Next Issue
Volume 2, May
Previous Issue
Volume 2, March
 
 
sensors-logo

Journal Browser

Journal Browser

Sensors, Volume 2, Issue 4 (April 2002) – 3 articles , Pages 127-163

  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list.
  • You may sign up for e-mail alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.
Order results
Result details
Section
Select all
Export citation of selected articles as:
94 KiB  
Article
Natural Monocrystalline Pyrite as Sensor for Potentiometric Redox Titrations. Part I. Titrations with Permanganate
by M. M. Antonijevic, R. P. Mihajlovic and B. V. Vukanovic
Sensors 2002, 2(4), 153-163; https://doi.org/10.3390/s20400153 - 30 Apr 2002
Cited by 4 | Viewed by 8440
Abstract
Results obtained in potentiometric titrations of Fe(II), Mn(II), Fe(CN)64-, C2O42- and As(III) with standard potassium permanganate solution, are presented. The titration end point (TEP) was detected with a universal electrode whose sensor is natural crystalline pyrite. [...] Read more.
Results obtained in potentiometric titrations of Fe(II), Mn(II), Fe(CN)64-, C2O42- and As(III) with standard potassium permanganate solution, are presented. The titration end point (TEP) was detected with a universal electrode whose sensor is natural crystalline pyrite. The titrations of As(III) were carried out in HCl (1.2 M) and H2SO4 solutions (0.1- 4.5 M), whereas oxalate was determined in H2SO4 (0.1-4.5 M). Iron(II) and hexacyanoferrate(II) were titrated in H2SO4 and also in H3PO4 solutions (0.1-4.5 M). The titrations of Mn(II) were performed in H2P2O72- media at pH 4.0, 5.0, 6.0 and 7.0. The results obtained by using the pyrite electrode were compared with those obtained by the application of a Pt-electrode, and good agreement, reproducibility and accuracy were obtained. The potentials in the course of the titration and at the end-point (TEP) are rapidly established. The potential changes at the TEP ranged from 90 to 330 mV/0.1 mL, depending on the titrated system. The highest changes were observed in titrations of Fe(II) in H3PO4 (240-330 mV/0.1 mL). Reversed titrations were also performed and accurate and reproducible results were obtained. Full article
Show Figures

Figure 1

183 KiB  
Article
Asymptotic Regional Boundary Observer in Distributed Parameter Systems via Sensors Structures
by Raheam Al-Saphory
Sensors 2002, 2(4), 137-152; https://doi.org/10.3390/s20400137 - 26 Apr 2002
Cited by 6 | Viewed by 9150
Abstract
The purpose of this paper is to study the concept of asymptotic regional observer in connection with the characterizations of sensors. We give various results related to different types of measurements, of domains and boundary conditions. Furthermore, we show that the measurements structures [...] Read more.
The purpose of this paper is to study the concept of asymptotic regional observer in connection with the characterizations of sensors. We give various results related to different types of measurements, of domains and boundary conditions. Furthermore, we show that the measurements structures allow the existence of regional observer and we give a sufficient condition for such observer. We also show that, there exists a dynamical system for the considered system is not observer in the usual sense, but it may be regional boundary observer. Full article
Show Figures

Figure 1

118 KiB  
Article
Planar Amperometric Glucose Sensor Based on Glucose Oxidase Immobilized by Chitosan Film on Prussian Blue Layer
by Jianzhong Zhu, Ziqiang Zhu, Zongsheng Lai, Rong Wang, Xiaoming Guo, Xiaqin Wu, Guoxiong Zhang, Zongrang Zhang, Yiting Wang and Zongyou Chen
Sensors 2002, 2(4), 127-136; https://doi.org/10.3390/s20400127 - 23 Apr 2002
Cited by 73 | Viewed by 16124
Abstract
A planar amperometric glucose microsensor based on glucose oxidase immobilized by chitosan film on Prussian Blue layer has been developed. The experimental results show that the optimum detection potential is 50 mV (versus Ag/AgCl) and the optimum pH is 6.5. Under the selective [...] Read more.
A planar amperometric glucose microsensor based on glucose oxidase immobilized by chitosan film on Prussian Blue layer has been developed. The experimental results show that the optimum detection potential is 50 mV (versus Ag/AgCl) and the optimum pH is 6.5. Under the selective conditions the sensor exhibits excellent sensitivity of 98 nA/M and a linear range of 0.1-6.0 mM. The apparent Michanelis-Menten constant of the sensor is 21 mM. The response time is less than 60 seconds. No apparent change in the response to glucose was observed during one month. Foremost, the interference of ascorbic and uric acids can be avoided due to selective permeability of chitosan film and electrocatalysis of PB layer to H2O2. The sensor has been applied to detect glucose in human blood serum. Full article
Show Figures

Figure 1

Previous Issue
Next Issue
Back to TopTop