Schedule
Schedule
Schedule
PLUMBING FIXTURE SCHEDULE PLUMBING FIXTURE SCHEDULE PLUMBING FIXTURE SUPPLIES AND TRIM
MINIMUM ROUGH-IN SIZES MINIMUM ROUGH-IN SIZES FIXTURE MANUFACTURER STRAINER P-TRAP SIZE ANGLE STOP AND SUPPLY RISER * * mO*
PLAN MARK
WASTE & VENT DRAIN CW HW
DESCRIPTION PLAN MARK
WASTE & VENT DRAIN
DESCRIPTION LAVATORY McGUIRE HD155A 8872 1-1/4" LFBV2165-LK, 1/2" I.P.S. X 3/8" O.D. M2 5
WATER CLOSET
WC-1
4" 2" 4" 1-1/2" --- AMERICAN STANDARD No. 3451.001 WHITE V.C. ELONGATED SIPHON JET
FLOOR MOUNT (1.28 GPF) BOWL WITH TOP SPUD. THERMOSTATIC --- --- ---
CW
1/2"
HW
1/2" POWERS MODEL: 270-LF ADJUSTABLE POINT-OF-USE LEAD FREE
DRINKING
FOUNTAIN
McGUIRE HD155A 8872 1-1/4" LFBV2165-LK, 1/2" I.P.S. X 3/8" O.D. Q 5
7 7
FLOOR MOUNT MIXING VALVE THERMOSTATIC MIXING VALVE, ASSE 1070 WITH INLET CHECK STOPS
FLUSH VALVE SLOAN ROYAL No.111-1.28 FLUSH VALVE LOW CONSUMPTION (MANUAL)
VALVE. POLISHED CHROME FINISH.
TMV-1 TO LIMIT HOT WATER TEMPERATURE. SET TEMPERATURE AT 110°.
PROVIDE WITH MOUNTING BRACKET. SINK McGUIRE 152N 8912 1-1/2" LFBV2165-LK, 1/2" I.P.S. X 3/8" O.D. ILII
2
7 2 QL 2 I-
NOTE: DOUBLE
4 4 COMPARTMENT
ACCESSORIES BEMIS MODEL: 2155SSCT ELONGATED, HEAVY-DUTY, WHITE, OPEN FRONT FLOOR DRAIN 3" 2" 3" --- --- ZURN No. ZN-415 CAST IRON DRAIN WITH 6" DIAMETER TYPE 'B' 4
TOILET SEAT, LESS COVER WITH SELF-SUSTAINING STAINLESS STEEL CHECK
HINGE. PROVIDE ZURN OR EQUAL FLOOR MOUNTED CARRIER. FOR FULL
DESCRIPTION REFER TO PROJECT SPECIFICATIONS.
FD-1 STRAINER AND 1/2" IPS TRAP PRIMER CONNECTION. FOR FLOOR
DRAIN BODY POURED IN CONCRETE SLAB PROVIDE ZURN Z1023 TRAP
PRIMER EXTENSION.
1. STRAINERS SHALL BE HEAVY CAST BRASS CHROME PLATED WITH MATCHING GRID TYPE STRAINER, WITH OR WITHOUT OVERFLOW AS REQUIRED. 17 GAUGE
SEAMLESS BRASS TAILPIECE OF LENGTH DETERMINED BY INSTALLATION REQUIREMENTS. PROVIDE COMPLETE WITH WASHERS AND BRASS LOCKNUT.
WC
TP-1
I2 3
3 3
WCO
-~ 4 6
2. P-TRAPS SHALL BE 17 GAUGE SEAMLESS CHROME-PLATED BRASS, ADJUSTABLE TYPE. PROVIDE COMPLETE WITH CLEANOUT PLUG, CHROME-PLATED BRASS SLIP 8
FLOOR DRAIN 3" 2" 3" --- --- ZURN No. ZN-415 CAST IRON DRAIN WITH 7" DIAMETER TYPE 'E' 3
FD-2 STRAINER, TRAP PRIMER CONNECTION AND 4" DIAMETER FUNNEL NUTS, WALL BEND, AND WROUGHT BRASS ESCUTCHEON OF DEPTH DETERMINED BY INSTALLATION REQUIREMENTS. v-i
WATER CLOSET
WC-2
ADA
4" 2" 4" 1-1/2" --- AMERICAN STANDARD No. 3043.001. SAME AS ABOVE EXCEPT WITH TRIM AS
REQUIRED FOR ADA USE.
GRATE. FOR FLOOR DRAIN BODY POURED IN CONCRETE SLAB
PROVIDE ZURN Z1023 TRAP PRIMER EXTENSION. 3. ANGLE STOPS SHALL BE LEAD-FREE COMMERCIAL PATTERN CHROME-PLATED BRASS, QUARTER-TURN BALL TYPE WITH LOOSE KEY HANDLES. PROVIDE
COMPLETE WITH CHROME-PLATED COPPER SUPPLY RISERS AND WROUGHT BRASS ESCUTCHEON OF DEPTH DETERMINED BY INSTALLATION REQUIREMENTS.
-D 1 1 1
2
CL 7 SHOWER
HEAD
DISTRIBUTION UNIT
1/2"
DESCRIPTION REFER TO PROJECT SPECIFICATIONS, REFER TO ARCHITECTS SUPPLIED. ALL EXPOSED PIPING SHALL BE CHROME PLATED AND WHERE REQUIRED
PLANS FOR MOUNTING HEIGHT. CONCEALED SUPPLY TUBING SHALL BE 1/2" TYPE "K" SOFT COPPER. A. ALL WORK, METHODS AND INSTALLATIONS INVOLVED IN THE PLUMBING DESIGN SHALL BE IN A. MOUNTING HEIGHT ELEVATION OF ALL WALL HUNG OR COUNTER MOUNTED 4
8
ACCORDANCE WITH THE PREVAILING BUILDING CODESAND INSPECTION REGULATIONS AND ALL FIXTURES SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS PRIOR MIXING VALVE
TRAP PRIMER --- --- --- 1/2" --- PRECISION PLUMBING PRODUCTS, INC. No. PO-500 AUTOMATIC
LAVATORY
L-1
WALL MOUNT - ADA
2" 2" 1-1/4" 3/4" 3/4" AMERICAN STANDARD No. 0355.012 "LUCERNE" WALL HUNG WHITE VC
LAVATORY WITH FRONT OVERFLOW, DRILLED FOR CONCEALED ARM AND
WITH 8" HOLES PUNCHED
TP-2 PRESSURE DROP TRAP PRIMER VALVE. INSTALL CONCEALED IN
ACCESSIBLE LOCATION, BEHIND APPROVED ACCESS PANEL OR
EXPOSED IN MECHANICAL EQUIPMENT AREAS WITH TRAP PRIMER
B.
OTHER OFFICIALS HAVING JURISDICTION.
OWNER'S MOST RECENT STANDARDS AND REQUIREMENTS FOR CONSTRUCTION. ALL WORK SHALL COMPONENTACCESSORIES PROVIDED UNDER SEPARATE DIVISIONS AND
FAUCET
1/2"TW (90°)
1 Th±Jj
3
9' 3
HOSE BIBB --- --- 1/2" --- CHICAGO FAUCETS No. 998-RCF SILL FAUCET WITH NON-REMOVABLE
PROOF WRIST BLADE HANDLES HB-2 (MECHANICAL VACUUM BREAKER AND LOOSE KEY OPERATING HANDLE. MOUNTING C. COORDINATE ROUTING OF PIPING IN CEILING SPACES WITH MECHANICAL AND ELECTRICAL
ROOMS) HEIGHT FOR 36" A.F.F. IN MECHANICAL ROOMS. EQUIPMENT, DUCTWORK AND CONDUIT. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS C. CONTRACTOR SHALL REFER TO SHOP DRAWINGS OF EQUIPMENT TO BE
1 1
ACCESSORIES REFER TO PLUMBING SUPPLIES AND TRIM SCHEDULE. PROVIDE ZURN OR PRIOR TO INSTALLING AN ALTERNATE PIPING PLAN. SUPPLIED FOR FINAL COORDINATION OF ALL ROUGH-IN OPENINGS BEFORE DRINKING FLOOR DRAINS SHOWER
EQUAL FLOOR MOUNTED CONCEALED ARM CARRIER, REFER TO ARCHITECTS BEGINNING WORK. FOUNTAIN TRAP PRIMERS
HOSE BIBB --- --- 1/2" --- ZURN NO. 1330 RECESSED STAINLESS STEEL WALL BOX WITH COLD D. DO NOT ROUGH-IN FOR FIXTURES FROM THESE DRAWINGS. REFER TO LATEST ARCHITECTURAL (TP-2)
PLANS FOR MOUNTING HEIGHTS.
HB-1 (TOILET WATER WHEEL HANDLE VALVE, INTEGRAL STOP, VB AND HINGED DRAWINGS FOR DIMENSIONED LOCATIONS. D. ALL FIXTURE AND EQUIPMENT STUB-OUTS SHALL BE PROVIDED WITH A STOP
PROVIDE TMV-1 SET TEMPERATURE TO 90°.
ROOMS) LOCKING COVER STAMPED 'WATER' INSTALL FLUSH AND RIGID TO VALVE. ALL FIXTURE STOPS SHALL BE SOLID BRASS, LOOSE KEY OPERATED,
* *
(TOILET ROOM FITTING) FINISHED WALL AND SEALED WATERTIGHT. E. ALL PLUMBING FIXTURE AND DEVICE LOCATIONS AND MOUNTING HEIGHTS SHALL BE COORDINATED CHROME PLATED (WHERE EXPOSED), AND FITTED TIGHT TO CHROME PLATED
LAVATORY 2" 2" 1-1/4" 3/4" 3/4" AMERICAN STANDARD MODEL: 9482.000 UNDERMOUNT WHITE V.C. IN ADVANCE WITH CASEWORK, MILLWORK, ETC. BRASS WALL ESCUTCHEON PLATES. SUPPLY RISERS SHALL BE STAINLESS STEEL 5
L-2
(DROP-IN)
LAVATORY WITH REAR OVERFLOW AND FAUCET HOLES DRILLED ON 8"
CENTER FAUCET HOLES
WALL HYDRANT
WH-1
--- --- --- 3/4" --- ZURN NO. Z-1300 RECESSED NON-FREEZE BRONZE ALL BOX,
ANTI-SIPHON HYDRANT, WITH LOOSE KEY OPERATOR AND POLISHED
NICKEL BRONZE LOCKING COVER. INSTALL WITH FACE FLUSH AND
F. COORDINATE FIXTURE AND EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS WITH
E.
FLEXIBLE CONNECTORS.
ALL P-TRAPS WITHIN THE BUILDING, ABOVE GRADE AND EXPOSED TO INSPECTION
C- 5 c
LATEST ARCHITECTURAL DRAWINGS, SPECIFICATIONS, AND MANUFACTURER RECOMMENDATIONS
FAUCET CHICAGO No. 404-1000ABCP CENTER SET FAUCET WITH VANDAL PROOF
WRIST BLADE HANDLES
SQUARE TO FINISHED WALL. SECURE WITH WALL CLAMP AND
SETSCREW. PROVIDE EXTENSION AS REQUIRED TO PLACE VALVE
PRIOR TO ANY ROUGH-INS. SHALL BE C.P. ADJUSTABLE, CAST BRASS WITH CLEANOUT PLUG.PROVIDE CAST
BRASS SLIP NUTS AND WASHERS, 17 GAGE SEAMLESS TUBULAR BRASS DRAIN TO Q-- 7
F--i y
7
SEAT IN HEATED ROOM SPACE. G. PROVIDE CLEANOUTS, POINT OF USE WATER HEATERS, WATER FILTERS, ETC. IN ACCESSIBLE, BUT WALL AND WALL FLANGE. PROVIDE MCGUIRE NO. 8872C, 1-1/4" P-TRAP FOR ALL II 2
NOT IMMEDIATELY VISIBLE LOCATIONS. REFER TO AND COORDINATE WITH ARCHITECTURAL LAVATORIES AND SIMILAR FIXTURES PROVIDE MCGUIRE NO. 8912C, 1-1/2" P-TRAP DISPOSER Il-s
ACCESSORIES REFER TO PLUMBING SUPPLIES AND TRIM SCHEDULE. PROVIDE ZURN OR
EQUAL FLOOR MOUNTED CONCEALED ARM CARRIER, REFER TO ARCHITEC...
WALL BOX --- --- --- 3/4" --- GUY GRAY NO. MIB1HAAB 1/2"x1/2" O.D. TUBE ICE MAKER WITH H.
DRAWINGS FOR DIMENSIONS AND DETAILS OF SINK SKIRTS, ADA PANELS, AND MILLWORK.
6
(7 4
H
FOR FREE STANDING REFRIGERATOR WITH ICE MAKER. INSTALL BOX WINDOW SILLS. PROVIDE OFFSETS IN PIPING AS REQUIRED.
AT 54" A.F.F.
ID-1 I F----]
FAUCET CHICAGO NO. 201-AE35-317ABCP (1.5 GPM)SWING SPOUT FAUCET WITH J. ALL VALVES, EQUIPMENT, AND OPERABLE APPURTENANCES SHALL BE LOCATED FREE FROM H. ALL HANDICAPPED ACCESSIBLE FIXTURES INDICATED WITH SHALL BE PROVIDED DISHWASHER 1
LT-1 1
0 / -D
BRASS LEVER HANDLES AND SWING SPOUT OBSTRUCTIONS FOR FULL OPERABILITY AND MAINTENANCE ACCESS. OF APPROVED TYPES AND WITH REQUIRED CONTROLS AND INSTALLED TO 3
FOR UNDER COUNTER REFRIGERATOR ICE MAKER: INSTALL BOX AT 18" DRAIN
HEIGHTS AND CLEARANCES, AS PRESCRIBED BY AMERICANS WITH DISABILITIES
A.F.F. WORK ROOM 3 MOP SINK
K. ALL PIPING PROVIDED WITHIN RETURN AIR CEILING SPACES SHALL BE PLENUM RATED. ACT (ADA). FIXTURES SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL
ACCESSIBILITY CODE REQUIREMENTS. REFER TO ARCHITECTURAL DRAWINGS SINK (FLOOR MOUNTED)
ACCESSORIES REFER TO PLUMBING SUPPLIES AND TRIM SCHEDULE. REFER TO
ARCHITECTS PLANS FOR MOUNTING HEIGHTS. FOR COFFEE MACHINE: INSTALL BOX AT 24" A.F.F. BELOW COUNTER OR L. INSTALLATIONS WHICH DO NOT ADHERE TO THE REQUIREMENTS INDICATED WITHIN THE CONTRACT FOR DIMENSIONED MOUNTING HEIGHTS AND SPECIFIED CLEARANCE
PROVIDE TMV-1 SET TEMPERATURE TO 90°. ABOVE COUNTER BACKSPLASH; COORDINATE WITH ARCHITECT FOR DOCUMENTS OR WHICH ARE INCORECT DUE TO LACK OF FIELD COORDINATION, ETC. SHALL BE REQUIREMENTS. PROVIDE FIXTURES WITH DEPTHS AT MAXIMUM PERMITTED AND
EXACT LOCATION. CORRECTED SOLELY AT THE CONTRACTOR'S EXPENSE, WITH NO EXCEPTIONS. AVAILABLE FOR INTENDED FIXTURE USE.
ELECTRIC DRINKING 2" 2" 1-1/4" 3/4" --- ELKAY No. LVRC8WSK BARRIER-FREE, LEAD FREE, FILTERED WATER BOTTLE
FOUNTAIN FILLING STATION, WALL MOUNTED SINGLE COOLER, 8.8 GPH CAPACITY FOR ICE/COFFEE MAKER PROVIDE WITH CUNO NO. AP717 FILTER M. PROVIDE BALL VALVE SHUT-OFFS ON ALL DOMESTIC WATER BRANCH LINES WITHIN 24”OF THE I. ALL WHEELCHAIR LAVATORY AND SINK PIPING WHERE EXPOSED SHALL BE
EDF-1 COOLED TO 50° F WITH 80° F AMBIENT TEMP. PROVIDE ZURN OR EQUAL BRACKETED TO WALL AND WATTS SD-3 IN-LINE BACKFLOW
PREVENTER.
CORRESPONDING MAIN, WHETHER INDICATED ON PLAN DRAWINGS OR NOT. INSULATED. PROVIDEOFFSET DRAIN FITTINGS WHERE REQUIRED TO PROVIDE
MINIMUM CLEARANCES.
0* *
ADA FLOOR MOUNTED PLATE TYPE CARRIER AND TRAP AND SUPPLY AS NOTED
BELOW. PROVIDE WITH ALL STAINLESS STEEL CABINET. N. ALL DOMESTIC WATER AND SANITARY VENT LINES SERVING FIXTURE GROUPS SHALL HAVE A FULL
SIZE HEADER THAT RUNS THE LENGTH OF THE CHASE/WALL SPACE FOR CONNECTION TO ALL J. ALL SINKS FOR HANDICAPPED USE SHALL BE STAMPED WITH DRAIN OUTLETAT
FIXTURES. REFER TO PLANS FOR HEADER SIZES, WHICH MAY BE INDICATED BY THE VERTICAL DROP REAR OF BOWL.
ELECTRICAL 1/5 HP, 4.0 FL. AMPS. WIRED FOR POWER AS SCHEDULED ON ELECTRICAL
REQUIREMENTS DRAWINGS. BACKFLOW
PREVENTOR
BFP-1
--- --- --- --- --- WATTS No.909-S-LF REDUCED PRESS. PRINCIPLE DOUBLE CHECK
VALVE WITH INTERMEDIATE ATMOSPHERIC VENT. PROVIDE AIR GAP
AND FULL SIZE INDIRECT DRAIN PIPED TO FLOOR DRAIN. INSTALL ON
DOWN OR RISE UP FROMTHE CHASE. REFER TO PLUMBING FIXTURE SCHEDULE FOR INDIVIDUAL
FIXTURE ROUGH-IN CONNECTION SIZES TO HEADER. K. PLUMBING FIXTURES SHALL BE OF WATER CONSERVATION TYPE IN ACCORDANCE
WITH PLUMBING CODEREQUIREMENTS FOR WATER SAVING PERFORMANCE.
MANIFOLD
tl LL
ACCESSORIES REFER TO PLUMBING SUPPLY AND TRIM SCHEDULE. PROVIDE ZURN OR PIPE STAND AT 42" AFF WITH CLEARANCE FOR SERVICE AND PIPING O. VENT HEADERS WITHIN WALLS AND CHASES FOR MULTIPLE FIXTURES SHALL BE PROVIDED AT NO KEYED NOTES - TYPICAL RISER DIAGRAM DETAILS:
EQUAL FLOOR MOUNTED CONCEALED ARM CARRIER, REFER TO BRACKETED TO WALL. PROVIDE SHUT OFF VALVE & FULL SIZE LESS THAN 42”ABOVE FINISHED FLOOR. L. ORIENT ADA WATER CLOSET FLUSH VALVE WITH OPERATOR ON WIDE SIDE OF
ENCLOSURE. (NOT ALL RISERS USED IN EVERY PROJECT.)
ARCHITECTS PLANS FOR MOUNTING HEIGHTS. STRAINER ON INLET AND SHUT OFF VALVE ON OUTLET RISER. TEST
SHOWER 2" 2" 2" 3/4" 3/4" ACORN MODEL 538ADA-F/2.0-LFS-LGB-LRD-MSH-SB VALVE SHALL BE
AND CERTIFY PER AWWA C-511 P. FOR EACH FIXTURE INTENDED TO DRAIN INDIRECTLY, PROVIDE THE CODE REQUIRED INDIRECT
WASTE PIPE (AND TRAP OR TRAP AND VENT, AS NECESSARY) TO ROUTE THE DRAIN LINE TO THE M. SEAL ALL SPACES BETWEEN PLUMBING FIXTURES AND MOUNTING SURFACES 01 REFER TO PLUMBING FIXTURE SCHEDULE FOR SOIL OR
WASTE ROUGH-IN PIPE SIZE. MINIMUM SOIL OR WASTE ISSUE
NEAREST APPROVED INDIRECT WASTE RECEPTOR WITHOUT POSING A TRIP HAZARD. IN FINISHED WITH WHITE LATEX CAULKWIPED SMOOTH AND FLUSH WITH FIXTURE.
SH-1 COMBINATION THERMOSTATIC AND PRESSURE BALANCING MIXING VALVE WALL CLEANOUT --- --- --- --- --- JAY R SMITH MODEL: 4435-NB-U DURO-COATED CAST IRON CLEANOUT DRAIN LINE SIZE (EXCEPT AS NOTED) FOR THIS FIXTURE.
AREAS ALL SUCH DRAIN LINES SHALL BE CHROME PLATED CAST BRASS.
ADA (ACORN MODEL NO. SV16-LVR), CHECK STOPS, MULTI-STREAM SHOWER WCO WITH COUNTER-SUNK GASKET, WATERTIGHT THREADED PLUG AND N. FLOOR DRAINS SHALL BE INSTALLED AT LOW POINTS OF UNIFORMLY SLOPED 06-01-2023 ISSUE FOR PERMIT
HEAD, 2.0 GPM FLOW CONTROL, DIVERTER VALVE, HAND HELD FLEX SHOWER
WITH V.B. LESS QUICK-DISCONNECT.
SQUARE SMOOTH NICKEL BRONZE ACCESS COVER WITH VANDAL Q. PROVIDE AN ACCESSIBLE WALL CLEANOUT AT THE BASE OF EACH SANITARY RISER, WHETHER FLOOR. CONTRACTOR SHALL FIELD COORDINATE WITH STRUCTURAL TO INSURE 02 REFER TO PLUMBING FIXTURE SCHEDULE FOR SANITARY
VENT ROUGH-IN PIPE SIZE. MINIMUM SANITARY VENT
06-28-2023 ISSUE FOR BID
PROOF SCREWS. INDICATED ON PLAN DRAWINGS OR NOT. FLOORS ARE SLOPED UNIFORMLY ACROSS ENTIRE TOILET ROOMS OR OVER AS
BRANCH SIZE (EXCEPT AS NOTED) FOR THIS FIXTURE
WIDE AN AREA AS PRACTICAL FOR OPEN AREA FLOOR DRAINS.CONVEX FLOOR
HOT WATER TO BE SET TO 120 DEGREES FAHRENHEIT MAX FLOOR CLEANOUT --- --- --- --- --- ZURN No.ZN-1400 CAST IRON CLEANOUT WITH COUNTER-SUNK PLUG SLOPE IN THE IMMEDIATE VICINITY OF THE FLOOR DRAIN IS NOT ACCEPTABLE.
R. FOR FLOOR MOUNTED WATER HEATERS AND SIMILAR EQUIPMENT, PROVIDE A RECTANGULAR
FCO AND ROUND SCORIATED TOP FOR GENERAL PURPOSE AREAS.
PROVIDE VARIATION AS REQUIRED FOR FLOOR FINISH WHERE
SHAPED 4”THICK CONCRETE HOUSEKEEPING PAD EXTENDING TO BEYOND THE LIMITS OF THE 03 REFER TO PLUMBING FIXTURE SCHEDULE FOR FIXTURE
DRAIN ROUGH-IN PIPE SIZE. MINIMUM FIXTURE DRAIN AND
EQUIPMENT FOOTPRINT.
ACCESSORIES ZURN ZS880-60 STAINLESS STEEL LINEAR SHOWER TRENCH DRAIN, INSTALLED. SEE ARCHITECT DWG'S FOR FLOOR TYPES. TRAP SIZE (EXCEPT AS NOTED) FOR THIS FIXTURE
VERTICAL ADJUSTING ANCHORING SUPPORT LEGS, ANTI-PONDING
GRADE CLEANOUT --- --- --- --- --- ZURN No. Z-1402 DURO-COATED CAST IRON CLEANOUT WITH S. COORDINATE ROUTING OF PIPING BELOW SLAB ON GRADE WITH COLUMN FOOTINGS, GRADE
V-SHAPED CHANNEL W/ NO-HUB CENTER OUTLET. AND MINIMUM 4 P.S.F.
LEAD, OR 40 MIL. VINYL SHOWER PAN OR AS DESCRIBED BY ARCHITECTURAL GCO WATERTIGHT COUNTER-SUNK PLUG AND SCORIATED SECURED TOP BEAMS, UNDERGROUND PLUMBING AND ELECTRICAL UTILITIES, AND ANY OTHER
SUB-SURFACE BUILDING ELEMENTS. MAKE ADJUSTMENTS AS REQUIRED.
04 REFER TO PLUMBING FIXTURE SCHEDULE FOR WATER PIPING
ROUGH-IN PIPE SIZE. MINIMUM WATER SUPPLY BRANCH
PLANS. WITH FRAME. INSTALL IN 18"x18"x6" THICK CONCRETE PAD. SIZE (EXCEPT AS NOTED) FOR THIS FIXTURE.
* - REFER TO DRAWINGS FOR SIZING. T. COORDINATE IN FIELD TO ENSURE NO LESS THAN 6 INCHES OF EARTHEN COVER FROM TOPS OF
MOP SINK
MS-1
3" 2" --- 3/4" 3/4" STERN WILLIAMS No. MTB-2424-SS-BP FLOOR MOUNTED 24 X 24 X 10
TERRAZZO MOLDED BASIN WITH S.S. CAPS AND SPLASH CATCHER PANELS.
GENERAL NOTES:
1. FOR ALL SUPPLY STOPS AND TRIM REFER TO THE PLUMBING FIXTURE SUPPLIES AND TRIM SCHEDULE.
PIPES TO BOTTOMS OF GRADE BEAMS, FOUNDATIONWALLS, OR SIMILAR ELEMENTS. IN LOCATIONS 05 WATER HAMMER ARRESTOR INLET; REFER TO ARRESTOR
SCHEDULE FOR SIZE. LOCATION SHOWN HERE FOR No. DATE REVISION
2. FOR MOUNTING HEIGHTS OF INDIVIDUAL FIXTURES, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION.
WHERE SUCH MINIMUM COVER CANNOT BE PROVIDED DUE TO LIMITATIONS OF AVAILABLE PIPE
INVERTS, PROVIDE CASTIRON SLEEVES THROUGH THE FOUNDATION ELEMENTS. SLEEVES SHALL BE FIRE PROTECTION GENERAL NOTES 0* INDIVIDUAL FIXTURE WILL VARY WHERE INCLUDED AS PART
OF PLUMBING CHASE BATTERY OF PIPING. REFER TO RISER
FAUCET CHICAGO No. 897-CP SERVICE SINK FAUCET WITH VACUUM BREAKER HOSE 3. CONTRACTOR TO COORDINATE LOCATION OF DRAINS AND FLOOR SINKS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS. NO SMALLER THAN TWO PIPE SIZES GREATER THAN THE PIPE PASSING THROUGH THE GRADE DIAGRAMS FOR MANIFOLD LOCATIONS. ARRANGE ALL WATER
BEAM/FOUNDATION WALL. COORDINATE WITH AND ADHERE TO ALL RELATED REQUIREMENTS LINES TO GRAVITY DRAIN.
END SPOUT.
INDICATED BY THE STRUCTURAL ENGINEER. A. THE BUILDING SHALL BE FULLY FIRE SPRINKLERED. THE SCOPE OF WORK
INCLUDES THE INSTALLATION OF SPRINKLER HEADS, PIPE, FITTINGS,HANGERS, *1->
-- I
ACCESSORIES STERN WILLIAMS No. T-40 MOP BRACKET, STERN WILLIAMS No. T-35 BRACKET
AND HOSE.
U. PROVIDE ISOLATION VALVES FOR ALL BRANCHES OFF DOMESTIC WATER MAINS. ALL PLUMBING
SYSTEM VALVES SHALL BE INSTALLED IN ACCESSIBLE CEILING SPACES.
AND ACCESSORIES. 0 6
WALL CLEANOUTS SHALL BE PROVIDED AT ALL END OF
BATTERY OR END OF BRANCH LINE FIXTURES AND WHERE 9990 Richmond Avenue
REQUIRED BY PLUMBING CODE OFFICIALS TO ASSURE South Building, Suite 300
B. FIRE SPRINKLER SYSTEM SHALL PROVIDE COMPLETE AUTOMATIC PROTECTION COMPLETE ACCESS TO ALL PORTIONS OF DRAIN. Houston, Texas 77042
V. WHERE CEILING IS NOT ACCESSIBLE, OR SPACE IS CONFLICTING, VALVES SHALL BE INSTALLED IN AND COVERAGE REQUIRED BY THE LOCAL, STATE, JURISDICTIONAL,
713.914.0888 p 713.914.0886 f
PARTITIONS OR PIPE CHASES. PROVIDE APPROVED PAINTED STEEL HINGED ACCESS PANELS IN GOVERNMENTAL AGENCIES AND NFPA 13 (PREVAILING EDITION). THE WORK SANITARY VENT PIPES SHALL CONTINUE TO CEILING OR
PLUMBING FIXTURE SCHEDULE CONT. LOCATIONS PRE-APPROVED BY THE ARCHITECT. PROVIDE MARKINGS ON CEILING TILES ON
LOCATIONS OF ISOLATION VALVES.
SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: VALVE SUPERVISORY
SWITCHES, FLOW SWITCHES AND COORDINATION WITH THE FIRE ALARM
07 HEADER TOGETHER AT MINIMUM 42" ABOVE FINISHED FLOOR.
TBPE Firm Registration No. 2234
PLAN MARK
MINIMUM ROUGH-IN SIZES
WASTE & VENT CW HW
DESCRIPTION W. COORDINATE IN FIELD TO ENSURE THAT ALL INDIRECT WASTE RECEPTORS ARE PROPERLY POSITIONED
SYSTEM.
08 TRAP PRIMER LINE; SEE PLUMBING DETAILS SHEET.
EXTEND AND CONNECT TO FLOOR DRAIN TRAP AS SHOWN.
I DBR Project Number 220177.000 1
FDC (2-PORT) N/A N/A 4" N/AHPOTTER ROEMER No. 5751 TWO-WAY INLET POLISHED CHROME FLUSH CONNECTION. PROVIDED KNOX
WITH REGARD TO THE FIXTURES AND/OR EQUIPMENT THEY ARE INTENDED TO SERVE. MAKE
ADJUSTMENTS AS REQUIRED. INSTALLATIONS WHERE SUPPORT FEET/CASTERS FOR APPLIANCES,
C. FIRE SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED BY A STATE
LICENSED FIRE PROTECTION CONTRACTOR IN ACCORDANCE WITH ALL LOCAL, AIR GAP FITTING; PROVIDE WHERE REQUIRED BY CODE. IELF=L
BM CB ZN JL I
LOCKING CAPS WITH 2-1/2" SWIVEL GUARDS, CAPS SHALL BE POLISHED CHROME PLATED BRASS WITH EQUIPMENT, COUNTERTOPS, ETC., REST UPON DRAIN STRAINERS, GRATES, OR RIMS SHALL BE STATE, JURISDICTIONAL, GOVERNMENTAL AGENCIES AND NFPA 13 (PREVAILING 09
TRIM AND LETTERING CONSISTENT WITH SYSTEM TYPE AND SERVICE (DRY STANDPIPE). MINIMUM SIZE
LINE SHALL BE 4".
CONSIDERED UNACCEPTABLE. SUCH INSTALLATIONS SHALL BE CORRECTED SOLELY AT THE
CONTRACTOR'S
EDITION). SPRINKLER SYSTEM MUST ALSO BE APPROVED BY OWNER AND
OWNER'S FIRE INSURANCE UNDERWRITER.
martinez
MARCH ITECTS M
EXPENSE.
NOTE: THIS EQUIPMENT SHALL BE D. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER HEAD For.-
FDV N/A N/A N/A N/A FIRE DEPARTMENT HOSE VALVE AT STANDPIPE. CAST BRASS ANGLE TYPE VALVE WITH INSIDE SCREW
RISING STEM, INTERNAL PARTS OF BRASS AND STAINLESS STEEL, RED ALUMINUM WHEEL HANDLE. 2-1/2”
PROVIDED BY THE FIRE SPRINKLER
CONTRACTOR, NOT THE PLUMBER.
X. COORDINATE IN FIELD TO ENSURE THAT ALL DRAINS TO BE LOCATED IN AREAS OF SLOPED OR
DEPRESSED SLABS ARE PROPERLY POSITIONED FOR THE INTENDED DRAINAGE. MAKE ADJUSTMENTS AS
LOCATIONS WITH CEILING TILES AND ARCHITECTURAL FINISHES. ALL SPRINKLER
HEADS SHALL BE INSTALLED IN CENTER OF CEILING TILES REGARDLESS OF ANY
WATER HAMMER ARRESTOR SCHEDULE
oeo ,A YAl
MALE HOSE THREADED OUTLET, N.S.T. PATTERN OR AS DIRECTED BY OWNER. PROVIDE COMPLETE REQUIRED. NECESSITY TO INSTALL ADDITIONAL HEADS TO ACCOMPLISH UNIFORM
APPEARANCES OF THE COMPLETED INSTALLATION BY THIS REQUIREMENT.
0 P.D.I.
* SYMBOL
FIXTURE
UNITS
SIZE Martinez Architect, LP
900 Rockmead, Suite 250
WITH 2-1/2” X 1-1/2” FEMALE TO MALE REDUCER, CAP AND CHAIN. ALSO PROVIDE ADDITIONAL CAP WITH
CHAIN TO FIT 2-1/2” OUTLET. POTTER ROEMER SERIES 4065 WITH APPURTENANCES. ENSURE
PLACEMENT AND ORIENTATION TO ALLOW FOR FULL OPERABILITY.
Y. NORMALLY CLOSED (NC) VALVE(S) SHOULD BE FIELD INSTALLED AS CLOSE AS POSSIBLE TO NORMAL PATH
OF HOT WATER TRAVEL AS SHOWN ON PLAN. THE REMAINING LEG OF BY-PASS PIPING WILL BE IN DIRECT
CONTRACTOR SHALL MAKE ADJUSTMENTS AS NECESSARY DURING SHOP
DRAWING PROCESS TO MEET ARCHITECTURAL REVIEW REQUIREMENTS WHILE
0A 1-11 1/2" NPT Houston, Texas 77339
281.346.7371
COMMUNICATION WITH THE CIRCULATING WATER. STILL ENSURING COMPLETE AND COMPLIANT COVERAGE. 0B 12-32 3/4" NPT SEAL:
Z. NORMALLY OPEN (NO) VALVE(S) ON HOT WATER LINES SHALL BE INSTALLED AS SHOWN ON THE PLAN. E. COMPLETE SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED BY THE
CONTRACTOR FOR OWNER, OWNER'S FIRE INSURANCE UNDERWRITER, AND FIRE
0C 33-60 1" NPT
F. SPRINKLER SYSTEM SHALL CONTAIN NO VALVES DOWNSTREAM OF CONTROL 0E 114-154 1 1/2" NPT
ELECTRIC WATER HEATER SCHEDULE STATION. 0F 155-330 2" NPT
ELECTRICAL REQUIREMENTS G. CONTRACTOR TO DESIGN SPRINKLER SYSTEM AS REQUIRED TO ACCOMMODATE ANTHNY5. JASPAL.
HEATING GPH STANDBY WATER HAMMER ARRRESTORS SHALL COMPLY WITH 2015 IPC,
CW HW FIXTURES, PARTITIONS, SOFFITS, FURR DOWNS, CEILING HEIGHTS, CHAPTER 6, SECTION 604.9.DAS.
PLAN MARK MANUFACTURER MODEL # TYPE FUEL GALLONS LOAD
INLET OUTLET
RECOVERY @ LOSS VOLTS OBSTRUCTIONS, ETC.
S95728
(BTU/hr) 80⁰ TEMP RISE (%/hour) PHASE kW AMPS PIPING RISER DIAGRAMS/TYPICAL RISER DETAILS ILLUSTRATE WATER
(V)
H. THE SPRINKLER SYSTEM SHALL BE FULLY CHARGED AND OPERATIONAL WHEN HAMMER ARRESTORS FOR FIXTURE WATER PIPE OPENINGS. ALL
ELECTRIC WATER HEATER CUSTOM STORAGE TANK ELECTRIC 65 41,969 1-1/2" 1-1/2" 62 0.87 480 3 12.3 14.8 THE CONTRACTOR IS OFF THE SITE. ARRESTORS SHALL BE SIZED AS INDICATED ON DRAWINGS OR IN
ACCORDANCE WITH THIS SCHEDULE, WHICHEVER PLACES THE MOST
EWH-1 A.O. SMITH Xi SERIES STRINGENT REQUIREMENT.
DATE 06-28-2023
I. REFER TO OWNER'S CRITERIA/CONSTRUCTION REQUIREMENTS FOR ADDITIONAL
DESIGN ENGINEER
INFORMATION.
PROVIDE ARRESTORS IN ACCORDANCE WITH THE REQUIREMENTS OF
NOTES: PLUMBING DRAINAGE INSTITUTE (PDI) STANDARD PDI-WH-201. THE
J. REFER TO ARCHITECTURAL CODE ANALYSIS FOR ANY SPECIAL REQUIREMENTS.
1. PROVIDE ASME TEMPERATURE AND PRESSURE RELIEF VALVE, AND DIAL THERMOMETER IN HW OUTLET PIPING USE OF AIR CHAMBERS SHALL NOT BE ACCEPTABLE. a SUGA R
-N
2. FOR POWER AS SCHEDULED ON ELECTRICAL DRAWINGS, VERIFY WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING EQUIPMENT. K. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL MAKE AND PAY /0,1-O F LX
LA
WATER HAMMER ARRESTORS SHALL HAVE LIFETIME WARRANTY AND X\
ao
CI T Y
ELECTRICAL REQUIREMENTS FOR ALL TESTS AS MAY BE REQUIRED BY THE AUTHORITIES HAVING
SHALL BE CERTIFIED BY THE MANUFACTURER AS SUITABLE FOR
JURISDICTION AND SHALL CORRECT ANY DEFECTS INDICATED BY TESTS TO THE
ND
SATISFACTION OF THE AUTHORITIES.
INSTALLATION WITHOUT A REQUIREMENT FOR ACCESS PANELS.
NINNMA 14
7r
PLAN MARK MANUFACTURER MODEL # DESCRIPTION VOLTS NONETHELESS, ACCESS PANELS SHALL BE PROVIDED IF AND AS
PHASE kW HP REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ).
(V) L. ENSURE TO LOCATE INSPECTOR'S TEST CONNECTION AT THE END OF THE MOST \*Is
REMOTE BRANCH LINE FOR EACH SYSTEM. T EX A S
CIRCULATION PUMP ALL STAINLESS STEEL FLANGED PUMP, 1/25 HP WIRED FOR POWER AS SCHEDULED ON ELECTRICAL DRAWINGS AND FITTED
J,
CP-1 (EWH-1) WITH REMOTE HEAT SENSING AQUASTAT CONTROLLER. CONTROLLED BY ELECTRICAL CONTRACTOR, DESIGNED AT 15 FT HEAD M. PROVIDE AND ADJUST ALL TAMPER SWITCHES AND WATER FLOW SWITCHES.
CITY OF SUGAR LAND, TEXAS
GRUNDFOS MAGNA3 115 1 85 W 0.04 ENGINEERING DEPARTMENT
LOSS.
CONSTRUCTION PLANS FOR:
TIME SWITCH ELECTROMECHANICAL 24 HOUR TIME SWITCH POWERED BY A SELF STARTING SYNCHRONOUS MOTOR. INSTALL ON WALL CITY OF SUGAR LAND, TEXAS
INTERMATIC EH-10 120 1 -- --
TS-1 ADJACENT TO CIRCULATING PUMP. COORDINATE WITH ELECTRICAL AND PROVIDE FOR POWER AS SCHEDULED ON ELECTRICA... PUBLIC SAFETY TRAINING FACILITY
THERMAL EXPANSION ASME THERMAL EXPANSION ABSORBERS, SAFETY RELIEF VALVE, MAXIMUM WORKING PRESSURE 150 PSIG, TOTAL VOLUME 4.4 One Circle Dr. #C, Sugar Land, TX 77498
THERM-X-TROL GALLONS.
TANK AMTROL -- -- -- --
MODEL ST-5-C
ET-1 PLUMBING SCHEDULES