation products are trademarks or registered trademarks of CyberMetrics Corporation.
All other brand and product names are trademarks or registered trademarks of their respective holders.
SOFTWARE LICENSE
1. GRANT OF LICENSE. CyberMetrics grants to you the right to use one copy of the enclosed software program (the
“SOFTWARE”) on a single computer. If you wish to put the SOFTWARE on a network server, you must purchase the same number
of copies as computers attached to the network that use the SOFTWARE.
2. COPYRIGHT. The SOFTWARE is owned by CyberMetrics or its suppliers and is protected by United States copyright laws
and international treaty provisions. Therefore, you must treat the SOFTWARE like any other copyrighted material (e.g., a book or
musical recording) except that you may (a) make copies of the SOFTWARE solely for backup or archival purposes and (b) transfer
the software to hard disks provided that only one copy of the SOFTWARE is used at any time. You MAY NOT COPY the written
materials accompanying the SOFTWARE.
3. OTHER RESTRICTIONS. You may not rent or lease the SOFTWARE, but you may transfer the SOFTWARE and accompanying
written materials on a permanent basis provided you retain no copies and the recipient agrees to the terms of this Agreement.
LIMITED WARRANTY. CyberMetrics warrants that you may return the SOFTWARE and all accompanying written materials, for any
reason, for a full refund, for a period of 30 days from the date of receipt.
CUSTOMER REMEDIES. CyberMetrics’ entire liability and your exclusive remedy shall be, at CyberMetrics’ option, either (a) return
of the price paid or (b) repair or replacement of the SOFTWARE that does not meet CyberMetrics Limited Warranty and which
is returned to CyberMetrics with a copy of your invoice or receipt. This Limited Warranty is void if failure of the SOFTWARE has
resulted from accident, abuse or misapplication. Any replacement SOFTWARE will be warranted for the remainder of the original
warranty period or 30 days, whichever is longer.
NO OTHER WARRANTIES. CyberMetrics DISCLAIMS ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED, INCLUDING
BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH
RESPECT TO THE SOFTWARE, THE ACCOMPANYING WRITTEN MATERIALS and ANY ACCOMPANYING HARDWARE. THIS
LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS; YOU MAY HAVE OTHERS WHICH VARY FROM STATE TO STATE.
NO LIABILITY FROM CONSEQUENTIAL DAMAGES. In no event shall CyberMetrics, its distributors, its representatives or its suppliers
be liable for any damages whatsoever (including, without limitation, damages for the loss of business profits, business interruption,
loss of business information or other pecuniary loss) arising out of the use or inability to use this CyberMetrics product, even if
CyberMetrics has been advised of the possibility of such damages. Because some states do not allow the exclusion or limitation of
liability for consequential or incidental damages, the above limitation may not apply to you.
Table of Contents
User Guide Chapter One: Running GAGEtrak 15
Launching GAGEtrak................................................................................................................15
First-time Login.......................................................................................................................15
Changing Your Password...........................................................................................................16
Serial Number.........................................................................................................................17
Index 262
User Guide Chapter One:
Running GAGEtrak
Once you have installed GAGEtrak, it’s time to launch it.
Launching GAGEtrak
To launch GAGEtrak, double-click on the GAGEtrak shortcut icon that was placed on your desktop during installation or click the
Windows Start button and navigate to All Programs -> GAGEtrak 7.0 program group -> GAGEtrak 7.0.
First-time Login
GAGEtrak requires users to log in if you have installed the Standard Edition and activated security through Settings -> Security or if
you have installed the FDA Edition. The Login window shown below will appear:
Enter your User ID and Password and click OK. The default login for the FDA Edition is Default/1234.
Enter your User ID. GAGEtrak will require you to enter your old password and then enter and confirm your new password. Click OK.
You will receive a message that your password has been successfully entered and you’ll be logged into GAGEtrak.
In this window, you can enter or edit your serial number which is located within your product packaging. If you can’t find your serial
number, contact Technical Support at 1-800-777-7020 or [email protected].
Rather than repeating the same information in every section of this manual, we discuss these conventions only in this section.
You’ll find record-specific information, such as each record’s individual purpose, fields and special buttons in the parts of this
manual that discuss specific record types.
In the lower portion of the Dashboard, click the Additional Schedules Due tab to view the list of gages due. Click any column
header to sort the data by that field. Click the Select checkbox associated with a gage and click the View Gages button to go
directly to that gage record.
Master Tabs
A Master Tab feature has been implemented that permits multiple forms to be open simultaneously, permitting access to other
areas of the program without needing to close other open forms.
The text filters in the column controls in datasheet view increase search and sorting capabilities. In datasheet view, right-click a
column header and you’ll be presented with various filter options for that column of data. If you select Field Filter, you will be
presented with the filter window shown below.
Please note that if you are using an SQL database, the text filter screen(s) you see may differ from those above.
Icon Function
Click the Current Connection icon to view or edit the current database connection information. After filling out the
necessary information, click Save.
To switch back and forth between multiple saved connections, you would go to Saved Connections to select the desired
database. If you are connecting to a GAGEtrak database that has security enabled, you will need to log in with your
User ID and Password associated with that database.
Icon Function
Click the Email Settings icon; in the Email Settings window, enter the following information:
Email Method – select protocol for sending email between servers
SMTP Server – insert name of server
From Email – insert your email address
Remote Port – check with your System Administrator for an acceptable port number
Use Authentication – this is the process of identifying an individual, usually based on a User Name and Password
Test Settings to Email – performs validity of information entered in email setup; enter an email address and then click
the Send Test Email button.
Once your settings are complete, click OK to save the settings and close the window.
Click the Auto Cal Due Settings icon; in the ensuing window, configure auto email settings for the calibration due listing
report. When finished, click OK. These settings pertain to the Automatic Calibration Due Listing email event in Setup ->
Auto Email Header.
Remove or delete a record(s). GAGEtrak asks for a confirmation to make sure you really want to delete the record(s).
Cut your selection when editing field entries and store that text on the clipboard.
Copy your selection when editing field entries and store that text on the clipboard.
Display your records in Form View (the default presentation of your records). In Form View, you can see all of the fields
for a record, but you can see only one record at a time.
Display your records in Datasheet View (a tabular format). Datasheet View allows you to view many records at a time
(available only in certain record entry screens).
Show or hide selected column(s) of data in datasheet view.
Place your cursor in the field by which you want to filter records and then click this icon. You can select an existing
value or go into Text Filters to specify criteria, such as “begins with” CAL, contains “micrometer”, etc.
Use the Quick Filter to quickly find records based on a simple search.
Use the Advanced Filter to search for a group of records that match specific criteria. You can save and name the
search criteria for later use; click Open Search to open a saved search.
Click the Show All Records icon to clear any filter and show all records.
Sort all of your records in ascending order (numbers show before letters).
Sort all of your records in descending order (numbers show after letters).
This option allows you to send selected data via email in a variety of file types to Microsoft Outlook (or any MAPI
compatible mail program). The output includes sub-forms and sub-reports. The file format and appearances are the
same as those described above for the Output commands.
If the date field is blank when the calendar is opened, then the date on the calendar will be the current date. If there is a date in
the field, the calendar will show that date. To select today’s date, click Today. To select another date, click the left or right arrow
buttons to scroll to the desired month and year and then click the day of the month. The selected date will populate the date field.
Minimize/Maximize/Restore/Close Buttons
Use these buttons, located in the upper right corner of the application window, to maximize the window’s size to the largest size
allowed or to minimize the window to an icon. If you maximize the window, then the Maximize button changes to the Restore
button. Click this button to return the window to its original size.
Drop-down Lists
Drop-down list buttons indicate that a field has a list of items available from which you can choose. When you click the button, it
presents the list in a scrollable box. Click on any item in the list to select it. There are two types of drop-down lists: self-building lists
and value lists.
A self-building drop-down list allows you to manually enter a new value which is automatically added to the list for future selection.
This type of drop-down list has only one column of data:
For instructions on how to alter drop-down list contents, please see Dropdown List Management.
Form Tab: Located at the top of each form, the form tab shows the form’s name (Gages in the above example).
Record Selector Bar: You can use the record selector bar, a tall rectangular bar located on the left side of the form, to select the
entire record for copying or deletion.
No record changes have been made; record is not selected for copying or deletion:
Since the program automatically presents records in Form View, you must manually switch to Datasheet View by clicking the
toolbar icon .
Form Tab: Located at the top of each form, the form tab shows the form’s name (Gages in the above example).
Record Selector Buttons: Record selector buttons are small rectangular buttons located on the far left side of each row. Use them
to select the entire record (row) for copying or deletion (the row will be highlighted in yellow when selected). You can also use them
to store any changes made to the record; if you change any fields, an icon of a pencil will appear on the button; click on the button
to write your changes to the database.
You can select multiple records by clicking and dragging your mouse pointer over the desired records. To select all records
between two records, first click on the first record, then hold the SHIFT key while you click on the last record. This operation
selects all records between the first and last records.
A selector button that has an asterisk (*) on it indicates that a row is a new record position (it will always be located at the bottom
of the table):
All Records Selection Button: This small square button is located on the upper left portion of the table, just below the control menu
icon. Click it to select all records in the table.
Column Header
Each column header contains the name of the field that it represents (Gage ID and Description in the example below). When you
click on a column header, you select the entire column, i.e., the Description column shown here:
You can then work with it as a whole. For example, click the column header to select a column that you want to move or hide. You
cannot move the contents of one column to another column.
Filters
Filters allow you to select a subset of records that match the criteria you enter. This may not seem useful at first, but you will
appreciate this feature later when you have hundreds or thousands of records from which to select. GAGEtrak’s Quick Filter and
Advanced Filter commands may be used to find a subset (dynaset) of records that match the criteria you enter.
Quick Filter
Use the Quick Filter command when you need to quickly find records based on a simple search. Quick Filter is accessible from
Tools toolbar.
Likewise, if you enter *Caliper, it tells the program that you want all gage records with descriptions ending in the word Caliper,
such as 4-inch Caliper. Furthermore, if you enter *Caliper*, it tells the program that you want all gage records with descriptions
containing the word Caliper, such as 4-inch Caliper and Caliper Digital.
You can specify as many filter fields as you need, depending on how selective you want to be. After you enter any filter values,
click the Find button to view the filtered record set. To remove any filter information, click the Clear Filter button.
You can add unlimited criteria by selecting the appropriate join condition of And or Or. You can edit directly in the criteria field,
provided you know the right syntax.
To access a saved search, click the Advanced Filter icon and click Open Search. A list of your saved searches will be displayed.
Click the name of the search you want to open and click Select. Your filtered records will be displayed.
Tip: Because GAGEtrak allows a literal search on these characters, to find Machine #1, for instance, you would enter Machine [#]1.
Field Filter
While you’re in Form View or Datasheet View, you can place your cursor in the field by which you want to filter records and then
click the Field Filter icon to search through your records for specific information.
For example, you could search the database for gages located in a certain department or for gages you purchased last year. You
can search for any text string, including a phrase, a word or part of a word, dates within certain time periods and much more.
The Field Filter allows you to filter your records by any field in the software, whereas the Quick Filter provides a limited number of
pre-defined fields. The Field Filter also allows for more detailed searches similar to the Advanced Filter, but is less complex.
To find data:
1. Display the table or form for the records you want to search.
2. Place your cursor in the field (or column) in which you want to search.
For a more detailed filter, deselect all values and then click Text Filters; the following options appear:
You can, for example, search for all gage records that have a Description that contains the word Micrometer. In this
instance, you would click Contains; the following window opens. Enter the value you want to find and click OK.
Removing Filters
After using the Quick, Advanced or Field Filters, click the Show All Records icon to undo the filter and view all of your records.
Enter the information into the record and then repeat any of the above steps to add another new record.
Each of the above options takes you to the bottom of the datasheet and activates the last row, which is always present for the
addition of a new record. This blank row is marked with an asterisk:
Enter the information into the record; repeat these steps to add another new record.
Deleting Records
In Form View, go to the record you want to delete and click the Delete icon . GAGEtrak will ask you to confirm the deletion.
In Datasheet View, you can delete multiple records at once. Use the record selector buttons to select all the records that you want
to delete and then click the Delete icon . GAGEtrak will ask you to confirm the deletion of each record.
If you change more than one field on a record and want to remove all unsaved changes, click the Undo icon in the toolbar. This
will undo all changes made to the entire record.
Saving Records
GAGEtrak automatically saves records whenever you go to a different record or close the window, but you can manually save
records by clicking the record selector bar (or selector button in Datasheet View). You can also click the Save icon in the
Output toolbar to save your records.
Note: Where indicated by CTRL, press the CTRL key while pressing the other key.
To enter a new gage record, click the New Record icon in the toolbar or the New Record button toward the bottom of the
screen in the record navigation bar.
Use your mouse cursor (or tab key) to move between the available fields in the gage record window.
Field/Button Description
Gage ID In this field, enter a unique alphanumeric identification code for each gage. In order to save the gage record, you must
enter an ID. For consistency and efficiency, you’ll need to develop your own gage ID numbering system.
Tip: Avoid using the characters #, *, ! and ? in your gage IDs or other fields, as these are considered wildcard characters
in GAGEtrak. It is also recommended that you do not use “ or ‘, for gage IDs. If you must use these characters, such as
in “Gage #1”, then you must place brackets around the wildcard character whenever you want to search or filter your
records; for example, you would enter Gage [#]1.
For more information about wildcards, please see Program Conventions.
Status Use the list box to pick from your available choices (for example, 1–Active). This field is required. To add more choices
to the Status field, go to the Setup menu and select Status ID Entry (see the System Administrator’s Guide for more
information).
Ref. Standard Check this box to indicate that the record is for a calibration reference standard (such as a gage block or reference
weight), not a gage.
NIST No. For reference standards only, enter the number that NIST (National Institute of Standards and Technology) provides for
traceability purposes. If it’s not marked on the reference standard, ask your supplier for the number.
Gage S/N Enter the actual gage manufacturer’s serial number (found on most gages).
Asset No. In this field, enter the gage’s asset number (usually issued by your accounting department).
Model No. Use this field to store the model number of this gage.
Type This field is a list box field from which you can choose or enter a classification of the type of gage (such as Variable,
Attribute, Dial, Vernier, Hard, Digital, or SPC).
Unit of Meas. Enter the actual units that the gage measures in (such as In, mm, N, LBf, LBm, Ohms, or mA). This field is a list box in
which more choices will be available as you add them for other gage records.
Drawing No. and If applicable, enter the gage drawing number and date of the original drawing (usually for custom-designed gages,
Drawing Date fixtures, or templates). Otherwise, use this field to store other information.
Change Level Enter the current change level ID of the current gage drawing and the date of the most recent drawing change level.
and Change Date
Notes Use this field to store any comments about the gage. If you check the Copy Gage Notes When Issuing checkbox in the
Settings -> General tab, these notes will be copied to the Notes field in each issue record for this gage.
Description Enter a brief, but informative, description of the gage.
Storage Location Enter the gage’s storage or usual location (for example, Tool Crib–Bin 12).
Current Location This field contains the gage’s current location (such as Assembly Dept.).
Service Date Enter the date on which you first started using the gage.
Retirement Date In this field, enter the expected or actual date on which you stop using the gage. Usually this date is at the end of the
gage’s useful service life (typically 5-10 years) or at the expected date of major overhaul or maintenance.
Supplier Code This field contains the supplier code or name of the gage supplier. If you plan to use GAGEtrak’s supplier records, enter
the supplier ID code in this field – not the supplier name. The drop-down list box for this field contains information that
you entered in Supplier Entry.
Cost Enter the actual purchase price or build cost of the gage.
Purchase Date In this field, enter the date on which you purchased or first used the gage.
User Defined This field stores any other data you need to track.
Manufacturer Select or enter the manufacturer of the gage (this field creates its own list as you enter different manufacturers, so you
can later just select from the list).
Owner This field also creates its own list as you enter different gage owners.
Issue/Return Button
When you need to issue a gage to a different location or department, you can record the issue in GAGEtrak. This feature is
particularly useful in a gage crib situation, where gages and inspection equipment are loaned out and then returned for storage
and safe keeping. By tracking this information, you’ll know which gages your company uses most often and which employees or
departments use them.
To issue or return a gage, click the Issue/Return button at the bottom of any of the tabs within Gages. The Issue Gages screen will
open.
Note: You can also issue and return gages by selecting Issue Gages or Return Gages from the Crib Management menu. However,
Issue Gages and Return Gages are designed for consecutive gage issues or returns (for large batches of gages) and to facilitate bar
coded data entry. Issue Tracking is designed for issuing or returning a single gage.
When you issue a gage, GAGEtrak inserts the current date and time as the Issue Date and Issue Time. It also changes the gage’s
Current Location field to a description that consists of Issued To plus Issued Dept., for example, Joe Jones/Assembly.
When the gage is returned, click the Issue/Return button. GAGEtrak assumes you want to return the gage if its current record is
incomplete; the form now allows for return information to be entered:
Received Date and Received Time are automatically populated with the current date and time, though these values can be
changed. After entering any other pertinent return information, click Return Gage. GAGEtrak changes the gage’s Current Location
field to its storage location.
You must use these issue tracking records for any gage whose calibration schedule is based on usage or cycles instead of elapsed
calendar days. These records track usage days and operating cycles; they also update the next due date and or estimated due
date of gages with these frequencies.
If you consistently use the Part No field, you’ll create manufacturing traceability. For example, if you find that a gage is out of
tolerance, you can immediately generate a part recall report that lists all parts that you might have measured incorrectly.
Field/Button Description
Issue Date and These fields track the date and time at which you issue the gage; the current date and time prefill the fields and can be
Issue Time edited.
Type Select the reason for issue; this field creates its own list from your entries.
Issued To Enter the name (or select it from the drop-down list) of the person to whom the gage is being issued. The names
available for selection in this field will be dependent upon the selection(s) made within the Gage Entry -> Auth. Persons
tab. For more information, see Restrict Issue under the Gage Entry -> Auth. Persons tab.
Issued Dept Select or enter the department that will use the gage.
Part No. Use this field to track the part or group of parts that the gage will measure.
PO No. You can enter a Purchase Order number if you’re sending the gage out to a supplier for repair or calibration or are
manufacturing parts for a customer.
Promised Date Enter the date on which you expect the gage to be returned.
Issue Gage After entering issuance information, click the Issue Gage button to issue the gage and save the record.
Button
Issue Label Note: A label printer must be installed to use this feature.
Button
Click on this button to print an issue label for the gage being issued. When you click Issue Label, the Select Label Type
window will appear. Select an appropriate label size for the gage being issued. When you click the View button, you will
be prompted to select a label printer; once you have done so, the Custom Report Editor will open to show you a preview
of the selected label. Close the Custom Report Editor to return to Select Label Type; click Print to print the issue label or
Close to close the window and return to Issue Label.
The printed label shows the predicted Next Due Date for the gage based on the frequency, unless the frequency was
set to Usage or Cycles, in which case the Est Due date will appear on the label.
Received Date These fields track the date and time at which the gage was returned. Click the small button next to Received Date to
and Received insert the current date and time.
Time
Received From In this field, enter the name of the person who returned the gage.
Cycles Enter the number of cycles performed by the gage (usually 1). GAGEtrak adds this number to any previous cycles for
the gage. It uses that number to calculate the Next Due Date for gages that calibrated according to cycles.
Use Left The value in the Use Left field is a decreasing value based on how many times you have left to use the gage before it is
due for calibration.
Notes Use this field for important comments, such as damages or malfunctions.
Return Gage After entering any pertinent return information, click the Return Gage button to complete and save the record.
Button
Double-click on this field to open a pop-up window that shows you the date, time, person, department and part information from
Issue Tracking.
Enter a new Gage ID directly into the New Gage ID field or select a gage numbering scheme from the drop-down list. If you select a
gage numbering scheme, GAGEtrak will automatically input the next subsequent ID for the New Gage ID based on the numbering
scheme in the Setup -> Settings -> Automatic Numbering tab. Click Clone. Click OK on the confirmation window. To create an
additional clone, click Clone again.
When you’re finished cloning, GAGEtrak will display the last cloned record that you created and you can enter each clone’s unique
information.
Remember, you can generate this chart only after you’ve entered some calibration and measurement records (see the next chapter
for more information on calibration records). As you can see in the image above, the chart plots before and after values and
nominal, minimum and maximum allowable limits. Click the Print button to print the graph.
Calibration Button
This button will take you directly to Calibrations (the calibration entry screen). When you go to Calibrations from Gages in this
manner, the records are filtered to show the historical calibration records for only the selected gage. If you choose to add a new
calibration record while in this filtered view, you must reselect the Gage ID from the drop-down list.
If Usage or Cycles is selected for Calib Freq the calibration schedule changes slightly, as shown below:
Note: If you have gage families that share the same test points for calibration, it is recommended that you review the section on
Test Point Groups found later in this guide as you can pre-define test points for the family and simply attach them to those gages to
save data entry time.
Field/Button Description
Gage ID The ID of the selected gage will appear in this field.
Resolution Use this field to store the resolution of the gage. This is the smallest (or least count) unit of motion that the gage is
capable of measuring and displaying. For example, 0.001 is the resolution on a typical dial caliper.
Uncertainty This field holds the uncertainty value; use it only if this record is for a reference standard. You can obtain this value from
the manufacturer. It’s expressed in units, such as percentage (0.5%), proportion (0.005) or measurement units (0.0001
inch).
Operating Range Enter the gage’s allowable operating range as to the minimum and maximum size it could measure.
Description The description of the selected gage will appear in this field.
+ Tolerance Use this field to store the upper tolerance for the gage, as published by the manufacturer. GAGEtrak later uses this
information to calculate the maximum value for calibration test points. To enter this value as a percentage of the
nominal, enter the value followed by the percentage sign (for example, enter 1%).
Tip: Check the placement of decimal points; for example, 1% equals one percent and .1% equals one-tenth of a percent.
- Tolerance Enter the lower tolerance for this gage, as published by the manufacturer (use a positive value). GAGEtrak later uses
this information to calculate the minimum value for calibration test points. To enter this value as a percentage of the
nominal, enter the value followed by the percentage sign (for example, enter 1%).
Tip: Check the placement of decimal points; for example, 1% equals one percent and .1% equals one-tenth of a
percent.
Test Point Group This field contains the group of standards that the Gage uses. It helps to update standards for a number of gages at
once as well as fill in standards for common gages. The standard also includes resolution, precision and plus/minus
tolerance values.
Test Point ID Enter a meaningful test point description, for example, Outside Diameter Check. Each Test Point ID that you enter for
the gage must be unique. If you need to use the same name for multiple test points, number or letter each name. For
example, if you’re using CMM Check in more than one Test Point ID, number the name for each standard. Your IDs
would look like this: 01. CMM Check, 02. CMM Check, 03. CMM Check. This numbering also lets you control the list’s
sort order (the program automatically keeps the list in alphabetical order by the Test Point ID value).
Type Two types are available: Variable or Attribute. Select Variable for those test points that have a value that you actually
measure (such as 0.502 inches). Select Attribute for pass/fail or visual types of checks. Selecting Attribute does not
calculate accuracy of particular test points.
Units Indicate the units being measured, such as inches, mm or degrees.
Minimum When you enter the nominal measurement, GAGEtrak automatically calculates the minimum measurement, based on
the gage’s –tolerance. This value is the minimum acceptable value for the gage when you measure this test point (for
example, 0.999).
Nominal Enter the nominal value for the gage when you measure this test point (for example, 1.000).
Maximum When you enter the nominal measurement, GAGEtrak automatically calculates the maximum measurement, based on
the gage’s +tolerance. This value is the maximum acceptable value for the gage when you measure this test point (such
as 1.001).
Ref Type Select the type of Reference Standard that will be used for this test point. This list box will show the Gage Type of every
reference standard in the database.
Attribute Gages
Attribute gages typically have a pass or fail result and do not require that you document a measured result. GAGEtrak supports
entries for attribute gages by simply changing the Type for each Test Point record from V to A. By doing so, the form will change to
a format allowing for Pass/Fail values to be selected later in Calibration Measurements.
Field/Button Description
Gage ID The ID of the selected gage will appear in this field.
Number of Test In this field, enter the number of standards.
Points
Start Value Enter the smallest nominal value for the similar test point.
Increment Value You can enter the difference between the sizes of the nominal values of the test points in this field, such as .5 or .005.
Test Point Enter the portion of the name that will be the same for all of them. For example, let’s say that you’ve entered 6 as your
Names Number of Test Points and 1 as the Start Value. Also, you’ve chosen an Increment Value of 1, with Inch as your Unit of
Measure. If you enter Gage Block in this field, the resulting names for your standards will be 1. Gage Block (1 Inch) and
2. Gage Block (2 Inch).
Tip: If your number of test points is between one and nine, your Test Point ID names will be numbered like this: 1.Name,
2.Name. If you have from ten to 99 standards, their names will look like this: 01.Name, 02.Name.
Type Select the type of test point: Variable or Attribute. Select Variable for those standards that have a value that you actually
measure (such as 0.502 inches). Select Attribute for pass/fail or visual types of checks.
Ref Type Select the type of Reference Standard that will be used for this test point. This list box will show the Gage Type of every
reference standard in the database.
Gage ID of Select from a list of available Test Point IDs. The list is limited by the Ref Type field. An empty Ref Type field would show
Standard all available IDs.
Units In this field, enter the unit of measure that the test points share.
Field/Button Description
Gage ID The ID of the selected gage will appear in this field.
Description The description of the selected gage will appear in this field.
Date This field shows the date for each calibration record.
By In this field, you’ll see the name of the user who performed the calibration.
Results Any additional results recorded about the calibration will appear in this field.
Field/Button Description
Gage ID The ID of the selected gage will appear in this field.
Description The description of the selected gage will appear in this field.
View/Print Button The procedure text and the attached OLE image will open up in a new window for viewing/printing.
Delete Button Click this button to remove the procedure from this gage. When you click this button, a dialog window will appear to tell
you that, in this screen you can only remove the procedure from the current gage record. To remove the procedure,
click Yes. If you want to delete or remove a procedure from all gages, you must do so in Procedures.
Attach The Attach Procedures button allows you to attach a procedure to every gage of a particular gage type. For safety
Procedures measures, GAGEtrak will display a confirmation message; click Yes to proceed.
Button
Field/Button Description
Procedure Name To link a calibration procedure to the current gage, select the procedure name from this list box.
Procedure In this section, you’ll see either the procedure text or any attached pictures.
Field/Button Description
Procedure Name To link a calibration procedure to the current gage, select the procedure name from this list box.
OLE The image associated with the procedure is displayed in this field.
Field/Button Description
Procedure Name To link a calibration procedure to the current gage, select the procedure name from this list box.
File This is the path of file attachment.
Note: When this procedure record was initially entered into Procedures, it should have been verified that all users of this
application have the ability to view the contents of this file; this includes both access to the directory where this file is
stored and having sufficient network security rights to open this file.
File Description Description of the type of file attached. For example, if the attached file is a Microsoft Word document the Description
field will contain Microsoft Word Document.
Adding Procedures
To link another calibration procedure to this gage, use the record navigation buttons at the bottom of the Procedures tab to add a
new procedure record. Again, select the name of the procedure from the drop-down list.
Field/Button Description
Gage ID The ID of the selected gage will appear in this field.
Description The description of the selected gage will appear in this field.
Part No. Select the part’s ID number; the remaining associated fields will auto-fill with information from the part record. This
information is read-only within this screen.
Field/Button Description
Gage ID The ID of the selected gage will appear in this field.
Description The description of the selected gage will appear in this field.
User Defined These fields can be used to store additional information; the label names and data types can be customized within the
Setup -> Settings -> Interface tab -> Gage Custom sub-tab.
File This is the path of the file attachment. Selection of files is made easier by selecting the drilldown button […] to the right
of the file field that brings up a Locate File To Attach dialog box for file selection.
Note: Verify that all users of this application have the ability to view the contents of attached files; this includes both
access to the directory where this file is stored and having sufficient network security rights to open this file.
File Description Description of attached file type. For example, if the attached file is a Microsoft Word document the Description field
will contain Microsoft Word Document.
Delete button Highlight the record indicator to the left of the File name and or place the cursor in the File name field and select Delete
from the Ribbon to remove the attachment from the gage record.
View/Print Button Select this button to open the selected file with that file type application.
The upper portion of this form can be used to record any authorized persons that are associated with a gage record.
Individual gages can have specific triggering events, for example, sending a Gage Issuing Email or running an external application if
a calibration has failed. An external application could be an AutoCAD drawing or a Microsoft Excel spreadsheet.
Field/Button Description
Gage ID The ID of the selected gage will appear in this field.
Description The description of the selected gage will appear in this field.
Restrict Issue The options in this drop-down list are Program Default, Restricted and Not Restricted and control the persons
authorized to issue gages.
If Program Default is selected, the application will check whether or not the Restrict Issue to Authorized Users
checkbox is checked within the Settings -> Security tab. If it is, the Issued To drop-down list in Issue Gages will list
only the authorized users entered into the Gages -> Auth. Persons and Events tab -> Authorized Persons pane. If the
Restrict Issue to Authorized Users checkbox is not checked, all staff will be listed in the Issue To drop-down list in the
Issue Gages form.
If Restricted is selected, it will override the program default and the Issued To drop-down list in Issue Gages will be
restricted to the authorized persons for that specific gage. You will not be able to select this option until Authorized
Persons have been added to the list.
If Not Restricted is selected, it will override the program default and the Issued To drop-down list in Issue Gages will be
populated with the staff list.
If you create a schedule here, it will only be available for this particular gage. To create a universal additional schedule that can be
used for multiple gages, go to Calibration Utilities -> Additional Schedules.
Define the schedule information in the upper portion of the form (or if you have defined schedules from within Calibration Utilities
-> Additional Schedules, you can select an existing schedule from the Schedule Name drop-down list and the associated
information will auto-fill; any changes you then make to the schedule will be specific to this gage).
To create another schedule for the same gage, click the New Record icon in the upper record navigation bar.
After selecting the Gage Type and Schedule Name, click Attach. GAGEtrak will prompt you to confirm your action.
Field/Button Description
Part No. In this field, enter the number of the part (use either the customer’s number or your internal part number).
Description Enter either the name of the part or a description that includes the name.
Operation Use this field to track the production operation or work center description that uses or installs the part
(such as Stamping or Machine 13).
Part User 1 and Part User 2 Use these fields to track additional information on the part.
Drawing No. Use these fields to record the blueprint drawing number and drawing date.
and Drawing Date
Change Level In these fields, enter the blueprint change level (also called engineering change level) and the change date.
and Change Date
Inspection Procedure Enter instructions for checking the part.
Field/Button Description
Gage ID Select the Gage ID of the gage you will use to inspect the part.
Description GAGEtrak will automatically enter the description of the gage you selected in the Gage ID field.
Method Enter the control method, such as Inspection Sheet or Control Chart.
Dimension In this field, enter the dimension or characteristic that you will check with the gage.
Comments Record any notes about the dimension or characteristic that you’re checking.
Freq. Specify frequency in which the part will be inspected with this gage (such as 5 per Shift or 10 per Day).
Field/Button Description
Procedure Name Enter a unique title for each procedure. If you try to create two procedures with the same name, GAGEtrak prompts you
that you can’t have duplicate index values. If this happens, click Undo and enter a unique procedure name.
Procedure In this field, enter the text of the procedure. For text formatting options, click the Open Editor button.
Remove Button If you want to keep the procedure in your database but remove it from your gages, click Remove. This action removes
the procedure from all attached gages, but keeps it in Procedure Entry for your reference. If you want to remove a
procedure only from a particular gage, do so within Main Records -> Gages.
Open Editor Opens an external text editor program for editing/formatting procedure text.
Button
Clone Procedure Opens the Clone Procedure dialog to allow for making a clone of the current procedure.
Button
Cloning Procedures
Click Clone Procedure to open this window in which a copy of the existing procedure can be made.
Enter a New Procedure Name and click Clone. A confirmation message will appear giving you an opportunity to change any gages
that referenced the original source procedure to reference the new procedure. Note: This change cannot be reversed, so be sure
this is desired before clicking the Yes button.
Field/Button Description
Source Procedure Name This read-only field displays the name of the procedure that will be cloned.
New Procedure Name Enter the name for the new procedure.
Clone button Click this button to create a clone of the source procedure.
Close button Clicking this will close the dialog without making a clone.
1. Open the program that contains the procedure you want to copy.
2. Highlight the text, and then press Ctrl-C to copy it to Windows Clipboard.
3. In the Procedures -> Procedure Text tab, enter a Procedure Name.
4. Place your cursor in the Procedure textbox.
5. Press Ctrl-V to paste the procedure.
Select the type of object you want associated with the procedure and then click OK. When you select an object type, the program
in which you created the object opens so that you can edit the image (if necessary). When you’re finished, just click inside the OLE
object box which links the object to the associated procedure and returns you to the Procedure Image tab.
You can also paste an image into this field from your clipboard.
Field/Button Description
File The File field can accept manual input of a file path or you can click the drilldown button […] to the right of the File
field to browse to and select a file.
Note: Verify that all users have the ability to view the contents of this file. This includes both access to the directory
where this file is stored and having sufficient network security rights to open this file.
File Description When a file path is manually typed, you have the opportunity to enter a File Description. If the file was automatically
inserted with the aid of the drilldown button […], the format of the selected file attachment will be displayed in the
File Description field; for example, a file created with Microsoft Word will have a File Description of Microsoft Word
Document.
View Button Click this button to activate the registered application associated to the file extension, for example Microsoft Word.
Select Service Requests from the Main Records menu and the main entry screen will appear:
Field/Button Description
CA/Request No. Upon selection of a Letter Type, this field automatically generates a number to track your requests. Define automatic
numbering in Setup using your own format.
Request Date Enter the date or click the small button on the right of this field to automatically enter today’s date.
Requester Select or enter the name of person requesting service.
Insurance Amt This field displays the sum of all insurance amounts from the gages listed below it. (auto-filled by the Cost field in
(upper portion of Gages). The field on this form is not editable, but original amounts can be modified in the lower portion of the screen
screen) for insurance purposes.
Letter Type Select the type of the document to use (such as Calibration, Repair, Calibration & Repair or Corrective Action Notice).
If the application is set to change the status of a gage when that gage is added to a Service Request, Type is used to
determine the new status of that gage. Refer to the Setup -> Setup CA / Service Request section for more information.
Service Supplier Select the supplier code of the service provider (this might also be a department within your own company).
Status This field lets you close the service request whether the status of the individual gages listed below is Open or Closed.
Closing a service request will also close any open gages attached to that service request.
Completion Date After service on all gages listed has been completed, use this field to set the completion date for the entire service
request. Enter the date or click the small button on the right of this field to automatically enter today’s date.
Field/Button Description
Supplier Code Enter a unique supplier ID or code for each supplier.
Supplier Name Enter the company name of the supplier.
Supplier Type Use this field to categorize your suppliers by the type(s) of goods sold.
Contact Person Enter the name of the contact person for this supplier company.
Salutation Enter a salutation for the company contact to be used for written correspondence (such as Mr., Ms., or Mrs.). Leave this
field blank if you don’t want to use a salutation (i.e., Joe Smith vs. Mr. Joe Smith).
Method A3 lets you specify a reliability target and requires a low risk of making unnecessary changes, before recommending that a
change in calibration frequency is necessary. Reliability is defined as the probability that a gage will still be “in” tolerance at the end
of the calibration interval. GAGEtrak estimates the current reliability by combining the calibration histories of all gages with the same
gage type and same calibration frequency. Then, based on the reliability target, GAGEtrak calculates the probability that a change
is not needed (called significance). If significance is below the significance threshold then GAGEtrak suggests a recommended
change. When a change is found to be necessary, method A3 uses formulas that optimize the calibration frequency in fewer steps
than Method A1.
In Gages, on the Schedule tab, you may specify a Minimum Frequency, a Maximum Frequency or both. Method A3 or A1 will
notify you in the event that a recommended change is being overridden by these specifications.
Field/Button Description
This is the desired end-of-period reliability, i.e., the desired probability that the as-found condition of the gage will
be “in tolerance” at the end of the calibration period (after the optimum calibration frequency has been achieved).
Reliability Target
GAGEtrak will recommend changes to the calibration frequency until the specified reliability is obtained. The default
Reliability Target is 80%. Specifying higher reliability will result in more frequent calibration. You can’t change this
here. To change this, go to Setup -> Settings -> Cal. Options -> A3 Adjusting Calibration Frequency Setting.
Number Format Choose the number of decimal places you want to be displayed.
Significance This is the maximum amount of risk GAGEtrak will take in recommending a change, i.e., the risk that a
Threshold recommended change will turn out not to have been necessary. The default is 0.3. Specifying lower significance
will increase the number of calibrations required to make a decision. You can’t change this here. To change this, go
to Setup -> Settings -> Cal. Options -> A3 Adjusting Calibration Frequency Setting. Significance must be between 0
(never change) and 1 (always change).
Type Gage Types listed here have one or more gages specified in Gage Entry to use method A3. If a Gage Type has more
than one Calibration Frequency in use, it may appear more than once.
Method A3 Formulas
a = significance at I0
g = number in tolerance at I0
n = number calibrated at I0
I0 = existing interval
I1 = new interval
R = reliability target
R0 = g/n
g
n!
α = 2∑ R k (1 − R ) n − k
If R0 < R , k =0 k ! ( n − k )
!
n
n!
α = 2∑ R k (1 − R ) n − k
If R0 ³ R, k=g k!(n − k )!
I1 = (1 + 1/R)I0 for R0 = 1
I1 = (1 + R/2)I0 for R0 = 0
Interpolation formulas (Used when a change(s) has already been made, that has proved to be excessively large):
I2 = (I0 + I1)/2
Additional Schedules
GAGEtrak allows you to schedule additional due dates for your gage records such as a maintenance date or the date on which you
would like to send the gage to a calibration provider. Each additional schedule is user-defined, so it can be used for virtually any
scheduling need.
If you create a schedule here, it will be available for any gage (as opposed to creating a schedule in the Gages -> Additional
Schedules tab). After creating a schedule, you can go to the Gages -> Additional Schedules tab and associate the schedule to the
gage. After doing so, that gage’s information will appear in the lower portion of this screen.
If you make any changes to the information here and want those changes to be applied to every gage that uses the schedule, click
the Update button.
All criteria related to developing test points are the same as what is documented in the Calibrations -> Measurements tab.
Each formula consists of simple mathematical expressions using the given variables enclosed in square brackets, arithmetic
operators, etc. After entering a formula, click the Test button and you’ll be prompted to enter a value for the variable (in this
example, enter a value for Celsius to calculate Fahrenheit:
Issue Gages
Field/Button Description
Gage ID Select the Gage ID of a gage available for issuance. A non-selectable button labeled Past Due! appears to the right of
the Gage ID field if you have selected a gage with a calibration schedule already past due.
Next Due Date Issue Gages will generate the Next Due Date when you issue out a gage with a frequency UOM other than Usage and
or Cycles, unless Usage and or Cycles is due for calibration, then a Next Due Date will be generated. If the gage is due
for calibration, a message stating so will appear when the past due gage is selected.
Issue Date These fields track the gage issuance date and time; the fields are prefilled with the current date and time, but are
and Issue Time editable.
Type Choose the type of issuance; this field creates a self-building list as you enter different descriptions.
Issued To Enter or select the person to whom you issue the gage; however, the name selection for this field may be dependent on
the Gages -> Auth. Persons and Events -> Restrict Issue selection. For more information, see Restrict Issue.
Issued Dept. Select or enter the department or job number that will use the gage.
Part No. Use this field to track the part or group of parts that the gage will measure.
PO No. You can enter a Purchase Order number if you’re sending the gage out to a supplier for repair or calibration or are
manufacturing parts for a customer.
Promised Date Enter the date on which you expect the gage to be returned to you.
Storage Location This field shows where the gage is stored when not in use. You cannot edit this field.
Current Location Show the current location of the gage. You cannot edit this field.
Clear Form This button clears all fields in the form.
Issue Gage Click this button to issue the gage; the form will then be cleared allowing for the issuance of the next gage. GAGEtrak
changes the gage’s Current Location field to a description that consists of Issued To plus Issued Dept., for example,
675/Job 7512 Final Assy.
Issue Label Print a select a label type for the gage being issued. (A label printer must be installed to accommodate this request.)
The printed label shows the predicted Next Due date for a gage based on the frequency set for the gage, unless the
frequency was set to Usage or Cycles and the gage is not ready for calibration, then the Est Due date will appear on the
label.
The Return Gages form displays the issuance information at the top of the form; the return information fields are:
Field/Button Description
Gage ID Select the gage ID to return. The list is limited to issued gages only.
Received Date These fields show the date and time at which you received the gage; they’re prefilled with the current date and time.
& Received Time
Received From In this field, enter or select the name of the person that returned the gage.
Cycles Enter the number of cycles used or parts measured by the gage. GAGEtrak adds this value to any previous cycles for
the gage and then uses that value to calculate the Next Due Date for gages that you calibrate according to cycles.
Notes Document any important comments, such as damages or malfunctions.
Clear Form This button clears all fields in the form.
Button
Return Gage Click this button to complete the record; a new blank form appears to return another gage. After you save the record,
Button GAGEtrak changes the gage’s Current Location field to its Storage Location.
Gage Kitting
A kit is a collection of gages or accessories used to measure a specific part. Gages or accessories comprising a kit may be issued
individually, but a kit can only be issued if gages or accessories are complete. To assist you in tracking all of your gages and
measurements for every specific part, GAGEtrak provides a Kitting feature. With this valuable feature, you can create a kit, assign
gages to the kit and even track the issuance and return of kits. Also, GAGEtrak allows you to automatically identify gages that can
be used to measure a specific part. You can create a kit manually by entering all of the gages and other information required into
the Kitting window. You can also create a kit by cloning an existing kit and editing the information to make it unique. Navigate to
Crib Management -> Gage Kitting.
Field/Button Description
Kit ID Enter a unique identifier for the Kit.
Kit Description Enter a detailed description of the contents of the kit.
Storage Location The location in which the kit is typically stored when not in use.
Current Location When the kit is issued, this field displays the Issued To / Issued Department information and the Issued button will be
inactive.
Available for If all Required Gage Types and Required Gages are available allowing the kit to be issued, GAGEtrak automatically
Issue checks this checkbox.
Procedure Identify the procedure that describes how to use the gages in the kit with the parts they are measuring.
Field/Button Description
Issue Date and These fields are prefilled with the current date and time, but are editable fields.
Issue Time
Type This is the type of issuance, i.e., the reason for which the kit is being issued. This is a self-building list.
Issued To Enter the name (or select the name from the drop-down list) of the person to whom the kit is being issued.
Issued Depart Enter the department to which the kit is being issued (or select the department from the drop-down list).
Promised Date Enter the date on which you expect the kit to be returned.
Returning a Kit
A kit must have been issued before you can check it in. Click the Return button on the Gage Kitting -> Information tab. If a kit is
currently issued, clicking the Return button shows it as an open issue record allowing for the received date, time, etc. to be entered.
After completing the return record, GAGEtrak changes the kit’s Current Location to its Storage Location.
Field/Button Description
Received Date and These fields are prefilled with the current date and time, but are editable fields.
Received Time
Received From Enter or select a name from the drop-down list box of the person returning the kit.
Cycles For any gage in the kit that has a Cycles calibration frequency, enter the number of cycles that the gage used in the
kit’s return record. Usage Used, Usage Left and Estimated or Actual Due Date for each gage will be calculated and
reflected under the schedule in Gages.
Notes Document any important comments, such as damages or malfunctions.
Enter the following information about the gages and parts to be measured.
Field/Button Description
Gage Type Select the types of gages that are used in the kit. These fields can contain an unlimited number of gages types, units of
measure and size.
Quantity Total per Gage Type.
Parts Measured Select the parts that will be measured with each gage type. Using this feature helps you keep track of gages and parts
with Gage Type by automatically linking parts to gages when a kit is checked-out. The information in these fields is optional, and you
only need to use this feature if your company is required to keep track of all parts that are measured by your gages.
Note that when your curser is in a Gage Type field, the Parts Measured with Gage Type pane is specific to the active
Gage Type.
Part No / Part identification.
Description
Scenarios
Gage ID Gage Type
A001 Type A
A002 Type A
A003 Type A
• If you want to issue Gage ID A001, select the Required Gages tab and select Gage ID A001. When this kit is issued
you will be issuing Gage ID A001.
• If you want to issue Gage ID A001, A002 or A003, select the Required Gage Types tab and select Gage Type: Type A.
When this kit is issued, you will be issuing Gage ID A001, A002 or A003.
• If you want to issue more than one gage of a gage type, select the Required Gage Types tab and select Gage Type:
Type A and enter a quantity of two (2). When issuing this kit, you will be issuing any combination of two of the follow-
ing gages: A001, A002 and A003; for example, A001 and A002 or A001 and A003, etc.
Example: Create a kit and select a gage type of Caliper. If you were then to pick gage Caliper-001, then the issue of the kit would
include two gages, Caliper-001 (to satisfy the Required Gage list) and a second caliper (to satisfy the Required Gage Type List).
Since it is unlikely that this is the way a kit would be issued, gages that match the type listed in Required Gage Types are hidden in
the Required Gage list. This makes it so the user cannot accidentally select that a kit will include two gages.
Note: If you really do want to issue Caliper-001 plus a gage of type Caliper, select the Gage ID first and then select the Gage Type.
To create a new calibration record, click one of the new record buttons and then select the desired gage record from the Gage ID
drop-down. After you save the record by entering information into this screen (such as your department), GAGEtrak automatically
retrieves any standards you set up for the gage.
Field/Button Description
Gage ID Use the drop-down list to select from a list of available Gage IDs.
Tip: Once you’ve selected a gage to calibrate, do not change this field. After you save the calibration record, you can’t
edit this field. If you want to enter another calibration record for this gage or for another gage, click the New Record
button first.
Status The indicated status of the gage at the time of calibration will reflect as 1-Active, 2-In-Active, 3-Out for Repair, 4-In
Calibration, 5-Lost.
Note: The calibration Status field will disappear and cannot be edited once the calibration record has been passed.
Description GAGEtrak looks up the gage’s description from its Gage record and displays it here (you can’t edit it in this screen).
Gage S/N This field displays the gage’s serial number; you can’t change it here.
Calib Freq After you mark the gage as having passed calibration, GAGEtrak displays the calibration frequency that you entered in
Gages. If you need to edit this value, do so in Gages.
Calibration frequencies are stored with the calibration record. This allows you to maintain a complete history of
calibration frequencies and how they might change over time.
Note: If you made a selection from the Gage Frequency Adjusting Interval section for this gage, whenever you enter a
new calibration record, GAGEtrak will automatically adjust the Calibration Frequency, according to the rules you defined
in the Adjusting Calibration Frequency Settings table. Please see the Administrator Guide for details.
Next Due This field stores the next due date for calibration, based on the calibration frequency. You must check the Pass
checkbox in order for GAGEtrak to show the next due date.
Note: If a gage has a calibration frequency of Usage or Cycles and the gage is not past due for calibration, you will not
be presented with a Next Due date – this field will remain blank until the gage needs to be calibrated.
Calibration Date Use this field to store the date of the calibration; it’s automatically set to the current date. You can change it until the
calibration record is saved.
Time Like the Date field, this field automatically displays the current time. If you change the time, enter it in this format:
HH:MM. This field is required.
Department In this field, select or enter the name of the department that used the gage before calibration.
By Select or enter the name of the person who calibrated the gage. This field automatically displays the name of the
current user, but you can change it.
Calibration Type In this field, enter the type of work being performed, such as calibration, repair or rebuild.
Results Enter any results or comments (typically used for attribute-type gaging or dimensional layouts). Enter calibration
measurements into the Measurements table (see below).
Action Required Enter any action that may be required, such as Send out for Repair.
As Found Choose the condition of the gage before calibration or adjustment. Select In for in-tolerance, Out for out-of-tolerance
Condition or New for a new instrument that has not yet been calibrated. Prior to calibration, all test points of the instrument must
be within tolerance to have the As Found Condition field set to In. You need this information only if you’ve chosen Auto
Adjust Calibration Frequency for this gage (see the Administrator Guide for details).
Calibration Status Select the final calibration status: Passed, Failed, Repaired or Limited.
Interval This is a non-editable field based on the Gage Frequency Adjusting Interval selection made for this record in the Gages
Adjustment -> Schedule tab.
Method
Pass You must check this box in order for the program to automatically calculate the next calibration due date (Calibration
Frequency + Calibration Date).
Note: The calibration Status field will disappear and cannot be edited once the calibration record has been passed.
Findings Use this memo field to describe any other pertinent information, such as visual inspection notes. You can scroll through
this field if you need more room for text.
Note: Your certificates of calibration will include this field.
100 User Guide Chapter Ten: Calibration Records GAGEtrak 7 User Guide
Est Costs Projected calibration cost.
Cost To track your costs, enter any expenses related to this calibration (such as internal labor/material costs or outside
calibration service costs).
Hours There are two fields for hours. The gray Hours field will display the estimated hours that you entered for this gage in
Gage Entry. The white Hours field applies to this particular calibration. Enter the actual amount of time the calibration
required, or click the Start button to use the built-in calibration timer (see below).
Account No. Enter an account number or other tracking number associated with the cost (examples include a job, purchase order,
invoice or customer number).
Certificate No. Record the certificate number issued by the outside calibration provider or your company. You can use this field in one
of two ways: you can type in any alpha-numeric information you wish or you may use automatic numbering. If you want
to use automatic numbering, you must first set up your numbering in Setup -> Settings -> Automatic Numbering. You
can specify a numbering format and view the last number used.
Uncertainty This field is for the Uncertainty sum – input by user.
Coverage Factor k This multiplier is used to convert Combined Uncertainty to Expanded Uncertainty.
Deg of Freedom This is also called Effective Degrees of Freedom. If input on the Calibration form, this value will appear on the
Certificate of Calibration and on the Failure Notice reports.
Temperature, Enter the relevant environmental conditions for the calibration: Humidity, Temperature, Pressure or any other factor
Humidity, that may affect results. If you have an appropriate USB temperature and humidity sensor, you can double-click in the
Pressure and Temperature or Humidity controls to have the application read these values from the sensor.
Other
Select Label Design Choose the label design to print out the calibration record.
MSA Button To enter a study for the current gage, click the MSA button (MSA studies are explained in MSA Studies).
Graph Button To view an accuracy chart, click the Graph button.
Certificate Button If a calibration has been passed, select this button to view a summary or a detailed Certificate of Calibration report. If
the calibration record has not been passed, in essence the calibration has failed, you will be notified as such and will
be given the opportunity to print a Calibration Failure Notice report.
Gage Entry Button Use this button to switch to the Gage Entry record for the current gage.
View Label Button Generates the label based on the label design selected.
Print Label Button Sends the selected design for the label directly to the printer.
GAGEtrak 7 User Guide User Guide Chapter Ten: Calibration Records 101
Select Uncertainty Method / Budget
The Select Uncertainty Method / Budget form allows for the user to choose between using the Root Sum Uncertainty method,
choosing an existing Uncertainty Budget or to enter a value manually to determine how the Uncertainty in calculated for a
particular calibration. Simply click the […] button to the right of the Uncertainty field to bring up the Select Uncertainty Method /
Budget form and then follow the instructions within the form.
Field/Button Description
Calc Button To use the Root Sum of Squares method, click on the Calc button.
Clear Button If values need to be entered manually, click the Clear button. This will set the values in Uncertainty, Coverage factor k,
an d Degrees of Freedom controls to null and enable them, allowing user to enter values.
Select To the right of each Uncertainty Study listed is an unlabeled button allowing the user to choose that study for
Uncertainty calculating Uncertainty, Coverage Factor k and Degrees of Freedom. The values in the selected study will be used to
Study Button calculate each of the values. Note: An Uncertainty Budget must be created to utilize this function.
The Calibration Label Kit prints durable, laminated, cut-to-length calibration labels. It includes a printer that attaches to your PC’s
serial or USB port so it won’t interfere with your default printer (available in desktop and network versions). It also includes label
design software, fonts, clip art and bar codes – features that let you use it for many other quality control and production labeling
applications. For more information about the kit, please contact CyberMetrics Corporation or your distributor.
102 User Guide Chapter Ten: Calibration Records GAGEtrak 7 User Guide
Calibrations – Measurements Tab
GAGEtrak supports multiple reference standards on each Test Point, so that measurements that utilize a combination of master
standards can be accurately documented, and also supports multiple tolerances within a single calibration. This permits accurate
tolerance recordings for gages or instruments that support multiple plus and minus tolerances.
You can use this screen to compare the actual before and after measurements of the gage with the standards that you use to
calibrate the gage.
Field/Button Description
Test Point ID GAGEtrak copies the Test Point IDs from the gage record.
Type Two types of calibration standards available: Variable ‘V’ or Attribute ‘A’. Select Variable for those standards that have
a value that you actually measure (such as 0.502 inches). Select Attribute for pass/fail or visual types of checks.
Selecting Attribute does not calculate accuracy of particular standard. GAGEtrak copies it from the gage record, if
entered, or you can select it here.
Units The program also copies the units of measurement from the gage record.
Minimum, GAGEtrak copies the Minimum, Nominal and Maximum values from the gage record.
Nominal, and
Maximum
Format Specify the format for the numeric display.
Before Enter the actual measurement observed before you adjust the gage. The button to the right of this field brings up the
Calibration Formula Listing; for more information, see Calibration Formula Listing.
After Next, enter the actual measurement observed after you adjust the gage. The button to the right of this field brings up
the Calibration Formula Listing; for more information, see Calibration Formula Listing.
GAGEtrak 7 User Guide User Guide Chapter Ten: Calibration Records 103
Accuracy This field shows the accuracy value based on the before measurement (Before minus Nominal).
(Before)
Accuracy (After) In this field, you’ll see the accuracy value based on the after measurement (After minus Nominal).
Limited Use Based on the gage’s accuracy compared to its calibration standard, use this box to restrict the gage to limited use,
meaning that it shouldn’t be used for measurement of this particular range.
Reference This field stores the Gage ID of the reference standard, which is important for traceability back to a specific standard.
Standard You can manually enter the standard’s gage ID or select from a list of available standards (shown below) by clicking
the Edit Reference Standards button.
The list only lists gages that have an X in the Ref. Standard checkbox within the Gages -> Information tab.
A gage cannot be selected if a Reference Standard is past due for calibration. Gage ID of Standard is limited to
Reference Standards with no Due Date or Next Date Due in the future.
Next Due Date The reference standard’s next due date.
Uncertainty If you select the reference standard from the list, the uncertainty value will automatically display.
If you manually enter the standard, then enter its uncertainty value here. You can obtain this value from the
manufacturer; it’s expressed in units, such as percentage (0.5%), proportion (0.005), or measurement (0.0001 inch).
You must enter units of the same value; otherwise, the calculated Uncertainty will be wrong.
NIST No The reference standard’s NIST number.
104 User Guide Chapter Ten: Calibration Records GAGEtrak 7 User Guide
Calibration Formula Listing
Use the Formula buttons next to the Before and After fields to help calculate a Before or After value if there is not a calibration
reading for the selected standard. The Calibration Formula Listing works like a calculator based on predefined or user defined
formulas, originally set in Calibration Utilities -> Formulas.
Select a predefined formula from the drop-down list. You will notice that the value present in the field is retained from the last
input for the selected formula calculation. Either retain the value or input a new value and click OK; the formula computes. You
will be reverted back to the Measurements form and the newly calculated value will have populated the field, which in turn helps
in computing the accuracy values. This value is editable. If the Add New button is clicked, the Formulas entry screen will open for
your use. Refer to Calibration Utilities -> Formulas for more information.
Field/Button Description
Gage ID The ID of the selected gage will appear in this field.
Description The description of the selected gage will appear in this field.
View/Print Button This button opens the procedure listing in Report Viewer; the report can be printed or exported.
GAGEtrak 7 User Guide User Guide Chapter Ten: Calibration Records 105
Calibrations – Signature and Scans Tab
If your system administrator has enabled security, calibrations can be electronically signed or unsigned. If you are using the FDA
Edition of GAGEtrak, security is permanently enabled. Signatures are drawn from the User ID listing in the Setup -> Security ->
Users tab.
To sign a record, click the Sign button in the Calibrated By pane and then enter your User ID and Password; GAGEtrak will save
the signature and stamp it with the current date and time. The Approved By pane is signed in the same manner.
After signing is complete, the Sign button is replaced with an Unsign button. Click the Unsign button and enter your login
credentials; GAGEtrak will show that the record has been unsigned and stamp the record with the current date and time.
All signatures are recorded with the name of the signer, the date and time of the signature and the signature mode (whether the
calibration was signed or unsigned).
1. Navigate to the Setup -> Settings -> Security tab and check the Enable Security checkbox; then select Application
Logon from the Logon Method drop-down list.
2. Click the Electronic Signature Login checkbox to require each user to login with a User ID and password whenever the
Sign or Unsign buttons are clicked. This feature helps prevent unauthorized signatures; if it is not activated, GAGEtrak
will automatically record the currently logged-in user as the signer when the Sign or Unsign button is clicked.
106 User Guide Chapter Ten: Calibration Records GAGEtrak 7 User Guide
Calibration Scans
GAGEtrak provides the option of scanning in certificates from TWAIN-compliant scanners to store with the calibration records.
If a calibration has been signed, the calibration scan feature will be disabled and the user will not be allowed to delete, edit or
create new scans. The files of the scanned pages still exist if a scanned record is deleted and you will need to delete this file
yourself using the File Manager supplied with your operating system. The user will, however, be able to view/print scans.
To begin scanning documents, click the Scan New button at the bottom of the Calibrations -> Signature and Scans tab. The
following form will open:
Your TWAIN device needs to be set before you can use the scan feature. Click the Select Scanner Device button; the Select
Source dialog will appear. Select the scanner from the list and then click the Select button; you will be returned to the Scan
Certificate window.
Now, set the pixel type (refer to your scanner literature for more information regarding pixel types), scanner interface and file
extension preferences and then click Scan. If the scanning is successful, the scanned image will be displayed, prompting you to
save the image and include a description if necessary. Verify that all users of this application have the ability to view the contents of
the file. This includes both access to the directory where this file is stored and having sufficient network security rights to open the
file.
When you close this form, the Calibration Scans pane of the Signature and Scans tab will display the new record including the
Scan Date, Description and File Path.
If you click the […] button, the application will look for the image and open it with the application that is registered for that file type
in the workstation’s registry. If GAGEtrak cannot find the application registered for the certificate’s file type, you will be prompted to
choose a different application; select an image-viewing or image-editing application; it will launch and open your image file.
GAGEtrak 7 User Guide User Guide Chapter Ten: Calibration Records 107
Calibrations – User Defined and Attachments Tab
The User 1 – User 20 fields can be used to store additional information; the field types and names can be customized in the Setup
-> Settings -> Interface -> Gage Custom sub-tab.
The lower portion of this window allows you to attach files (in various formats) to the calibration record. Click the […] button to
locate and select the desired file; the File (path) and File Description fields will be populated. The application will use the registered
application for that extension to determine what application will open the attached file.
Note: Verify that all users of this application have the ability to view the contents of this file. This includes both access to the
directory where this file is stored and having sufficient network security rights to open this file.
To view or print an attachment, select it (by clicking the box to the left of the file path) and click the View/Print button; to delete an
attachment, select it and click the Delete button.
108 User Guide Chapter Ten: Calibration Records GAGEtrak 7 User Guide
User Guide Chapter Eleven:
MSA Suite
Overview
With MSA, you can assess your measurement systems using the statistical test procedures of repeatability, reproducibility, bias,
stability and linearity (collectively referred to as “MSA” studies). This feature saves time and prevents the mistakes that you can
make when you manually assess your measurement systems. You’ll soon find that it’s an essential tool for analyzing and managing
your MSA studies.
This feature was designed for calibration technicians, metrologists, inspectors and other quality control professionals who need a
convenient, easy-to-use method for documenting, tracking, and performing measurement systems analysis. The software is based
primarily on the techniques described in the AIAG MSA guide and other industry publications.
Before starting SPC, capability studies or any type of repetitive measuring, use MSA to make sure that your measurement system can
give you reliable measurements. Instructions for performing studies on your measurement system are given throughout this chapter.
The software is simply a tool used to store data, calculate results and generate printed reports and charts. It does not determine
whether a measurement system is good or bad. As the user, this determination is your sole responsibility.
Important: The technical support available for this software is limited strictly to the operation of the software. We cannot
provide advice or support on interpreting results or charts. If you have interpretation questions, please consult your customer, a
statistician, or other qualified professional.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 109
Terms and Definitions
Before using the GRR Module, you may want to familiarize yourself with these terms.
Bias
The difference between the observed average of measurements and the reference value is known as bias (sometimes called
accuracy; however, accuracy is a qualitative term that should be avoided when referring to bias). The reference value (accepted
reference value or master value) functions as an agreed-upon reference for the measured values. You can determine a
reference value by using a higher level of measuring equipment (such as metrology lab or layout equipment) to average several
measurements.
Linearity
Linearity is the difference in the bias (accuracy) values through the gage’s estimated operating range.
110 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Precision and Accuracy
Below, we’ll use a bull’s-eye target to describe the difference between precision and accuracy.
Accurate but not precise. Notice the readings are fairly well centered on the
target, but there is wide scatter
Precise but not accurate. You can see that the readings are all close to each
other, but are not centered on the target.
Precise and accurate. In this, the best condition, the readings are all close to
each other and centered on the target.
Precise and accurate are general qualitative terms that are not actually used in MSA studies.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 111
Appraiser × Part Interaction
When reproducibility error varies from part to part, that is called Appraiser × Part Interaction.
Stability
When using a measurement system to evaluate the same characteristic on a master or part over an extended period of time, the
maximum change in bias is known as stability uncertainty (or drift).
Consistency
When using a measurement system to evaluate the same characteristic on a master or part over an extended period of time, the
maximum change in repeatability is known as consistency uncertainty (or drift).
Variation Components
Equipment Variation (EV): Equipment Variation is an alternate term for repeatability, used primarily when we want to refer to
repeatability by initials, (EV).
Appraiser Variation (AV): Appraiser Variation is an alternate term for reproducibility, used primarily when we want to refer to
reproducibility by initials (AV). Although appraiser usually refers to an operator or technician, it can also mean different instruments,
or different plant locations, etc., or all of the above.
Interaction (INT): Interaction is short for Appraiser × Part Interaction, used when we want to refer to it by initials. (INT)
Gage Repeatability and Reproducibility (GRR): Gage Repeatability and Reproducibility is the RSS (root-sum-square) sum of the
equipment variation, appraiser variation and interaction; it is usually referred to as GRR, GR&R or Gage R&R.
Part Variation (PV): The part variation is the part of the total GRR study error that is due to the parts being measured.
Total Variation (TV): The total variation is the RSS (root-sum-square) sum of the gage repeatability and reproducibility (including
interaction, if available) and the part variation. Total variation is an estimate of process variation that can be used when process
variation is unknown.
112 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Illustration of Gage Errors
The chart below illustrates several terms we have discussed. The three zigzag patterns show the pattern of Part Variation (PV), as
measured by three different Appraisers. These patterns vary a lot more than the control limits, which is good (the control limits
show the variation to be expected due to Repeatability (EV), if we always measured the same part). The three patterns are not
close in height, which is an error called Reproducibility (AV). The three patterns are not close in shape, which is an error called
Appraiser × Part Interaction (INT).
MSA Menu
In the main menu, click MSA Suite to see the list of available studies:
You can also run MSA by clicking the MSA button in Calibrations, though this restricts you to MSA studies for only that gage.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 113
Gage R&R
GRR studies look at the ability of a calibrated gage to measure an actual part characteristic using real operators and production
conditions. GRR studies are specific to a part characteristic and can apply to multiple gages.
Study Types
Information Tab
114 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
When you are ready to start entering your R&R measurements, click the tab for Appraiser A and enter the appraiser’s name in the
Appr A field. Next, click in the first column for Part 1. After you enter the measurement, press the Tab or Enter key and your cursor
will be blinking in the area for the first measurement for Part 2. Subsequent pressing of the Tab or Enter key after entering the
measurements will advance you to all of the parts and all of the trials for Appraiser. Click the tabs for Appraiser B and Appraiser C
(if required) and follow the same procedure.
If most of your measurements begin with the same numbers (such as 1.1651, 1.1650 and 1.1658), you can save time by prefilling
the measurements with those digits. In this case, click the Prefill button and then enter a prefill value of 1.165. Now you need to
enter only the last digit of each measurement. Before using this feature, enter the number of trials, appraisers and parts for the
study on the Information tab.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 115
Field/Button Name Description
Trials Select number of trials to be used for Prefill.
Parts Select number of parts to be used for Prefill.
Study Type Select ANOVA (preferred), Long AIAG or Short-AIAG.
MSA Version Refers to the Measurement Systems Analysis Reference Manual published by AIAG. Use Version 4 for new
studies. Existing Version 3 studies may be updated for new features by changing to Version 4. Updates are
reversible.
Nested ANOVA Appears only when ANOVA study type is selected. Select if trials are non-replicable.
Approved Select when study is approved
Comments Enter any comments you wish to note.
Number Format Select the format you want for calculations.
Co. Part No. You can enter your internal company part or job number in this field.
Part No. Select a related part number, such as the customer or supplier part number.
Part Desc. The description or name of the part appears in this field.
Characteristic Enter the characteristic that you’re evaluating in the study.
Specification Limits Be sure to enter the minimum and maximum Specification Limit values; otherwise, the software can’t
calculate the %tolerance values for your study.
6-Sigma Proc. Var. If you know the 6-Sigma Process Variation of the characteristic that you’re measuring, enter it here. This
causes the program to use this value instead of estimating part variation from your sample of study parts. If
you know the standard deviation of the characteristic (from SPC or Capability studies), multiply it by six and
enter the result here. See your Process Engineer, or Quality Engineer for help.
Pp (or Ppk) Target A process capability or performance target may be entered (typically 1.33 or 1.67). GAGEtrak will use it to
reduce Tolerance to be an estimate of Process Variation.
The program calculates these fields when you click the Calc button. (Blank rows result if you used a Study Type that cannot
calculate a particular row).
116 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Column Name Description
Standard Dev Standard deviation (1s, not 5.15s) This is used for uncertainty calculations.
% Contribution (Proportion of Total Variation)2 This helps put things in perspective.
% of TV Percent of Total Variation This is the primary comparison tool.
% of Tol Percent of part Tolerance (based on 6s, not 5.15s). An alternate comparison tool
Interpreting GRR%
If you tend to think of gage improvement in terms of “reduced measurement variation” (reduced uncertainty), then you may prefer
GRR% over number of distinct categories, because with GRR%, reduced numbers are better.
Most manufacturing companies follow the Automotive Industry Action Group (AIAG) rules. If GRR as a percentage of Total Variation
(or % of Tolerance, whichever is more appropriate) is:
For every value of GRR%, there is a corresponding value of number of distinct categories, in a format that is roughly proportional
to the reciprocal of GRR%. Technically, there is no reason to use both measures at the same time. Whichever format you prefer
will provide equally complete information. The table below shows selected values of number of distinct categories and the
corresponding values for GRR%.
number 4.5 5 10 14 20 28 35
of distinct
categories
GRR% 29.9% 27.1% 14.0% 10.0% 7.0% 5.0% 4.0%
The usual reject limit for number of distinct categories is 5, which corresponds to 27%GRR. If you think it is important to have a
reject limit that is closer to the AIAG specification limit of 30%GRR, then use number of distinct categories = 4.5 as a minimum.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 117
Conversion Formula for number of distinct categories
For GRR% = 30, then number of distinct categories = 1.41((100/30)2 – 1)0.5 = 4.48
Note: This conversion formula is not used in GAGEtrak, but is presented here for information. If you want to verify the formula, just
compare it to results in GAGEtrak.
1. Myth: By using the specified number of categories you can eliminate errors in sorting situations such as making a
histogram. Fact: There is always significant probability of a one-category sorting error, because measurements and
actual values can fall on opposite sides of a boundary. However, being off by two categories is highly unlikely with
number of distinct categories. That is as good as it gets, but “error free” is an exaggeration.
2. Myth: Number of distinct categories is at 97% confidence. Fact: Number of distinct categories is not related to any
particular confidence level except when it is calculated based on tolerance. When based on tolerance/6 compared to
GRR the confidence level is 99.73%. To see where ideas about 97% confidence (and truncation) started, look at the
second part of the next paragraph.
To actually use the specified number of categories for sorting into a histogram you would need to choose a width for the categories.
Since we now can calculate number of distinct categories from tolerance, you would likely prefer to round that value to an integer,
and divide it into tolerance. The resulting category width would cover the entire tolerance. The authors that introduced number
of distinct categories chose a (typically narrower) category width by truncating number of distinct categories to an integer, and
dividing it into the equivalent of a 97% confidence interval for part variation (4.34 PV). Either category width would be suitable for
practical use.
To print the study report, click the This Study button that’s in the Print section. To preview the study report on-screen, click the
This Study button that’s in the View section. Use the Data Sheet buttons to print or preview a blank data collection sheet you can
118 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
use to record measurements during the study.
If you want the two-page report (the second page is an analysis report that includes more detail), check the Include Analysis Sheet
checkbox.
Generating Charts
The GRR Module offers an extensive variety of charts to help you determine the causes of measurement error. To generate a chart
from your Gage R&R study, click the Charts button and the Gage R&R Charts menu will appear. If you find that the calculate Y-Axis
for the chart is not ideal for graphing your data, check the Manually Enter Y-Axis Range checkbox before you click a chart button.
This will allow you to determine the range used for that chart.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 119
Printing or Sending Charts
Each chart can be printed or sent as an attachment via email; click the Print button in the report toolbar or the Email button in the
ribbon:
120 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Range Chart Interpretation
The Range chart can help you determine both statistical control in regard to repeatability and homogeneity of the measurement
process among appraisers for each part. Neither chart should show patterns in the data relative to the appraisers or parts. Out of
control points on this particular chart usually indicate typos or measurement mistakes. The suspect data will be flagged on one of
the Appraiser tabs.
Error Chart
The Error chart shows the individual deviations from the accepted reference values. GAGEtrak calculates the individual deviation or
error for each part according to the following formula:
Before you do any other statistical analysis, you should thoroughly screen the deviations for clear causes of variations that you can
ascribe to specific factors.
Look for any uniform patterns in your Error chart, including the following: one appraiser’s second (or third) set of readings is
consistently higher than his first; one appraiser’s average is higher than the other appraisers’ averages; and/or one part standing out
as more difficult to measure consistently.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 121
Run Chart and Average Chart
If the patterns are not at the same height there is a reproducibility error. If the patterns are not the same shape there is an
appraiser × part interaction error
The three zigzag patterns show the pattern of Part Variation (PV), as measured by three different Appraisers. These patterns vary
a lot more than the control limits, which is good (the control limits show the variation expected due to Repeatability (EV), as if we
always measured the same part). The three patterns are not close in height, which is called Reproducibility (AV) error. The three
patterns are not close in shape, which is called Appraiser × Part Interaction (INT).
122 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Normalized Individuals Chart (by Part/Appraiser and by Appraiser/Part)
In this chart, the plotted data consists of the individual readings minus the overall average of the readings. The normalized data is
plotted grouped by appraiser or part number. This chart can help you determine reproducibility; consistency among appraisers;
occurrences of abnormal readings; and the interaction between the parts and appraisers.
Whiskers Chart
The Whiskers chart plots and connects the high and low data values and the average by part by appraiser. This chart helps you
see consistency among appraisers; occurrences of abnormal readings; and the interaction between the parts and the appraisers.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 123
X–Y Plot of Averages by Size
This chart plots the averages of each appraiser’s various readings for each part, using the overall part average. If the appraisers
disagree on certain parts (Appraiser × Part interaction) this can help to determine whether that depends on part size.
124 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Scatter Plot
The Scatter Plot charts individual readings by appraiser by part to help you determine consistency among appraisers; occurrences
of abnormal readings; and the interaction between the parts and appraisers.
With the Range Control chart, you can determine whether repeatability is the same for all appraisers (the numerical methods do
not answer this question).
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 125
Part Appraiser Average Control Chart
Using a standard average chart, the averages of each appraiser’s readings for each part are plotted, including the overall average
and control limits. Appraiser groups the data with lines connecting each appraiser’s points.
If half or more of the points are outside of the control limits, then the measurement system should be able to detect part-to-
part variation. If less than half is outside the control limits, it might be because the measurement system isn’t able to thoroughly
distinguish differences or because the part sample doesn’t represent the expected process variation.
126 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Gage R&R Formulas
Parts 1 2 3 4 5 6 7 8 9 10
2 Appr’s 1.41421 1.27931 1.23105 1.20621 1.19105 1.18083 1.17348 1.16794 1.16361 1.16514
3 Appr’s 1.91155 1.80538 1.76858 1.74989 1.73857 1.73099 1.72555 1.72147 1.71828 1.71573
EV = Not calculated
AV = Not calculated
GRR = 1 ÷ d *2 × R
or
Trials 2 3
K1 0.8862 0.5908
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 127
Appraiser Variation (AV) – Reproducibility
Appr’s 2 3
K2 0.7071 0.5231
Note: If a negative value results under the square root, the AV is reported as “0”.
or if comparing to tolerance:
Parts 2 3 4 5 6 7 8 9 10
K3 0.7071 0.5231 0.4467 0.4030 0.3742 0.3534 0.3375 0.3249 0.3146
Rp = Max Xp - Min Xp
Note: If you know the 6-Sigma Process Variation (from SPC or Capability studies), enter it into the Proc. Var. field.
If entered into the Gage R&R Study form, the software will calculate TV as:
128 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Total Variation (TV)
ANOVA Formulas
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 129
130 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Sample ANOVA Study
This section contains data and calculations for a sample ANOVA study. You can use this sample study as a model for your own
ANOVA studies.
Readings
Appraiser A
Total = 16.55
SS Total = 14.27
Appraiser B
Total = 15.35
Sum Square Total = 12.63
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 131
Appraiser C
Total = 16.55
Sum Square Total = 14.40
Legend
132 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Study Values
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 133
Parts Sum Square
134 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
ANOVA Table
Source DF SS MS F F0.25
Appraiser 2 0.048 0.024
Parts 9 2.057 0.2286
App. x Parts 18 0.106 0.0059 4.5385 1.310
Gage Error 30 0.039 0.0013
Total 59 2.249
Components of Variance
Most of these values are calculated using values from an F-distribution table. You can find F-tables in most statistics manuals.
Sum Squares
Table S2
AV 0.00091
PI 0.03716
I 0.00223
EV 0.00129
RR 0.00444
TV 0.04165
Study Variation
Repeatability
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 135
Reproducibility
Part x Appraiser
GRR
Part to Part
136 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Linearity, Bias and Uncertainty
If a linearity study is to represent an entire family of gages, you may want to use a different gage for each reference value. Then
the repeatability of calibration will actually be GRR of calibration because it will include appraiser variation. (Appraiser variation can
refer to gages, operators, or laboratories) You could even use two technicians, by letting each do half of the trials.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 137
Linearity
Enter three to five reference values in the Part Ref. Values area. The smallest reference values should be entered as 1 and the
largest reference values entered as 5. Click the Trials tab to begin entering the measurements for each size. Start with Column 1.
Press the Tab or Enter key to advance to the next measurement for Column 1 until all 12 measurements have been entered. Follow
the same procedure for the rest of the columns.
138 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Trials Tab
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 139
Field/Button Name Description
Pp (or Ppk) Target A process capability or performance target may be entered (typically 1.33 or 1.67). GAGEtrak will use it to
reduce Tolerance to be an estimate of Process Variation.
6-Sigma Proc. Var. If you know the 6-Sigma Process Variation of the characteristic that you’re measuring, enter it here. It will be
divided by 6 and used for Total Variation TV.
Use Range Method for Bias If you want this option, select Yes from the drop down list. Otherwise, GAGEtrak uses standard deviation.
Number Format Choose desired format from the drop down list.
Percentage Format Choose desired format from the drop down list.
Part Reference Values 1–5 Enter three to five Part Reference Values for Linearity & Bias. Enter one for Bias Only Studies.
(required)
Trials 1-12 or 1-60 (required) Enter 5 to 12 for each reference value or 5 to 60 for Bias Only studies (required).
140 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
To print the study report, click the This Study button that’s in the Print section. To preview the study report on-screen, click the
This Study button that’s in the View section. Use the Data Sheet buttons to print or preview a blank data collection sheet you can
use to record measurements during the study.
Linearity Chart
To generate a Linearity chart, click the Chart button. You’ll see a plot of individual and average Bias versus Reference Value, as well
as a best-fit linear regression line and bow-tie-shaped confidence limits. To be acceptable, the zero Bias line must fit within the
confidence limits.
Histogram
The Histogram is discussed under Bias tab.
You can also evaluate goodness of fit by looking at the chart. If the fit is adequate, then apply three criteria:
1. The horizontal zero bias line on the chart should fit within the confidence limits.
2. The absolute value of the t Statistic for Slope should not be larger than t Critical.
3. The absolute value of the t Statistic for Intercept should not be larger than t Critical.
If the regression line does not fit well, do not apply the above criteria. Study the chart for evidence of non-linearity. Non-linearity
can be acceptable if bias per part is always near zero.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 141
If a measurement system has significant linearity error, look for these possible causes:
1. Gage not calibrated properly at lower and upper ends of the operating range
2. Error in the minimum or maximum master
3. Worn instrument
4. Internal instrument design characteristics
5. Mistakes in measurement or typos
If there is significant linearity error that cannot be eliminated, you may be able to use the gage by using the regression equation to
correct future measurements. In the automotive industry, this requires customer permission.
Bias Tab
This tab analyzes the bias for Linearity & Bias, as well as Bias Only Studies. Enter Study Type and Part Reference values on the
Linearity tab and then enter data in the Trials tab before coming to the Bias tab.
Note: Bias studies using the control chart method are part of the Stability Module and are not included in this module.
142 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
The Bias tab calculates the following fields:
Histogram
This chart is used to show the central tendency, spread and shape of the distribution of Bias values.
Example Histogram
1. Gage not calibrated properly at lower and upper ends of the operating range
2. Error in the minimum or maximum master
3. Worn instrument
4. Internal instrument design characteristics
5. Mistakes in measurement or typos
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 143
Uncertainty Tab
Uncertainty refers to the potential variation of gage error that accumulates in the chain of calibrations from NIST through various
intermediate calibration labs to the final calibration of a “working gage” and its use in a production environment. At each
intermediate stage of calibration, the uncertainty increases because the input uncertainty will be combined with new uncertainty
contributors to create an output uncertainty that is always larger. Each uncertainty along the way is communicated to the next link
in the chain by a calibration certificate or test report. Each certificate maintains “traceability” to the original NIST calibration by
citing the NIST number. This system of traceability is important because, without it uncertainty would inevitably grow to the point
where customers and suppliers could not trust each other’s measurements.
Reasonable estimation [of uncertainty] shall be based on knowledge of the performance of the method and on the scope and
shall make use of, for example, previous experience and validation data. Sources contributing to the uncertainty include, but are
not necessarily limited to, the reference standards and reference materials used, methods and equipment used, environmental
conditions, properties and condition of the item being tested or calibrated, and the operator.
The uncertainty contributors to be included are selected on the basis of judgment and knowledge of the measurement method.
Items selected are designated as “Type A,” which means derived from an MSA study, or “Type B,” which means some other
source such as a certificate, or an experience-based educated guess.
Keep in mind that uncertainty is not an estimate of gage error; it is the potential variability in gage error, i.e., the extent to which
gage error is unknown.
Here are some examples of potential uncertainty contributors, and where they come from. This is not an exhaustive list.
144 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
General Uncertainty Contributors (Type B)
These may apply to both uncertainty of calibration and uncertainty of measurement.
Details about each of these potential uncertainty contributors are given a few paragraphs below, in Background on Uncertainty
Contributors.
The Type A or Type B classification depends on whether you do a statistical study (A) or not (B). Thus, if you estimate stability error
without doing a study, it becomes Type B instead of Type A. Likewise, if you do a statistical study to determine the uncertainty of
temperature difference, it becomes Type A instead of Type B.
The task of determining uncertainty for a calibration or a laboratory measurement involves deciding which uncertainty contributors
are to be included and listing them on a form called an Uncertainty Budget or error budget. This form combines all the contributors
for you, using RSS root-sum-square addition, and calculates Expanded Uncertainty for use on certificates or test reports.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 145
The columns are explained in the table below.
Column Description
Uncertainty Contributor The type of measurement error variation to be considered as a contributor.
Type Everything on this sub-tab is “Type A,” meaning it was determined from observation and statistics.
Plus or Minus The amount of plus or minus variation that was observed, expressed as a maximum deviation or a standard
deviation.
Probability Distribution The assumed pattern of variation for each type of error. See Background on Probability Distributions.
Based on The information or calculation that was used to determine the Plus or Minus value.
DF Degrees of Freedom. Think of DF as the “effective sample size” of the Plus or Minus value. This will be less
than the actual sample size, depending on the method of calculation. The Uncertainty Budget will use DF to
determine a “t Statistic.”
Include Select Yes or No to determine whether an item is to be included in the Uncertainty Budget. This is the only
column you can change.
The question of when to include an Uncertainty Contributor in the Uncertainty Budget is discussed in the table below.
When your choices have been made, click Update Budget. This will partially fill out the Uncertainty Budget.
146 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Uncertainty Budget Sub-tab
Up to four rows will already have been filled in according to the choices you made in Uncertainty Setup. You may edit these
choices here, and doing so will not change Uncertainty Setup. To enter additional Uncertainty Contributors, select from the drop-
down list in an empty row. You may add to most of the drop-down lists. Just type an entry or modify an existing entry. The added
item will appear the next time you open this module.
Column Description
Uncertainty Contributor Select the type of measurement error to be included, or type in a new one.
Type Choose Type A if the Plus or Minus value will be based on statistical observations. Choose type B if this is
based on certificates, or experience.
Plus or Minus Enter the Plus or Minus variation caused by this contributor.
Probability Distribution Select a Probability Distribution from the drop-down list or key in a new one. See Background on
Probability Distributions below.
Divisor GAGEtrak will fill this in if it recognizes the Probability Distribution. You may change it. See Background on
Probability Distributions, below.
Sensitivity Coefficient If the Plus or Minus value is in the proper units, and applies directly, then use the default value of one. If
the units must be converted, or adjusted, insert the proper multiplier here. For example, the Plus or Minus
value might be in temperature units, and you wish to use length and the coefficient of thermal expansion
for this material to convert to millimeters.
Uncertainty Contribution This is the “standard uncertainty,” or standard uncertainty times the Sensitivity Coefficient. It will appear
when you click on the Calc button. You cannot change it.
DF For Type A items, insert the Degrees of Freedom here. If unknown, you may leave it blank (blanks will be
treated as infinite). Degrees of Freedom for Type B items are Infinite by default.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 147
Click on the Calc button and GAGEtrak automatically calculates these fields.
Normal Distribution
The bell-shaped probability distribution occurs so frequently that it is named “Normal.” When a quantity is influenced by a
large number of variables (as is usually true), the pattern of variation will tend to be Normal. The Plus or Minus variability of this
distribution is expressed as some multiple of the standard deviation, such as 1s, 2s or 3s. When entering these Plus or Minus
values, choose Normal (1), Normal (2) or Normal (3) and GAGEtrak will select the appropriate Divisor to be used to convert to
a standard uncertainty (1s). When you run into something different, like 1.96 s, just enter Normal for Probability Distribution
and 1.96 for Divisor. When you run into total variation like 6s or 5.15s, you can enter Normal and specify a divisor of, say, 5.15.
You could also divide by two before entering the Plus or Minus value and enter a Divisor of 2.576. Note that GAGEtrak currently
displays and prints GRR value as 1s, but other software or old printouts of GAGEtrak GRR studies may have been using 5.15s.
Rectangular Distribution
This is the distribution of choice when you have no idea what the real distribution is. This distribution occurs when something
varies between limits, from one extreme to the other. An example would be air temperature as controlled by a thermostat. Enter
the plus or minus value as one-half the difference between the extremes. GAGEtrak will select a Divisor of 3 = 1.732. Note: For
temperature of solid objects see U-shaped Distribution below.
Triangular Distribution
This distribution occurs when two Rectangular distributions combine to form a third distribution. An example would be summing
a pair of dice. Choose this distribution when you believe a distribution is “not quite Normal.” Enter the Plus or Minus value as one-
half the difference between the extremes. GAGEtrak will choose a Divisor of 6 = 2.449.
U-Shaped Distribution
Choose this when you believe that the extremes are more likely than values at the center. An example would be temperature
of solid objects when controlled by a thermostat. The variation will resemble a sine wave when viewed on a time scale and will
produce a U-shape when viewed as a distribution. Enter the Plus or Minus value as one-half the difference between the extremes.
GAGEtrak will use a Divisor of 2 = 1.414.
148 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Background on Uncertainty Contributors
The following are not complete lists.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 149
General Uncertainty Contributors (Type B)
These apply both to uncertainty of calibration and uncertainty of measurement.
Linearity Formulas
x = reference value
y = observation – x
b = intercept
a = slope
m = subgroup size
g = number of subgroups
ŷ = predicted bias
R2 = goodness of fit
df = degrees of freedom
150 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 151
Bias Formulas
152 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Uncertainty Formulas
p = plus or minus value
d = divisor
c =sensitivity coefficient
uc = combined uncertainty
k = coverage factor
U = expanded uncertainty
df for uncertainty of linearity are not specified in the usual literature. GAGEtrak uses the df from d *2 row 1.1 as a reasonable
estimate. The following Weibull approximation of df from d *2 row 1.1 is used for gm > 20:
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 153
Stability (and Bias)
When we choose a calibration frequency of, say, every 6 months it is in the assumption, or hope, that the gage calibration
will remain stable for that length of time. A Stability Study verifies this assumption to see if it is true. Plotting a control chart of
calibration, for a particular reference standard, does this. For example, we could check a 1 inch gage block 3 times and do this
once a week for 25 weeks, or once every two weeks for 50 weeks. (Automotive requirements call for a minimum of 25 data points
to establish stability).
During the study, adjustments are not usually made unless there is an instability signal. Instability signals include 1 point out of
limits, 2 points out of 3 beyond 2/3 of a limit, or 7 points in a row on the same side of the central line (some industries use 8 or 9
points in a row). See one of the references on statistical process control (SPC) for more information. The X bar, or X, chart detects
changes in bias. If these charts are stable it means the bias did not change and GAGEtrak can calculate the bias (as long as you
are able to enter a reference value for the reference standard or retained sample that was used). If the chart shows a shift or drift in
bias, the amount of change (estimated visually) is the Stability contribution to uncertainty. Note: if bias was not stable, the estimate
of bias in this study should not be used.
The R, s and MR charts detect changes in repeatability of calibration. If the chart shows a shift or drift in repeatability, the amount
of change (estimated visually) is the Consistency contribution to uncertainty.
Information Tab
154 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Each of the fields in the Information tab screen is explained in the table below.
To see the following fields, enter data on the Data tab and click the Calculate button. These estimates should not be used unless
the control charts have been confirmed to be stable. If the charts discussed below do not appear stable, the following estimates
will be incorrect.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 155
Creating an Uncertainty Budget for Bias by Control Chart Method
Go to the Linearity, Bias and Uncertainty module and set up the Linearity tab. Choose Study Type Bias Only and enter 0 as a single
reference value (or you can do a linearity study with real data if you prefer). Indicate in Comments that Bias values will come from
the Stability module and specify study date. Enter a column of 5 zeros in trials. Then setup an Uncertainty Budget like this:
To complete the Uncertainty Budget, enter the following from the Stability module.
1. For Bias, enter Standard Error as the Plus or Minus value and df.
2. Enter Resolution; if you want to use half, enter 0.5 as a Sensitivity Coefficient.
3. For Repeatability, enter Standard Dev as the Plus or Minus value and df.
4. Enter any additional items you wish and press Calc.
156 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Data Tab
To add stability sub group measurements, click on the first row in the Sub Group table. Each sub group row represents the values
of the repeated master (or master part) measurements that you make. You must use the same number of readings for each sub
group of measurements; for example, you shouldn’t use a sample size of five repeated readings on your first sub group and then
use only three repeated readings on your second sub group. Add additional sub groups to the rows following the first sub group
row.
Note: Subgroup sizes of 3 to 5 are common for stability studies. GAGEtrak can accommodate subgroup sizes of 1 to 10.
The subgroup record fields are explained below (use the table’s horizontal scroll bar to view the fields on the right side of the table).
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 157
Field Name Description
Xbar ( X ) In this field, you’ll see the average (arithmetic mean) for the sub group. This value is calculated; you can’t
change it.
MR In this field you’ll see the Moving Range between this subgroup average and the previous subgroup
average. This will be blank for the first subgroup.
Notes Record any comments in this field.
To print the study report, click the This Study button that’s in the Print section. To preview the study report on-screen, click the
This Study button that’s in the View section. Use the Data Sheet buttons to print or preview a blank data collection sheet you can
use to record measurements during the study.
158 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
X bar & R Charts (Gage R&R Charts)
These charts will be familiar to many users because they are used extensively in manufacturing. They work best for small subgroup
sizes, and are not recommended for subgroup sizes of 9 or 10. They do not work for a subgroup size of 1.
Note: Despite the name “Individual Chart,” when the subgroup size is greater than 1, averages are plotted).
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 159
Histogram
This chart is used to show the central tendency, spread, and shape of the distribution.
Example Histogram
These are calculated from the data, unless you specified to use historic values for X bar and Sigma.
g = number of subgroups
X0 = reference value
R = Range
X= subgroup average
A2, A3, B3, B4, C4, d2, D3, D4 = control chart constants based on value of m, as shown in the table below:
160 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
m A2 A3 D3 D4 c4 B3 B4
2 1.87997 2.658679 0 3.267 0.797885 0 3.267
3 1.02333 1.954410 0 2.574 0.886227 0 2.568
4 0.72865 1.628102 0 2.282 0.921318 0 2.266
5 0.57682 1.427299 0 2.115 0.939986 0 2.089
6 0.48325 1.287128 0 2.004 0.951533 0.030 1.970
7 0.41928 1.181916 0.076 1.924 0.959369 0.118 1.882
8 0.37253 1.099096 0.136 1.864 0.965030 0.185 1.815
9 0.33670 1.031661 0.184 1.816 0.969311 0.239 1.761
10 0.30826 0.975350 0.223 1.777 0.972659 0.284 1.716
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 161
g 2 3 4 5 6 7 8 9 10
1.1 1.0 2.0 2.9 3.8 4.7 5.5 6.3 7.0 7.7
1.2 1.41421 1.91155 2.23887 2.48124 2.67253 2.82981 2.96288 3.07794 3.179905
2.1 1.9 3.8 5.7 7.5 9.2 10.8 12.3 13.8 15.1
2.2 1.27931 1.80538 2.15069 2.40484 2.65438 2.76779 2.90562 3.02446 3.12869
3.1 2.8 5.7 8.4 11.1 13.6 16.0 18.3 20.5 22.6
3.2 1.23105 1.76858 2.12049 2.37883 2.58127 2.74681 2.88628 3.00643 3.11173
4.1 3.7 7.5 11.2 14.7 18.1 21.3 24.4 27.3 30.1
4.2 1.20621 1.74989 2.10522 2.36571 2.56964 2.73626 2.87656 2.99737 3.10321
5.1 4.6 9.3 13.9 18.4 22.6 26.6 30.4 34.0 37.5
5.2 1.19105 1.73857 2.09651 2.35781 2.56263 2.72991 2.87071 2.99192 3.09808
6.1 5.5 11.1 16.7 22.0 27.0 31.8 36.4 40.8 45.0
6.2 1.18083 1.73099 2.08985 2.35253 2.55795 2.72567 2.86680 2.98829 3.09467
7.1 6.4 12.9 19.4 25.6 31.5 37.1 42.5 47.6 52.4
7.2 1.17348 1.72555 2.08543 2.34875 2.55465 2.72263 2.86401 2.98568 3.09222
8.1 7.2 14.8 22.1 29.2 36.0 42.4 48.5 54.3 59.9
8.2 1.16794 1.72147 2.08212 2.34591 2.55208 2.72036 2.86192 2.98373 3.09039
9.1 8.1 16.6 24.9 32.9 40.4 47.7 54.5 61.1 67.3
9.2 1.16361 1.71828 2.07953 2.34370 2.55013 2.71858 2.86528 2.98221 3.08896
10.1 9.0 18.4 27.6 36.5 44.9 52.9 65.6 67.8 74.8
10.2 1.16514 1.71573 2.07746 2.34192 2.54856 2.71717 2.85898 2.98100 3.08781
11.1 9.9 20.2 30.4 40.1 49.4 58.2 66.6 74.6 82.2
11.2 1.15729 1.71363 2.07577 2.34048 2.54728 2.71650 2.85791 2.98000 3.08688
12.1 10.7 22.0 33.1 43.7 53.8 63.5 72.6 81.3 89.7
12.2 1.15490 1.71189 2.07436 2.33927 2.54621 2.71504 2.85702 2.97917 3.08610
13.1 11.6 23.8 35.8 47.3 58.3 68.7 78.6 88.1 97.1
13.2 1.15289 1.71041 2.07316 2.33824 2.54530 2.71422 2.85627 2.97847 3.08544
14.1 12.5 25.7 38.6 51.0 62.8 74.0 84.7 94.9 104.6
14.2 1.15115 1.70914 2.07213 2.33737 2.54452 2.71351 2.85562 2.97787 3.08487
15.1 13.4 27.5 41.3 54.6 67.2 79.3 90.7 101.6 112.1
15.2 1.14965 1.70804 2.07125 2.33661 2.54385 2.71290 2.85506 2.97735 3.08438
16.1 14.3 29.3 44.1 58.2 71.7 84.5 96.7 108.4 119.5
16.2 1.14833 1.70708 2.07047 2.33594 2.54326 2.71237 2.85457 2.97689 3.08395
17.1 15.1 31.1 46.8 61.8 76.2 89.8 102.8 115.1 127.0
17.2 1.14717 1.70623 2.06978 2.33535 2.54274 2.71190 2.85413 2.97649 3.08358
18.1 16.0 32.9 49.5 65.5 80.6 95.1 108.8 121.9 134.4
18.2 1.14613 1.70547 2.06917 2.33483 2.54228 2.71148 2.85375 2.97613 3.08324
19.1 16.9 34.7 52.3 69.1 85.1 100.3 114.8 128.7 141.9
19.2 1.14520 1.70480 2.06862 2.33436 2.54187 2.71111 2.85341 2.97581 3.08294
20.1 17.8 36.5 55.0 72.7 89.6 105.6 120.9 135.4 149.3
20.2 1.14437 1.70419 2.06813 2.33394 2.54149 2.71077 2.85310 2.97552 3.08267
d2 1.12838 1.69257 2.05875 2.32593 2.53441 2.70436 2.84720 2.97003 3.07751
cd 0.8765 1.8150 2.7378 3.6230 4.4658 5.2673 6.0305 6.7582 7.4539
For g > 20 use d2, and estimate df with the constant difference cd.
162 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Attribute Risk Analysis
Attribute gages produce binary outputs like pass or fail and zero or one. To perform this study, you need to select fifty parts with a
range of measurement values that extends all the way from out of specification at the lower specification limit to out of specification
at the upper specification limit. You will need three appraisers who check each part in random order and then check them all
again in a different random order, for a total of 3 trials per appraiser.
This procedure is similar to a study in previous versions of GAGEtrak called the Short Attribute study. The Short Attribute study
involved only twenty parts and published requirements called for perfect agreement. New requirements allow a modest amount of
disagreement within or between appraisers.
Gage theory tells us that a part made exactly on a specification limit would have a fifty-fifty chance of being accepted by a perfect
gage that has no bias. This is true for both attribute and variable gages. (For customer protection, attribute gage manufacturers
deviate from theory and shoot for slightly less than 50% acceptance at the specification limit).
Because all gages, attribute and variable, have repeatability and reproducibility problems, parts made too near a specification limit
will experience inevitable disagreements between and within appraisers.
This module will compare pairs of appraisers and perform hypothesis tests to determine if there is sufficient agreement. If a
variable gage is available that can check the same parts, GAGEtrak will compare attribute and variable decisions and calculate
gage repeatability and reproducibility (GRR) for the attribute gage. If variable measurements are not feasible, you can substitute
attribute reference values from an authoritative attribute source (the customer, perhaps).
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 163
Information Tab
164 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Input Tab
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 165
Crosstabs Tab
Field/Button Description
A*( ) Crosstabulation Select which pair of Appraisers you want to evaluate.
Count The number of times the two selected Appraisers voted a particular way. For example, suppose there were
6 times A said Fail and B said Pass.
Expected The number of times we would expect a particular vote combination to occur based on the totals.
Totals The totals for each column and row.
Kappa The Kappa statistic measures agreement, on a scale of zero to one. Over 0.75 is considered good, under
0.40 is considered poor.
166 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Effectiveness Tab
The following fields and buttons are available; and apply to each column in which they appear. There are comparisons of each
appraiser to themselves, each other, and the reference values from the variable gage.
Field/Button Description
Total Inspected Number of parts inspected.
# Matched Number of parts with consistent ratings.
False Negative Number of parts that were consistently rejected by the appraiser and accepted by the variable gage.
False Positive Number of parts that were consistently accepted by the appraiser and rejected by the variable gage.
Mixed Number of parts where an appraiser had inconsistent results.
95% UCL A 95% Upper Confidence Limit for the Effectiveness score.
Effectiveness Percent of parts that consistently matched. This number should be within the confidence bounds for the
other appraisers.
95% LCL A 95% Lower Confidence Limit for the Effectiveness score.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 167
Miss Rate Analysis Tab
The following fields compare each appraiser to the reference value from a variable gage. The system column compares the
appraisers, as a group, to the reference values from the variable gage.
168 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Miss Rate Per Part
Field/Button Description
Effectiveness per part The percent of parts that consistently matched the variable gage.
False Alarm Rate The percent of parts that were accepted by the variable gage and had at least one rejection by the
appraisers.
Miss Rate per Part The percent of parts that were rejected by the variable gage and had at least one acceptance by the
appraiser(s).
Total The percentages add up to 100%.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 169
Signal Detection Tab
If reference values are available from a variable gage, this tab estimates Gage Repeatability (GRR) for the attribute gage.
Field/Button Description
GRR for Attribute Gage GRR is estimated as the range from consistently “out” to consistently “in”. If the study includes Upper
and Lower Specification Limits GRR will be an average range, and GRR% of Tol will also be calculated.
Assuming the attribute gage is for sorting or validation, and is not used for process control, the criterion is
GRR % of Tol of 10% or less is acceptable. GRR % of Tol over 30% is unacceptable.
GRR for Variable Gage The GRR that was entered on the information tab.
% of TV GRR divided by Total Variation. Under 10% is acceptable, 10 to 30% may need improvement, over 30% is
not acceptable.
% of Tol GRR divided by Tolerance. Under 10% is acceptable, 10 to 30% may need improvement, over 30% is not
acceptable.
1-50 The Reference Values from the variable gage sorted in ascending order, and the corresponding Appraisal
Signal.
170 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Crosstabulation Formulas
OC = observed count
EC = expected count
Attribute Analytic
Gage theory tells us that a gage with no bias should have a fifty-fifty probability of accepting a part that was made exactly on
a specification limit. That is true of both attribute and variable gages. It is also true for both types of gages, that because of
repeatability problems, parts just inside the limit will have a probability of acceptance that gradually increases to 100%, and parts
just outside the limits will have a probability of acceptance that gradually decreases to 0%. A chart called a Gage Performance
Curve shows how this works for both attribute and variable gages:
The chart shows how the probability of acceptance gradually changes in an ∫ curve near the Specification Limits. The horizontal
width of the ∫ curve is about six times the Repeatability, and the horizontal distance between a specification limit and the 50% point
on the curve is Bias. With the data for making this chart GAGEtrak is able to calculate Repeatability and Bias for an attribute gage.
To plot this chart for attribute gages we need parts that are made near, and on both sides of, a specification limit. The study can
be done at either specification limit, or at both limits. We need variable measurements in addition to attribute data for each part
used in the study. Only eight parts are needed for the study, but since we need to find parts that meet certain criteria we often
have to check more than eight parts. The attribute data consists of checking each part twenty times and recording how many
times the part is accepted. We do this until we have found at least one part that is accepted zero times, at least one part that is
accepted twenty times, and at least six parts with acceptance counts that can be anywhere from one to nineteen. In case there
are extra parts, GAGEtrak will allow up to three entries for each acceptance count. (In case there are more than three parts for a
certain acceptance count, there are instructions on how to choose which three to include).
When you click the Calc button, GAGEtrak adjusts the percent accepted for each part and converts it to a “normal score” which
makes the ∫ curves plot as diagonal straight lines. GAGEtrak then uses linear regression to calculate repeatability and bias.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 171
Information Tab
172 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Lower Specification Tab
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 173
Upper Specification Tab
174 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Gage Performance Curve
This chart shows how the probability of acceptance gradually changes in an ∫ curve near the Specification Limits. The horizontal
width of the ∫ curve is about six times the repeatability, and the horizontal distance between a specification limit and the 50% point
on the curve is bias. The repeatability and bias are not necessarily the same at both specification limits.
This chart shows how the probability of acceptance gradually changes in an ∫ curve near the Specification Limits. The horizontal
width of the ∫ curve is about six times the Repeatability, and the horizontal distance between a specification limit and the 50%
point on the curve is Bias.
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 175
Attribute Analytic Formulas
C = acceptance count
b = intercept
n = sample size
C 0 1 2 3 4 5 6 7 8 9
P 0.025 0.075 0.125 0.175 0.225 0.275 0.325 0.375 0.425 0.475
x -1.96 -1.44 -1.15 -0.93 -0.76 -0.65 -0.45 -0.32 -0.19 -0.06
C 10 11 12 13 14 15 16 17 18 19 20
P 0.5 0.525 0.575 0.625 0.675 0.725 0.775 0.825 0.875 0.925 0.975
x 0.00 0.06 0.19 0.32 0.45 0.65 0.76 0.93 1.15 1.44 1.96
Note: When there are multiple parts with a count of zero (or twenty), only the one closest to the average will be used in the linear
regression. The extra parts will be plotted on the charts, but will not affect calculations.
176 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
Separate linear regressions are done for upper and lower specification limits. The custom for these charts is opposite of the
usual practice: x, or P, will plot on the vertical scale, and y will plot on the horizontal scale.
The 1.08 empirical correction factor compensates for the adjustment that was made above to the P values. On the probability plot,
the regression line ends at ± 2.576/1.08.
MSA v2 studies
For customers coming to the current versions of GAGEtrak from earlier versions, the MSA v2 are provided for backward
compatibility so that users can view older records created in those versions. Hence, they cannot be used for new records. There
are five options for MSA v2 studies; namely, MSA2 Gage R&R, MSA2 Linearity, MSA2 Stability, MSA2 Attribute and MSA2
ANOVA. Please refer to the older manuals for a description of these options.
Other Techniques/References
GAGEtrak includes the basic measurement system analysis (MSA) techniques. These rely on proven statistical tools such as
Confidence Interval Determination, Control Charting, Performance Curve Plotting, and ANOVA. For more information on how the
tools work, see, especially NIST/SEMATECH, Duncan, or Box in the list below. To view the studies in GAGEtrak see AIAG chapter
3. To see alternative or special purpose applications for MSA, see AIAG, or NIST/SEMATECH. For examples using uncertainty to
summarize MSA studies, see EA-4/02 and NIST/SEMATECH (where websites are referenced, the publications can be freely viewed
online, downloaded, or both).
We used the following publications as references in developing MSA studies; we recommend them to expand your understanding
of measurement system analysis: AIAG, MSA Measurement Systems Analysis Reference Manual, Forth Ed., Chrysler Group, Ford,
General Motors, 2010 (highly recommended—to order a copy, call AIAG at (248) 358-3570 and ask for document number “MSA”).
GAGEtrak 7 User Guide User Guide Chapter Eleven: MSA Suite 177
AIAG, MSA Measurement Systems Analysis Reference Manual, Third Ed., Daimler Chrysler, Ford, General Motors, 2002 (highly
recommended—to order a copy, call AIAG at (248) 358-3570 and ask for document number “MSA”).
ASTM, Special Technical Publication 15D, Manual on Presentation of Data and Control Chart Analysis, 1976.
BOX, G. E. P., Hunter, W. G., Hunter J. S., Statistics for Experimenters, John Wiley & Sons, New York, 1978.
DUNCAN, A.J., Quality Control and Industrial Statistics, Fourth Ed., Richard D. Irwin, Inc., Homewood, Illinois, 1974.
GRUBBS, F. E., “Errors of Measurement, Precision, Accuracy and the Statistical Comparison of Measuring Instruments,
Technometrics”, Vol. 15, February 1973.
HICKS, C. R., Fundamental Concepts in the Design of Experiments, Holt, Rinehart and Winston, New York, 1973.
ILAC, G17:2002, Introducing the Concept of Uncertainty of Measurement in Testing in Association with the Application of the
Standard ISO/IEC 17025, 2002, www.ilac.org.
NIST, TN 1297, Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, 1994, www.nist.gov/
public_affairs/pubs.htm
WESTERN ELECTRIC, AT&T Statistical Quality Control Handbook, Charlotte, NC, Delmar Printing Company, 1984.
178 User Guide Chapter Eleven: MSA Suite GAGEtrak 7 User Guide
User Guide Chapter Twelve:
Reports
Report Viewer
GAGEtrak includes a large variety of standard reports. The Report Viewer runs separately from GAGEtrak, so you can view a report
while simultaneously accessing records in GAGEtrak to search for and verify records. To generate reports, from the main menu,
navigate to Reports -> Report Viewer.
Application Icon
Click the application icon in the upper left corner of the Report Viewer window for a menu of options; most of these options
are also available from the Ribbon.
Option Description
Open a report; clicking the Report icon displays the Report Selector window.
Once your settings are complete, click OK to save the settings and close the window.
The Output To command allows you to transmit reports to Rich Text Format (*.rtf), Portable Document
Format (*.pdf), Microsoft Excel (*.xls) and Tagged Image Format (*.tif). If you save a file in .rtf format
and then open that file in a word processing application, such as Microsoft Word, your data will have the
appearance and formatting of the GAGEtrak report that you exported. Output to an Excel spreadsheet is
the best option to select when you wish to export a report. Choose Portable Document Format to create
a report that appears identical to the report you see in GAGEtrak; others will be able to print (but not edit)
this report even if they do not have GAGEtrak, as long as they have the free Adobe Reader.
EMAIL REPORT
Selecting Email Report will open this window, allowing you to specify file format and email text:
Staff email addresses will appear in the drop-down list in the Enter Email Addresses field. Select multiple
addresses from the list or manually enter addresses; multiples must be separated by a semicolon.
ABOUT
Open the About window to see general, database, license and system information:
HELP
Click Help to view Report Viewer’s Help System. The Help System can be browsed by the table of
contents or index or a broad search can be done. The contents of the Help System are identical to that
of the User Guide PDF file.
Capture to File: Clicking this option will take a screen shot of the current Report Viewer window and save
it to a file in Bin folder of the Report Viewer installation files. The default file path is: C:/ProgramData/
CyberMetrics Corporation/GAGEtrak 7.0 Report Viewer/bin. The file name of the screen shot is shown in
the bottom left corner of the Report Viewer widow after the screen shot is taken:
Capture to Clipboard: Clicking this option copies the current Report Viewer window to the Windows
clipboard, allowing you to paste (Ctrl V) the image into, for instance, an email or a Word document.
The Ribbon
Access program functions from the toolbar called the Ribbon. By default, the toolbar is minimized. Right-click the grey bar toward
the top of the application window and deselect Minimize the Ribbon:
To hide the ribbon, right-click the grey bar again and click Minimize the Ribbon.
Output the report to a file or send the report via email. If you select Output Report to, the following window opens to
specify file format and path:
Import GAGEtrak reports from other versions of GAGEtrak or other GAGEtrak databases.
This option allows you to send selected data via email in a variety of file types. The output includes sub-forms and
sub-reports. The file format and appearances are the same as those described above for the Output commands.
The Report Browser tab is active by default. This tab shows the most commonly used reports. Access the All Reports tab to view
all reports.
In the Report Browser tab, click on the desired Report Group in the left pane, click the name of the report you’d like to view in the
Report pane and then click OK. The window will display a blank report page and a report filter. The report filter may be minimized
like this:
Click Report Filter and then click the pushpin icon to keep the report filter open.
The report filter allows you to select a specific group of records for the report. There are a few reports, such as the Calibration
Due Listing report, that are time-based; which allow you specify a From and To date range for selected criteria. All reports were
designed using standard Windows True Type fonts.
Quick Filter
The available fields in a Quick Filter vary depending on which report has been selected:
Enter or select the desired criteria by which to filter your report and then click Run Report. The image above shows that a report will
be run for all active digital calipers 0-6.
In the example above, the report will show every gage with a Description that contains the word Caliper that is manufactured by
Starrett.
The asterisk (*) is a wildcard character that indicates, in this example, that you want all gage records that have a description that
includes the word Caliper. If you enter *Caliper, it tells the program that you want all gage records with descriptions ending in
the word Caliper, such as 4-inch Caliper. Likewise, if you enter Caliper*, it tells the program that you want all gage records with
descriptions that begin with the word Caliper, such as Caliper Digital.
Use the Condition fields to select search operators such as >, <, =, etc., to include records that are greater than, less than, equal to
or similar to the value you’ve specified.
After the report appears, you can use the vertical and horizontal scroll bars to view different parts of the report, or use the page
navigation buttons to view multiple pages of the report. Use the Zoom buttons on the menu to view more or less of the report.
GAGEtrak’s report toolbar contains common commands that you can use for reports. Each toolbar button is described below,
pictured from left to right here:
Field/Button Description
Toggle Sidebar Open a side bar showing page thumbnails.
Print Print the report.
Copy Copy the current report as formatted text.
Find Find specific text within the report; clicking Find will open a Find window.
Zoom Buttons Zoom out, zoom in or zoom to a specified percentage.
Fit Width Zoom into the report to fit the width of the window.
Fit Page Zoom out of the report to see a whole page at a time.
Report Descriptions
These tables contain descriptions of the most commonly used reports, including special filtering options.
GAGE REPORTS
Report Description
Gage Detail Report Use this report to see a comprehensive gage report, including record details.
Gage Issue For a complete list of gage issue history, use this report.
History Report
Gage Listing by… Select a report “by” specific report for viewing / printing specific information.
PART REPORTS
Report Description
Gage Requirements by Part This report prints gage requirement sheets.
Part Listing... These reports list parts, including descriptions and uses.
R&R REPORTS
Report Description
R&R Due Listing by… Select a report “by” specific report for viewing / printing specific R&R Due Listing information.
These reports list gages that are due for R&R studies. Reports for each R&R study may be
printed from Gage R&R.
MSA Summary Summary completed MSA studies performed for gages in the GAGEtrak database.
STAFF REPORTS
Report Description
Gage Authorized Users This report lists each staff member and the gages each person is authorized to use.
Gage Staff Issue History Provides a summary of gages issued to staff members (sorted by staff member name.
Gage Staff Issued to List Provides a summary of gages issued to authorized users of gages (issue control mechanism
using staff members and sorted by staff member name).
KITTING REPORTS
Report Description
Kit Listing... Lists all or one specified kit, and its associated Required Gage Types and Required Gage
information.
Kit Entry History Provides a kit issue history summary with gage issue details for each kit listed.
Application Icon
Click the application icon in the upper left corner of the window. This menu contains many of the same functions as Report
Viewer; please see the Program Conventions chapter of this guide for detailed explanations of Open, Output, Export/Import and Help.
Icon Function
Create a new report; click this icon to select the report type and name it:
Open an existing report in order to modify it; clicking this button displays the Report Selector window. Select the
group, select the report and then click OK.
Import GAGEtrak reports from other versions of GAGEtrak or other GAGEtrak databases.
Cut your selection when editing field entries and store that text on the clipboard.
Copy your selection when editing field entries and store that text on the clipboard.
Click this icon to open the SQL Editor and modify the SQL statement of a report.
Select a sub-report and then click this icon in order to edit the field by which the main report and sub-report are
linked, i.e., the parent-child relationship between the two reports.
Select a sub-report and then click this icon; the sub-report will open in a separate tab of Report Editor, allowing for
modifications.
The center portion of the screen is the designer canvas which presents label fields and text fields. A label field appears exactly
as-is when you run the report; a text field pulls data from your database. In the image below, Gage ID: is the label field and
Gage_ID is the text field.
To modify a label field, simply overwrite the contents of that field with your desired label. For example, select the Asset No: label
field:
If after modifying a label field, the change you made is not displaying correctly when you run the report, then that label field’s
contents might be dictated by tables in the database. If that’s the case, you can delete such a label field and create a new one.
After deleting the field, click Label in the Report Toolbar:
Then, in the canvas area, click and drag a rectangle to create your new field. Label the field as desired and then modify the
properties in the in the lower right pane of the Report Designer window, such as font size and color, etc.
You can also delete, add and move fields. In this example, we will remove the Gage SN fields. Select both the label field and the
text field and then either right-click and delete or simply click the Delete icon in the Ribbon .
To simplify your efforts, you can copy and paste existing label/text field groups so that you don’t have to modify each field’s
properties, such as font and alignment.
After copying/pasting, select one of the new text fields; in the lower right pane of the window, locate the DataField row. This row
displays the name of the data source that gets pulled into that field. If, for instance, you copy/paste the Gage ID fields and overwrite
the field contents in the canvas, the DataField area will still show Gage_ID. You would need to modify that value.
Since this particular report already contains Calibration Frequency further down the report, we will delete those fields and move the
remaining fields upward.
Click and drag your mouse over all desired fields and then either drag them into place or use the arrow keys on your keyboard.
Now that we have altered the report, we need to save it. If you click the Save icon, you will overwrite the existing report. If you want
to save your new report with a new name, click the Save As icon; the following window opens, allowing you to name your new
report. Enter the new name and click OK.
Select your newly created report and then click OK. You can specify filter criteria, if you like, or you can simply click the Run Report
button in the filter pane.
Label Viewer
Navigate to Reports -> Label Viewer to see a list of available labels for your gages and parts. To print labels, you must have the
GAGEtrak Calibration Label Kit. See the following chapter for more detailed information.
Note: The label generator in GAGEtrak can generate custom size labels, but not all printers can support custom label sizes so it is
highly recommended to consult your printer guide prior to proceeding.
GAGEtrak 7 User Guide User Guide Chapter Thirteen: Calibration Label Kit 201
Printing Labels from Calibration Entry
You can print individual calibration labels directly from the Calibrations -> Calibration tab:
To print a label, select the desired label from the Select Label Design drop-down list and then click the Print Label button. This will
automatically send the label to the printer. The height of the selected label must match the height of the tape currently installed in
your label printer.
Note: The P-Touch Label Printer ejects and cuts off a strip of blank label material approximately 1” long before printing. This is a
direct result of the design of these label printers. The diagram below illustrates the mechanics of the P-Touch printer.
202 User Guide Chapter Thirteen: Calibration Label Kit GAGEtrak 7 User Guide
At point A in the diagram, the print head transfers ink from the ink strip to the back of the clear laminate. Rollers bond the color
substrate and the clear laminate together at point B. The laminated tape is then fed out until it reaches the cutter at point C.
The cutter is approximately one inch beyond the print head along the path of the tape; therefore, at the beginning of the printing
process, about one inch of blank tape has already advanced past the print head. This problem cannot be eliminated; however, it
can be mitigated by printing labels in batches rather than individually, since the printer will feed a blank strip only at the beginning
of each batch of labels.
To preview a label, click the View Label button. The View Label button will open the report editor, allowing for viewing or editing of
the label prior to printing.
GAGEtrak 7 User Guide User Guide Chapter Thirteen: Calibration Label Kit 203
Click the desired label and a filter window similar to the one below will appear:
You can use this window to filter for a group of calibration labels based on Gage ID, Location, Description, etc. for any calibration
record that exists in the database.
Below are brief descriptions of the fields and buttons in the filter windows; not all fields are available in all filters:
Field/Button Description
From and To Date Inclusive calibration dates.
Done
From and To Time Inclusive calibration times.
Done
By Name of calibrator.
Gage ID ID of specific gage. This will limit your label to one – for the specific gage ID only.
Description Enter a description for the gage.
Current Location The current location of the set of gages to be selected.
Storage Location The storage location of the set of gages to be selected.
Type The type of the set of gages to be selected
Select Label Printer This drop-down list will contain the names of any P-Touch label printer driver(s) installed on your workstation; select
the desired label printer from the list.
View Button To see how your label will appear before you print it, click on this button.
Print Button Prints labels
Clear Filter Button Clears all filter entries
Close Button Aborts label printing and goes back to the Custom Label Menu
Advanced Filter Use this button to open the Advanced Filter window. You can then filter for a group of records that match the
Button criteria you enter. You can also open previously saved criteria for use and create and save new criteria.
Add to Queue Button Add filter file to printing queue. You can view and print the file from the Report Queue
Fill From Queue Copy filter information from a saved file in the Report Queue
Button
When you have finished entering your filter parameters, click View to see a preview of your label. Make sure that the height of the
tape cartridge in your label printer matches the height of the selected label and then click the Print button to print your labels.
204 User Guide Chapter Thirteen: Calibration Label Kit GAGEtrak 7 User Guide
User Guide Chapter Fourteen:
Gage Calibration and Control
This chapter discusses the basics of gage calibration and control; it’s intended for users with limited experience, but it also serves
as a review for more experienced users. A list of references is at the end of this section.
Purpose of Calibration
Gages, test equipment, and measurement standards are all susceptible to deterioration in accuracy during use and storage. To
maintain accuracy in your measurements, you need an ongoing calibration system.
Calibration Terminology
Calibration
Unfortunately, the terminology associated with calibration control is not universally standardized. Typically, the term calibration
means placing a gage, measurement standard or test instrument into a state of accuracy. Calibration is also called re-calibration or
reconditioning.
GAGEtrak 7 User Guide User Guide Chapter Fourteen: Gage Calibration and Control 205
Test Equipment
The term “test equipment” covers a variety of measuring equipment, sometimes including working standards. You use this
equipment to check your products and manufacturing processes. Check test equipment for calibration before you use it, even if
it’s brand new.
Test Materials
This term refers to all consumable standards, such as films or liquids, used in calibrating test equipment. Since variability in these
materials can affect your measurements and calibrations, suppliers often give you data on the test material’s variation.
Calibration Schedules
You usually determine calibration schedules by the gage’s classification. You can establish initial calibration schedules by expected
usage, engineering judgment, and bargaining. As you gather actual calibration information, you might need to adjust the schedules.
The primary intent of a calibration schedule is to detect accuracy deterioration prior to intolerable levels of accuracy. Accuracy
deterioration usually results from gage usage; less often, it results from the passage of time.
• Elapsed calendar time – the most popular method, it establishes a fixed calendar time, such as 90 days, as a check-
ing interval
• Actual amount of usage (time and cycles) – based on counting the number of days (or operating cycles) for which
the gage was used (you can keep this count manually or automatically)
• Actual operating time – an excellent method for electrically driven gages (a device used for measuring actual operat-
ing time is called a “coulometer”)
206 User Guide Chapter Fourteen: Gage Calibration and Control GAGEtrak 7 User Guide
Calibration Practice
To ensure consistency in your calibration techniques, develop procedure manuals of calibration practices. At minimum, include
tolerances for accuracy; standards; temperature and humidity controls (if needed); time cycles; human technique; and other
important factors.
After calibration, make the equipment tamper-proof (if possible) with sealed adjusting screws, lead-sealed lock wires, stamps, and
other devices.
Record the results of your calibration checks and any required adjustments or repairs. At minimum, record the following
information:
Review this information periodically to see if you should reduce checks on stable equipment; increase checks on unstable
equipment; or redesign/replace the measurement equipment.
References
The following books and publications discuss gage calibration and control:
National Conference of Standards Laboratories (NCSL), Establishment and Adjustment of Calibration Intervals (RP-1), Second
Ed., 1989.
GAGEtrak 7 User Guide User Guide Chapter Fourteen: Gage Calibration and Control 207
Resources for Books, Publications, and Reference Materials
American Society for Quality Control (ASQC)
208 User Guide Chapter Fourteen: Gage Calibration and Control GAGEtrak 7 User Guide
Admin Guide Chapter One:
Installation
You can use GAGEtrak on a single workstation, on a network or in a client/server environment; installation will vary slightly for each
of these options. This chapter gives you general installation instructions for all options.
System Requirements
Files
The root directory of the GAGEtrak media contains all the files required to run GAGEtrak.
Installation Options
You can use GAGEtrak as a client/server program, with one centralized, dedicated computer hosting the database and one or more
user workstations accessing the database from that server. You can also choose to install and use GAGEtrak on only one PC (a
single-user setup).
If you have a multi-user license of GAGEtrak, you and your other GAGEtrak users can install the program from the supplied media
or from a network location. If you want your users to install from a network location, copy all of the files in the root directory of the
supplied media to the same network location and then instruct users to run SETUP.EXE from that location.
1. To begin installation, double-click the SETUP.EXE file; the Welcome screen will appear. Please note that the version
number shown in the lower left corner of the window will vary depending on the version you are installing.
Close any other Windows programs that are running and click Next.
3. Now you will choose the location for the program on your hard drive. Since this location is specific to each
workstation, do not select a network location. We recommend using the default directory, C:\ProgramData\
CyberMetrics Corporation\GAGEtrak 7.0. After selection, click Next.
5. In this screen, you can enter a new program group name, though we recommend keeping the default, GAGEtrak 7.0;
click Next.
7. Choose the appropriate type of database connection for GAGEtrak, per the on-screen instructions and then click Next.
9. Back on the GAGEtrak installation screen, successful installation of GAGEtrak will be confirmed; click Finish to exit the
installer.
Please note that Technical Support is not available for the creation of a client/server database.
If Installation Fails
If, for any reason, you can’t install your software or you receive any error messages during installation, try reinstalling. If installation
fails again, please write down any error messages and call Technical Support at 1-800-777-7020 for further instructions.
The install directory can be modified during installation, so a different destination directory may have been selected.
Note: If the Microsoft Access full application version is installed as part of Office Professional Suite, the Runtime will not be
installed for GAGEtrak 7, so the items listed above may not be present for removal.
Once you have deleted the GAGEtrak 7 program group and install directory, as well as the third-party supporting applications,
GAGEtrak 7 will have been completely removed from your computer.
If you are an existing customer who wishes to install one of our regular software updates to your version, you only need to obtain
the new update version setup and install it into your existing GAGEtrak 7 directory.
218 Admin Guide Chapter Two: Data Utility GAGEtrak 7 User Guide
New Sample Database
To create a new database in either MS Access or SQL Server that contains sample records, click the New Sample Database radio
button and then click Next. Follow the on-screen instructions.
GAGEtrak 7 User Guide Admin Guide Chapter Two: Data Utility 219
Upgrade Database
To migrate data from GAGEtrak version 6.0 or greater, click the Upgrade Database radio button and then click Next. Follow the
on-screen instructions.
220 Admin Guide Chapter Two: Data Utility GAGEtrak 7 User Guide
Update / Add Reports
To update GAGEtrak standard reports or to replace damaged reports, click the Update/Add Reports radio button and then click
Next. Follow the on-screen instructions. Please note that this utility will not backup copies of custom reports or modified standard
reports.
GAGEtrak 7 User Guide Admin Guide Chapter Two: Data Utility 221
Admin Guide Chapter Three:
Setting Up GAGEtrak
Before you begin entering records, we recommend that you configure your GAGEtrak program. From the main menu, navigate to
Setup -> Settings.
Settings
Field/Button Description
Company Enter your company information. The two lines for your company name and logo will appear at the top of all reports.
Information
222 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Paste Logo and To enter your company logo, use the Insert Object or Paste Logo buttons.
Insert Object
Use Insert Object if you already have a logo file or want to create the logo in a graphics program and link it to GAGEtrak.
Use the Paste button if you’ve copied the logo to Windows Clipboard.
Try to insert a logo graphic about the same size as the logo region shown; 400x180 pixels. To avoid wasting memory,
don’t use a logo with more colors than your printer can print.
You can use a scanner to obtain your logo, but scanners are often set for more resolution or colors than your printer
can support. A logo created this way becomes a huge file that uses an excessive amount of memory. To conserve
memory, paste your logo into GAGEtrak as a .BMP file, even if you created it in a graphics program. Pasting your logo
as a bitmap image uses less memory. If you can view your logo in the Settings window, but it doesn’t appear on your
reports, you don’t have enough memory for the logo size (in bytes) that you’ve used.
Tip: Generation of reports that contain a company logo will generate more efficiently if the logo size is within the 1KB
range.
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 223
The table below describes the fields on this form:
Field/Button Description
Dashboard Due The Dashboard Due List shows gage IDs that are due or past due (if you check the Include Past Due checkbox). Set
List your preferred number of days for GAGEtrak to display in the list.
Start Frequency This field sets the start date of the Dashboard Due List. The start day will be calculated to before the current date using
this frequency. So, if this frequency is 7 days and the current date is 10/8/2013, then the start date will be 10/1/2013.
Usually this will be 0 Days, since you want to show all the calibrations due starting from today.
End Frequency This field sets the end date of the Dashboard Due List. If you want to know what calibrations are due for the next
month, select 1 Month.
Include Past Due Check this checkbox if you want to show calibrations that are past due. This will show every calibration due until the
end frequency.
Change Gage When a gage is attached to a Service Request, the application can automatically change that gage’s Status ID based on
Status when the Type selection for the Service Request. Choose Do Not Change to prevent such changes, Automatically Change to
Gage is sent have the change made without user intervention, and Ask To Change to ask the user if such a change should be made.
Change Gage When a gage attached to a Service Request has been returned from the Service Supplier and its Gage Service Request
Status when Status is set to Closed, the application can set the status of that gage back to Active. This change will also be done if
Gage is Returned the Status for the entire Service Request is set to Closed.
Automatically The application has the ability to read ambient temperature and humidity from a variety of USB sensors (like the
Read GAGEtrak CyberSensor) and enter that information into a Calibration record. Check this box to have the application
Temperature and automatically read these values when a Calibration is passed. The user can also manually read these values from the
Humidity From sensor by double-clicking in the appropriate field in Calibrations.
Sensor
Read Use this option to tell the application if the temperature reading for the USB sensor will be read in degrees Celsius or
Temperature In: degrees Fahrenheit. This setting applies to the automatic and manual temperature readings.
Sensor Serial Entering the Sensor Serial Number is optional. If you have more than one CyberSensor and you want to make sure that
Number you always use the same one at a particular PC, you can enter the serial number and then check the Confirm Sensor
and Serial Number before taking reading checkbox. This confirms that the serial number of the CyberSensor currently
attached to the PC matches the serial number entered here.
Confirm Sensor
Serial Number
before taking
reading
Temperature Enter sensor correction values, if necessary. For instance, if you enter 2 in the Temperature Correction field, when the
Correction CyberSensor takes a reading it will add 2 degrees to the current reading.
and
Humidity
Correction
Copy Gage notes Check this checkbox to have the program copy the contents of the Gages -> Information tab -> Notes field to the Notes
when issuing field in the Issue Gages screen. This may be useful if, for example, you have special instructions in the gage record
notes on the use of the gage or info about issue restrictions, etc.
224 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Settings – Cal. Options Tab
Field/Button Description
A1 Adjusting Method A1 usually changes the calibration frequency every time you calibrate, even after the calibration frequency
Calibration has achieved high end-of-period reliability. Most users will prefer less frequent changes and may not want the short
Frequency calibration intervals that go with high reliability. Method A1 is included for users who are familiar with it and wish to
Setting continue using it.
If you select Method A1 in the Gages -> Schedule tab for any gage, whenever you enter a new calibration record for
it, GAGEtrak automatically adjusts its calibration frequency according to the rules you define in the Gage Frequency
Adjusting Interval table.
This table is preset to use the NCSL RP-1 Method A1. This method increases the existing calibration frequency by 10%
if the as-found condition of the gage is in tolerance (multiplied by 1.1). If the as-found condition of the gage is out of
tolerance, then it reduces the interval by 55% of the existing frequency (multiplied by .45). If the gage is new and you’ve
never calibrated it, then the interval remains the same (multiplied by 1).
Simulation studies show that you achieve measurement reliability target of 95% EOP using this approach. “EOP” stands
for “End Of Period” – it refers to the reliability of a gage at the end of its calibration interval. You can change the table to
use different factors if you need to use another frequency adjustment method.
Example: If the frequency is 30 days and the as-found condition before calibration is in tolerance, then the frequency
would be set to 33 days (1.1 x 30 = 33 days). If the as-found condition was out of tolerance, the frequency would be
automatically reduced to 13.5 days (.45 x 30 = 13.5 days).
A3 Adjusting Method A3 lets you specify a Reliability Target and requires a certain amount of statistical confidence before deciding
Calibration that a change is necessary. Method A3 tends to eliminate unnecessary changes. When a change is found to be
Frequency necessary, method A3 uses formulas that optimize the Calibration Frequency in fewer steps than Method A1.
Setting
Method A3’s recommendation is available even for gages that do not have Method A3 selected (in the Gages ->
Schedule tab). To see these recommendations, click on Gage Frequency Adjusting Interval in Calibration Utilities.
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 225
Reliability Target This is the desired end-of-period reliability, for example: the desired probability that the as-found condition of the gage
will be in tolerance at the end of the calibration period (after the optimum calibration frequency has been achieved).
GAGEtrak will recommend changes to the calibration frequency until the specified reliability is obtained. The default
Reliability Target is 80%, but you can change it. Specifying higher reliability will result in more frequent calibration.
Significance This is the maximum amount of risk GAGEtrak will take in recommending a change, i.e., the risk that a recommended
Threshold change will turn out not to have been necessary. The default is 0.3. Specifying lower significance will increase the
number of calibrations required to make a decision. Significance must be between 0 (never change) and 1 (always
change).
Maintain Checking this will enable Procedure History to be recorded. In a Standard installation, this will be unchecked by default.
Calibration For a 21 CFR install, this will be checked and locked.
Procedure
History
Print Issue Label Default print label selection for label issuance.
When Issuing
Gage
Certificate of This statement is included in the Certificate of Calibration document. This field scrolls up and down to allow for longer
Calibration statements.
Statement
Failure Notice This statement is included in the Calibration Failure Notice document. This field scrolls up and down to allow for longer
Statement statements.
Default Select a default calibration label.
Calibration Label
Calibration ( ) Before, After, and Comments
Measurement
[Tab] key or [Enter] key goes to each of these three fields for each measurement.
Tab Stop
Behavior
( ) Before and After
[Tab] key or [Enter] key goes to Before and After fields for each measurement.
( ) Selected Control
[Tab] key or [Enter] key goes to one field of your choice in the Calibration Measurements window. To use this option
when you are calibrating a gage, place your cursor in the field of your choice, for example, Before. The [Tab] key or
[Enter] key will go to the Before field for the next measurement. If, instead, you place your cursor into the After field,
the [Tab] key or [Enter] key will go to the After field for the next measurement. This option is useful when only one
measurement for the standard is required. Some tools or items are adjustable and can be calibrated to a different
measurement; these tools would have different Before and After measurements.
226 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Settings – Calendar Tab
Field/Button Description
Skip Dates GAGEtrak lets you define dates that you want skipped when it calculates calibration due dates. These days, called skip
and Skip Date dates or skip days, might include holidays, vacation periods or plant shutdown periods. Enter as many skip dates as
Direction necessary. To delete a skip date, click on the record selector box (on the left of each date) and click the Delete icon in
the toolbar. To skip days of the week (like weekends), check the box next to each day of the week you want to skip.
If a calculated calibration due date falls on a skip date, GAGEtrak schedules it on the following day or the previous day,
depending on the Skip Forward and Skip Backward set for each gage. Select Skip Forward or Skip Backward in this
window to set the default. If you manually enter a calibration due date, GAGEtrak won’t apply your skip dates to it.
Calendar Color- Four different colors are used to display the number of hours shown on the Calibration Calendar. You can set the hour
Coding Intervals duration range for each color according to the staffing level available on a daily basis. The colors on the calendar will
show at a glance which days are overstaffed or understaffed.
Calendar Range Enter the number of months into the future for the calendar to display. If you want to put large numbers here,
experiment with them. The larger the number of months, the longer it will take to calculate next due dates and generate
the Calibration Calendar. For faster operation, you may want to set the Calendar Range from 3-6 months.
Calendar Refresh Use this field to modify the interval at which GAGEtrak automatically updates the calibration data shown in the
Rate calibration schedule calendar. Refreshing the calendar ensures that the data accurately reflects current data in the
database; you may wish to modify the refresh rate according to how busy your calibration lab is.
Select Start of The day of week selected will dictate how the calendar is presented to the user, for example select Monday as the start
Week of the week, and then double click in a date field. You’ll notice the day of the week begins with Monday and ends with
Sunday in the Choose a Date popup calendar.
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 227
Date Formats
GAGEtrak supports all of the available numeric date formats within Windows. For example, you can represent the date of November
1, 2008 as 11/1/08, 11/01/08, 11/1/2008, 08/11/1, 08/1/11, or 2008/11/1. Because GAGEtrak’s reports use only numeric dates,
you can select only numeric date formats. Therefore, you can’t use dates like “November 1, 2008” or “1 November 2008.”
As a precaution, you may want to verify your date settings in Windows Control Panel. Click the Windows Start button and then
select Control Panel. Run the Regional and Language Options. In the Regional Options tab, click the Customize button. The
Customize Regional Options window will open. The date formats that you enter into GAGEtrak must match the Windows date
setting; otherwise, errors will occur while you’re running the program.
The FDA Edition of GAGEtrak permanently enables its security, advanced audit trail and electronic signature features. Therefore, if
you have installed the FDA Edition, the Enable Security, Audit Trail and Electronic Signature fields show at all times that these
options are active. These fields are grayed out and cannot be changed.
Field/Button Description
Enable Security Check this box if you want to use system security with GAGEtrak. If you have installed the FDA Edition of GAGEtrak,
security is automatically permanently enabled; this option is grayed out to show that you cannot change it.
If Enable Security is checked under a Standard Installation of the application, you will be required to create at least
one Admin user prior to enabling this feature. You can create user security groups and assign group permissions in the
Security utility.
Enable Security If you check this box, GAGEtrak will display warning messages if users try to perform actions, such as deleting records,
Messages for which they do not have permissions. If you leave this box unchecked, users won’t see messages, but will still be
unable to do anything they don’t have permission to do.
228 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Logon Method GAGEtrak allows you to choose from two types of system security:
Windows Logon–uses security from your Windows operating system; when users login to Windows, they can access
GAGEtrak
Application Logon–uses security specific to the GAGEtrak program; you must set up user IDs and passwords in
Security.
Require Check this checkbox to require users to change their logon passwords at intervals chosen by the administrator. When
Password this option is selected, you may select any Number of Days Before Password Change. The default interval is 14 days.
Changes
Minimum Enter the minimum number of characters GAGEtrak will allow for user-defined passwords.
Password Length
User Login Enter the number of minutes of inactivity GAGEtrak will allow before automatically logging out a user. This feature is only
Timeout Period available if Enable Security is activated.
Note: When the time period is changed, you will have to restart the program before the change in duration of inactivity
period will take effect. When the time has been exceeded and there has been no activity in the current session, the
user will be prompted to log back into the application. For an FDA Edition installation, only a non-zero whole number
can be entered for the User Login Timeout Period. For a Standard Installation, a zero value can be entered to disable
the login prompt, but still maintaining security.
Email the ff. Enter a list of e-mail addresses (separated by semicolons) that will receive an automatic e-mail notification when the
recipients… number of Unsuccessful Login Attempts has been reached.
Restrict Issue To If the Restricted Issue To Authorized Users checkbox is checked, the application will control the persons authorized to
Authorized Users Issue gages.
If the Gages -> Auth. Persons and Events tab -> Restrict Issue field is blank or if Program Default is selected, the
application will check whether or not Restrict Issue to Authorized Users is checked in Settings (installation default for
this feature is unchecked).
If Restrict Issue to Authorized Users is checked, the Issued To field in Issue Gages will list only the authorized persons
that were entered on the Gages -> Auth. Persons and Events tab for that gage.
If Restrict Issue to Authorized Users is not checked, all staff will be listed in the Issue To in Issue Gages form.
Enable Audit Trail GAGEtrak will record all actions made within the program, such as record modifications and deletions. The Basic Audit
Trail lists basic user and action information. The Advanced Audit Trail lists basic user, action and Old and New Value
information. To view the Audit Log, navigate to Data Utilities -> Audit Log.
The Advance Audit Trail is automatically and permanently enabled if you have installed the FDA Edition of GAGEtrak.
Remove Audit Enter how many days’ worth of audit trail records you want to keep. GAGEtrak will automatically delete actions
Trail records after older than this value. For example, enter 7 to keep a week’s worth of Audit Trail data. Enter 0 if you want to keep a
this many days comprehensive audit trail record.
If you have installed the FDA Edition of GAGEtrak, all audit trail records are retained permanently; in this case this
option is grayed out to show that you cannot change it.
Electronic Check this checkbox to require users to log in before signing any record.
Signature Login
If you have installed the FDA Edition of GAGEtrak, electronic signatures are automatically permanently enabled; this
option is grayed out to show that you cannot change it.
Do Not Archive The selection of these options dictates how calibrations are to be archived.
Unsigned or
If the Do Not Archive Unsigned Calibration checkbox is NOT checked, then the Do Not Archive Unapproved Calibration
Unapproved
checkbox should not be checked. You can, however, just archive unsigned calibrations.
Calibration
Likewise, if the Do Not Archive Unapproved Calibration checkbox is checked, the Do Not Archive Unsigned Calibration
checkbox should be checked; an approved calibration can only be archived if the Calibrated By and Approved By
Signatures have been created for that calibration entry.
Make this This button will only appear if you have installed the FDA Edition of GAGEtrak over the Standard Edition and are
database an FDA connected to a Standard database. In this case, use this function to convert your Standard database to an FDA-
database compliant database (enabling FDA-compliant features in the program).
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 229
Settings – Automatic Numbering Tab
GAGEtrak can automatically generate a number sequence for your Calibration Certificates, Service Requests, Gage IDs, Calibration
Scan File Names and Gage Numbering Schemes for cloning records. Use this screen to set the desired format.
Field/Button Description
Format The format that will be used to create numbers for new records. Use ‘?’ for incremental letters; ‘#’ for incremental digits;
enter text in all capitals. Leave field blank to use the default.
Last Number This field contains the last number issued. You can modify this number but be sure you enter the values correctly or
Issued there may be duplicates.
Test Select this button to view next formatted number of the sequence.
File Path Select the drill down button to the right of the file path field to access the Browse For Folder dialog box to select
location for stored files.
Numbering Allows for custom numbering conventions for Number Fields and Request Types. If the numbering format does not fall
Schemes within the numbering convention in Numbering Schemes it will default to the format defined in Settings -> Automatic
Numbering.
The Number Fields and the Calibration Type drop-down lists contain predefined lists of fields that can be affected by
the defined criteria in the Numbering Schemes section.
Enable Automatic If this checkbox were checked, then the automatic numbering of new gage records would proceed exactly as it does
Gage Numbering in the current build. If the checkbox were unchecked, then all automatic numbering of new gages would be disabled.
This would include gage numbering by the gage type and the basic gage numbering as defined to the left of this form.
Typical functionality for Calibration Certificate and Service Request Numbering.
230 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Settings – Interface Tab
Use the Interface tab to customize GAGEtrak to use terminology your company prefers.
Field/Button Description
Field Name This is the default text used to describe the field in GAGEtrak.
Label Text Enter your preferred label for the field.
Default Label If a field is to have a value at all times, this is the value to which the system will default.
Text
Normal or Bold The weight appearance of the font.
Report Label Select Open Normally to show the user-defined label text and use Open with Default Label Text to show the default
Options label text.
The field names are in alphabetical order. Scroll down the list to find the field name you want to change. If, for example, you
wanted to make the Model No. field say Tool No., you would replace Model No. with Tool No. in the Label Text area. When you
change a field name here, it will be changed on all entry screens, filters and reports.
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 231
Gage Custom Sub-tab
The Gage Custom sub-tab allows you to customize the types and names of the user-defined fields in the Gages -> User Def and
Attachments tab.
Field/Button Description
Tab Caption In Gages, the tab currently titled User Defined can be edited to reflect a client specific title, for example Characteristics.
Item Item number that corresponds with the User 1-20 label.
Field Type Use the drop-down list to select Text, Date or List (the default is Text).
If you select Date, the customized field will show a pop-up calendar and will only accept dates in the proper format.
If you select List, the following form will appear:
To build your list from scratch, click the Custom List radio button, enter the list values separated by colons (i.e.,
Type01;Type02;Type03) and then close the form.
To use a list that already exists in the program, click the From Table radio button, select the table and field in which the
list exists and then close the form. Use the Add Items to list field to enter additional list items.
Field Attribute Click the […] button to the right of the Field Attribute to update custom lists.
Label Text Enter a custom field name.
Default Label The text that will appear on the form if no modifications were made to the label.
Text
Normal or Bold The font weight of the field label.
232 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Calibration Custom Sub-tab
The Calibration Custom sub-tab allows you to customize the types and names of the user-defined fields in the Calibrations -> User
Def and Attachments tab. See the section about the Gage Custom sub-tab for instructions on how to alter these fields.
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 233
The table below describes the fields on this form:
Field/Button Description
Form Name Use the Form Name drop-down list to select a record entry point; the Tab Name and Tab Caption fields will be
populated appropriately, depending on your Form Name selection.
Tab Name This is the default name of the tab.
Tab Caption Enter the custom name as you want it to appear in the program.
234 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Menu Bar Sub-tab
The Menu Bar sub-tab is for customers who have upgraded from previous versions of GAGEtrak; it is not for use in GAGEtrak 7.
Messages Sub-tab
This tab is used to customize GAGEtrak’s program messages.
Field/Button Description
Message Text Input text to collectively explain the need for the message.
Message Title Select a simple title that explains at a glance what the message is, for example: “Cannot open file,” briefly expresses the
message, “Unable to View/Print the selected File. Please make sure that the file exist or is not corrupt.”
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 235
Setup – Security
Within Security, you can assign rights to the program for each user. Each user belongs to one or more groups and inherits the
security rights of the group(s). Begin by creating users.
Field/Button Description
User ID Select the user you wish to view or enter a new user name. User IDs cannot be duplicated; even if an ID has been
retired, it cannot be reused.
Name Full name of the user.
Open Form From the drop-down list, select the form that you want this user to see when the application starts.
Add Button After entering a User ID and Name, click the Add button to complete the addition of the user.
Delete Button Select a user from the User ID drop-down list and click the Delete button to delete the user.
Note: If you installed the 21 CFR 11 version of the program and the Default account with Administrative rights is
deleted, a new Default User will be created upon re-login. If you installed the Standard version of the program and
Enable Security was enabled after an Admin user was added and then deleted, the application will automatically open
without login restrictions and Enable Security will still be activated.
Password Button Click this button to add or change the selected user’s password.
All Groups List When a User ID is entered in the User ID field, all available group names are shown in the All Groups pane. Click on the
Box name of the group to which the new user should belong and then click the Add>> button; the group to which the user
belongs will then appear in the Member Of pane.
Add>> Button Select the group (to which the user should belong) from the All Groups list and click this button; the group will appear
in the Member Of pane.
Remove<< If a user should no longer be part of a particular group, select that group name from the Member Of pane and click the
Button Remove<< button. This removes the user from this group.
Members Of List The group(s) to which the user belongs will appear in this pane.
Box
236 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Security – Groups Tab
Add or remove user groups and group members using this screen.
It is easiest to set up security on the group level. GAGEtrak has five default groups: Admin, Calibration, Guest, Issue and User (you
can add more groups as needed). When you add a new group, you can copy the permissions from an existing group and then go
to the Group Permissions tab for the new group and make necessary permissions changes.
Field/Button Description
Group From the drop-down list, select the group view or enter a new group name and click Add.
Add Button After entering a new group name in the Groups field, click the Add button to create the group.
Delete Button To delete a group, select the group from the Group drop-down list and then click the Delete button.
All Users Pane Any user added in the Security -> Users tab will be listed in this pane.
Add>> Button Select a user from the All Users pane and click the Add>> button; this displays the user in the Group Members pane,
making that user a member of the selected group.
Remove<< Select a group member or members from the Group Members field and click the Remove<< button to remove the
Button selected groups from the list box.
Group Members Once a group name is selected from the Group drop-down list or entered into the Group field, this pane will display all
Pane of the users assigned to that group.
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 237
Security – Group Permissions Tab
In this screen, modify group permissions to the different forms and reports of the program.
Field/Button Description
Group Select the group for which you want to establish permissions.
Select Object Select the type of object for which you want to set permissions. If you select Form Control (which is a field within a
form), you will have to select a form and select the control (a Select Control field will appear).
Select Form, Depending on what you select in the Select Object pane, one or more drop-down lists will be displayed to the right of
Select Report, that pane; you will need to make selections from each of the displayed lists.
Select Control
Suppose you want to hide the Cost field in the Gage -> Information tab from the Calibration group. You would select
and Select
Calibration from the Group drop-down list. Then, in the Select Object pane, click the Form Control radio button; two
Function
fields appear to the right: Select Form and Select Control. In Select Form, choose Calibration Entry. In Select Control,
choose Cost. In the Permissions pane, click the No Access radio button. This hides the Cost field from every member
of the Calibration group.
Permissions Select the permission to be assigned to the object. Available permissions will vary depending on the selection made in
the Select Object pane.
238 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Security – Object Permissions Tab
This form is used to view a comprehensive list of objects and permissions for a selected form, report, control or function.
Field/Button Description
Select Object Select the type of object for which you would like to view permissions.
Select Form, Depending on the selection made in the Select Object pane, a field will appear to the right of that pane.
Select Report,
For example, selecting Form will require you to select a form from the drop-down list. When the form is selected, a
Select Report
comprehensive list of all Control Names and Types, Groups and Permissions are available for viewing in the lower
Control and
portion of the form.
Select Function
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 239
Setup – Setup CA/Service Request
To set up service request letters or corrective action request notices, Navigate to Setup -> Setup CA/Service Request. This form
contains pre-defined letters and allows for the addition of new letters. To enter a new letter, click the new record button and enter
the necessary information.
Field/Button Description
Letter Type Name of the letter (must be unique name).
Date Authored Date letter was written.
Authored by Name of person who developed the letter.
Body Body of the letter.
Open Editor Click this button to open the letter contents in the .RTF editor. This editor supports rich text; therefore, text defined in
another word editor such as MS Word can be copied and pasted into this editor.
Gage Status Make a selection from the drop-down list to change the status of a gage when the letter is generated; for instance,
when sent when a Calibration Request is sent, the Status of the gage could be changed to Out for Calibration.
Gage Status Make a selection from the drop-down list to change the status of a gage when the request has been completed; for
when returned instance, when a gage is returned from a passed calibration, the Status of the gage could be changed to Active.
240 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Setup – Gage Events
Use this screen to define triggers and actions for various changes made to records, such as the passing of a calibration or the
deletion of a gage record.
When an event is triggered, an action can be performed such as running an external application like opening up a Microsoft Word
document or initiating the transmission of an email.
Note: As a user, you can add additional Gage Events that will be triggered by one of the available selections listed under Trigger.
The Trigger list is predefined and is non-editable, as are Actions.
Field/Button Description
Event This field displays the title of the event. Events are also listed in the Event drop-down list of the Gages -> Auth. Persons
and Events tab.
Trigger What causes the action to initiate?
Description A more descriptive version of the Trigger.
Action This is the action that will be taken when the Trigger occurs.
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 241
Setup – Auto Email Header
The Auto Email Header function allows plain text emails to be sent automatically from the program based on the Email Event. The
Email Event list is predefined and entries cannot be added to or deleted.
Field/Button Description
Email Event Select the event you would like to modify. The predefined email events are:
• Gage Issued Out – when a gage is being issued from within Gage Entry -> Issue / Return or the Issue Gages
form.
• Gage Returned – when a gage is being returned from within Gage Entry -> Issue / Return or the Return Gages
form.
• Automatic Calibration Due Listing – automatically sends an email when the application is opened. The list of
calibrations due is based on the filter criteria created on the automatic calibration due listing report.
• Cal Due Listing – will be sent from the Calibration Due report.
• Gage Added to Service Request – will be sent when a gage is added in Service Request Entry.
• Gage Status Closed – sends when a gage status is changed to Closed in Service Request Entry.
• Service Request Closed – will be sent when the Service Request Status has been changed to Closed in
Service Request Entry.
• Calibration Passed – is generated when the checkbox in Calibration Entry is checked.
• Gage Limited – will send when the Calibration Status in Calibration Entry is set to Limited.
• As Found Condition Out – will send when the As Found Condition in Calibration Entry is set to Out.
• Calibration Status Change – will send when the Calibration Status in Calibration Entry is set to anything other
than Passed.
242 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Email Selection The following selection will provide the following results:
• Send List / Send Issued To – when selected, a list of all gages that have a due date on or before the current
date will be created and included in the email body.
• Send List: will send list of due gages to the employees selected under Employee ID column.
• Send Issued To: if any of the gages on the list is currently issued, a notification will be sent to the Issued To
person.
• Send Auth. Persons – an email will be sent to the list of people in the Gage Entry -> Auth. Persons form, if the
Restrict Issue is set to either Not Restricted or Program Default.
• Send Gage Info After Email Body – if selected, the Email Text will display at the beginning of the body of the
email followed by the list of gages.
Email Text Content included in the body of the email transmission.
Employee ID Select personnel from the drop-down list as recipients of the email transmission.
If the user would prefer Days to display as No. of Days, this is the module that will allow you to make that revision. Simply overwrite
the existing text with your preferred text:
Changing the text does not affect how the program uses this field. It merely changes what the user sees on the screen and any
changes made to the text fields will appear throughout the program.
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 243
The table below describes the fields on this form:
Field/Button Description
Combination Name This is the name of the field that contains the editable drop-down list.
Item This is the text that is currently displayed; overwrite this text with your preference
Active Checkbox If this checkbox is checked, that item is currently available for selection in the specified drop-down list. Uncheck
the Active checkbox to disallow that item’s future selection.
AddItemBehaviour This option is not available for all drop-down lists. This field lets the Administrator determine the way in which
users may add new items to a drop-down list.
• Automatically add means that the user can type any value into a field that contains a drop-down list and
that value will be added to the list for future selection by other users.
• Cannot add items means that users may not enter new data; they may only select from the items already
in the list.
• Ask to add means that the user may enter new text into a field that contains a list and the program will
ask for confirmation of the addition of the item.
If a value list contains unwanted data, such as Supplier Code, you can navigate to Supplier Entry and uncheck the Enabled checkbox.
This makes the supplier inactive which removes the supplier from the Supplier Code drop-down list for future gage entries.
Select this utility to enter the descriptions you want to appear in the Status drop-down list in Gages. Click the Include in lists of due
gages checkbox to include all gages of that status in reports and on the dashboard.
The default descriptions are Active, In-Active, Out for Repair, In Calibration and Lost. You can change these descriptions or add
additional ones as required by your company; for example, you may need to add Retired, Sealed or Loaned Out.
244 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Setup – Report Control IDs
If your company must follow Document Identification and Control requirements, you can identify each GAGEtrak report with a
unique document control number. To set up this feature, navigate to Setup -> Report Control IDs and enter a new record or edit the
existing entries. The Control Text that you enter will appear at the bottom of reports.
Tip: If your company does not require a form number on reports, you can use this area for your company’s address and telephone
numbers.
GAGEtrak 7 User Guide Admin Guide Chapter Three: Setting Up GAGEtrak 245
The Create/Edit Report tab displays a list of all available labels. The Delete Report tab will show a list of deleted labels; only labels
that you create or import can be deleted; the default labels shown here cannot.
Use the Import/Export tab to import labels received from Technical Support or other GAGEtrak users or to export to other
GAGEtrak users.
246 Admin Guide Chapter Three: Setting Up GAGEtrak GAGEtrak 7 User Guide
Admin Guide Chapter Four:
Staff Records
From the Main Records menu, select Staff to enter and view detailed employee records for your staff, including information like
training, ID photo, what gages they’re authorized to use and whether a gage has been issued to them.
The following table explains each of the fields and buttons in this screen:
Field/Button Description
Employee ID Enter a unique alphanumeric identifier for each employee.
Name In this field, enter the employee’s full name.
Active Check this box to show that the employee is currently active. If you don’t mark the employee as active, his or her name
won’t appear on reports that list available employees.
Address, City, Enter the employee’s full address.
State and Zip
E-Mail Enter the employee’s e-mail address.
Home/Pager and Enter the employee’s phone numbers.
Work Phone/Ext.
GAGEtrak 7 User Guide Admin Guide Chapter Four: Staff Records 247
Emergency Enter a person’s name and phone number to contact in case of emergency.
Contact Name
and Phone
Craft Use this field to categorize your workers by profession. You can use a description, such as welder or electrical engineer;
a code, like MIG-3; or a union number combined with a classification, such as 786-Journeyman or 786-Apprentice.
Rate Enter the employee’s hourly rate.
Seniority Enter the seniority or other work status of the employee. You could use this field to store the date that determines
seniority.
Skill Level Using either an internal or external classification system, assign a skill level to each employee. You could also use this
field to indicate multiple skills for your employees, assigning letters or numbers for different skills.
SS No. Enter the employee’s social security number.
Job Title Enter the employee’s official job title.
DOB Enter the employee’s date of birth.
Date Hired and Enter the date on which you hired the employee and the date on which the employee started his or her current position.
Date in Job
Department Enter the primary department in which the employee works.
Supervisor Enter the name of the employee’s direct supervisor.
Shift Indicate the shift(s) for which this employee is available.
Crew Use this field to track the name of the crew(s) to which this employee either belongs or is qualified to belong.
Staff User 1 and Use these two fields to store any additional employee related information.
Staff User 2
Field/Button Description
Education Give a basic description of the employee’s education; for example, BS – Mechanical Engineering.
Industry Experience Enter the employee’s work experience; for example, 6 years Inspection Technician, Grade II.
Related Experience Use this field to track any other useful experience, such as AutoCAD 3-dimensional wire diagramming.
Management Experience Enter any management experience that the employee has; for example, Supervised Calibration Inspection
Dept. in 2008.
248 Admin Guide Chapter Four: Staff Records GAGEtrak 7 User Guide
Training History
In this section, you can track classes or certifications that each employee has completed. Use the scroll bar at the bottom of the
screen to see the different fields.
Field/Button Description
Description Enter a brief description of the training.
Start/End Dates Beginning and end dates of the training.
School Enter the name of the school at which the employee attended training.
Cost Enter the cost of the class.
Status Use this field to indicate whether or not the employee has finished this particular class.
Certification If this training was for a particular certification, enter the type of certificate.
Cert. Expiration If the certification is good for only a specified length of time, enter the expiration date in this field.
Date
Hours Enter how many hours the training was worth or how long it lasted.
CEUs CEUs are Continuing Education Units. In this field, enter the number of credit units earned for the training.
Comments Enter any other relevant information for this training or certification.
GAGEtrak 7 User Guide Admin Guide Chapter Four: Staff Records 249
Staff – Authorized Gages Tab
In this screen, enter a list of gages that the employee is authorized to use; use the Gage ID drop-down list to select a gage. Once a
selection is made, the Description, Type and Model No. fields will automatically populate with information from the gage record.
The Note field can be used to document special instructions, etc.
250 Admin Guide Chapter Four: Staff Records GAGEtrak 7 User Guide
Admin Guide Chapter Five:
Database Utilities
In addition to setup features, the Database Utilities menu also contain functions that help you maintain your program and
database. In this chapter, we’ll discuss these utilities, including archiving or un-archiving records, backing up your data and
exporting or importing records.
Archive/Un-archive
Important: Always make a backup copy of your database file before you archive.
Use the Archive/Un-archive utility to archive or un-archive your calibration and gage issue records. Archive moves your records
from the current group and puts them in a storage location within the database. This makes your current group of records smaller
and your database faster. An archive is not the same as a backup.
When you select this feature, the following filter will appear:
You can archive your calibration or gage issue records by Gage ID or by From Date and To Date. To archive by date, enter the
beginning date in the From Date field and the ending date in the To Date field.
GAGEtrak 7 User Guide Admin Guide Chapter Five: Database Utilities 251
When all criteria have been entered, you can view the records first by clicking the View Records button (or the View Cal Meas
button) or you can immediately archive them by clicking the Archive button. After archival, you can still click the View Records
button to view the archived records:
To put archived records back into the current record group, set up the criteria in this screen and click the Un-Archive button.
In the Setup -> Settings -> Security tab, you can disallow the archival of unsigned and/or unapproved calibrations.
Audit Log
Select Audit Log from the Database Utilities menu to view a detailed log of all changes made to the database. Place your cursor in
any row and the details (before and after values, etc.) for that row will be displayed at the bottom of the form:
There are two ways to enable the Audit Trail in order to view the Audit Log:
1. If the FDA Edition of GAGEtrak was installed, security and the Advanced Audit Log are automatically and permanently
enabled and the audit log records are retained indefinitely.
252 Admin Guide Chapter Five: Database Utilities GAGEtrak 7 User Guide
2. In the standard version of GAGEtrak, you would need to enable the Audit Trail in the Setup -> Settings -> Security tab.
Here, you can select your preference for audit trail tracking: Advanced Audit Log, Basic Audit Log or No Audit Log. If
No Audit Log is selected in the Enable Audit Trail field, attempting to open Audit Log from the Database Utilities menu
will display a message stating so. Click OK on the message and the Advanced Audit Log form will be displayed for your
reference, but the system will NOT be tracking any records until an audit trail has been selected.
Backup/Restore
Navigate to Database Utilities and select Backup/Restore.
You should periodically back up your database file (we suggest that you do so every day). We recommend that you use GAGEtrak’s
built-in Backup/Restore function for this task; however, if you have a specialized backup product (such as Colorado Backup, Zip
Drive or another network backup utility), you can use that product instead.
GAGEtrak’s Backup/Restore utility works only with MS Access databases. If you are using MS SQL, you must use backup and
restore utilities designed for SQL. See your system administrator, as these are not included with GAGEtrak.
GAGEtrak 7 User Guide Admin Guide Chapter Five: Database Utilities 253
Manual Backup
Choose Manual Backup if you wish to specify the name of your backup file or to back up a database other than the one you are
currently using. To start the backup procedure, click the Manual Backup button.
You will be prompted to choose a name for the zip file. Select the drive and enter a name for the backup ZIP file. For example, if
you’re saving a backup file on March 17, 2015, you could name it Backup03172015.ZIP.
In the next window, browse to and select the database file that you want to back up and then click the Open button.
If your database is on your server, you must change the drive letter to your network drive and select the appropriate folders, then
highlight the database file. If you aren’t sure where your database is located, see Change Database -> Current Connection. If you
use more than one database with GAGEtrak, back up each one of your databases separately.
When the backup is finished, you will receive a confirmation message saying that the operation was completed successfully.
The resulting backup file is compressed in the industry standard ZIP format. This means that you can use other utilities, such as
PKZIP, PC-Tools, WinZip or Norton to restore your backup file.
Manual Restore
When you restore your database, restore it to a location different from that of your current database. The Restore utility contains
a safeguard that prevents you from overwriting your current database, even if you try to do so. This safeguard lets you alternately
open your restored and current databases to compare them in case you suspect that you’ve lost data because of a corrupt
database. We recommend creating a folder named BACKUP to use as the location for your restored database(s).
To restore your database file, click the Manual Restore button in the Manual tab of the Backup/Restore window.
A dialog box will appear; highlight the .zip file you want to restore (unzip) and click Open.
In the next window, choose the drive and directory to which you want to restore the backup file and then click OK.
254 Admin Guide Chapter Five: Database Utilities GAGEtrak 7 User Guide
When the backup is finished, you will receive a confirmation message saying that the operation was completed successfully.
If you’ve replaced your hard drive or are installing the software to another computer, re-install GAGEtrak first, then restore your
backup database file.
Automatic Backup
If a manual backup has been done in the past, then the file resulting from the automatic backup will be placed in the same
location as that manual backup file. If a manual backup has not been done in the past, then the file resulting from the automatic
backup will be stored in the same location as the database. The application does not backup SQL databases.
To start the backup procedure, click the Automatic Backup button. When the backup is finished, you will see a confirmation
message saying that the operation was successfully completed.
Your data is now backed up. The resulting backup files will be compressed in the industry standard ZIP format. This means that
you can use other utilities such as PKZIP, PC-Tools, WinZip or Norton to restore your files. The backup file will have the same name
as the database file (but will have a .zip extension) and it will be placed in a folder named with the current date, i.e., the folder will
be called 03172015 if the backup is performed on March 17, 2015. You can rename the folder and/or the .zip file.
Automatic Restore
To restore your database file, click the Automatic Restore button in the Automatic tab of the Backup/Restore window.
If a database file exists with the same name as the database file you are restoring, you will be prompted to rename the file you are
restoring:
Click Rename; enter a new name for the file in the dialog box that appears and click OK to complete the restoration of the file. Once
complete, you must connect to your restored, renamed database. See Change Database -> Current Connection.
GAGEtrak 7 User Guide Admin Guide Chapter Five: Database Utilities 255
Backup/Restore – Create Calendar Event Tab
Within the Backup/Restore window, click the Create Calendar Event tab. Here, you can create a backup reminder event for your
electronic calendar application. This utility will not perform the backup of the database. All it does it create a reminder to perform
the backup. It is the administrator’s responsibility to insure that the correct database is being backed up on a regular basis.
Field/Button Description
Select Calendar Select the file format that the calendar event will use. iCalendar is a multi-platform standard used with newer electronic
File Format calendar applications and allows more functionality like Recurrence and Alarms. vCalendar is an older standard that
does not support Recurrence or Alarms.
Select Schedule the alarm for Every Day of the week or only for Active Days. Active Days are the days that are not set to be
Recurrence skipped (determined within Setup -> Settings -> Calendar tab -> Skip Date Entry.
Start Time Select the time of the day at which the alarm should be scheduled.
Include Reminder Check this box to include an electronic reminder when the event is due. The nature of the alarm depends on the nature
/ Alarm and configuration of the electronic calendar application.
Create Event Click this button to create the event based on the settings in this form and export it to the electronic calendar
application. If you wish to email this event to another user, the event can be found in the default application directory:
C:\Program Data\CyberMetrics Corporation\GAGEtrak 7.0\AppFiles\BackupEvent.ics.
256 Admin Guide Chapter Five: Database Utilities GAGEtrak 7 User Guide
Reset Messages
This utility could potentially cause undesirable effects to the data within the application if used without a full understanding of its
use. Please consult your systems administrator and call CyberMetrics Technical Support prior proceeding. The Reset Messages
utility resets the program messages back to their default values.
GAGEtrak 7 User Guide Admin Guide Chapter Five: Database Utilities 257
Calculate All Due Dates
Use this utility to recalculate calibration due dates. For example, if you change the calibration frequencies on all of your
micrometers from 65 Days to 90 Days and you have 50 micrometer records, it’s easier to run this utility than to manually click the
Next Calib button for each of those 50 records. You’ll see the following confirmation when you select this utility:
Click Yes to have GAGEtrak calculate the Next Due Date for every gage record, based on Calibration Frequency and Last Due Date.
It deletes or overwrites any manually entered dates, and dates calculated by issue tracking.
To proceed, click Yes and when the operation is complete, click OK on the confirmation message.
258 Admin Guide Chapter Five: Database Utilities GAGEtrak 7 User Guide
Reset Gage Issue Status
This utility goes through each gage record in the database and to see if a gage has been issued and not returned. All of the
currently issued gages are flagged as issued. Use this utility if any issue tracking records have been deleted.
To proceed, click Yes and when the operation is complete, click OK on the confirmation messaage.
GAGEtrak 7 User Guide Admin Guide Chapter Five: Database Utilities 259
Set Status of Gages
Use this utility only if you’re upgrading from a 1.x version of GAGEtrak or if you imported data from another program or file format.
If you’re upgrading from a 1.x version of GAGEtrak, run this utility after the Data Utility.
This procedure updates changes all empty gage Status fields to status 1 (Active). This utility won’t change the any gage records
that already have a specified Status.
Select Set Status of Gages from the Database Utilities menu; the following window opens:
260 Admin Guide Chapter Five: Database Utilities GAGEtrak 7 User Guide
Admin Guide Chapter Six:
System Maintenance
Maintaining Your Hard Drive
We highly recommend that you run the Windows ScanDisk and Disk Defragmenter utilities to keep your hard disk running
smoothly. Run ScanDisk each week to clean up cross-linked files and other problems. Next, run Disk Defragmenter to reorganize
your files (this keeps your files from being spread out in pieces all over the hard drive). Your disk accesses will run somewhat faster
and your hard drive will be less prone to problems. To run these utilities, check the Start button, select Programs, then choose
Accessories. Highlight System Tools, then select the utility and follow the directions on your screen.
Please check with your IT department or whoever is responsible for maintaining your computer before running these utilities.
We also recommend making sure you have a current backup of your GAGEtrak data before performing any hard drive maintenance.
Maximizing Performance
We recommend that you keep a large amount of empty hard drive space for your operating system’s virtual memory management.
If you have limited resources and GAGEtrak runs slowly, try closing all other applications to devote all available system resources to
GAGEtrak.
GAGEtrak 7 User Guide Admin Guide Chapter Six: System Maintenance 261
Index
A
Acct. No. 101
Accuracy 104, 110, 205, 206, 207
Accuracy Chart 51
Action Required 100
Advanced Filter 36, 188
After 51
ANOVA
ANOVA Components of Variance 135
ANOVA Correction Factor 133
ANOVA Formulas 129
ANOVA Sample Study 131
Appraiser Variation (AV) 112
Archive/Un-Archive 251
As Found Condition 100
Asset Number 45
Audit Trail 229
Automatic Adjustment of Calibration Frequency 225
Average and Range Method 114
B
Backup 253, 254
Backup Automatic 255
Backup Manual 254, 256
Backup/Restore 253
Batch
Batch Issue and Return 90
Before 51
C
Calculate All Due Dates 258
Calendar
Calendar Settings 227
Pop-up Calendar 27
Calibration
Calibration Purpose 205
Calibration Terminology 205
Calibration Entry 103, 105
Calibration Entry From Gage Entry 51
Calibration Frequency 53, 100
Calibration Frequency After Use 53
Calibration Frequency Before Use 53
Calibration Frequency Cycles 53
Calibration Frequency Days 53
Calibration Frequency Days After Issue 53
Calibration Frequency Months 53, 54
Calibration Frequency Weeks 53, 54
Calibration Frequency Years 53, 54
Calibration History 60
Calibration Hours 54
Calibration Labels
Calibration Labels Calibration Label Kit 102
Calibration Standard 56, 59
Calibration Status 100
Calibration Timer 101
Calibrator 53
CalPro (Calibration Procedures) 75
Certificate No. 101
Certificates of Calibration 100, 226
Change Database 22
Change Field Name 197
Change Level 45, 71
Charts. See specific chart titles.
Cloning Gage Records 50
Comments
Gage Entry 45
Copy
Copy Procedures 75
Correction Factor (ANOVA) 133
Corrective Action 78
Current Location 45, 46, 49, 91
Cycles 53, 206
D
Dashboard 18
Additional Schedules Due Tab 18
Calibrations Due Tab 18
Dashboard Due List 223
Database
Change 22
Data Field 196
Date
Next Calibration Due Date 54
Next R&R Due Date 55
Purchase Date 45
Retirement Date 45
Service Date 45
Date Formats 228
Delete Field 197
Department 91, 100
Description
Description Gage 45
Designer Canvas 196
Drawing Number 45, 71
E
Email Report 185
Employee ID
Employee ID Creating 247, 256
Environmental Conditions 101
Equipment Variation (EV) 112
Error Chart 121
Error Message
Error Message Duplicate Value in Index 192
F
Filter
Advanced Filter 36
Filter Archive/Un-Archive 251
Filter Calibration Entry 99
Quick Filter 34
Search Box Navigation Tool 21
G
Gage Frequency Adjusting Interval 82
Gage ID
Archiving by 251
Calibration Entry 100
History 60
Issue Tracking 91
Removing Spaces from 258
Return 92
Gage Records
Cloning 50
Gage Requirements 71
Gage Serial Number 45, 100
Graph 51, 101
H
Hours 54, 101
Humidity 101
I
Import Report 185
Insert Object 223
Inspection Frequency 72
Issue Date 48, 91
Issued Department 46, 91
Issued To 46, 48, 91
Issue Time 48, 91
Issue Tracking 53, 54
Issue Tracking Batch Mode 90
L
Last Rating 81
Last Received 81
Last Reject 81
Last Review 81
Limited Use 104
Linearity 109, 110, 142
Location
Current Location 45, 46, 49, 91
Storage Location 45
Logo 222, 223
Logon
Logon Select Method 229
M
Master Tabs 20
Maximizing Your Performance 261
Maximum 56, 60, 103
Minimum 56, 60, 103
Minus Tolerance 56
Model Number 45
Modify Existing Report 196
Moving Fields 199
MSA 109
From Calibration Entry 113
N
Navigation Menu 18
Undock 19
New Report 194
Next Due Date 53, 54, 55, 100
NIST Number 45
Nominal 59, 103, 104
Normalized Individuals Chart 123
O
Object Insert 223
Open Report 185
Output Report 185
P
Part Appraiser Average Control Chart 126
Part Control Method 72
Part Entry 71
Part Number 48, 65, 71, 91
Part Variation (PV) 112
Performance. See Maximizing Performance
Personnel 247
Plus Tolerance 56
Pop-up Calendar 27
Precision 111
Pressure 101
Preview Report 200
Procedure 64, 207
Copying 75
Inspection Procedure for Parts 71
Procedure Entry 73
Procedure Name 64
Purchase Date 45
Purchase Order Number 48, 91
Q
Quick Filter 34
R
Range Chart 120
Range Method 114
Received Date 48, 92
Received From 48, 92
Received Time 48
Records
Calibration Records 51, 54, 56, 99, 100, 225, 251
Gage Records 101
Reference Standard 45
Remove Spaces from Gage IDs 258
Repeatability 111
Repeatability Range Control Chart 125
Report - Email 185
Report - Import 185
Report - Modify Existing 196
Report - Open 185
Report - Output 185
Report - Preview 200
Reports 179
Reproducibility 111
Reset Gage Issue Status 259
Restore 253
Automatic 255
Manual 254
Retirement Date 45
R&R 54, 55, 101
Charts 119
R&R Frequency 54
Run Chart and Average Chart 122
S
Scatter Plot 125
Schedule
Calibration Schedule 53, 206
Gage R&R Schedule 67
Search Box Navigation Tool 21
Security
Enable 228
Messages 228
Serial Number 17
Service Date 45
Service Request 78, 240
Set Status of Gages 260
Settings 100, 228
Short Method. See Range Method
Skip Dates 53, 227
Stability 109, 112, 157
Stability Control Charts 158
Staff Entry 247
Standard ID 56, 103
Status
Calibration 100
Service Request 79
Status ID 260
Status ID Gage Entry 45
Storage Location 45
Supplier Code 45, 80
System Maintenance 261
T
Technical Support 17
Text Field 196
Total Variation (TV) 112
Training
Staff Records 248
Type
Calibration 61
Calibration Type 100
Gage 45, 206
Gage R&R Study 116, 155
Issue 48, 91
Service Request 78
Standard 56, 59, 103
Supplier 80
U
Uncertainty 56, 101
Unit of Measure
Gage Entry 45
Usage 206
User Defined 66
W
Whiskers Chart 123
X
X - Y Plot of Averages by Size 124
Z
Zip File 254
It gets even better.
This line of additional products is yet another reason
GAGEtrak is the #1 calibration management software solution in the world.
Streamline your workflow, improve productivity and reduce costs - contact us today to place your order.
Report Viewer is an easy-to-use, stand-alone desktop utility that connects to your GAGEtrak database(s),
allowing you to generate thorough reports to analyze and stay ahead of trends, forecast workloads, improve
efficiency and minimize costs. Report Viewer offers the convenience and simplicity of accessing only the
information you need, allowing you to have more control over your quality management program.
Issue & Return Module Never lose track of your gages again! This simple, easy-to-use interface gives
you quick access to GAGEtrak’s Issue Gages, Return Gages and Kit Entry screens and most importantly, it
enables you to provide a traceable gage usage history for every gage. This module is a perfect solution for
a gage or tool crib operator who does not need a full copy of GAGEtrak.
The Calibration Label Kit lets you create bar-coded labels for all of your equipment directly out of
GAGEtrak. This compact Brother ® printer comes complete with cables, label design software and everything
else you’ll need to get started. The harsh-environment labels are resistant to moisture, temperature extremes,
industrial chemicals, UV and abrasion and are available in a variety of sizes and colors.
CyberSensor is an automated ambient temperature and humidity sensor that communicates with GAGEtrak
via a USB connection. When a calibration is passed, the Temperature and Humidity fields within the GAGEtrak
calibration record are automatically populated with CyberSensor data, making your calibration documentation
even more complete. Improve efficiency and the reliability of your calibrations with CyberSensor’s accurate
temperature and relative humidity monitoring.
GAGEtrak’s Total Calibration Solution (TCS) includes everything else you need for ISO 9000 and
ISO/TS 16949 calibration compliance at a special package price. TCS includes GAGEtrak Software, a Calibration
Label Kit, CalPro Calibration Procedures and an Annual Maintenance and Support Agreement (MA). Double your
efficiency with TCS+ which includes all of the contents of TCS plus an additional GAGEtrak license and MA.
CalPro, an indispensable asset for any calibration department, is a database of step-by-step calibration
procedures for more than sixty commonly used inspection gages, instruments and reference standards. Any or
all CalPro procedures can be imported into GAGEtrak using the import utility provided or printed as hard copy
from the DOC files included on the CalPro media.