1.
|
|
CERN Academic Training on hadron therapy - New treatment options at CNAO: the Boron Neutron Capture Therapy
/ Necchi, Monica (speaker)
AbstractBoron Neutron Capture Therapy (BNCT) is a technique that aims at selectively treating tumour cells while sparing healthy tissue, by concentrating a boron compound in the tumour mass and then exposing the tumour to thermal neutrons: . The technique was first proposed soon after the discovery of the neutron and the observation that boron easily captures low-energy neutrons [...]
2023 - 4002.
Academic Training Lecture Regular Programme, 2023-2024
External link: Event details
In : CERN Academic Training on hadron therapy - New treatment options at CNAO: the Boron Neutron Capture Therapy
|
|
2.
|
Operational experience of the gas gain monitoring system of the CMS RPC muon detectors
/ Colafranceschi, S (Frascati) ; Benussi, L (Frascati) ; Bianco, S (Frascati) ; Fabbri, L (Frascati) ; Giardoni, M (Frascati) ; Ortenzi, B (Frascati) ; Paolozzi, A (Rome U.) ; Passamonti, L (Frascati) ; Piccolo, D (Frascati) ; Pierluigi, D (Frascati) et al.
Performances of the Gas Gain Monitoring system of the CMS RPC muon detectors after one year of operation at the scaled down closed loop recirculation gas system are presented. The GGM is made of 12 single-gap RPC's arranged in a cosmic ray telescope, with charge readout for online monitoring of working point. [...]
2010 - 2 p.
- Published in : Nucl. Instrum. Methods Phys. Res., A 617 (2010) 146-147
In : 11th Pisa Meeting on Advanced Detectors on Frontier Detectors For Frontier Physics, La Biodola, Italy, 24 - 30 May 2009, pp.146-147
|
|
3.
|
Resistive plate chamber commissioning and performance in CMS
/ Roselli, G (Bari U. ; INFN, Bari) ; Abbrescia, M (Bari U. ; INFN, Bari) ; Iaselli, G (Bari U. ; INFN, Bari) ; Marangelli, B (Bari U. ; INFN, Bari) ; Natalin, S (Bari U. ; INFN, Bari) ; Nuzzo, S (Bari U. ; INFN, Bari) ; Pugliese, G (Bari U. ; INFN, Bari) ; Romano, F (Bari U. ; INFN, Bari) ; Trentadue, R (Bari U. ; INFN, Bari) ; Tupputi, S (Bari U. ; INFN, Bari) et al.
The CMS muon system is conceived for trigger and muon track reconstruction. The redundancy and robustness of the system are guaranteed by three complementary subsystems: drift tube in the barrel, cathode strip chamber in the end-cap and resistive plate chamber in barrel and end-cap. [...]
2009
- Published in : Nucl. Instrum. Methods Phys. Res., A 602 (2009) 696-699
|
|
4.
|
A configurable tracking algorithm to detect cosmic muon tracks for the CMS-RPC based technical trigger
/ Rajan, R T (INFN, Bari ; Bari U.) ; Colaleo, A (INFN, Bari) ; Loddo, F (INFN, Bari) ; Maggi, M (INFN, Bari) ; Ranieri, A (INFN, Bari) ; Abbrescia, M (INFN, Bari ; Bari U.) ; Guida, R (CERN) ; Iaselli, G (INFN, Bari ; Bari U.) ; Nuzzo, S (INFN, Bari ; Bari U.) ; Pugliese, G (INFN, Bari ; Bari U.) et al.
In the CERN CMS experiment at LHC Collider special trigger signals called Technical Triggers will be used for the purpose of test and calibration. The Resistive Plate Chambers (RPC) based Technical Trigger system is a part of the CMS muon trigger system and is designed to detect cosmic muon tracks. [...]
2009
- Published in : Nucl. Instrum. Methods Phys. Res., A 602 (2009) 792-795
|
|
5.
|
The compact muon solenoid RPC barrel detector
/ Colaleo, A (INFN, Bari) ; Loddo, F (INFN, Bari) ; Maggi, M (INFN, Bari) ; Ranieri, A (INFN, Bari) ; Abbrescia, M (INFN, Bari ; Bari U.) ; Guida, R (CERN) ; Iaselli, G (INFN, Bari ; Bari U.) ; Marangelli, B (INFN, Bari ; Bari U.) ; Natali, S (INFN, Bari ; Bari U.) ; Nuzzo, S (INFN, Bari ; Bari U.) et al.
Resistive Plate Chambers (RPC) have been chosen as dedicated trigger muon detectors for the Compact Muon Solenoid [CMS collaboration, Technical Design Report, CERN/LHCC 94-38, 1994. [1]] experiment at the Large Hadron Collider [The LHC project at CERN, LHC-project-report-36, 1996. [...]
2009
- Published in : Nucl. Instrum. Methods Phys. Res., A 602 (2009) 674-678
|
|
6.
|
Commissioning and performance of the CMS pixel tracker with cosmic ray muons
/ CMS Collaboration
The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. [...]
arXiv:0911.5434; CMS-CFT-09-001; CMS-CFT-09-001.-
Geneva : CERN, 2010 - 37 p.
- Published in : JINST 5 (2010) T03007
Fulltext: arXiv:0911.5434 - PDF; fermilab-pub-10-144-cms - PDF; IOP Open Access article: PDF;
|
|
7.
|
Measurement of the muon stopping power in lead tungstate
/ CMS Collaboration
A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO$_4$) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/$c$ to 1 TeV/$c$. [...]
arXiv:0911.5397; CMS-CFT-09-005; CMS-CFT-09-005.-
2010 - 31 p.
- Published in : JINST 5 (2010) P03007
Fulltext: fermilab-pub-10-146-cms - PDF; arXiv:0911.5397 - PDF; IOP Open Access article: PDF;
|
|
8.
|
|
9.
|
Performance of CMS muon reconstruction in cosmic-ray events
/ CMS Collaboration
The performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a broad range of muon momenta, and were found to be in good agreement with expectations from Monte Carlo simulation. [...]
arXiv:0911.4994; CMS-CFT-09-014; CMS-CFT-09-014.-
2010 - 47 p.
- Published in : JINST 5 (2010) T03022
Fulltext: arXiv:0911.4994 - PDF; fermilab-pub-10-148-cms - PDF; IOP Open Access article: PDF; External link: Fulltext
|
|
10.
|
Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons
/ CMS Collaboration
During autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. [...]
arXiv:0911.4996; CMS-CFT-09-002; CMS-CFT-09-002.-
2010 - 45 p.
- Published in : JINST 5 (2010) T03008
Fulltext: fermilab-pub-10-147-cms - PDF; arXiv:0911.4996 - PDF; IOP Open Access article: PDF; External link: Preprint
|
|