-
Towards imaging-spectro-polarimetry of solar flares in the X-rays
Authors:
Sergio Fabiani,
John Rankin,
Stefano Basso,
Enrico Costa,
Ettore Del Monte,
Klaus Desch,
Alessandro Di Marco,
Markus Gruber,
Jochen Kaminski,
Dawoon E. Kim,
Saba Imtiaz,
Carlo Lefevre,
Pasqualino Loffredo,
Hemant Manikantan,
Alfredo Morbidini,
Fabio Muleri,
Giovanni Pareschi,
Vladilavs Plesanovs,
Ajay Ratheesh,
Alda Rubini,
Paolo Soffitta,
Daniele Spiga
Abstract:
X-ray polarimetry of solar flares is still a not well established field of observation of our star. Past polarimeters were not able to measure with a high significance the polarization in X-rays from solar flares. Moreover, they had no imaging capabilities and measured only the polarization by integrating on all the image of the source. We propose a mission concept based on a gas photoelectric pol…
▽ More
X-ray polarimetry of solar flares is still a not well established field of observation of our star. Past polarimeters were not able to measure with a high significance the polarization in X-rays from solar flares. Moreover, they had no imaging capabilities and measured only the polarization by integrating on all the image of the source. We propose a mission concept based on a gas photoelectric polarimeter, coupled with multilayer lobster-eye optics, to perform imaging-spectro-polarimetry of solar flares while monitoring the entire solar disc.
△ Less
Submitted 4 July, 2024;
originally announced July 2024.
-
The High Energy X-ray Probe (HEX-P): Instrument and Mission Profile
Authors:
Kristin K. Madsen,
Javier A. García,
Daniel Stern,
Rashied Armini,
Stefano Basso,
Diogo Coutinho,
Brian W. Grefenstette,
Steven Kenyon,
Alberto Moretti,
Patrick Morrisey,
Kirpal Nandra,
Giovanni Pareschi,
Peter Predehl,
Arne Rau,
Daniele Spiga,
Jörn Willms,
William W. Zhang
Abstract:
The High Energy X-ray Probe is a proposed NASA probe-class mission that combines the power of high angular resolution with a broad X-ray bandpass to provide the necessary leap in capabilities to address the important astrophysical questions of the next decade. HEX-P achieves breakthrough performance by combining technologies developed by experienced international partners. HEX-P will be launched i…
▽ More
The High Energy X-ray Probe is a proposed NASA probe-class mission that combines the power of high angular resolution with a broad X-ray bandpass to provide the necessary leap in capabilities to address the important astrophysical questions of the next decade. HEX-P achieves breakthrough performance by combining technologies developed by experienced international partners. HEX-P will be launched into L1 to enable high observing efficiency. To meet the science goals, the payload consists of a suite of co-aligned X-ray telescopes designed to cover the 0.2 - 80 keV bandpass. The High Energy Telescope (HET) has an effective bandpass of 2 - 80 keV, and the Low Energy Telescope (LET) has an effective bandpass of 0.2 - 20 keV. The combination of bandpass and high observing efficiency delivers a powerful platform for broad science to serve a wide community. The baseline mission is five years, with 30% of the observing time dedicated to the PI-led program and 70% to a General Observer (GO) program. The GO program will be executed along with the PI-led program.
△ Less
Submitted 7 December, 2023;
originally announced December 2023.
-
PathWise: a flexible, open-source library for the Resource Constrained Shortest Path
Authors:
Matteo Salani,
Saverio Basso
Abstract:
In this paper, we consider a fundamental and hard combinatorial problem: the Resource Constrained Shortest Path Problem (RCSPP). We describe the implementation of a flexible, open-source library for the solution of the RCSPP, called PathWise, capable of tackling several variants of the problem. We designed PathWise with the final user in mind, developing easy-to-use interfaces without compromising…
▽ More
In this paper, we consider a fundamental and hard combinatorial problem: the Resource Constrained Shortest Path Problem (RCSPP). We describe the implementation of a flexible, open-source library for the solution of the RCSPP, called PathWise, capable of tackling several variants of the problem. We designed PathWise with the final user in mind, developing easy-to-use interfaces without compromising performance. We provide computational experiments on three classes of instances of the RCSPP, namely RCSPP on cyclic networks, RCSPP on large acyclic networks, and RCSPP on ad-hoc cyclic networks. We show that PathWise is packed off-the-shelf with algorithms capable of tackling all classes. This paper represents the first step along the journey of devising and implementing a comprehensive open-source library for a large variety of RCSPPs. The current version of the library carries exact algorithms for the RCSPP but new algorithms, both heuristic and exact, will be added thanks to the flexible design. We also foresee PathWise becoming a platform ready for data-driven and process-driven methodologies for these types of problems.
△ Less
Submitted 14 June, 2023;
originally announced June 2023.
-
First light of BEaTriX, the new testing facility for the modular X-ray optics of the ATHENA mission
Authors:
S. Basso,
B. Salmaso,
D. Spiga,
M. Ghigo,
G. Vecchi,
G. Sironi,
V. Cotroneo,
P. Conconi,
E. Redaelli,
A. Bianco,
G. Pareschi,
G. Tagliaferri,
D. Sisana,
C. Pelliciari,
M. Fiorini,
S. Incorvaia,
M. Uslenghi,
L. Paoletti,
C. Ferrari,
R. Lolli,
A. Zappettini,
M. Sanchez del Rio,
G. Parodi,
V. Burwitz,
S. Rukdee
, et al. (13 additional authors not shown)
Abstract:
The Beam Expander Testing X-ray facility (BEaTriX) is a unique X-ray apparatus now operated at the Istituto Nazionale di Astrofisica (INAF), Osservatorio Astronomico di Brera (OAB), in Merate, Italy. It has been specifically designed to measure the point spread function (PSF) and the effective area (EA) of the X-ray mirror modules (MMs) of the Advanced Telescope for High-ENergy Astrophysics (ATHEN…
▽ More
The Beam Expander Testing X-ray facility (BEaTriX) is a unique X-ray apparatus now operated at the Istituto Nazionale di Astrofisica (INAF), Osservatorio Astronomico di Brera (OAB), in Merate, Italy. It has been specifically designed to measure the point spread function (PSF) and the effective area (EA) of the X-ray mirror modules (MMs) of the Advanced Telescope for High-ENergy Astrophysics (ATHENA), based on silicon pore optics (SPO) technology, for verification before integration into the mirror assembly. To this end, BEaTriX generates a broad, uniform, monochromatic, and collimated X-ray beam at 4.51 keV. [...] In BEaTriX, a micro-focus X-ray source with a titanium anode is placed in the focus of a paraboloidal mirror, which generates a parallel beam. A crystal monochromator selects the 4.51 keV line, which is expanded to the final size by a crystal asymmetrically cut with respect to the crystalline planes. [...] After characterization, the BEaTriX beam has the nominal dimensions of 170 mm x 60 mm, with a vertical divergence of 1.65 arcsec and a horizontal divergence varying between 2.7 and 3.45 arcsec, depending on the monochromator setting: either high collimation or high intensity. The flux per area unit varies from 10 to 50 photons/s/cm2 from one configuration to the other. The BEaTriX beam performance was tested using an SPO MM, whose entrance pupil was fully illuminated by the expanded beam, and its focus was directly imaged onto the camera. The first light test returned a PSF and an EA in full agreement with expectations. As of today, the 4.51 keV beamline of BEaTriX is operational and can characterize modular X-ray optics, measuring their PSF and EA with a typical exposure of 30 minutes. [...] We expect BEaTriX to be a crucial facility for the functional test of modular X-ray optics, such as the SPO MMs for ATHENA.
△ Less
Submitted 7 July, 2022; v1 submitted 30 June, 2022;
originally announced June 2022.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
Thin glass shells for active optics for future space telescopes
Authors:
Gabriele Vecchi,
Stefano Basso,
Marta Civitani,
Mauro Ghigo,
Giovanni Pareschi,
Bianca Salmaso
Abstract:
We present a method for the manufacturing of thin shells of glass, which appears promising for the development of active optics for future space telescopes. The method exploits the synergy of different mature technologies, while leveraging the commercial availability of large, high-quality sheets of glass, with thickness up to few millimeters. The first step of the method foresees the pre-shaping…
▽ More
We present a method for the manufacturing of thin shells of glass, which appears promising for the development of active optics for future space telescopes. The method exploits the synergy of different mature technologies, while leveraging the commercial availability of large, high-quality sheets of glass, with thickness up to few millimeters. The first step of the method foresees the pre-shaping of flat substrates of glass by replicating the accurate shape of a mold via hot slumping technology. The replication concept is advantageous for making large optics composed of many identical or similar segments. After the hot slumping, the shape error residual on the optical surface is addressed by applying a deterministic sub-aperture technology as computer-controlled bonnet polishing and/or ion beam figuring. Here we focus on the bonnet polishing case, during which the thin, deformable substrate of glass is temporary stiffened by a removable holder. In this paper, we report on the results so far achieved on a 130 mm glass shell case study.
△ Less
Submitted 13 June, 2019;
originally announced June 2019.
-
Physics potential of the International Axion Observatory (IAXO)
Authors:
E. Armengaud,
D. Attie,
S. Basso,
P. Brun,
N. Bykovskiy,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
M. Cicoli,
M. Civitani,
C. Cogollos,
J. P. Conlon,
D. Costa,
T. Dafni,
R. Daido,
A. V. Derbin,
M. A. Descalle,
K. Desch,
I. S. Dratchnev,
B. Döbrich,
A. Dudarev,
E. Ferrer-Ribas,
I. Fleck,
J. Galán,
G. Galanti
, et al. (66 additional authors not shown)
Abstract:
We review the physics potential of a next generation search for solar axions: the International Axion Observatory (IAXO). Endowed with a sensitivity to discover axion-like particles (ALPs) with a coupling to photons as small as $g_{aγ}\sim 10^{-12}$ GeV$^{-1}$, or to electrons $g_{ae}\sim$10$^{-13}$, IAXO has the potential to find the QCD axion in the 1 meV$\sim$1 eV mass range where it solves the…
▽ More
We review the physics potential of a next generation search for solar axions: the International Axion Observatory (IAXO). Endowed with a sensitivity to discover axion-like particles (ALPs) with a coupling to photons as small as $g_{aγ}\sim 10^{-12}$ GeV$^{-1}$, or to electrons $g_{ae}\sim$10$^{-13}$, IAXO has the potential to find the QCD axion in the 1 meV$\sim$1 eV mass range where it solves the strong CP problem, can account for the cold dark matter of the Universe and be responsible for the anomalous cooling observed in a number of stellar systems. At the same time, IAXO will have enough sensitivity to detect lower mass axions invoked to explain: 1) the origin of the anomalous "transparency" of the Universe to gamma-rays, 2) the observed soft X-ray excess from galaxy clusters or 3) some inflationary models. In addition, we review string theory axions with parameters accessible by IAXO and discuss their potential role in cosmology as Dark Matter and Dark Radiation as well as their connections to the above mentioned conundrums.
△ Less
Submitted 6 June, 2019; v1 submitted 19 April, 2019;
originally announced April 2019.
-
The enhanced X-ray Timing and Polarimetry mission - eXTP
Authors:
ShuangNan Zhang,
Andrea Santangelo,
Marco Feroci,
YuPeng Xu,
FangJun Lu,
Yong Chen,
Hua Feng,
Shu Zhang,
Søren Brandt,
Margarita Hernanz,
Luca Baldini,
Enrico Bozzo,
Riccardo Campana,
Alessandra De Rosa,
YongWei Dong,
Yuri Evangelista,
Vladimir Karas,
Norbert Meidinger,
Aline Meuris,
Kirpal Nandra,
Teng Pan,
Giovanni Pareschi,
Piotr Orleanski,
QiuShi Huang,
Stephane Schanne
, et al. (125 additional authors not shown)
Abstract:
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In ad…
▽ More
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
Efficient algorithms to discover alterations with complementary functional association in cancer
Authors:
Rebecca Sarto Basso,
Dorit S. Hochbaum,
Fabio Vandin
Abstract:
Recent large cancer studies have measured somatic alterations in an unprecedented number of tumours. These large datasets allow the identification of cancer-related sets of genetic alterations by identifying relevant combinatorial patterns. Among such patterns, mutual exclusivity has been employed by several recent methods that have shown its effectivenes in characterizing gene sets associated to…
▽ More
Recent large cancer studies have measured somatic alterations in an unprecedented number of tumours. These large datasets allow the identification of cancer-related sets of genetic alterations by identifying relevant combinatorial patterns. Among such patterns, mutual exclusivity has been employed by several recent methods that have shown its effectivenes in characterizing gene sets associated to cancer. Mutual exclusivity arises because of the complementarity, at the functional level, of alterations in genes which are part of a group (e.g., a pathway) performing a given function. The availability of quantitative target profiles, from genetic perturbations or from clinical phenotypes, provides additional information that can be leveraged to improve the identification of cancer related gene sets by discovering groups with complementary functional associations with such targets.
In this work we study the problem of finding groups of mutually exclusive alterations associated with a quantitative (functional) target. We propose a combinatorial formulation for the problem, and prove that the associated computation problem is computationally hard. We design two algorithms to solve the problem and implement them in our tool UNCOVER. We provide analytic evidence of the effectiveness of UNCOVER in finding high-quality solutions and show experimentally that UNCOVER finds sets of alterations significantly associated with functional targets in a variety of scenarios. In addition, our algorithms are much faster than the state-of-the-art, allowing the analysis of large datasets of thousands of target profiles from cancer cell lines. We show that on one such dataset from project Achilles our methods identify several significant gene sets with complementary functional associations with targets.
△ Less
Submitted 26 March, 2018;
originally announced March 2018.
-
Contributions of the Cherenkov Telescope Array (CTA) to the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016)
Authors:
The CTA Consortium,
:,
A. Abchiche,
U. Abeysekara,
Ó. Abril,
F. Acero,
B. S. Acharya,
C. Adams,
G. Agnetta,
F. Aharonian,
A. Akhperjanian,
A. Albert,
M. Alcubierre,
J. Alfaro,
R. Alfaro,
A. J. Allafort,
R. Aloisio,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
M. Anduze,
E. O. Angüner
, et al. (1387 additional authors not shown)
Abstract:
List of contributions from the Cherenkov Telescope Array (CTA) Consortium presented at the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016), July 11-15, 2016, in Heidelberg, Germany.
List of contributions from the Cherenkov Telescope Array (CTA) Consortium presented at the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016), July 11-15, 2016, in Heidelberg, Germany.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
Manufacturing and testing a thin glass mirror shell with piezoelectric active control
Authors:
D. Spiga,
M. Barbera,
A. Collura,
S. Basso,
R. Candia,
M. Civitani,
M. Di Bella,
G. Di Cicca,
U. Lo Cicero,
G. Lullo,
C. Pelliciari,
M. Riva,
B. Salmaso,
L. Sciortino,
S. Varisco
Abstract:
Optics for future X-ray telescopes will be characterized by very large aperture and focal length, and will be made of lightweight materials like glass or silicon in order to keep the total mass within acceptable limits. Optical modules based on thin slumped glass foils are being developed at various institutes, aiming at improving the angular resolution to a few arcsec HEW. Thin mirrors are prone…
▽ More
Optics for future X-ray telescopes will be characterized by very large aperture and focal length, and will be made of lightweight materials like glass or silicon in order to keep the total mass within acceptable limits. Optical modules based on thin slumped glass foils are being developed at various institutes, aiming at improving the angular resolution to a few arcsec HEW. Thin mirrors are prone to deform, so they require a careful integration to avoid deformations and even correct forming errors. On the other hand, this offers the opportunity to actively correct the residual deformation: a viable possibility to improve the mirror figure is the application of piezoelectric actuators onto the non-optical side of the mirrors, and several groups are already at work on this approach. The concept we are developing consists of actively integrating thin glass foils with piezoelectric patches, fed by voltages driven by the feedback provided by X-rays. The actuators are commercial components, while the tension signals are carried by a printed circuit obtained by photolithography, and the driving electronic is a multi-channel low power consumption voltage supply developed in-house. Finally, the shape detection and the consequent voltage signal to be provided to the piezoelectric array are determined in X-rays, in intra-focal setup at the XACT facility at INAF/OAPA. In this work, we describe the manufacturing steps to obtain a first active mirror prototype and the very first test performed in X-rays.
△ Less
Submitted 2 October, 2016;
originally announced October 2016.
-
eXTP -- enhanced X-ray Timing and Polarimetry Mission
Authors:
S. N. Zhang,
M. Feroci,
A. Santangelo,
Y. W. Dong,
H. Feng,
F. J. Lu,
K. Nandra,
Z. S. Wang,
S. Zhang,
E. Bozzo,
S. Brandt,
A. De Rosa,
L. J. Gou,
M. Hernanz,
M. van der Klis,
X. D. Li,
Y. Liu,
P. Orleanski,
G. Pareschi,
M. Pohl,
J. Poutanen,
J. L. Qu,
S. Schanne,
L. Stella,
P. Uttley
, et al. (160 additional authors not shown)
Abstract:
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time…
▽ More
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering <180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10 keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees FoV. The eXTP international consortium includes mostly major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.
△ Less
Submitted 29 July, 2016;
originally announced July 2016.
-
The new SOXS instrument for the ESO NTT
Authors:
P. Schipani,
R. Claudi,
S. Campana,
A. Baruffolo,
S. Basa,
S. Basso,
E. Cappellaro,
E. Cascone,
R. Cosentino,
F. DAlessio,
V. De Caprio,
M. Della Valle,
A. de Ugarte Postigo,
S. DOrsi,
R. Franzen,
J. Fynbo,
A. Gal-Yam,
D. Gardiol,
E. Giro,
M. Hamuy,
M. Iuzzolino,
D. Loreggia,
S. Mattila,
M. Munari,
G. Pignata
, et al. (6 additional authors not shown)
Abstract:
SOXS (Son Of X-Shooter) will be a unique spectroscopic facility for the ESO-NTT 3.5-m telescope in La Silla (Chile), able to cover the optical/NIR band (350-1750 nm). The design foresees a high-efficiency spectrograph with a resolution-slit product of ~4,500, capable of simultaneously observing the complete spectral range 350 - 1750 nm with a good sensitivity, with light imaging capabilities in th…
▽ More
SOXS (Son Of X-Shooter) will be a unique spectroscopic facility for the ESO-NTT 3.5-m telescope in La Silla (Chile), able to cover the optical/NIR band (350-1750 nm). The design foresees a high-efficiency spectrograph with a resolution-slit product of ~4,500, capable of simultaneously observing the complete spectral range 350 - 1750 nm with a good sensitivity, with light imaging capabilities in the visible band. This paper outlines the status of the project.
△ Less
Submitted 13 July, 2016;
originally announced July 2016.
-
Active shape correction of a thin glass/plastic X-ray mirror
Authors:
D. Spiga,
M. Barbera,
S. Basso,
M. Civitani,
A. Collura,
S. Dell'Agostino,
U. Lo Cicero,
G. Lullo,
C. Pelliciari,
M. Riva,
B. Salmaso,
L. Sciortino
Abstract:
Optics for future X-ray telescopes will be characterized by very large aperture and focal length, and will be made of lightweight materials like glass or plastic in order to keep the total mass within acceptable limits. Optics based on thin slumped glass foils are currently in use in the NuSTAR telescope and are being developed at various institutes like INAF/OAB, aiming at improving the angular r…
▽ More
Optics for future X-ray telescopes will be characterized by very large aperture and focal length, and will be made of lightweight materials like glass or plastic in order to keep the total mass within acceptable limits. Optics based on thin slumped glass foils are currently in use in the NuSTAR telescope and are being developed at various institutes like INAF/OAB, aiming at improving the angular resolution to a few arcsec HEW. Another possibility would be the use of thin plastic foils, being developed at SAO and the Palermo University. Even if relevant progresses in the achieved angular resolution were recently made, a viable possibility to further improve the mirror figure would be the application of piezoelectric actuators onto the non-optical side of the mirrors. In fact, thin mirrors are prone to deform, so they require a careful integration to avoid deformations and even correct forming errors. This however offers the possibility to actively correct the residual deformation. Even if other groups are already at work on this idea, we are pursuing the concept of active integration of thin glass or plastic foils with piezoelectric patches, fed by voltages driven by the feedback provided by X-rays, in intra-focal setup at the XACT facility at INAF/OAPA. In this work, we show the preliminary simulations and the first steps taken in this project.
△ Less
Submitted 4 October, 2015;
originally announced October 2015.
-
Angular resolution measurements at SPring-8 of a hard X-ray optic for the New Hard X-ray Mission
Authors:
D. Spiga,
L. Raimondi,
A. Furuzawa,
S. Basso,
R. Binda,
G. Borghi,
V. Cotroneo,
G. Grisoni,
H. Kunieda,
F. Marioni,
H. Matsumoto,
H. Mori,
T. Miyazawa,
B. Negri,
A. Orlandi,
G. Pareschi,
B. Salmaso,
G. Tagliaferri,
K. Uesugi,
G. Valsecchi,
D. Vernani
Abstract:
The realization of X-ray telescopes with imaging capabilities in the hard (> 10 keV) X-ray band requires the adoption of optics with shallow (< 0.25 deg) grazing angles to enhance the reflectivity of reflective coatings. On the other hand, to obtain large collecting area, large mirror diameters (< 350 mm) are necessary. This implies that mirrors with focal lengths >10 m shall be produced and teste…
▽ More
The realization of X-ray telescopes with imaging capabilities in the hard (> 10 keV) X-ray band requires the adoption of optics with shallow (< 0.25 deg) grazing angles to enhance the reflectivity of reflective coatings. On the other hand, to obtain large collecting area, large mirror diameters (< 350 mm) are necessary. This implies that mirrors with focal lengths >10 m shall be produced and tested. Full-illumination tests of such mirrors are usually performed with on- ground X-ray facilities, aimed at measuring their effective area and the angular resolution; however, they in general suffer from effects of the finite distance of the X-ray source, e.g. a loss of effective area for double reflection. These effects increase with the focal length of the mirror under test; hence a "partial" full-illumination measurement might not be fully representative of the in-flight performances. Indeed, a pencil beam test can be adopted to overcome this shortcoming, because a sector at a time is exposed to the X-ray flux, and the compensation of the beam divergence is achieved by tilting the optic. In this work we present the result of a hard X-ray test campaign performed at the BL20B2 beamline of the SPring-8 synchrotron radiation facility, aimed at characterizing the Point Spread Function (PSF) of a multilayer-coated Wolter-I mirror shell manufactured by Nickel electroforming. The mirror shell is a demonstrator for the NHXM hard X-ray imaging telescope (0.3 - 80 keV), with a predicted HEW (Half Energy Width) close to 20 arcsec. We show some reconstructed PSFs at monochromatic X-ray energies of 15 to 63 keV, and compare them with the PSFs computed from post-campaign metrology data, self-consistently treating profile and roughness data by means of a method based on the Fresnel diffraction theory. The modeling matches the measured PSFs accurately.
△ Less
Submitted 11 September, 2015;
originally announced September 2015.
-
Profile reconstruction of grazing-incidence X-ray mirrors from intra-focal X-ray full imaging
Authors:
D. Spiga,
S. Basso,
M. Bavdaz,
V. Burwitz,
M. Civitani,
O. Citterio,
M. Ghigo,
G. Hartner,
B. Menz,
G. Pareschi,
L. Proserpio,
B. Salmaso,
G. Tagliaferri,
E. Wille
Abstract:
The optics of a number of future X-ray telescopes will have very long focal lengths (10 - 20 m), and will consist of a number of nested/stacked thin, grazing-incidence mirrors. The optical quality characterization of a real mirror can be obtained via profile metrology, and the Point Spread Function of the mirror can be derived via one of the standard computation methods. However, in practical case…
▽ More
The optics of a number of future X-ray telescopes will have very long focal lengths (10 - 20 m), and will consist of a number of nested/stacked thin, grazing-incidence mirrors. The optical quality characterization of a real mirror can be obtained via profile metrology, and the Point Spread Function of the mirror can be derived via one of the standard computation methods. However, in practical cases it can be difficult to access the optical surfaces of densely stacked mirror shells, after they have been assembled, using the widespread metrological tools. For this reason, the assessment of the imaging resolution of a system of mirrors is better obtained via a direct, full-illumination test in X-rays. If the focus cannot be reached, an intra-focus test can be performed, and the image can be compared with the simulation results based on the metrology, if available. However, until today no quantitative information was extracted from a full-illumination, intra-focal exposure. In this work we show that, if the detector is located at an optimal distance from the mirror, the intensity variations of the intra-focal, full-illumination image in single reflection can be used to reconstruct the profile of the mirror surface, without the need of a wavefront sensor. The Point Spread Function can be subsequently computed from the reconstructed mirror shape. We show the application of this method to an intra-focal (8 m distance from mirror) test performed at PANTER on an optical module prototype made of hot-slumped glass foils with a 20 m focal length, from which we could derive an expected imaging quality near 16 arcsec HEW.
△ Less
Submitted 8 September, 2015;
originally announced September 2015.
-
CTA Contributions to the 34th International Cosmic Ray Conference (ICRC2015)
Authors:
The CTA Consortium,
:,
A. Abchiche,
U. Abeysekara,
Ó. Abril,
F. Acero,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
A. Akhperjanian,
A. Albert,
M. Alcubierre,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio
, et al. (1290 additional authors not shown)
Abstract:
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
△ Less
Submitted 11 September, 2015; v1 submitted 24 August, 2015;
originally announced August 2015.
-
Development of mirrors made of chemically tempered glass foils for future X-ray telescopes
Authors:
B. Salmaso,
M. Civitani,
B. Brizzolari,
S. Basso,
M. Ghigo,
G. Pareschi,
D. Spiga,
L. Proserpio,
Y. Suppiger
Abstract:
Thin slumped glass foils are considered good candidates for the realization of future X-ray telescopes with large effective area and high spatial resolution. However, the hot slumping process affects the glass strength, and this can be an issue during the launch of the satellite because of the high kinematical and static loads occurring during that phase. In the present work we have investigated t…
▽ More
Thin slumped glass foils are considered good candidates for the realization of future X-ray telescopes with large effective area and high spatial resolution. However, the hot slumping process affects the glass strength, and this can be an issue during the launch of the satellite because of the high kinematical and static loads occurring during that phase. In the present work we have investigated the possible use of Gorilla glass (produced by Corning), a chemical tempered glass that, thanks to its strength characteristics, would be ideal. The un-tempered glass foils were curved by means of an innovative hot slumping technique and subsequently chemically tempered. In this paper we show that the chemical tempering process applied to Gorilla glass foils does not affect the surface micro-roughness of the mirrors. On the other end, the stress introduced by the tempering process causes a reduction in the amplitude of the longitudinal profile errors with a lateral size close to the mirror length. The effect of the overall shape changes in the final resolution performance of the glass mirrors was studied by simulating the glass foils integration with our innovative approach based on glass reinforcing ribs. The preliminary tests performed so far suggest that this approach has the potential to be applied to the X-ray telescopes of the next generation.
△ Less
Submitted 11 February, 2015;
originally announced February 2015.
-
The imaging properties of the Gas Pixel Detector as a focal plane polarimeter
Authors:
S. Fabiani,
E. Costa,
E. Del Monte,
F. Muleri,
P. Soffitta,
A. Rubini,
R. Bellazzini,
A. Brez,
L. de Ruvo,
M. Minuti,
M. Pinchera,
C. Sgrò,
G. Spandre,
D. Spiga,
G. Tagliaferri,
G. Pareschi,
S. Basso,
O. Citterio,
V. Burwitz,
W. Burkert,
B. Menz,
G. Hartner
Abstract:
X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a te…
▽ More
X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a telescope, will increase the sensitivity of orders of magnitude. Moreover, since it can measure the energy, the position, the arrival time and the polarization angle of every single photon, allows to perform polarimetry of subsets of data singled out from the spectrum, the light curve or the image of source. The GPD has an intrinsic very fine imaging capability and in this work we report on the calibration campaign carried out in 2012 at the PANTER X-ray test facility of the Max-Planck-Institut für extraterrestrische Physik of Garching (Germany) in which, for the first time, we coupled it to a JET-X optics module with a focal length of 3.5 m and an angular resolution of 18 arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small mission. We derived the imaging and polarimetric performance for extended sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the XIPE configuration, discussing also possible improvements by coupling the detector with advanced optics, having finer angular resolution and larger effective area, to study with more details extended objects.
△ Less
Submitted 27 March, 2014;
originally announced March 2014.
-
Evaluation of the surface strength of glass plates shaped by hot slumping process
Authors:
L. Proserpio,
S. Basso,
F. Borsa,
O. Citterio,
M. Civitani,
M. Ghigo,
G. Pareschi,
B. Salmaso,
G. Sironi,
D. Spiga,
G. Tagliaferri,
A. D'Este,
R. Dall'Igna,
M. Silvestri,
G. Parodi,
F. Martelli,
M. Bavdaz,
E. Wille
Abstract:
The Hot Slumping Technology is under development by several research groups in the world for the realization of grazing-incidence segmented mirrors for X-ray astronomy, based on thin glass plates shaped over a mould at temperatures above the transformation point. The performed thermal cycle and related operations might have effects on the strength characteristics of the glass, with consequences on…
▽ More
The Hot Slumping Technology is under development by several research groups in the world for the realization of grazing-incidence segmented mirrors for X-ray astronomy, based on thin glass plates shaped over a mould at temperatures above the transformation point. The performed thermal cycle and related operations might have effects on the strength characteristics of the glass, with consequences on the structural design of the elemental optical modules and consecutively on the entire X-ray optic for large astronomical missions like IXO and ATHENA. The mechanical strength of glass plates after they underwent the slumping process was tested through destructive double-ring tests in the context of a study performed by the Astronomical Observatory of Brera with the collaboration of Stazione Sperimentale del Vetro and BCV Progetti. The entire study has been realized on more than 200 D263 Schott borosilicate glass specimens of dimension 100 mm x 100 mm and thickness 0.4 mm, either flat or bent at a Radius of Curvature of 1000 mm through the particular pressure assisted hot slumping process developed by INAF-OAB. The collected experimental data have been compared to non-linear FEM analyses and treated with Weibull statistic to assess the current IXO glass X-ray telescope design, in terms of survival probability, when subject to static and acoustic loads characteristic of the launch phase. The paper describes the activities performed and presents the obtained results.
△ Less
Submitted 9 July, 2014; v1 submitted 14 February, 2014;
originally announced February 2014.
-
Re-testing the JET-X Flight Module No. 2 at the PANTER facility
Authors:
Daniele Spiga,
Gianpiero Tagliaferri,
Paolo Soffitta,
Oberto Citterio,
Stefano Basso,
Ronaldo Bellazzini,
Alessandro Brez,
Wolfgang Burkert,
Vadim Burwitz,
Enrico Costa,
Luca de Ruvo,
Ettore Del Monte,
Sergio Fabiani,
Gisela Hartner,
Benedikt Menz,
Massimo Minuti,
Fabio Muleri,
Giovanni Pareschi,
Michele Pinchera,
Alda Rubini,
Carmelo Sgrò,
Gloria Spandre
Abstract:
The Joint European X-ray Telescope (JET-X) was the core instrument of the Russian Spectrum-X-gamma space observatory. It consisted of two identical soft X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured angular resolution of nearly 15 arcsec. Soon after the payload completion, the mission was cancelled and the two optical flight modules (FM) were brought to the Brera…
▽ More
The Joint European X-ray Telescope (JET-X) was the core instrument of the Russian Spectrum-X-gamma space observatory. It consisted of two identical soft X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured angular resolution of nearly 15 arcsec. Soon after the payload completion, the mission was cancelled and the two optical flight modules (FM) were brought to the Brera Astronomical Observatory where they had been manufactured. After 16 years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel Detector (GPD) with polarimetric capabilities in the focal plane of the FM2. The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In the first phase of the test campaign, we have re-tested the FM2 at PANTER to have an up-to-date characterization in terms of angular resolution and effective area, while in the second part of the test the GPD has been placed in the focal plane of the FM2. In this paper we report the results of the tests of the sole FM2, using an unpolarized X-ray source, comparing the results with the calibration done in 1996.
△ Less
Submitted 18 February, 2014; v1 submitted 9 November, 2013;
originally announced November 2013.
-
XIPE: the X-ray Imaging Polarimetry Explorer
Authors:
Paolo Soffitta,
Xavier Barcons,
Ronaldo Bellazzini,
João Braga,
Enrico Costa,
George W. Fraser,
Szymon Gburek,
Juhani Huovelin,
Giorgio Matt,
Mark Pearce,
Juri Poutanen,
Victor Reglero,
Andrea Santangelo,
Rashid A. Sunyaev,
Gianpiero Tagliaferri,
Martin Weisskopf,
Roberto Aloisio,
Elena Amato,
Primo Attiná,
Magnus Axelsson,
Luca Baldini,
Stefano Basso,
Stefano Bianchi,
Pasquale Blasi,
Johan Bregeon
, et al. (74 additional authors not shown)
Abstract:
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and wh…
▽ More
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017 but not selected. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus and two additional GPDs filled with pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 % at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil).
△ Less
Submitted 26 September, 2013;
originally announced September 2013.
-
CTA contributions to the 33rd International Cosmic Ray Conference (ICRC2013)
Authors:
The CTA Consortium,
:,
O. Abril,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
M. Ajello,
A. Akhperjanian,
M. Alcubierre,
J. Aleksic,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
E. Amato,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
E. O. Angüner,
L. A. Antonelli,
V. Antonuccio
, et al. (1082 additional authors not shown)
Abstract:
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
△ Less
Submitted 29 July, 2013; v1 submitted 8 July, 2013;
originally announced July 2013.
-
POLARIX: a pathfinder mission of X-ray polarimetry
Authors:
Enrico Costa,
Ronaldo Bellazzini,
Gianpiero Tagliaferri,
Giorgio Matt,
Andrea Argan,
Primo Attina',
Luca Baldini,
Stefano Basso,
Alessandro Brez,
Oberto Citterio,
Sergio Di Cosimo,
Vincenzo Cotroneo,
Sergio Fabiani,
Marco Feroci,
Antonella Ferri,
Luca Latronico,
Francesco Lazzarotto,
Massimo Minuti,
Ennio Morelli,
Fabio Muleri,
Lucio Nicolini,
Giovanni Pareschi,
Giuseppe Di Persio,
Michele Pinchera,
Massimiliano Razzano
, et al. (8 additional authors not shown)
Abstract:
Since the birth of X-ray astronomy, spectral, spatial and timing observation improved dramatically, procuring a wealth of information on the majority of the classes of the celestial sources. Polarimetry, instead, remained basically unprobed. X-ray polarimetry promises to provide additional information procuring two new observable quantities, the degree and the angle of polarization. POLARIX is a m…
▽ More
Since the birth of X-ray astronomy, spectral, spatial and timing observation improved dramatically, procuring a wealth of information on the majority of the classes of the celestial sources. Polarimetry, instead, remained basically unprobed. X-ray polarimetry promises to provide additional information procuring two new observable quantities, the degree and the angle of polarization. POLARIX is a mission dedicated to X-ray polarimetry. It exploits the polarimetric response of a Gas Pixel Detector, combined with position sensitivity, that, at the focus of a telescope, results in a huge increase of sensitivity. Three Gas Pixel Detectors are coupled with three X-ray optics which are the heritage of JET-X mission. POLARIX will measure time resolved X-ray polarization with an angular resolution of about 20 arcsec in a field of view of 15 arcmin $\times$ 15 arcmin and with an energy resolution of 20 % at 6 keV. The Minimum Detectable Polarization is 12 % for a source having a flux of 1 mCrab and 10^5 s of observing time. The satellite will be placed in an equatorial orbit of 505 km of altitude by a Vega launcher.The telemetry down-link station will be Malindi. The pointing of POLARIX satellite will be gyroless and it will perform a double pointing during the earth occultation of one source, so maximizing the scientific return. POLARIX data are for 75 % open to the community while 25 % + SVP (Science Verification Phase, 1 month of operation) is dedicated to a core program activity open to the contribution of associated scientists. The planned duration of the mission is one year plus three months of commissioning and SVP, suitable to perform most of the basic science within the reach of this instrument.
△ Less
Submitted 3 May, 2011;
originally announced May 2011.
-
ORIGIN: Metal Creation and Evolution from the Cosmic Dawn
Authors:
J. W. den Herder,
L. Piro,
T. Ohashi,
C. Kouveliotou,
D. H. Hartmann,
J. S. Kaastra,
L. Amati,
M. I. Andersen,
M. Arnaud,
J-L. Attéia,
S. Bandler,
M. Barbera,
X. Barcons,
S. Barthelmy,
S. Basa,
S. Basso,
M. Boer,
E. Branchini,
G. Branduardi-Raymont,
S. Borgani,
A. Boyarsky,
G. Brunetti,
C. Budtz-Jorgensen,
D. Burrows,
N. Butler
, et al. (134 additional authors not shown)
Abstract:
ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of metal creation from the epoch of cosmic dawn. Using high-spectral resolution in the soft X-ray band, ORIGIN will be able to identify the physical conditions of all abundant elements between C and Ni to red-shifts of z=10, and beyond. The mission will answer questions such as: When were the first metals created? How does the…
▽ More
ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of metal creation from the epoch of cosmic dawn. Using high-spectral resolution in the soft X-ray band, ORIGIN will be able to identify the physical conditions of all abundant elements between C and Ni to red-shifts of z=10, and beyond. The mission will answer questions such as: When were the first metals created? How does the cosmic metal content evolve? Where do most of the metals reside in the Universe? What is the role of metals in structure formation and evolution? To reach out to the early Universe ORIGIN will use Gamma-Ray Bursts (GRBs) to study their local environments in their host galaxies. This requires the capability to slew the satellite in less than a minute to the GRB location. By studying the chemical composition and properties of clusters of galaxies we can extend the range of exploration to lower redshifts (z ~ 0.2). For this task we need a high-resolution spectral imaging instrument with a large field of view. Using the same instrument, we can also study the so far only partially detected baryons in the Warm-Hot Intergalactic Medium (WHIM). The less dense part of the WHIM will be studied using absorption lines at low redshift in the spectra for GRBs.
△ Less
Submitted 15 April, 2011; v1 submitted 11 April, 2011;
originally announced April 2011.
-
Analytical computation of the off-axis Effective Area of grazing incidence X-ray mirrors
Authors:
D. Spiga,
V. Cotroneo,
S. Basso,
P. Conconi
Abstract:
Focusing mirrors for X-ray telescopes in grazing incidence, introduced in the 70s, are characterized in terms of their performance by their imaging quality and effective area, which in turn determines their sensitivity. Even though the on-axis effective area is assumed in general to characterize the collecting power of an X-ray optic, the telescope capability of imaging extended X-ray sources is…
▽ More
Focusing mirrors for X-ray telescopes in grazing incidence, introduced in the 70s, are characterized in terms of their performance by their imaging quality and effective area, which in turn determines their sensitivity. Even though the on-axis effective area is assumed in general to characterize the collecting power of an X-ray optic, the telescope capability of imaging extended X-ray sources is also determined by the variation in its effective area with the off-axis angle. [...] The complex task of designing optics for future X-ray telescopes entails detailed computations of both imaging quality and effective area on- and off-axis. Because of their apparent complexity, both aspects have been, so far, treated by using ray-tracing routines aimed at simulating the interaction of X-ray photons with the reflecting surfaces of a given focusing system. Although this approach has been widely exploited and proven to be effective, it would also be attractive to regard the same problem from an analytical viewpoint, to assess an optical design of an X-ray optical module with a simpler calculation than a ray-tracing routine. [...] We have developed useful analytical formulae for the off-axis effective area of a double-reflection mirror in the double cone approximation, requiring only an integration and the standard routines to calculate the X-ray coating reflectivity for a given incidence angle. [...] Algebraic expressions are provided for the mirror geometric area, as a function of the off-axis angle. Finally, the results of the analytical computations presented here are validated by comparison with the corresponding predictions of a ray-tracing code.
△ Less
Submitted 4 September, 2009; v1 submitted 29 June, 2009;
originally announced June 2009.
-
Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study
Authors:
G. Tagliaferri,
S. Basso,
G. Borghi,
W. Burkert,
O. Citterio,
M. Civitani,
P. Conconi,
V. Cotroneo,
M. Freyberg,
D. Garoli,
P. Gorenstein,
G. Hartner,
V. Mattarello,
A. Orlandi,
G. Pareschi,
S. Romaine,
D. Spiga,
G. Valsecchi,
D. Vernani
Abstract:
Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical develop…
▽ More
Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission; ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV; iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.
△ Less
Submitted 13 March, 2009;
originally announced March 2009.
-
X-ray polarimetry on-board HXMT
Authors:
Paolo Soffitta,
Ronaldo Bellazzini,
Gianpiero Tagliaferri,
Enrico Costa,
Giovanni Pareschi,
Stefano Basso,
Vincenzo Cotroneo,
Massimo Frutti,
Francesco Lazzarotto,
Fabio Muleri,
Alda Rubini,
Gloria Spandre,
Alessandro Brez,
Luca Baldini,
Jean Bregeon,
Massimo Minuti,
Giorgio Matt,
Filippo Frontera
Abstract:
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fractio…
▽ More
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter (EXP2, Efficient X-ray Photoelectric Polarimeter) in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources, the proposed instrument can represent a breakthrough in X-ray Polarimetry.
△ Less
Submitted 15 October, 2008;
originally announced October 2008.
-
XIAO: a soft X-ray telescope for the SVOM Mission
Authors:
S. Mereghetti,
A. De Luca,
M. Fiorini,
N. La Palombara,
A. Tiengo,
M. Uslenghi,
G. Vianello,
G. Villa,
A. Zambra,
A. Moretti,
S. Basso,
S. Campana,
P. Conconi,
V. Cotroneo,
S. Covino,
G. Ghirlanda,
G. Ghisellini,
G. Pareschi,
G. Tagliaferri,
M. Trifoglio,
L. Amati,
F. Gianotti,
L. Stella,
A. Antonelli,
B. Cordier
, et al. (1 additional authors not shown)
Abstract:
The study of Gamma-ray bursts (GRBs) is a key field to expand our understanding of several astrophysical and cosmological phenomena. SVOM is a Chinese-French Mission which will permit to detect and rapidly locate GRBs, in particular those at high redshift, and to study their multiwavelength emission. The SVOM satellite, to be launched in 2013, will carry wide field instruments operating in the X…
▽ More
The study of Gamma-ray bursts (GRBs) is a key field to expand our understanding of several astrophysical and cosmological phenomena. SVOM is a Chinese-French Mission which will permit to detect and rapidly locate GRBs, in particular those at high redshift, and to study their multiwavelength emission. The SVOM satellite, to be launched in 2013, will carry wide field instruments operating in the X/gamma-ray band and narrow field optical and soft X-ray telescopes. Here we describe a small soft X-ray telescope (XIAO) proposed as an Italian contribution to the SVOM mission. Thanks to a grazing incidence X-ray telescope with effective area of ~120 cm^2 and a short focal length, coupled to a very compact, low noise, fast read out CCD camera, XIAO can substantially contribute to the overall SVOM capabilities for both GRB and non-GRB science.
△ Less
Submitted 6 July, 2008;
originally announced July 2008.
-
An X-ray Polarimeter for HXMT Mission
Authors:
Enrico Costa,
Ronaldo Bellazzini,
Gianpiero Tagliaferri,
Luca Baldini,
Stefano Basso,
Johan Bregeon,
Alessandro Brez,
Oberto Citterio,
Vincenzo Cotroneo,
Filippo Frontera,
Massimo Frutti,
Giorgio Matt,
Massimo Minuti,
Fabio Muleri,
Giovanni Pareschi,
Giuseppe Cesare Perola,
Alda Rubini,
Carmelo Sgro',
Paolo Soffitta,
Gloria Spandre
Abstract:
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fractio…
▽ More
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources the proposed instrument can represent a breakthrough in X-ray Polarimetry.
△ Less
Submitted 25 September, 2007;
originally announced September 2007.
-
Active and passive shielding design optimization and technical solutions for deep sensitivity hard X-ray focusing telescopes
Authors:
G. Malaguti,
G. Pareschi,
P. Ferrando,
E. Caroli,
G. Di Cocco,
L. Foschini,
S. Basso,
S. Del Sordo,
F. Fiore,
A. Bonati,
G. Lesci,
J. M. Poulsen,
F. Monzani,
A. Stevoli,
B. Negri
Abstract:
The 10-100 keV region of the electromagnetic spectrum contains the potential for a dramatic improvement in our understanding of a number of key problems in high energy astrophysics. A deep inspection of the universe in this band is on the other hand still lacking because of the demanding sensitivity (fraction of microCrab in the 20-40 keV for 1 Ms integration time) and imaging (~15" angular reso…
▽ More
The 10-100 keV region of the electromagnetic spectrum contains the potential for a dramatic improvement in our understanding of a number of key problems in high energy astrophysics. A deep inspection of the universe in this band is on the other hand still lacking because of the demanding sensitivity (fraction of microCrab in the 20-40 keV for 1 Ms integration time) and imaging (~15" angular resolution) requirements. The mission ideas currently being proposed are based on long focal length, grazing incidence, multi-layer optics, coupled with focal plane detectors with few hundreds microns spatial resolution capability. The required large focal lengths, ranging between 8 and 50 m, can be realized by means of extendable optical benches (as foreseen e.g. for the HEXIT-SAT, NEXT and NuSTAR missions) or formation flight scenarios (e.g. Simbol-X and XEUS). While the final telescope design will require a detailed trade-off analysis between all the relevant parameters (focal length, plate scale value, angular resolution, field of view, detector size, and sensitivity degradation due to detector dead area and telescope vignetting), extreme attention must be dedicated to the background minimization. In this respect, key issues are represented by the passive baffling system, which in case of large focal lengths requires particular design assessments, and by the active/passive shielding geometries and materials. In this work, the result of a study of the expected background for a hard X-ray telescope is presented, and its implication on the required sensitivity, together with the possible implementation design concepts for active and passive shielding in the framework of future satellite missions, are discussed.
△ Less
Submitted 1 September, 2005;
originally announced September 2005.