LHCb RICH 2 engineering design review report / Adinolfi, M (U. Oxford (main) ) ; Albrecht, E (CERN) ; Allebone, L R (Imperial Coll., London ) ; Ameri, M (Genoa U. ; INFN, Genoa) ; Barber, G J (Imperial Coll., London ) ; Barczyk, A (Edinburgh U. ) ; Bellunato, T F (Milan U. ; INFN, Milan ; CERN) ; Benayoun, M (CERN) ; Bibby, J (U. Oxford (main) ) ; Braem, André (CERN) et al.
The LHCb detector is a single arm spectrometer designed to exploit the large number of b-hadrons produced at the LHC in order to make precision studies of CP asymmetries and of rare decays in the B-meson system. It is therefore essential for the experiment that the detector configuration includes a particle identification system with high separation power between kaons and pions. [...]
LHCb-2002-009.- Geneva : CERN, 2002 - 64 p. EDR Access to fulltext document: PS.GZ; Fulltext: PDF;
2.
Framework TDR for the LHCb Upgrade : Technical Design Report / LHCb collaboration
This document is a Framework Technical Design Report for the upgrade of the LHCb experiment. [...]
CERN-LHCC-2012-007 ; LHCb-TDR-12.
- 2012. - 62 p. (Technical design report. LHCb ; 12)
Fulltext
3.
Performance of a cluster of Multi-anode Photomultipliers equipped with lenses for use in a prototype RICH detector / Albrecht, E (CERN) ; Baker, J (Rutherford) ; Barber, G J (Imperial Coll., London) ; Bibby, J (Oxford U.) ; Calvi, M (Milan Bicocca U. ; INFN, Milan Bicocca) ; Charles, M J (Oxford U.) ; Duane, A (Imperial Coll., London) ; Easo, S (Glasgow U.) ; Eisenhardt, S (Edinburgh U. ) ; Eklund, L (CERN) et al.
A cluster of Multi--anode Photomultiplier Tubes (MaPMTs) equipped with focusing lenses in front of the tubes was tested in a prototype Ring Imaging \v{C}erenkov detector in a charged particle beam. The readout electronics were capable of capturing the data at 40~MHz. [...]
CERN-EP-2001-051; LHCb-2001-091.- Geneva : CERN, 2002 - 23 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 488 (2002) 110-130 Fulltext: ep-2001-051 - PDF; lhcb-2001-091 - PDF; - CERN library copies
4.
Performance of the LHCb RICH photo-detectors and readout in a system test using charged particles from a 25 ns-structured beam / Adinolfi, M (Bristol U.) ; Albrecht, E (CERN) ; D’Ambrosio, C (CERN) ; Gys, T (CERN) ; Morant, J (CERN) ; Piedigrossi, D (CERN) ; Patel, M (CERN) ; Wyllie, K (CERN) ; Ameri, M (INFN, Genoa ; Genoa U.) ; Fontanelli, F (INFN, Genoa ; Genoa U.) et al.
The LHCb experiment at the CERN Large Hadron Collider (LHC) utilises two Ring Imaging CHerenkov (RICH) detectors for particle identification. To verify that the RICH assembly will perform as expected prior to installation, an array of 48 production Hybrid Photon Detectors and their readout have been tested under realistic running conditions in a 25 ns-structured charged particle beam provided by the SPS facility at CERN. [...]
2009 - Published in : Nucl. Instrum. Methods Phys. Res., A 603 (2009) 287-293
5.
Performance of a multianode photo multiplier cluster equipped with lenses / Gibson, V (Cambridge U. (main) ) ; Katvars, S (Cambridge U. (main) ) ; Wotton, S A (Cambridge U. (main) ) ; Albrecht, E (CERN) ; Eklund, L (CERN) ; Eisenhardt, S (Edinburgh U.) ; Muheim, F (Edinburgh U.) ; Playfer, S (Edinburgh U.) ; Petrolini, A (Genoa U. ) ; Easo, S (Glasgow U.) et al.
Studies of Multi{anode Photo Multiplier Tubes (MaPMTs), which are a possible photo{detector for the LHCb RICHes, are presented. These studies include those of a cluster of MaPMTs equipped with lenses at the SPS beam during the Summer of 1999. [...]
LHCb-2000-083.- Geneva : CERN, 2001 - 29 p. Access to fulltext document: PS.GZ; Fulltext: PDF;
6.
The LHCb Detector at the LHC / LHCb Collaboration
The LHCb experiment is dedicated to precision measurements of CP violation and rare decays of B hadrons at the Large Hadron Collider (LHC) at CERN (Geneva). The initial configuration and expected performance of the detector and associated systems, as established by test beam measurements and simulation studies, is described..
LHCb-DP-2008-001.- 2008 - Published in : JINST 3 (2008) S08005 SISSA/IOP Open Access article: PDF;
In : The CERN Large Hadron Collider - Please contact the library if you need to access this document.
7.
Proposal for multi-anode photo multiplier tubes as photo detectors for the LHCb RICH / Muheim, F (Edinburgh U.) ; Gibson, V (Cambridge U.) ; Katvars, S (Cambridge U.) ; Wotton, S (Cambridge U.) ; Albrecht, E (CERN) ; Bernet, R (Edinburgh U.) ; Eisenhardt, S (Edinburgh U.) ; Muheim, F (Edinburgh U.) ; Playfer, S (Edinburgh U.) ; Cuneo, S (Genoa U.) et al.
We propose to use the Multianode Photo Multiplier Tubes (MAPMT) as the photosensitive device for the Ring Imaging Cherenkov (RICH) detector in the LHCb experiment. We demonstrate that MAPMT meet the specifications which are required to perform excellent particle identification of charged tracks over the full acceptance. [...]
LHCb-2000-065.- Geneva : CERN, 2001 - 27 p. Access to fulltext document: PS.GZ; Fulltext: PDF;
8.
Till Moritz Karbach, Scientific Legacy / LHCb Collaboration
We are deeply touched by the sudden loss of our dear friend and colleague Till Moritz Karbach. With this memorial book we wish to commemorate Moritz’ scientific legacy, and what Moritz meant to us as a friend..
LHCb-PUB-2015-010; CERN-LHCb-PUB-2015-010.- Geneva : CERN, 2015 - 194 p. Fulltext: PDF;
9.
Performance of the LHCb RICH detectors during LHC Run 2 / Calabrese, R. (INFN, Ferrara ; U. Ferrara (main)) ; Fiorini, M. (INFN, Ferrara ; U. Ferrara (main)) ; Luppi, E. (INFN, Ferrara ; U. Ferrara (main)) ; Minzoni, L. (INFN, Ferrara ; U. Ferrara (main)) ; Slazyk, I. (INFN, Ferrara ; U. Ferrara (main)) ; Tomassetti, L. (INFN, Ferrara ; U. Ferrara (main)) ; Bartolini, M. (INFN, Genoa ; U. Genoa) ; Cardinale, R. (INFN, Genoa ; U. Genoa) ; Fontanelli, F. (INFN, Genoa ; U. Genoa) ; Petrolini, A. (INFN, Genoa ; U. Genoa) et al.
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. [...]
arXiv:2205.13400; LHCb-DP-2021-004.- 2022-07-06 - 23 p. - Published in : JINST 17 (2022) P07013 Fulltext: document - PDF; 2205.13400 - PDF;
10.
A Prototype RICH Detector Using Multi-Anode Photo Multiplier Tubes and Hybrid Photo-Diodes / Albrecht, E (CERN) ; Barber, G J (Imperial Coll., London) ; Bibby, J H (U. Oxford (main)) ; Brook, N H (Glasgow U.) ; Doucas, G (U. Oxford (main)) ; Duane, A (Imperial Coll., London) ; Easo, S (Glasgow U.) ; Eklund, L (Cambridge U. (main)) ; French, M (Rutherford) ; Gibson, V (CERN) et al.
The performance of a prototype Ring Imaging Cherenkov Detector is studied using a charged particle beam. The detector performance, using CF4 and air as radiators, is described. [...]
hep-ex/0001053; LHCb-2000-68b; GLAS-PPE-1999-22.- Glasgow : Glasgow Univ., 2001 - Published in : Nucl. Instrum. Methods Phys. Res., A 456 (2001) 233-47 Access to fulltext document: 0001053 - PDF; lhcb-2000-68b - PDF; External link: hep-ex/0001053 PDF

Haven't found what you were looking for? Try your search on other servers:
recid:691478 in Amazon
recid:691478 in CERN EDMS
recid:691478 in CERN Intranet
recid:691478 in CiteSeer
recid:691478 in Google Books
recid:691478 in Google Scholar
recid:691478 in Google Web
recid:691478 in IEC
recid:691478 in IHS
recid:691478 in INSPIRE
recid:691478 in ISO
recid:691478 in KISS Books/Journals
recid:691478 in KISS Preprints
recid:691478 in NEBIS
recid:691478 in SLAC Library Catalog