QUESTION BANK FOR AIR-CONDITIONED COACHES
1. Define Refrigeration?
Refrigeration is the process of lowering the temperature of a body below that of its surroundings.
2. Define Air-Conditioning?
The process of treating the air so as to control simultaneously its temperature, humidity,
cleanliness and distribution to meet the requirements of the conditioned space.
3. What is the unit of refrigeration/Air conditioning?
One ton of refrigeration is latent heat required to melt a ton of ice at 32 degrees F in 24
hours. One short ton = 2000 lbs. Latent heat of fusion is 144 BTU/lb OR A ton of
refrigeration is the rate of heat removal equal to;
In FPS system
1 ton of refrigeration = 2000 x144 = 2,88,000 B.T. U/24 hours
= 12,000 B.T. U/hour
= 200 B.T.U /min.
The rate of cooling has been designated as a ton of refrigeration. It is measurement of the rate of
transfer.
In MKS system
One ton of refrigeration = 72000 k cal/24 hours
= 3000 k cal / hour
= 50 k cal/min
Compression :
Refrigerant is drawn from evaporator in dry vapour state by suction strokes of the compressor. In
compression stroke, the refrigerant temperature and pressure being increases to the condensation
cooling level.
Condensation:
High temperature refrigerant is received in condenser unit where the heat is rejected with the help
of water and natural air of condenser fan, which results refrigerant returns to liquid state.
2
Expansion :
After condensation, refrigerant is stored in receiver in – liquid state till it needed by expansion
valve. Expansion valve is provided just before evaporator unit; the refrigerant passes through this
valve and enters this evaporator unit with low temperature.
Evaporation:
Expanded/spreaded low pressure refrigerant enters into the evaporator unit or refrigerated
space and converted in to vapour form and thus refrigeration cycle is completed. At this stage
refrigerant observes the heat through circulating air with the help of blower fan.
The refrigerant in gas form is sucked into the suction side of the compressor and
compressed to high pressure. From the compressor, the gas goes through a condenser which
removes the sensible heat generate in the gas due to compression as well as, the latent heat
and the gas liquefies. The liquid gas passing through an expansion valve into the evaporator
is expanded to gas absorbing the latent heat in the process, thus cooling the cooling coil.
The gas having taken up its latent heat in properly designed cooling coil is now dry and is
again sucked into the compressor to continue on another cycle.
REFRIGERATION CYCLE
2.1 Refrigerants are heat carrying medium which during their cycle in the refrigerant system
absorb heat at a low temperature level and discard the heat so absorbed at a higher level. The
refrigerants common used are R-12, R-22, R-134a etc.
The refrigerant have boiling points much below ordinary room temperature, so they exists as
gas and are only held in the liquid state by keeping them under pressure.
Refrigeration can be produced by allowing a liquid refrigerant from high pressure vessel to
pass and boil inside a coil or evaporator. The latent heat needed for the boiling is taken from
the surrounding space of the evaporator, thereby cooling the space. After passing from
evaporator, the refrigerant is reclaimed with the help of compressor. The compressor
compressed the vapour to the pressure corresponding to a saturation temperature, higher than
the temperature of naturally available air or water. The compressor also circulates the
refrigerant through the system.
The refrigeration cycle thus comprise of:
Absorption of heat by the evaporation of a liquid refrigerant in the evaporator at a
controlled lower pressure.
Raising the pressure of the low pressure vapour coming from the evaporator by the use of
the compressor.
Removal of heat from the high vapour in the condenser so as to liquidity or condense the
vapour and
3
By the use of the throttling device, reducing the pressure of high pressure liquid (from the
condenser) to the level of pressure needed in the evaporator.
11. What are temperature setting recommended by RDSO in case of electronic thermostat?
As per the RDSO recommendations the temperature in the coach should be with electronic
thermostat
Plant cut in temperature in summer - 25°C
Plant cut out temperature in summer - 23°C
Plant cut in temperature in winter - 19°C
Plant cut out temperature in summer - 21°C
4
12. Explain about Electronic thermostat used in AC coaches?
The unit is intended to provide ON/OFF control of the refrigeration plant/heater by sensing the
temperature of the air at the return air grill.
The unit except the sensor shall be mounted in AC control panel, which is in the non-air
conditioned space, and the sensor shall be mounted at the return air grill of the air conditioned
space. The unit shall be designed for continuous operation.
The unit shall give output signals through the contacts of the relays at the final stage of it to
switch on either the heating control circuit or the cooling (refrigeration plant) control circuit. The
operating point of the relay corresponds to the heater shall be capable of being selected between
17 & 21 deg. C. The operating point of the relay corresponds to the refrigeration plant shall be
capable of being selected between 22 & 26 deg. C. The desired settings for the heating and
cooling shall be obtainable in the following steps. The temperature setting are given in deg. C
Cooling Heating
Medium - 25 19
High - 23 21
The drift on the selected settings (due to variation in ambient temperature, input voltage
fluctuations, ageing of the components and error on account of any other reason) shall not be
more than +/- 0.2 deg. C. The differential between the cut-in and cut-out operation of the
Heater/Refrigeration plant shall be between 0.5 deg. C minimum and 1.0 deg. C maximum.
At final stage of the unit there shall be two relays one for the heating control circuit to switch on
the heater through its contactor and the other for the cooling circuit to switch on the refrigeration
plant through its contractor. Each relay shall have one N/O and one N/C contact. The relay used
for heater circuit shall get energized when the temperature at the sensor is less than the set value
for heating and the relay that used for refrigeration plant shall get energize when the temperature
at the sensor is more than the set value for cooling. The contacts of these relays shall be rated for
and inductive load of 3 amp at 110V ac PWM power supply.
The unit shall be capable to work from 110V ac +/- 10% PWM supply with maximum ripple
content of 15%. The design shall take care of the series connections and the surges that may be
present due to switching ON/OFF of these loads controller shall be design in such a manner so
that relay operation is chattering free.
The unit shall be provided with reverse polarity protection against inadvertent wrong connections
of the polarity of the power supply.
The unit shall be designed to take care of an over voltage of 200V for one minute at the power
supply terminals.
13. List out parts of RMPU AC coach?
Hermetically sealed compressor, condenser, condenser fan motor, capillary tube, Accumulator,
Evaporator, Blower motor, Fresh air and Return air filters, 25 KW Alternator, Rectifier- Regulator
units, 1100 AH battery, pre-cooling rectifier units, 25 KVA inverters.
5
14. Compare between RMPU and Under slung AC unit?
Comparison of Roof Mounted Ac, System with Conventional Under frame hung A.C. system.
6
18. Draw the tube light circuit diagram?
20. Rating of the fuse used for phase supply & field supply in Regulator of AC Coaches.
Phase supply fuse for 25KW Regulator – 160 Amperes.
Field supply fuse for 25KW Regulator – 6 Amperes.
21. What is the capacity of cells used in AC Coaches?
Incorrect setting of low- Compressor cycling on low Reset low pressure switch
pressure side of pressure pressure switch. differential.
switch.
Low refrigerant charge Compressor cycling on low Check system for leaks, repair
pressure switch. leaks and add refrigerant.
Dirty or plugged air filters. Less cooling frosting on cooling Clean or replace air filters.
coil & suffocation in AC
compartment.
7
23. Action to be taken if compressor runs continuously.
Excessive load High dry-bulb or wet- Check for excessive fresh air, infiltration.
bulb temperature in
conditioned area.
Air or non Higher than normal Purge system, after drenching receiver with
condensable gases in head pressure. chilled water/ Ice, then purge from purging
the system. valve, intermittently until visible gas is
found escaping.
Low refrigerant Lower than normal Check system for leaks; repair and add
charge. suction pressure. refrigerant.
8
24. Reason for low suction pressure.
f) Too much oil in the system. Drain the oil from evaporator
and condenser.
Clean or defrost.
g) Evaporator dirty or frosted. Check unloading mechanism.
h) Compressor not unloading. Correct low pressure as in
i) Discharge pressure low. symptom 5
Inadequate Cooling
Check thermostats. If mercury column has broken, replace it by a new one from the spare. If
spare is not available, move the control switch(46), in any other position (Low, Medium or
High) as may be the case.
Check whether accelerating contactors (13 & 13a) in the case of old AC control panel have
made contacts. If they are not closed, adjust the motor control relay (23) such that the above
contactors get close.
Check High pressure gauge reading. If the HP reading is more than 180 psi, open the wheel
valve located in the cubicle for a short while for admitting water for cooling the condenser
9
tubes and fins and close the valve after HP reading indicates 150 psi. This operation has to
be repeated whenever the HP shoots up to 180 psi.
Check the condition of the blown fuses, replace the fuses of the corresponding circuit. If the
fuse fails again, do not replace again, but note down in the log sheet for further action at the
base station.
Unsolder the suction and discharge lines and disconnect the electrical wiring from the
compressor.
Remove the compressor and clean the cylinder using carbon tetrachloride (CTC) with the
help of circulating pump. It is advised that CTC flushing should not be done with
compressor in circuit.
Install a new compressor, and resolder the suction and discharge lines. Make the
electrical connections. Use high quality silver based copper solder with minimum 40%
silver.
Test for leakage under 30 kg.cm2 pressure using Nitrogen/Carbon dioxide gas cylinder
fitted with a two stage pressure regulator.
Create a vacuum of 50 micron for 15 minutes with the help of two stage rotary vacuum
pump to extract the moisture from inside of the refrigeration system.
Charge the quantity of refrigerant gas (R 22) as per recommendation of the manufacturer.
Charging slub-tube on the compressor should be 1/4” OD and of heavy gauge. Pinch off
charging tube nearest to the compressor body so that it remains as short as possible.
Longer stub tube can break due to vibrations. Place slight amount of solder at the pinch
point for strengthening.
27. Describe procedure for carrying out leak test.
Leak Test: Disconnect the low pressure cut-out and pressure-charge the system with dry nitrogen
at 24 kg/cm2 (350 psig) and check for leakage with soap solution.
Evacuation : After leak test, connect the system on both the low & high side to a vacuum pump
for at least 4 hours and pull up to 200 microns (29.9 inch Mercury Column) of vacuum. Use
electronic or tube type gauge, for checking vacuum.
Charging: Now charge the system with 2.85 kg R-22 gas. This can be done by pulling a vacuum
on a 5 kg gas cylinder and charging it with 2.85 kg R-22 gas by weight. (Weight the cylinder
before and after filling gas. The difference should be 2.85 kg in weight). Check with halogen leak
detector after charging the system.
10
28. What is the normal current drawn by RMPU AC plant?
29. AC Plant not working in auto mode. What action you are going to take.
Shift Rotary - Switch RSW-4 from "AUTO' to "COOL-ING or I-EATING manual mode.
The AC Unit will now operate continuously thus by-passing the Thermostat.
During manual operation thermostat goes out of the control circuit and machine will run
continuously in the selected mode of operation. In case of excessive cooling, the compressor will
switch off from low pressure cut-out and in case of excessive heating, the heater will
switch off from the safety thermostat. The ACCI should switch ON /OFF the plants by
monitoring the temperature inside the coach with a thermometer.
S. No RMPU UNDERSLUNG
1 Compressor Motor, Condenser DC Motors are used which
motors, Blower motors are 3- works on 110 V DC
phase AC Induction Motors
2 Sealed type compressor is used Compressor is open type
3 Uses 4 compressors per coach. Uses only 2 compressors per
Hence Capacity can be varied coach. Hence capacity can be
11
from 25 to 100% varied from 50 to 100%
4 The compressor condenser The compressors condensers
evaporator and motors are all and its motors are sunder slung
assembled in one package unit and
situated on the roof.
5 Requires inverter for running the AC Do not requires inverters
plant
6 Uses refrigerant R-22, Uses R-12 approximately 15
approximately 3 Kg/plant Kg per plant
7. Hermitically sealed system and Service valves and pressure
hence No pressure gauges, Valves gauges and hand set of valves
etc., are used
8 Uses all 3-phase AC Contactors Use of DC Contactors
and relays
9 The expansion device used is Capillary tube is used
Thermostatic expansion valve
10 WRA is used WRA is not required as water
tank itself is situated on roof.
11 The plant can be pre cooled by The pre cooling of AC Coach is
connecting direct 3-phase supply done by using pre cooling
from outside source with the help of transformer-rectifier unit
change over switch.
32. What are the AC system presently being used in our Railways and mention the feature
of each type and where they are used.
Two types of AC system are being used Viz., RMPU fitted AC Coaches and Under slung
conventional AC Coaches. Both these coaches employed Vapour compression system for
refrigeration.
RMPU: 1) This is hermitically sealed system with no fittings or openings and used 3-phase
AC Motors. Hence less maintenance
UNDERSLUNG: The compressor used is open type which can be easily be attended in case
of repairs. The compressor moor and compressor are both separate units. Defective motor
will not have any effect on the compressor. The system is easy to understand because of
provision of pressure gauges. The refrigerant used is R12 approximately 15 kgs.
33. What are the refrigerants generally used in Air conditioning system. What are the
required properties of refrigerant?
Refrigerant – 12 and 22 are used in under slung conventional AC Coaches. And RMPU AC
Coaches respectively.
12
Recently Railways has introduced use of R-134 A environment friendly refrigerant and some
of the RMPU coaches have been converted into R-134 A refrigerant.
REQUIRED PROPERTIES:
35. What are the different types of AC coaches presently in use, explain theca system in
coach in brief.
Two types of AC system are being used Viz., RMPU fitted AC Coaches and Under slung
conventional AC Coaches. Both these coaches employed Vapour compression system for
refrigeration.
RMPU: 1) This is hermitically sealed system with no fittings or openings and used 3-phase
AC Motors. Hence less maintenance
UNDERSLUNG: The compressor used is open type which can be easily be attended in case
of repairs. The compressor moor and compressor are both separate units. Defective motor
13
will not have any effect on the compressor. The system is easy to understand because of
provision of pressure gauges. The refrigerant used is R12 approximately 15 kgs.
Also
1. Self generating AC coaches: - In these AC coaches each coach is equipped with its own
generating equipment like 3-phase Alternator and a set of battery to cater to the requirement
of total electrical load of the coach. It is also equipped with a Pre-cooling transformer-
Rectifier unit for taking shore supply.
2. End on generation AC coaches: - In trains like Rajdhani express & Shatabdi express the
coaches depend on the power supply from Power cars. The rake of the train is provided with a
power car having two nos of Diesel generators, one will be working and the other is standby.
This power car is placed at the end of the rake formation. The supply is fed to all the AC
coaches with the help of inter vehicle couplers.
a) Refrigerator
Refrigerators operates on the Vapour compression system having hermitically sealed
compressor mounted at the base of the cabinet. Refrigerant used is R-22 or 134A. Expansion
valve used is capillary tube. The evaporator piping is fastened round and brazed to the freezer
box. The condenser tube is placed over a single metal sheet for dissipation of heat. The top
space is freezer unit. and the rest of the cabinet interior gets cooled by convection currents of
air set up by freezer unit.
b) Water cooler: - Water cooler is a machine working on refrigeration system for cooling
water for drinking purpose. The refrigeration system is same which is utilized in air-
conditioning, refrigerators, etc. Generally two types of water coolers are used i.e.,
Instantaneous water coolers and storage type water coolers. In addition to the above two types
there are also storage-cum-instantaneous type also. The drinking water having temperature
between 10 degree C to 13 degree C is preferred.
c) Window type AC units: - These are completely self contained units, with the compressor,
condenser, evaporator, refrigerant piping and air filter, all assembled in a very compact
assembly. The window units are usually of ½ to 2 tons capacity and fitted with 230 volts
motor. The refrigerant is controlled with the capillary system. The unit is so designed that it
can be mounted on the window with small bracket from outside.
d) Air filter in ac system: Air filters are used to maintain cleanliness / dustproof. There are
mainly two types of air filters. Viz., Return air filter is to remove any dust present in AC
room/Coach and fresh air filter is used to filter fresh air for dust etc.,
e) Evaporator in refrigerator system: This constitutes the cooling unit, in which the liquid
refrigerant under low pressure evaporates and in doing so, it takes away its quota of latent
heat, there by cooling the medium surrounding the cooling coil.
f) Dry and Wet bulb temperature: Dry bulb temperature is the temperature of air as
measured by an ordinary thermometer.
14
Wet bulb temperature is the temperature of air as measured by an ordinary thermometer,
whose glass bulb is covered by a thin cotton sleeve soaked in water.
g) Condenser: It is intended for cooling the hot gas and liquefying it under pressure. It may
be air cooled or water cooled
h) Sealed compressor of AC unit: The motor and the compressor unit is housed in one
casing and completely sealed. The suction and discharge piping is brazed as no valves are
used , the chances of leakage is eliminated.
40. What will happen if the AC plant capacity is insufficient for load?
If the AC plant is insufficient for the load the desired temperature will not be attained in the
room. The AC plant will run continuously under vapor pressure rises considerably
overloading the compressor. The condensation of the refrigir3nt will not takes place in the
condenser.
15
Visual inspection of the coach proper fitment of equipments
Ensure the refrigerant pipes are properly clamped
Suction pipe for proper lagging
Check control panel and ensure that proper fuses are provided
Check contactors, relay and switches for correct sequential operations
Ensure the time delay in operation of contactors feeding compressors
Check heaters for correct operation
Check hooter for roper operation
Start the plant and check condenser motor, compressor motor, blower moor for
any abnormalities
Check the current drawn by the motors and compare with its rated current.
44. What are the Precautions to be taken for prevention of fires on AC coaches as per
RDSO code of practice RDSO/PE/O/0008-2005 Rev.O?
As per the RDSO code of practice RDSO/PE/O/0008-2005 REV.O the following are the measures
to be adopted for prevention of fires on AC coaches:
i. The air-conditioned coaches are to be provided with elastomeric copper cables if the size is more
than 10 sq.mm. in case of old coaches.
ii. The air-conditioned coaches are to be provided with PVC cooper cables if the size is less than 10
sq.mm. in case of old coaches
iii. For new AC coaches E-Beam irradiated thin walled elastomeric cables are to be used.
iv. The number of joints and junction boxes should be minimum.
v. Correct size of cables is to be provided for different circuits as per load.
vi. All the cables other than branch cables shall be secured to the coach structure by cleats located at
an interval not exceeding 500 mm.
vii. All the cables other than branch cables either side of bend and near all end connections, extra
cleats are to be provided not exceed a distance of 150 mm.
viii. The edges of the groove for holding the cables in the two halves of the cleat shall be suitably
chamfered to avoid pinching of cable insulation.
ix. Branch cables are to be secured by PVC insulated clips. These clips shall be attached to the coach
body by screws.
x. PVC/FRP Cleats with non-inflammable properties only shall be used.
xi. Wherever cables pass through holes, orifices, slits, apertures etc. with sharp metal edges, such
opening shall be provided with fire retardant PVC grommets grade 6.
xii. The cables should be terminated in the junction boxes, terminal boards etc. with lugs.
xiii. The cables should be not have any intermediate joints and should be terminated in junction boxes,
terminal boards.
xiv. Laptop/mobile charging points should not be used for Radio, electric shaver or any other
appliances.
xv. Locking and securing arrangement for the doors and covers of electrical control/power cubicle
and terminal boards should be ensured to prevent unauthorized access to the live parts of electrical
equipment.
xvi. There should not be earth leakage one either positive or negative cables.
xvii. All the electrical fittings both on super structure and on under fame shall be mounted directly on
the coach body and shall not be electrically insulated.
xviii. All the electrical equipments above 110V shall be individually provided with earthing shunts
between equipment body and coach body.
xix. The clearance between live part and coach body should be 10 mm and 4 mm between parts of
opposite polarities for 110V system.
xx. The insulating fire retardant low-tension (FRLT) tape should only be used in the coaches.
xxi. Coaches, poor joints should not be allowed.
16
xxii. The IR value should not be less than 2 mega ohms for 110V, 190V, 230V when measured with
500V megger and 3 mega ohms for 415V circuits when measured with 1000V megger.
xxiii. The rewiring of coach should be done after 12 years. However it should not exceed 15 years even
if the wiring is good.
xxiv. The battery boxes with LMLA batteries shall be provided with FRP trays at the bottom of the
battery box to avoid corrosion of battery box due to spilling of acid. The box shall be provided
with ventilating grills and drain pipe to permit the flow of outside air over the cells and to allow
spilled acid and water to drain out.
xxv. The battery box shall have minimum 150 mm clearance at the top of the battery for maintenance
of cells.
xxvi. The battery box should be painted with two coats of acid resistance paint to protect against
corrosion from battery acid.
xxvii. Correct size of fuses and MCBs to be maintained to blow/trip in case of abnormality
xxviii. It should be ensured that the vane relay should work properly.
xxix. It should be ensured that the OVP should work properly.
xxx. Fans, berth lights, step lights, tail lights, and side light fittings to be provided with connecters for
feeding supply to them.
xxxi. Connectors used in should be made of tough non-ignitable moulding material or rigid PVC.
45. Describe briefly the equipment used in Railway air conditioning coaches.
Compressor: It has two fold functions. It removes Vapour from the evaporator at a rate,
which will permit steady state conditions of temperature and pressure in the evaporator. It
discharges the Vapour at a pressure and temperature high enough to permit heat rejection
along a descending temperature gradient to the cooling water or air of the condenser
Condenser: It is intended for cooling the hot gas and liquefying under pressure. It may be air
cooled or water cooled.
Expansion valve: Is function is to control and regulate the rate of flow of the liquid
refrigerant under high pressure and allow it into the evaporator under low pressure.
Evaporator: This constitutes the cooling unit, in which the liquid refrigerant under low
pressure evaporates and in doing so, it takes its quota of latent heat, there by cooling the
medium surrounding the cooling coil.
Alternator: 25 KW alternators are used for RMPU coaches and 18 KW for under slung
coaches. These are brushless alternators generates 3-phase AC supply
Rectifier regulator unit: His is used to rectify Ac out put of the alternator to DC supply It
provides DC supply to the field of the alternator. The DC output voltage and current is
maintained within set limits by regulating the DC supply to the field.
Battery: For RMPU coach 56 no.s of VRLA cells of 1100 Ah are provided and 56 no.s of
800 AHR lead acid cells are used for Under slung coaches.
Maintenance depots should be check and adjust the tension during the first 3 consecutive trips and
every 2 months thereafter. Too much tension, shortens belt life and also bearing life. Too little
tension allows belt to sli0 and generate heat thereby reducing life.
Check alternator and axle pulley grooves with limit gauge or template after every 3 months.
Worn-out side-wall or sharp objects on the grooves may result in short life of V belts.
Replace the full set of old belts with new belts of same make, grade and batch,
Check condition of bearings, improper bearings may lead to heat generation which would
reduce the belt life.
17
Store belts in a cool, dry, well ventilated place away from sunlight or any other sources of
heat, oils, greases or corrosive fumes.
V belts may be hung loosely or laid flat but should never be squeezed into respective
spaces. Belts shall not be kept in a heavily bent or piled condition.
Avoid wherever possible, tying V belts tightly with string.
Use belts within 2 years from the date of manufacturing, as age and storage condition may
alter the belt length. In case of bulk procurement, deliveries can be staggered in quarterly
installments.
For easy understanding of KEL 25 KW alternator/rectifier regulator circuit diagram, was divided
into five sub circuits. They are
1. Power supply circuit
2. Field circuit
3. Voltage control circuit
4. Current control circuit
5. Over voltage Protection Circuit
18
1. Power supply circuit: This circuit consists of 3 phase alternator(ALT) fuse F1,3 phase bridge
rectifier.(PR). Capacitor bank (C1,C2,C3) and current transformers (CTI to CT3). Three phase
AC supply (13,14,15 terminals UVW) produced by alternator is fed to 3 phase bridge rectifier
through fuse F1. The bridge is protected against voltage surges by 6 numbers of 0.25 mfd 600V
capacitors (C1). One 10 mfd 250V capacitors (C2) and one 10 kpf 500V capacitor (C3) are
provided across the bridge for filtering DC output and protection against high frequency surges
respectively. Capacitors, C, c and resistors are provided as filter for reducing the ripple content.
Three current transformers primaries are connected in series to the alternator supply.
Function: When the field coils are excited and rotor is rotated the variation in reluctance offered
by the rotor teeth arrangement causes the flux produced by the field coil to pulsate. This pulsation
of flux linked with Ac coils and induces e.m.f in the AC windings. The induced e.m.f. in the 3
phase winding is rectified by the 3 phase bridge rectifier. The bridge rectifier also serves the
purpose of maintaining the constant polarity in both the directions of the train and prevents
current flowing from battery to alternator, when the coach is stable condition.
2. Field circuit: Field circuit consists of Magnetic amplifiers (MAI & MA1), field full wave bridge
rectifier (D1,D2,D3,D4) and free wheeling diode (D5) and normally closed contact of relay. ET
is eliminated and Two Magnetic Amplifier are used to control the field voltage and field current,
there by controlling the output voltage and output current. MA has six windings. Two are load
windings connected in series to the field circuit. One winding is used for voltage/current control
and one more winding used as feed back (gain) winding to boost output voltage whentrain is in
slow speeds. Two winding are spare. Free wheeling diode is provided to eliminate the surge
voltages produced in the field coil. Cathode of free wheeling diode connected to field positive
and anode to field negative.
Two phase AC supply of Alternator given to bridge rectifier through field fuse F2, NC of CR,
MA1, and MA2 load windings. Load winding terminals are arranged in such way that, series
connected two windings of MA1 and MA2 are included in each half cycle. Load windings
162,17, and 162, 17 are connected in one half cycle and 161,18 and 161,18 are included in the
other half cycle. The rectified DC positive is fed to field positive (+EX) of alternator through
gain winding 40 and 20 Two gain windings of MA1 and MA2 are connected in series. Rectifier
negative (19) of bridge rectifier is connected to field negative (-EX). Freewheeling diode is
connected across field terminals (19 and 20) in reverse direction.
Function: The purpose of field circuit is to feed rectified DC supply for field for excitation. Two
phase supply of alternator is rectified by bridge rectifier. This rectified DC is fed to field winding
through gain winding. Free wheeling diode is provided to dissipate energy produced in the field,
in other way to eliminate surge voltages produced in the field coil. Load windings are connected
in the field circuit to vary the field voltage and current.
3. Voltage control circuit: This circuit consists of auxiliary rectifier (RT1) voltage detector (DT1)
and voltage control winding of magnetic amplifier (10,11) blocking diode(D6). The voltage
detector consists of resistance network (R1,R2,R3,).and zener diode D8, potentiometer (RH1) is
connected across the resistance R3 to vary the output voltage settings. Voltage detector serves the
purpose of providing DC signal to the control winding of MA.
Function: When the output voltage exceeds the preset value, the drop across R1 is sufficient to
conduct zener diode and allows a DC signal to the voltage control winding of MA. The DC flux
produced in control winding will oppose the AC flux of load winding and increases impedance of
the field circuit. This increase of impedance, results in decrease of field voltage and field current
19
thereby decreasing output voltage. This process is continuous to maintain the output voltage
constant. The voltage setting can be varied by varying the potentiometer. In ’25 KW KEL RR
unit the control winding (10,11) are common for both voltage and current control. Two control
windings of MA1 and MA2 are connected in series. Diode D1 is provided to prevent creep age of
current from DT2 to DT1
4. Current control circuit: This circuit consists of 3 phase bridge rectifier (RT2), current detector
(DT2), blocking diode (D7), control winding of MA(10 & 11), and secondary o f current
transformer (CT1 to CT3)
The CT1 to CT3 play important role in the current control circuit. The primary of the CTs
connected in series with the 3 phase AC supply. The secondary of CTs connected to 3 phase
bridge rectifier (RT2). The output voltage of RT2 connected to current detector. RB1 connected
across DC output which acts as burden resistance. Current detector consists of resistance network
R4,R5 and R6 and zener diode D9. Zener diode D9 is connected across R4 is in series with
blocking diode D7 and control winding of magnetic amplifier (10-11). D2 prevents current from
DT1 to Dt2, RH2 is provided across R6 to vary the current settings.
Function: The current transformer CT1, CT2 and CT3 senses the current flowing in the 3 phases.
The burden resistance RB1 converts current signal into voltage signal. This Dc voltage is fed to
voltage detector. The voltage obtained from the secondary of CTs fed to the 3 phase bridge
rectifier RT2. When the current delivered by the alternator reaches predetermined value the
voltage drop across R4 is sufficient to conduct the Zener diode, thereby sending the control
current to magnetic amplifier control winding and increases the impedance of field circuit,
thereby decreasing field current/output current. This is a continuous process and maintains output
current at present value.
5. OVP Circuit: It consists of auxiliary rectifier (D13, D14, D15) Zener diodes (Z1-Z2), potentio
meter(pot) transistors (T1,T2,T3), relay coil (CR), freewheeling diode (D12) and LED (D18).
Function: When the output voltage shoots up more than 150 Volts due to failure in control
circuit, the drop across middle terminal of potentiometer and negative will be more than Zener
voltage of Z2, zener diode Z2 transistors TR1, TR2, TR3 conducts. The relay energized through
R4 and TR3, and field supply through NO (Normally open) of relay coil. At this stage the relay is
permanently energized unit the reset push button is pressed at base station by staff. Hence, once,
over voltage occurs, the field is permanently cut off in this type of regulators. D12 is provided
across relay coil to dissipate energy stored in it. Z1 is reference voltage diode. Glowing D17
indicates normal working.
20
CELLS
Preparation of Electrolyte:
The cells are supplied in dry uncharged condition.
These cells are required dilute Sulphuric acid of SPG ( 1.108-1.22), corrected up to 27
degree Centigrade as electrolyte for initial charging.
Electrolyte =H2SO4 ( as per IS:266) of SPG 1.835+ Water ( as per IS:1069)
To get 100 litres (approx) of electrolyte:
21
For SPG Water (litres) Acid (litres)
1.180 86 17
1.220 82 21
Concentrated acid should always be poured into the water and never the water in the acid in
Ebonite box.
Initial filling:
Filling the electrolyte up to the lower marking on the float indicator
Allow the cell to rest for a period of around 16-24 hrs.
Level of electrolyte may fall. Restore this with some electrolyte.
Now the cells are ready for 1st charging.
Initial Charging:
Charge the cells for 80/100 hrs at specified rate as per manufacture’s data .
(40 A for 800 Ah, 06 A for 120 Ah…….)
During charging, temperature should be less than 50 degree. After 45 degree, reduce the
charging rate to ½ value & increase the time accordingly.
Total charge input should be equal to Time X current ( specified Charging current )
While charging, level of electrolyte may fall due to water loss. Restore for 24 hrs by
adding water.
Adjust the SPG to 1.215+/-0.005 corrected to 27 degree.
Adjust the SPG, the cells must be gassing freely for a minimum 2 hrs of charging. This
helps in proper mixing of electrolyte.
Now cells should be discharged through a suitable resistance at constant current
(I)=0.10XC10 amps up to 1.80 VPC.
The battery shall be charged at normal charging
When a battery is kept as an emergency reserve, it is very essential that it should be found fully
charged when an emergency arises.
Due to leakage action and open circuit losses, the batteries deteriorate .Hence to keep it fresh,
batteries are kept on a small charging.
For example: A standby battery for station bas-bar of 400 Ah at 10 hr rating, a continuous trickle
charge of 1 Amp will keep the cells fully charged and keep in perfect condition.
(i) Gassing
When the cell is fully charged, it freely gives off hydrogen at cathode and oxygen at the anode,
the process being known as “Gassing”. Gassing at both plates indicates that the current is no
longer doing any useful work and hence should be stopped. Moreover, when the cell is fully
charged, the electrolyte assumes a milky appearance.
(ii) Voltage
22
The voltage ceases to rise when the cell becomes fully – charged. The value of the voltage of a
fully – charged cell is a variable quantity being affected by the rate of charging, the temperature
and specific gravity of the electrolyte etc. The approximate value of the e.m.f is 2.1 V or so.
(iii) Specific Gravity of the Electrolyte
A third indication of the state of charge of a battery is given by the specific gravity of the
electrolyte. We have seen from the chemical equations of Art.9.9, that during discharging, the
density of electrolyte decreases due to other production of water, whereas it increases during
charging due to the absorption of water. The value of density when the cell is fully charged is 1.21
and 1.18 when discharged up to 1.8 V. Specific gravity can be measured with a suitable
hydrometer which consists of a float, a chamber for the electrolyte and a squeeze bulb.
(iv) Colour
The colour plates, on full charge is deep chocolate brown for positive plate and clear slate gray for
negative plate and the cell looks quite brisk and alive.
52. What are the Factors affecting the life of Lead Acid Battery?
Factors affecting the life of Lead Acid Battery:
1. Necessity of frequent topping of cells.
2. Leakage of electrolyte on lid and on container body.
3. Failure on one cell on a mono-block unit.
4. Undercharging / overcharging.
5. Always use distilled water for toping of cells.
6. Keeping the discharged cells for long time will result in formation of sulphation.
53. What are the diseases associated with a Lead Acid Batteries and their remedial
action?
SULPHATION:
Sulphation means the formation of lead sulphate on the surface and in the pores of the active
materials of the plates. Sulphate is finely crystalline and easily reduced by the charging current.
Sulphation in this sense is a necessary part of the operation of battery and is not a source of
trouble. Lead sulphate is also formed as result of local action or self discharge of the plate. This is
brought about by the action of the acid solution on the concentration and temperature of the
electrolyte. Lead sulphate formed as a result of local action is easily reduced by the charging
current unless it is neglected. Sulphation applies to the large crystals of lead sulphate that may
form on the plates as a result of neglect or misuse. Excessive sulphation of this type is difficult to
reduce and may injure the plates. The effect is usually noticed by a whitish colour on plates and is
23
caused by over charging, over discharging or keeping the discharged battery for a long time.
Carbonate of soda added to the electrolyte has a beneficial effect in preventing sulpahtion defect,
or the best way is trickling charge i.e., charging the battery at a low rate for long time.
CAUSES OF SULPHATION
1. Due to over charging
2. Over discharging
3. Impurities in acid, plates, or electrolyte
4. Due to plates are not covered by the electrolyte
5. Due to neglect of battery, Sulphation is caused
6. Kept under discharged condition for long time
54. What are the points to be followed for the Healthy condition of the Battery set?
24
voltage is about 1.85 volts, it should be considered as practically fully discharged and
arrangements are made for charging.
HYDRO METER:
This meter is used to measure SPGR of liquids. It consists of glass tube with a glass bulb. The
glass bulb is fitted with lead balls and is fitted with scale, on which SPGR is marked. This glass
bulb is kept in a glass tube. One side of glass tube is fitted with rubber bulb and on the other side a
nozzle. The rubber bulb is pressed to suck electrolyte from the battery. The electrolyte enters in
the outer glass tube in which hydro meter bulb floats and gives reading. With the dilute sulphuric
acid the bulb sinks more in the electrolyte, while with strong sulphuric acid the bulb less. In this
way it gives reading to know the performance of battery.
25
5. Terminals:
High conductivity lead plated inserts.
6. Safety Valve:
Self resealing, pressure regulated and explosion proof.
7. Container and Cover Sealing:
Heat Sealing Method (Fusion bond) for better joint strength
8. Container:
High impact Polypropylene co-polymer
26
59. What are the advantages of VRLA batteries over conventional flooded tubular
batteries?
1. Regular maintenance required involving 1. No periodic topping since this battery work
topping up with distilled water. on the oxygen recombination reaction
resulting in zero loss of water.
2. A lot of excess free acid is available leading 2. No stratification of electrolyte because of the
to acid stratification. This is more wicking action of the absorbent separators.
pronounced in taller cells. The cells are mounted horizontally reducing
the height of cell. Stratification is there fore
eliminated.
3. There is a possibility of ground currents due 3. There is no possibility of electrolyte spillage
to electrolyte spillage. This can result in due to the dry leak proof construction hence
high rates of self discharge. ground currents are eliminated.
4. Batteries are housed in MS boxes under the 4. The VRLA battery unit can directly bolted
coaches. horizontally to the under carriage of the
coach. This will eliminates the need for
battery boxes as well as the FRP trays used
in existing designs.
27
leading to uniform intensity of light bulbs,
for longer duration.
60. Explain the procedure for the POH of VRLA cells in workshop.
8. Charge the cells at 7% constant current {77 Amps for 1100 Ah and 8.4 Amps for 120 Ah} for
15 hours.
9. Again give rest to the cells for 6-8 hours.
10. Discharge the cells at 12 Amperes for 120 Ah and 110 Amperes for 1100 Ah gradually by
passing each cell whenever each cell reach 1.75 V. Duration of discharge shall be recorded. If
the discharge duration of the cells is found to be more than 8 hrs these can be put back in
service after charging.
11. If the cells do not give more than 8 hrs of discharge duration before reaching end cell voltage
of 1.75 V, repeat this charging and discharging cycle once more. Cells should not be
discharged below 1.75V .
12. Even then, if the cells do not give more than 8 hrs then the cells shall not be put in service.
13. Clean and repaint the modules/ cell trays. These may be numbered with the help of stenciling
28
to identify the modules consisting of a battery set for a coach { say Module No / Set No. e.g.
08 /01 means 8th module of Set No. 1} . The other details like cell number, date of manufacture
as indicated on the cell lid and date of fitment shall also be recorded to monitor age-wise
performance of the cells.
Note: All the new VRLA cells shall be given a boost charging if the cells have been lying in the Depot /
workshop for more than 6 month period from the date of manufacture.
29
QUESTION BANK FOR TRAIN LIGHTING COACHES
1. On what factors the output voltage of TL/AC alternator depends on?
Ans. The output voltage of TL/AC alternator depends on, speed of the rotor and level of field
excitation.
2. Write about the working principle of TL/AC alternator?
Ans. The core of the stator which is completely embraced by the field coils will retain a residual
magnetism if excited by a battery once. The flux produced by the filed coils find its path through
the rotor. When the rotor is rotated the passage of rotor teeth and slots, alternatively, under the
field, offers a varying reluctance path for the flux produced by the field coils. The flux, which
varies periodically, links with AC coils and induces an alternating voltage in AC coil. The
frequency of the induced voltage depends on the speed of rotor, where as the magnitude depends
on the speed of the rotor and the level of excitation. The field is controlled through regulator to
attain desired output voltage by means of positive feedback again.
3. What are the reasons for loss of residual magnetism? How do you regain it? What is the
permissible and maximum DC voltage is to be applied to regain the residual magnetism?
Ans. The reasons for los of residual magnetism are keeping the alternator in idle condition for long
time and connecting field wires in wrong polarity. To regain the residual magnetism flash the
field terminals for correct polarity of DC supply. The permissible DC voltage is to be applied to
regain the residual magnetism is 6 to 12V DC. Maximum voltage is 24V DC.
4. Explain the capacities of alternators used in TL/AC coaches?
= 25 KW 135 Volts
5. What is the purpose of belt-tensioning device? What are the parts it consists of?
Ans. The purpose of belt tensioning device is to keep V belts in tight condition.
Its parts are
1. Tension rod
2. Tension spring
3. Belt tension indicator with spring seat
4. Fork eye
5. Fork eye side spring seat
6. Belt tightening nut
7. Free end pipe and nut
30
61. Explain working principle of KEL ALTERNATOR/REGULATORS 110 V, 4.5 K.W with
the help of circuit diagram?
Ans
For easy understanding of KEL 3 & 4.5KW 30 volts alternator/rectifier regulator circuit diagram,
was divided into four sub circuits. They are
1. Power supply circuit
2. Field circuit
3. Voltage control circuit
4. Current control circuit
1. Power supply circuit: This circuit consists of 3 phase alternator (ALT) & 3 phase bridge
rectifier.(PR). Three phase AC supply (13,14,15 terminals) produced by alternator is fed to 3
phase bridge rectifier consists of 6 silicon power diodes. The bridge is protected against voltage
surges by 6 numbers of 0.25 mfd capacitors (C1 to C6), One 10 mfd capacitor (C7) and one
10000pf capacitor (C8) are provided across the bridge for filtering DC output and protection
against high frequency surges respectively. Shunt (26 amd 28) is provided in series to DC output
voltage positive (+L) terminal,for sensing output current. DC output voltage terminals are(+L,-C)
Function When the field coils are excited and rotor is rotated the variation in reluctance offered
by the rotor teeth arrangement causes the flux produced by the field coil to pulsate. This pulsation
of flux linked with Ac coils and induces e.m.f. in the AC windings. The induced e.m.f. in the 3
phase winding is rectified by the 3 phase bridge rectifier. The bridge rectifier also serves the
purpose of maintaining the constant polarity in both the directions of the train and prevents
current flowing from battery to alternator, when the coach is stable condition.
31
2. Field circuit: Field circuit consists of Excitation transformer (ET) Magnetic amplifier(MA),.
Field rectifier (D2,D3) and Free wheeling diode(D4). And ET is an auto step up centre tapped
transformer. It has three functions. 1. It is auto transformer having one winding 2. It steps up the
voltage for good regulation of output voltage and current. 3. Its secondary winding is centre
tapped used for full wave rectification with two diodes and accommodates load windings of MA.
Magnetic Amplifier is used to control the field voltage and field current, there by controlling the
output voltage and output current. It has six windings. Two are load windings connected in series
to the field circuit. One winding is used for voltage control and one more winding is used for
current control and other winding used as gain winding to boost output voltage when train is in
slow speeds one more winding is spare. Free wheeling diode is provided to eliminate the surge
voltage produced in the field coil. Cathode of free wheeling diode connected to field positive and
anode to field negative.
Two phase AC supply of Alternator given to ET primary (14 & 15 terminals) through field fuse
F2. The centre tap secondary terminals (19) is connected to field negative (-EX) of alternator.
The end terminals of ET secondary ( 18 &161) are connected to full wave rectifier (D2 &D3)
through MA load windings (18,162 and 161,17). The rectified DC fed to field positive (+EX) of
alternator through gain winding. (40 and 20). Free wheeling diode is connected across field
terminals (19and20) in reverse direction.
Function: The purpose of field circuit is to feed rectified DC supply for field for excitation. Two
phase supply of alternator is stepped up by ET and rectified by full wave rectifier. This rectified
DC is fed to field winding through gain winding. Free wheeling diode is provided to dissipate
energy produced in the field, in other way to eliminate surge voltages produced in the field coil.
3. Voltage control circuit: This circuit consists of auxiliary rectifier(RT) (D5,D6,D7), voltage
detector (DT) and voltage control winding of magnetic amplifier(10,11). The voltage detector
consists of resistance network (R1,R2,R3,R4) and zener diode D8, 1k potentiometer (RH) is
connected across the resistance R4 to vary the output voltage settings. Voltage detector serves
the purpose of providing DC signal to the control winding of MA.
Function: When the output voltage exceeds the present value, the drop across R1 is sufficient to
conduct Zener diode and allows a DC signal to the voltage control winding of MA. The DC flux
produced in control winding will oppose the AC flux of load winding and increases impedance of
the field circuit. This increase of impedance, results in decrease of field voltage and field current
there by decreasing output voltage. This process is continuous to maintain the output voltage
constant. The voltage setting can be varied by varying the 1k potentio meter.
4. Current control circuit: This circuit consist of shunt resistance (SHR 26,28 terminals) shunt
diode(D1) and current control winding of M.A(26and27). For sensing output current, SHR is
provided in the DC output voltage of alternator. Shunt leads are connected to MA current control
winding through shunt diode.
Function: When preset value of current is supplied by the alternator exceeds, the voltage drop
across the shunt is sufficient to conduct shunt diode. When shunt diode conducts, it sends a DC
signal to current control windings of MA. This DC signal induces DC flux in the windings. This
Dc flux opposes the AC flux of load windings and increases the impedance of the field circuit.
Increase of impedance in field circuit reduces the field voltage and field current there by
decreasing the output voltage and output current. This process repeats when the output current
32
exceeds and maintain the alternator current within preset limits. The current setting can be varied
by varying the shunt resistance.
62. What are the precautions to be taken while loading and unloading of alternator?
Ans. i) While unloading and loading alternator, see that the terminal box and pulley should not be
broken.
ii) The alternator to be loaded in correct way that bushes to be provided in proper place.
iii) While loading and unloading proper precautions to be taken not to fall on ground otherwise
men/materials will be injured/damaged.
iv) See that the anti rotating clamp provided on trolley coincides with alternator suspension pin.
v) Replace the worn out alternator and alternator suspension bracket bushes.
vi) See that the alternator should not have play with proper washers in improper place to align the
axle pulley.
vii) Safety chains and cotter pins to be provided without fail.
63. What are the Rating of various fuses in TL coach wiring system?
Ans. The specific gravity of fully charged cell is in between 1.210- 1.220
66. What is meant by PPCP container?
Ans. Some cell container are made of PPCP which is called Poly Propylene Co-Polymer.
67. What is the SWG of DFB fuse?
Ans. The size of fuse wire 35 SWG is provided in Distribution Fuse board for each fan or light.
68. What is the wattage of 400 mm 110 V DC fan?
Ans. The specific gravity of sulphuric acid which is used to make electrolyte is 1.835.
70. What is the working voltage of 20 W/18W TL inverter?
33
Ans. Double test lamp method.
72. Enumerate the cable sizes used in TL coaches?
Ans. The maximum permissible voltage drop allowed between the battery and any of the farthest
light/fan point shall not exceed 3 volts at battery voltage of 108 +0/-2 volts.
74. What is the insulation tape used for insulation of cables in TL &AC coaches?
34
i) After re-wiring the test the insulation resistance with 500v dc megger. The minimum insulation
resistance should be 2 Mega ohms.
24. Procedure to maintain correct tension of new ‘V’ belts on bogie transform mounted
alternator of AC Coaches and non AC coaches.
Ans. Advantages:
1. The demand for better passenger amenities like improved illumination, provision of tube lights
with inverters, provision of water coolers/refrigerators can be achieved in this system.
2. For the same loads, the current handled is only 21.8% therefore cables and connectors are smaller
in size.
3. The ratio of short circuit current and the normal full load will be high. Therefore faults
discrimination better in 110 V systems.
4. Florescent lights can be used with the aid of electronic invertors (without choke and bulb).
5. Higher coach loads can be handled with the higher generation capacity to meet the additional
amenities like.
Provision of fluorescent lamps in sleeper coach.
Provision of more fans in sleeper and GS coaches.
Provision of water coolers in coaches etc.
Due to current flowing in the circuits is low the voltage drop reduced to minimum the
illumination in the coaches is improved.
6. In the 110V DC system, the size and weight of the cells reduced considerably easy to handle.
7. Bogie transform mounted alternators with V belts are provided to avoid theft of belts and
alternator parts.
Disadvantages:
1. In the 120 volts system single battery is provided load on the battery is more. The life of the
battery is reduced considerably.
2. Due to introduction of transform mounting system the complete coach has to be lifted for
replacement of V belts.
35
3. Due to provision smaller size batteries, the quantity of electrolyte is limited. If the level of
electrolyte is not maintained by adding distilled water, the batteries may damage.
4. Due to high voltage system, requires high value of insulation resistance for safety etc.
26. What are the major train lighting equipment available in Self Generating coaches and
explain about them briefly?
RJB
16 A
R (+)FDB
R 32A
U
6A
Alternator
4.5 kw
110 BCT
V
DC + ve
- ve
6A
120
Ah
Major Equipment:
36
Alternator - 4.5 kw, 110V, 3 phase, brush less type, totally enclosed, reversible shunt
wound.
Regulator Board (RRU/ERRU) - 4.5 kw.
Battery - 120 Ah, 110 V DC, lead acid / VRLA type
Light: - 25 w /20w, 110v DC.
Fans:- 40 w
V-belts, axle pulley & alternator pulley
Protective device:
OVP
HRC fuse (32 A/40 A, 16A, 6A)
Rotary switch (40 A)
28. Draw the neat Coach Wiring Diagram of 110V DC TL system including capacities of
equipment and protection devices?
Diagram Of 110 Volts DCTL System Including Capacities Of Equipment And Protection Devices
37
MAJOR EQUIPMENTS IN TL COACH:
Alternator – 4.5 kw, 110V, 3phase, brush less type, totally enclosed, reversible shunt wound
Regulator Board-4.5 kw
Battery-120 Ah, 110V DC, lead acid / VRLA type
Light -15 w / 20w.110V DC
Fans-40w
V-belts, axle pulley, alternator pulley
PROTECTIVE DEVICE:
OVR / OVP
HRC fuse ( 40 A , 16 A, 6A)
Rotary switch (40 A)
38
29. What are the sizes / capacity of fuses provided at various locations of 110 Volts Train
Lighting coach?
Ans.
Sl. No. Circuit fuse Location Fuse size Current rating
1. Positive/negative Branch fuses DFB 35 SWG 6A
2. SPM1 & SPM2 Junction box RW ---
3. Main negative J/Box 16A HRC ---
4. L1, L2, and F +ve J/Box 35A HRC ---
5. Battery fuse Battery box 16A HRC ---
6. Field fuse Regulator box 40A HRC 6A
7. AC fuse Regulator box 6A HRC 20 ---
35A HRC
Advantages of ERRU:
1. Control circuit is Modular type design.
2. Auto identification of alternator ratings and indications.
3. Auto setting of parameter of voltage, load current, Battery current, over voltage, over current
and current limiting for all the regulator of 4.5 kw, 18kw and 25kw.
4. UVC is interchangeable with all types of electronic regulators from 4.5 kw to 2.5 kw.
5. Close regulation of voltage +/-2 V over the entire range of load and speed to have uniform
charging of batteries.
6. Less voltage and current ripple on Battery Charging current.
7. Controlled battery charging current to have longer life of batteries.
8. Moduled Hall sensors for current sensing and setting current limit.
9. Static over voltage protection and latching without battery.
10. Isolated power packs directly mounted on the heat sinks to have better heat dissipation.
11. Moulded PCBs to avoid dust and vibration problems.
12. Separate interface unit for monitoring the parameters like DC Voltage, DC current, Battery
charging and discharging currents, Amps Hours etc.
13. This interface facilities to store AH.IN and AH.OUT. generation and non-generation time, total
distance travelled by coach and faults occurred in the regulators.
14. This interface also has Emergency unit. In case of failure of one control unit, the other control
unit will take care of both regulators.
Disadvantages of ERRU:
1. Sophisicated electronic equipment.
2. Qualified staff are required for maintenance.
3. Costlier than MA type regulator.
4. If PCB failed entire PCB to be changed.
5. For repairing ERRU on test bench, Alternator supply must be required.
39
6. Alternator setting can not be adjusted manually on test bench.
7. Costlier spare parts are to be stocked.
40
The discrete power supply for powering the UVC micro processor / micro controller must be
electrically isolated from coach battery DC power.
Following indication shall be available on UVC / display unit in case of 4.5 KW whereas for 25 KW
ERRU on UVC and CIP.
Capacity of alternator
Healthiness of UVC
41
OBJECTIVE TYPE QUESTIONS
7. The danger for the human body, if the temperature falls below
a) 98°F b)98.6°F c) 105.6°F d)None
8.The temperature of air recorded by a thermo meter, when it is not affected by the moisture
present in it, is called
a)Wet bulb temperature c)Dew point temperature
b)Dry bulb temperature d)None of those
42
11.Psychometric chart shows relationship between
a) Dry bulb temperature d)Humidity
b) wet bulb temperature e) Total heat (enthalpy)
c) Dew point temperature f) All of the above
15. The cooling in the coach is not sufficient, the reasons may by
a) Compressor not getting loaded/poor efficiency
b) Too little gas or air may have accumulated in the system
c) Condenser, fresh/return filters, evaporator dirty/choked
d) Setting of expansion valve disturbed
e) All of the above.
43
21. Quantity of Refrigerant to be charged for one AC circuit of RMPU is about
a) About 3kgs c) About 30kgs
b) About 20kgs d) None
22. Power supply is fed to compressors and condenser and evaporator units of RMPU coach is
a) 1.5 HP c) 2.5 HP
b) 0.5 Hp d) None
a) 6 KW c) 12KW
b) 3KW d) None
44
32. Speed of the condenser motor of RMPU coach is
a) 910 RPM c) 2880 RPM
b) 720 RPM d) None
39. The cooling temperature settings of electronic thermostat are recommended by RDSO is
a) 23°C,25°C c) 24°C,26°C
b) 22°C,25°C d) None
40. The heating temperature settings of electronic thermostat are recommended by RDSO is
a) 17°C,19°C c) 21°C, 23°C
b) 19°C,21°C d) None
45
44. The duration of TDRI delay setting is
a) 2 min c) 3.5 min
b) 2.5 min d) None
49. The purpose of auxiliary contactor AC1 provided in control panel of AC coach is
a) To switch on control supply to condenser motors I & II
b) To switch on control supply for compressor motors I & II
c) To switch on control supply to heaters I & II
d) To switch on control supply to entire control circuit except blower circuit
50. The purpose of vane relays 1 & 2 provided in the RMPU AC system is to
a) Not to switch ON condenser motors in case of blower failure
b) Not to switch ON compressor motors in case of blower failure
c) Not to switch ON heaters in case of blower failure
d) Not to switch ON entire AC system in case of blower failure
51. The cut in pressure of the reciprocating compressor type WRA used in RMPU coach is
a) 0.3kg/sq cm c) 1.7 kg/sq cm
b) 0.75 kg/sq cm d) None
52. The cut out pressure of the reciprocating compressor type WRA used in RMPU coach is
a) 0.3kg/sq cm c) 1.7 kg/sq cm
b) 0.75 kg/sq cm d) None
46
55. The recommended refrigerant in place of R 12 is
a) R22 c) R100
b) R134a d) None
59. Capacity of battery used in RMPU AC coach other than first class is
a) 800AH c) 540AH
b) 1100AH d) None
62. The capacity of HRC fuses to be provided for 1100AH battery of SG RMPU AC coach is
a) 400A c) 100A
b) 250A d) None
63. The capacity of plant selector rotary switch RSW2 provided in power panel of RMPU AC coach is
a) 300A c) 63A
b) 400A d) None
64. The capacity of HRC fuses both positive and negative to be provided for plant selector circuit in
power panel of RMPU AC coach is
a) 400 A c) 63 A
b) 250 A d) None
65. The capacity of power selector4 rotary switch RSW1 provided in power panel of RMPU AC coach
is
a) 500 A c) 16 A
b) 160 A d) None
47
66. Refrigerant used in under slung AC unit is
a) R22 c) R407C
b) R134a d) None
70. The capacity of battery is provided in AC under slung coaches single set of
a) 525 AH 56 cells c) 1100 AH 56 cells
b) 800 AH 56 cells d) None
72. Capacity of condenser motor used in first class under slung air condition system
a) 1.0 KW c) 2 KW
b) 0.75 KW d) None
73. The capacity of evaporator fan motor used in first class under slung AC coach
a) 1 KW c) 1.5 KW
b) 0.65 KW d) None
74. The speed of the condenser fan motor used in AC first class under slung AC coach
a) 1500 RPM c) 750 RPM
b) 2800 RPM d) None
75. The speed of the evaporator fan motor used in AC under slung system
a) 1500 RPM c) 700 RPM
b) 3000 RPM d) None
76. The total capacity of AC system used in AC two tier and AC composite coach
a) 10.4 tons c) 14 tones
b) 13.4 tons d) None
77. The capacity of alternator used in under slung AC chair car, AC sleeper coach, AC composite
coach are
a) 18 KW 135V c) 25 KW 135V
b) 12 KW 135 V d) 22.5 KW 135V
48
78. When under slung AC coach is working in normal condition the section pressure gauge reading
should be
a) 37-40 PSI c) 135 to 150 PSI
b) 150 to 170 PSI d) None
79. When under slung AC coach is working in normal condition the delivery pressure gauge
reading should be
a) 37-40 PSI c) 50 to 70 PSI
b) 150 to 170 PSI d) None
80. The oil pressure of the compressor is
a) 70 to 90 PSI c) 200 PSI
b) 150 PSI d) None
81. Recommended setting of low pressure cut out of under slung AC coach is
a) 10 PSI c) 25 PSI
b) 250 PSI d) None
82. Recommended setting of low pressure cut out of under slung AC coach is
a) 10 PSI c) 25 PSI
b) 250 PSI d) None
83. Recommended setting of high pressure cut out of under slung AC coach is
a) 10 PSI c) 25 PSI
b) 250 PSI d) None
84. Recommended setting of oil pressure cut out for ACCEL and CARRIER in under slung AC coach is
a) 10 PSI c) 25 PSI above section pressure
b) 250 PSI d) None
85. The purpose of low voltage relay (LVR) used in control panel of under slung AC coach is
a) Stop the compressor motor/condenser motor, heaters if the battery voltage less than 100V
b) It cuts of the supply to control circuit
c) It will reset if the battery voltage rises to 102 V
d) All of the above
86. In under slung AC coach, the rating of fuseF2 + provided for protection of heater
a) 125A c) 10A
b) 63A d) 2A
87. Recommended grades of oil for compressor are
a) Frezol 3 d) Servo FreeZ-66
b) Sheftal 68 e) All of the above
c) Servo FreeZ-71
88. Chemical name of refrigerant R 134a
a) Dichloro difluoro methane c) Tetra fluoro ethane
b) Chloro difluoro methane d) None
49
92. An electrolyte use in train lighting cell is the mixture of
a) Sulphuric acid and tap water
b) Sulphuric acid and mineral water
c) Sulphuric acid and demineralized/distilled water
d) None of the above
93. When cell is fully charged, the positive plate becomes
a) Lead peroxide c) Lead sulphate
b) Spongy lead d) None
94. When the lead acid cell is fully charged the negative plate becomes
a) Lead peroxide c) Lead sulphate
b) Spongy lead d) None
95. The capacity of cell is measured in
a) Ampere hour c) Amperes
b) Watt hour d) Watts
96. Internal resistance of lead acid cell is mainly due to
a) Size of plates c) Nature of electrolyte
b) Distance between the plates d) All the above
97. Trickle charging of storage battery help to
a) Compensate for internal losses c) Increase its capacity
b) Maintains proper electrolyte d) None
98. The capacity of Battery used in 110V T.L system
a) 120AH c) 320Ah
b) 210Ah d) 90AH
99. SPGR of fully charged cell
a) 1.220 c) 1.140
b) 1.180 d) 1.100
100. SPGR of half charged cell
a) 1.210 c) 1.100
b) 1.175 d) 1.140
101. SPGR of fully discharged cell is
a) 1.210 c) 1.200
b) 1.175 d) 1.140
102.Total number of cells available in TL Battery of 110V system
a) 54 c) 24
b) 56 d) 18
103. Sulphation occurs due to
a) Cells kept under discharged condition
b) Cells kept under not fully charged condition
c) Cells over charged
d) All the above
104. The codal life of lead acid TL/AC cells is
a) 4 c) 2
b) 3 d) None
105. The capacity of batteries used for RMPU AC coaches is
a) 525 AH c) 800 AH
b) 400 AH d) 1100 AH
50
106. VRLA Batteries works on
a) Oxygen recombination principle
b) Hydrogen recombination principle
c) Hydrogen-oxygen recombination principle
d) None of the above
107. Normally the VRLA cells mounted in a position.
a) Horizontal c) Slanting
b) Vertical d) None
108. VRLA battery separators can be of
a) The gelled electrolyte type c) A & b
b) The absorbed electrolyte type d) None of the above
109. Conductivity is the ability of a solution to conduct electrical current commonly expressed in
a) Amperes c) Micro mhos/cm
b) Watt d) None
110. Conductivity of DM water is measured by
a) Conductivity meter c) pH meter
b) Universal solution d) all of the above
111. Acceptable quality of treated water conductivity is in micro mhos/cm
a) <10 c) 40
b) <30 d) None
112. Acceptable quality of treated water PH value will be
a) 6.8 to 7.2 c) 8.5 to 10
b) 7.5 to 8.5 d) None
113. Inverters convert
a) AC into DC c) Both a & b
b) DC into AC d) None
114. In 25 KVA inverter the 3 phase AC supply is achieved by boosting DC voltage 100/140 volts into
a) 230V DC c) 415V DC
b) 650V DC d) None
115.Out put PWM voltage of inverter section of 25 KVA inverter of RMPU AC coach is
a) 650VDC c) 24V DC
b) 220VDC d) 3 phase 415 V AC
116.Alternator is a device that converts
a. Mechanical energy into electrical energy
b. Electrical energy into mechanical energy
c. Chemical energy into electrical energy
d. None of the above
117. Both field winding and 3 phase winding of AC coach alternator 120V are provided on
_________
a. Stator c. Both a and b
b. Rotor d. None
118.TL/AC coach alternator 120V designed to have ______________
a. Residual magnetism c. Both a and b None of the above
b. Permanent magnetism
51
119.Recommended Cut in speed of 4.5 KW TL alternator is by RDSO with MA RR unit
___________
a. 357 rpm c. 1100 rpm
b. 600 rpm d. 2500 rpm
120.Minimum speed for full output of 4.5 KW 120V TL alternator, recommended by RDSO is
_______
a. 357 rpm c. 1500 rpm
b. 600 rpm d. 2500 rpm
121.Maximum speed of TL/AC coach alternator is
a. 400 rpm c. 1500 rpm
b. 800 rpm d. 2500 rpm
122.Field coils of 120V TL/AC coach alternator are connected in
a. Series c. Star
b. Parallel d. Delta
123.Three phase windings of 120V TL/AC coach alternator are connected in
a. Star c. Series
b. Delta d. Parallel
124.Size of V belts used for driving 110V, 4.5KW TL alternators
a. C122 c. C124
b. C118 d. None
125.Size of V belt used for driving 110V, 18, 22.5KW AC coach Alternators
a. C122 c. C124
b. C118 d. None
126.Number of V belts used for driving 110V, 4.5KW TL alternator is ___________
a. 4 c. 12
b. 6 d. None
127.Number of V belts used for driving 110V, 18, 22.5, 25KW AC alternator is ___________
a. 4 c. 12
b. 6 d. None
128.DC output voltage of Alternator /Regulator of 110V, TL/AC coach is
a. (110-140) DC c. (90-120) DC
b. (70-90) DC d. None
129.Rated DC output current of 4.5KW 110V, Alternator is ____________
a. 37.5A c. 43A
b. 19A d. None
52
130. Rated DC output current of 18KW 110V Alternator is ____________
a. 193A c. 135A
b. 175A d. None
131. Rated DC output current of 25KW 110V Alternator is ____________
a. 193A c. 135A
b. 175A d. None
132. Pitch circle diameter of Axle pulley of 110V TL system
a. 200mm c. 5726mm
b. 140mm d. None
133.Pitch circle diameter of Axle pulley of 110V AC coach system
a. 200mm c. 572.6mm
b. 584mm d. None
134.As per the latest SMI, the voltage setting of alternator 4.5KW 110V for passenger train
with flooded batteries is ____________
a. 127V DC c. 122V DC
b. 124V DC d. None
135.As per the latest SMI, the voltage setting of ac alternator 18KW 110V with flooded
batteries is
a. 129V DC c. 122V DC
b. 124V DC d. None
136.As per the latest SMI, the voltage setting of alternator 4.5KW 110V for passenger train
with VRLA batteries is ____________
a. 123+/-0.5V DC c. 121+/-0.5V DC
b. 124+/-0.5V DC d. None
137.As per the latest SMI _____the voltage setting of alternator 4.5KW 110V for mail/express
trains with VRLA batteries is ____________
a. 123+/-0.5V DC c. 121+/-0.5V DC
b. 124+/-0.5V DC d. None
138.As per the latest SMI the voltage setting of alternator 4.5KW 110V for super fast trains
with VRLA batteries is ____________
a. 123+/-0.5V DC c. 121+/-0.5V DC
b. 124+/-0.5V DC d. None
139.As per the latest SMI the voltage setting of AC coach alternator 110V for passenger train
with VRLA batteries is ____________
a. 128+/-0.5V DC c. 126+/-0.5V DC
b. 127+/-0.5V DC d. None
53
140.As per the latest SMI the voltage setting of AC coach alternator 110V for Mail/express
train with VRLA batteries is ____________
a. 128+/-0.5V DC c. 126+/-0.5V DC
b. 127+/-0.5V DC d. None
141.As per the latest SMI the voltage setting of AC coach alternator 110V for super fast train
with VRLA batteries is ____________
a. 128+/-0.5V DC c. 126+/-0.5V DC
b. 127+/-0.5V DC d. None
142.The purpose of TL Alternator used in Railways.
a. Charging the coach battery on train run
b. Working of lights and fans in the coach during train run
c. Sharing the load to other coaches in case of emergency
d. All the three above
143.The capacity of alternator used for BG coach 110V Train Lighting system.
a. 3KW c. 12KW
b. 4.5KW d. None
144.The capacity of alternator used for BG coach 110V roof mounted AC coach
a. 12KW c. 25KW
b. 18KW d. None
145.The capacity of alternator used for BG coach 110V under slung AC coach.
a. 25KW c. 18KW
b. 12KW d. None
146.The PCD (pitch circle diameter) of 25KW 110V alternator pulleys is
a. 584mm +/- 0.4mm d. 100 mm
b. 200+/-0.3 e. None
c. 140 mm
147.The field resistance of 4.5KW 110V TL alternator has
a. 4.5 +/-0.5 ohms c. 10+/-0.5 ohms
b. 6.0+/-0.5 ohms d. None
148.The resistance between two phases of 4.5KW 110V TL alternator is
a. 0.4 +/-0.05 ohms c. 4.5 +/-0.5 ohms
b. 0.8 +/-0.10 ohms d. None
149.The purpose of providing anti rotating clamp near suspension arrangement of alternator is
a. Not to rotate suspension pin of alternator
b. Not to damage the nylon bushes of alternator/ suspension bracket
c. Not to damage the suspension bracket/boss of alternator
d. All of the above
54
150.The insulation material recommended for alternator windings of 3&4.5 KW 110V shall
be __________ class.
a. A c. F
b. B d. None
151.The voltage setting of Alt/RR unit is to be set in far with current and RPM for 4.5KW is
a. Half rated capacity of the alt as load as 1500 RPM
b. ¼ rated capacity of the alt as load at 1000 RPM
c. Full rated capacity of alt as load at 2550 RPM
56
172.Width of grooved axle pulley of 18, 22.5, 25 KW alternator is
a. 200 mm c. 136 mm
b. 190 mm d. None
173.The type of suspension bushes are to be provided TL/AC alternators/ suspension bracket
as per RDSO specification no RDSO / PE/Ac/0006/99 (Rev.0)
a. Cast nylon bushes c. MS bushes
b. Nylon 66 bushes d. All of the above
174.Residual magnetism lost in the alternator core the reason is
a. Field polarity changed c. Both a and b
b. Alternator is in idle condition for long
time
175.As per the Railway Board letter No. 2006/Elec(G)/138/3Pt. I unit Exchange spare
recommended for alternators and Regulators for TL/AC depot
a. 5% c. 15%
b. 10% d. None
176.ERRU stands for
a. Electronic Rectifier cum Regulator Unit
b. Electro magnetic Rectifier cum Regulator unit
c. Electrostatic Rectifier cum Regulator Unit
d. None
57
181.The battery charging current limit with 4.5kW ERRU is to be set at
a. 24A +/-2A c. 36A +/- 2A
b. 12A +/- 2A d. None
182.The battery charging current limit with 25kW ERRU when both alternators are paralleled
is to be set at
a. 110A +/-5A c. 220A +/- 10A
b. 220A +/- 5A d. None
183.The battery charging current limit with 18kW ERRU when both alternators are paralleled
is to be set at
a. 80A c. 240A
b. 160A d. None
184.OVP provided with ERRU, shall latch before output voltage reaches to
a. Surge voltage c. Both a and b
b. Over voltage d. None
185.The rating of field fuse provided in HMTD ERRU
a. 10A c. 15A
b. 20A d. None
186. Matched set of ‘V’ Belts means
a) One belt drive
b) More than one belt drive length with in specified limits
c) More than one belt drive length not in specified limits
d) None of the above
58
192.3 phase Bridge rectifier in R.R. box converts
a) AC to DC c) Pulsating AC
b) DC to AC d) None
193. Regulator controls
a) Field voltages d) DC output current
b) Field currents e) All the above
c) DC output voltage
194.Capacity of Phase fuse provided in 4.5kW R.R.Box
a) 35A HRC c) 6A HRC
b) 16A HRC d) 10A HRC
195.Capacity of Field fuse provided in the 4.5kW Rectifier cum Regulator box
a) 35A HRC c) 16 HRC
b) 6A HRC d) 10A HRC
196.Capacity of HRC fuse provided for negative circuit in Rotary junction box excluding
alarm chain pulling indication light circuit.
a) 35A HRC c) 6A HRC
b) 16A HRC d) 10A HRC
197.Capacity of HRC fuses provided for positive circuit in RJB excluding alarm chain pulling
indication light circuit.
a) 16A HRC c) 10A HRC
b) 35A HRC d) 6A HRC
198.Capacity of Limit switch provided for Alarm chain pulling indication light circuit is
a) 10A c) 35A
b) 15A d) 40A
199.Positive and Negative cables in roof run through on either side of coach to avoid.
a) Earth leakages c) Short circuits
b) Over loads d) None
200.Level of Illumination is measured by
a) Multimeter c) Lux meter
b) Techno meter d) Conductivity meter
201.Recommended level of minimum illumination to be attined in Second class compartment
with F.T Fittings.
a) 30Lux c) 16Lux
b) 40Lux d) 60Lux
202. Recommended size of Aluminium cables for B +ve and B –ve in 110V coaches.
a) 16sqmm c) 4sqmm
b) 35sqmm d) 50sqmm
59
203.The wattage of TL Fan
a) 32W c) 80W
b) 10W d) 60W
204.The capacity of battery fuse for 110Volt SG TL coach is
a) 40A HRC c) 10A HRC
b) 16A HRC d) 4A HRC
205.The minimum clearance between the top of the battery and battery box for maintenance of
cells shall have
a) 50mm c) 100mm
b) 150mm d) None
206.M.S.Rod/MS Flat provided in the battery boxes after loading cells. The purpose of M.S
Rod/MS FLAT is
a) Anti theft arrangement c) Not to drop batteries on run
b) To strengthen the battery box d) All the above
207.Total number of mono block batteries for one set of 110V TL coach are .
a) 9 c) 18
b) 12 d) 54
208.The voltage of mono block battery of 110V coach is
a) 2V c) 6V
b) 1.5V d) 1V
209.Total voltage of one battery set (18 mono blocks or 54 cells) of 110V TL coach.
a) 24V c) 120V
b) 108V d) 110V
210.The insulation resistance of 110V coach when measured with 500V Megger during
healthy weather condition.
a) 2 mega ohms c) 3 mega ohms
b) 1 mega ohms d) 0.5 mega ohms
211.The insulation resistance of 110V coach when measured with 500V Megger during
adverse weather condition.
a) 2 mega ohms c) 3 mega ohms
b) 1 mega ohms d) None
212.Capacity of Rotary switches provided in Rotary junction box is
a) 40A
b) 16A
c) 10A
d) 15A
60
213.
204. NName of the meter used to measure Air velocity ( B )
a. Multi meter c. Thermometer
b. Anemometer d. Ammeter
214. Rating of Static inverter used in SG AC Coaches ( C)
a. 20 KVA c. 25 KVA
b. 35 KVA d. 22.75 VA
61
b. Hydrochloric Acid d. Phosphoric Acid
226. Give the Spg & Voltage of Fully charged cells ( A)
a. 1220 & 2.2 c. 1200 & 2.2
b. 1220 & 2.1 d. 1200 & 2.1
227. Cut in speed for B/L alternator for 25KW Alternator ( D )
a. 17 KMPH c. 20KMPH
b. 19 KMPH d. 22 KMPH
228. Inverter converts ( A )
a. DC to AC c. AC to AC
b. DC to DC d. AC to DC
229. Function of SPP relay ( A)
a. Preventing single c. Preventing shorting of phases
phasing
b. Both d. None
230. Function of proving relay (B)
a. Ensure of starting of c. Ensure of starting of compressor
heater /compressor before blower
before blower
b. Ensure of starting of d. Ensure of starting of liquid receiver.
blower motor before
compressor/heater
231. Cooling thermostats setting (mercury thermostats) in I AC (A )
coach
a. 22, 24, 26 c. 17, 19, 21
b. 24, 24, 26 d. 19, 19, 21
232. IGBT are used as ( A )
a. High frequency c. Low frequency switching device
switching device
62
238. Trickle charging of VRLA cell (C )
a. 2.3 V/Cell c. 2.25 V/Cell
b. 110 V/Cell d. 115 V/Cell
239. No of MA’s in 25 KW regulators (C )
a. 1 c. 2
b. 3 d. 4
240. No of ET’s in 25 KW regulators ( A)
a. 1 c. 2
b. 3 d. 4
241. Rectifier converts ( B)
a. DC to AC c. AC to AC
b. AC to DC d. DC to DC
63
252. Function of cooling pilot relay (A )
a Ensure the function of c. Ensure the function of heater
Compressor
b Ensure the function of d. None of the above
Compressor/Heater
Write down the abbreviation.
64
OBJECTIVE TYPE.
1. The process of removing heat from low temperature level and
rejecting at high temperature is called. REFRIGERATION
2. Any substances for change of its state at constant temperature
absorbs/give up heat is called. LATENT HEAT
3. The sum of sensible heat and latent heat of substance in
process is called ENTHALPY.
4 The latent heat of fusing ice is 144 BTU/LB
5. The unit of refrigeration is TON OF REFREGIRATION –
12000 Btu/Hr or 3023.98 K.Cal/Hr
65
QUESTION BANK FOR ELECTRICAL POWER
MAINTENANCE
66
TRANSFORMERS
1. What is the transformation ratio?
E2 = N2 = I1
E1 N1 I2
67
7. Why are transformers fitted with oil conservator?
68
13. Briefly explain the maintenance schedule to be carried out on a transformer?
1. Hourly:
a. Load in Amps: Check against Rated figure and balance the load in
3 phases.
b. Voltage: Check against rated figure.
c. Temperature: Oil Temp and ambient Temp.
2. Daily:
a. Silica Gel: Check condition of silica gel and recondition / replace if
required.
3. Monthly:
a. Conservation tank: check oil level and top up if necessary.
b. Humming sound: Check for abnormal humming of Transformer and
attend.
c. Oil leakages: Check and attend the leakage on transformer body,
conservator tank, oil drain valve radiators.
d. Tap changer switch: check for free movement of tap changer switch. Tap
position to be clearly seen.
e. Connections: Check tightness. If loose tighten.
4. Quarterly:
a. Bushings: Check condition of bushings, clean the bushings.
5. Half yearly:
a. Non conservator transformer: check for moisture under cover and improve
ventilation.
b. Cable boxes: check cable boxes (For indoor transformers)
c. Explosion vent diaphragm: check condition of explosion vent diaphragm.
d. Gasket joints: check for oil leakage.
6. Yearly:
a. Oil in Transformer: Check for
i. Dielectric strength.
ii. Water content
iii. Sludge
iv. Acidity
v. Dissolved gases
b. Earth resistance: Measure the earth resistance.
c. Relays, Alarm their circuits: Check functioning of relays, alarm & their
circuit.
7. 2 yearly: Non conservator transformers: Internal inspection above core. Filter oil
regardless of condition.
8. 5 yearly: Over all inspection including lifting of core and coils.
69
14. What is the function of Explosion vent?
Explosion vent is provided for transformer this act as a pressure safety valve & burst
in case excess pressure is developed in the transformer tank.
15. Explain the term Insulation resistance and the procedure for measurement of
the same.
Any electrical equipment can be operated at rated voltage / potentials. Hence it
should be insulated according to potentials to give safety to the operator, so that
potential to be zero on outer surfaces.
Due to moisture – Joints should be tightened and in places where silica gel is provided
should be replaced with pure blue colour.
Due to Low BDV of Oil – New fresh filtered insulating oil with correct BDV is to be
replaced.
Due to defective Insulation tie rod – Correct insulation tie rod is to be provided.
Insulators flash over – Insulators are to be cleaned periodically from dust and other
foreign materials and cementation Part Earthing due to tracking. It should be cleaned
properly.
Due to oil deposits – Oil should be cleaned thoroughly with dry cloth.
70
D.G. SET
17. Briefly explain the working of a diesel engine.
A) Fuel Injection system: The function of this system is to draw fuel from the fuel
tank, clean it, raise its pressure and supply it in form of a high pressure spray at the
proper moment in the cylinders.
B) Cooling System: Only a part of the heat energy of fuel is converted to mechanical
energy in an engine. Due to very high temperature, the engine components gets
heated. This continuous heating may cause some problems. In order to avoid such
problems, the engine cylinders are continuously cooled. There are two types of
cooling systems. Viz., Air cooling and water cooling.
C) Starving system: The crank shaft must be turned by some outside means for the
first few cycles and after which it continuously runs . The types of starting systems
are hand starter, Petrol engine starting, Compressed air motor starting.
. D) Lubricating system: There are many moving parts in an engine such as piston
moving In a cylinder, two ends of connecting rod moving round piston and crank
pins, crank shaft moving on its bearings etc., In order to reduce friction in these parts,
they are to be lubricated. Lubricating oil is stored in the lower part of the engine and
a pump delivers the oil to the different components needing lubrication.
19. List out the moving and stationary parts of a diesel engine.
Cylinder block, Cylinder liners, Dry liners, Wet liners, Cylinder head, Head
gaskets, Exhaust manifold, Crank shaft, Crank case, oil pan, piston, Expansion
control,, piston head shoes, Piston rings, Oil control ring, piston pin, Connecting rod,
Vibration damper, fly wheel, Main bearings, Valve actuating mechanism, Hydraulic
valve lifter, Rocker arm, Cams and Camshaft, gears.
20. Explain the word ignition.
Ignition system is to reduce a spark in the petrol engine cylinder, at the end of the
compression stroke and to ignite the air fuel mixture.
71
21. Explain the objectives of lubrication and the parts that needs lubrication.
23. What are the maintenance records and how they are useful? What records are
to be maintained for a D.G set?
72
24. How diesel engines are rated?
The manufacturers of diesel engines are Supposed to state the break power that their engine
can develop at a given speed. This break power at a particular speed is known as its Rating,
The break power can be expressed either in terms of Horse power of Kilo watts and speed is
expressed in RPM.
Max. Rating: It is the Horse power at a particular speed which the engine can develop for a
short duration ie., 5 mts—30%
Intermittent Rating: It is the Horsepower at a particular speed, which the engine can develop
for about one hour---15%
Continuous Rating: It is the Horse power at a particular speed which the engine develop with
out interruption.
25. Discuss the importance of the preventive maintenance of a diesel engine.
Components of an engine take wear and tear during their work. These components need
periodical checking/servicing/replacement. To facilitate periodical
checking/servicing/replacement of parts, periodical maintenance schedules are made. If such
schedules followed strictly, the chances of unexpected maintenances are rare. The schedules
as well planned maintenance is known as Preventive maintenance there by avoiding the break
down of equipment and work interruption.
26. Explain the cleanliness of the diesel oil.
The diesel engine fuel injection pump and fuel injector are having very close
tolerance. If the diesel sent to these components is clear and chemically satisfactory, there
will be very little wear of these components even after prolonged operating. However it may
not be possible to obtain absolutely clean diesel fuel at the refineries. Hard and sharp foreign
particles available in the oil cause accelerated wear of fuel injection system components.
To minimize such damage due to fuel contamination, extreme care is required during
installation of different fuel lines, for which a no. of filters, water separators are permitted.
27. What are the different checks to be carried out on D.G sets. What are the items to be
checked in ‘A’. Check and explain the nature of check.
1. Lubricating Oil: Check the lubrication oil level in engine and governor and top up if
necessary.
Check the oil bath level.
2. Radiator water: Check radiator water level.
Check oil bath cleaner oil level.
3. Air cleaner oil: Check the condition of pre-cleaner dust pan.
Check the condition of air cleaner restrictions.
4. Fuel System: Check and record fuel oil.
Drain sediment from Fuel Tank.
5. Battery: Clean the battery.
Tight the connection.
6. Switch gear: Check automatic starting switch for its proper functioning.
Clean the D.G Set.
7. D.G Set: Check the condition of belt for its proper tension.
Observe Oil leakages.
Observe abnormal sound.
Record lub oil pressure
Record Voltage
Record Load Current
Record KWH Meter reading.
73
Motors
28. What are the functions of starter?
Ans. The functions of starter are:
(i) To start, and stop the motor
(ii) To limit the starting (or inrush) current, when necessary
(iii) To permit automatic speed control, when required, and
(iv) To protect the induction motor as well as the connected equipments from the
sustained over-load, no-voltage, under-load, etc. Conditions.
74
Ns
Ns=120 x 50
P
=6000 R.P.M.
P
And P= 6000
Ns
34. Explain in brief the working principle of a 3-phase squirrel cage induction
motor.
On connecting the stator windings to a 3-phase source of supply, a 3-phase
rotating magnetic field is developed in the stator. An e.m.f. is induced in the rotor
bars due to which conduction of current is established in the bars which develops a
torque and sets the rotor into rotation.
35. Explain in brief the working of a 3-phase slip-ring induction motor.
The stator of a slip-ring induction motor is identical to a squirrel-cage
induction motor’s stator. The rotor of this type of motor is wound like its stator. The
no. Of poles and phases of rotor-windings are the same as of stator-winding.
The 3 one side terminals of three rotor-windings are joined at one point to
make a star-connection and the other 3 terminals connected to 3 slip-rings. These
slip-rings are connected to an external 3-phase rheostat by means of 3 carbon-
brushes.
The external resistance is added to the rotor winding circuit for increasing the
starting torque and decreasing the starting-current at the time of starting the motor as
shown in the figure. As the motor attains its normal speed, the external resistance is
cut gradually and finally the slip-rings get short-circuited.
If the rotor resistors of a slip-ring induction motor are connected in delta then
a parallel circuit will be formed. Then the total resistance will be smaller than their
individual resistances. Rheostat-resistors connected in delta will not fulfil the
condition of producing high starting torque. Therefore, the rheostat-resistors should be
connected in star only.
Wound-rotors are costlier than squirrel-cage rotors but their starting torque is
much higher than that of squirrel-cage rotors.
36. Write the names of various single phase (φ) motors.
The names of various single phase motors are follows:
(1) Split-phase (φ) motor,
(2) Capacitor motor (a)capacitor-start motor,(b)capacitor-run motor,(C) capacitor-start
capacitor-run motor or double capacitor motor.
(3) Shaded pole motor
(4) Universal motor or A.C. series motor or AC/DC motor
(5) Repulsion motor – (a) plain repulsion motor, (b) repulsion-start induction-run motor,
(c) repulsion induction motor.
37. Why are the single phase (φ) induction motors not self-start?
75
Because of only one phase (φ) winding, there is no rotating magnetic field in a
single phase induction motor. Since, the field has no rotating nature, hence, it is
incapable to rotate the rotor and the motor can’t start by itself.
38. Draw a connection diagram of a capacitor-start induction motor.
41. What may be the possible causes if a capacitor motor begins to emit smoke on
starting?
(1) winding are short-circuited,
(2)Centrifugal switch fails to put ‘OFF’ the running winding,
(3) Bearings are worn out.
Motors which operate on single phase supply and are of generally fractional horse
power with a reading of less than 1 HP.
43. How would you reverse the direction of a rotation of a capacitor start-induction-
run motors?
By reversing either the running or starting-winding leads where they are connected to
the line. Both must not be reversed.
76
44. What is a universal motor?
It is built like a series D.C motor with the difference that both the stator and armature
are laminated. They can be used either on d.c or a.c.
45. What could be the reason if a split phase motor runs too slow?
By single phasing is meant the opening of one wire (or leg) of a three phase circuit.
50. What is jogging?
It means inching a motor i.e. to make it move a little at a time by constant starting
and stopping.
77
Winding of motors. Check for abrasion peeling or cracking or discolouration of
insulation.
Blow out the motor winding with clean dry air. Free ventilation holes.
Insulation resistance. Check insulation resistance to earth & between phases of motors
winding, control gear, etc.
52. What are the various protections provided for motors?
For human safety: Earthing of the motor frame
From Faults: HRC fuses. For protection against short circuit faults.
Overload relay for protection against overloads.
No volt coil for protection against low voltage/ No voltage.
Single phasing preventer for protection against single phasing.
Circuit breakers
Circuit Breaker is a device capable of making and breaking a circuit under normal as
well as under abnormal conditions.
55. Explain maintenance activities carried out on L.T switch gear/Bus bar?
a) Switch OFF panel board and blow out dirt through inside panel and switches.
b) Check & tighten terminals at the Bus bar & switches.
c) Check cable entry for provision of proper insulating bushes at bus bar & switches.
d) Check and clean pitted contacts, check for any overheating/flash marks and
searches for causes.
e) Check and ensure proper earthing to bus bar and switches.
Check and ensure bus bar neutral is rigidly earthed.
56. Define and discuss the following ratings of A.C circuit breaker
a. Rated short circuit breaker current: The rated maximum interrupting
current/breaking current is the RMS value of 3-phase current which can be interrupted
supply by the circuit breaker under fault/short circuit occurred. The value of
maximum breaking current given by the manufacturer should not be exceeded. This
refers to the rupturing capacity of CB for breaking maximum short circuit current
under fault/short circuit condition of safety (Rupturing capacity of CB is generally in
MVA). Here safe interruption means that the time of interruption of CB should not
78
exceed the rated interruption time of CB to avoid damage to the loads. At the same
time CB should be able to withstand for the instantaneous over loads.
b. Rated short circuit making current: The rated making current is the
maximum RMS current against which the breaker is capable of closing and
immediately opening without welding of contacts or any other damage.
57. Describe the following.
1. Temperature rise test: - In this test the rated current through all three phases of
switchgear is passed continuously for a period till a steady state condition is achieved.
Temperature rising at different points is measured and should not be more than 50
degrees centigrade under any circumstances.
2. Mill volt drop test:- This test is used to measure the contact resistance of whole of
CB. The voltage drop across the breaker pole is measured for different values of dc
current. The voltage drop gives a measure of resistance of current carrying part and
contacts. The dc current should be more than 100 amps and less than rated current.
3. Insulation resistance measurement
4. Mechanical endurance tests:- A CB should open and close at the correct speed
and perform such operations without mechanical failure. Hence the breaker
mechanism is subjected to a mechanical endurance type test involving repeated
opening and closing operations. Out of 1000 such operations, 50 Nos are to be
operated by energizing the relay. It should work satisfactorily without failure and
without requirement of adjustment to the operating mechanism. Then only it is
considered that the CB is passed Mechanical endurance test.
5. No load mechanical tests:- Mechanical tests on High voltage CBs are conducted
without current and voltage in the main circuit for 1000 no: of operations of opening
and closing. There should not be any mechanical failure of contacts and mechanism.
Out of 1000, 100 operations are done by connecting main circuit contacts in service
with trip circuit. Then only it is considered that CB is passed under this test.
6. Routine test :- Once a particular design is found satisfactory, a large number of
similar circuit breakers are manufactured for marketing. Every CB is then tested
before putting in service. These tests are known as Routine tests.
7.Type test :- Any equipment when designed to certain specification and is fabricated
needs testing for its performance. The general design is tried/tested and the results of
79
such tests conducted on one selected breaker and are thus applicable to all others of
identical construction. These tests are called type tests.
EARTHING
58. What is the object of earthing?
80
The earth resistance can be considerably reduced by digging around the earth
electrode to a depth of 1.5 or 1 meters, cleaning the surface of the earth plate or pipe
of rust, filling with charcoal soaked in salt solution.
65. Why is Earthing of electrical apparatus necessary?
It is well known that the metallic frames of all electrical equipments should
be solidly connected to earth to drain away the faulty current (Earth leakage)
quickly so that fuse will be blown or Circuit breaker is tripped and to keep the
frame at earth potential to achieve safety to the equipment as well as the staff.
81
67. Explain the procedure for Measurement of Earth Resistance by 3 point method?
C
P
82
Sub-station
68. Draw the lay –out diagram of a 11kV/440V sub-station ?
500kV
A
83
70. What are the various details to be entered in a sub-station log book?
HT.Side
1.Voltage
2. Current
3.Power factor
LT.Side
1. Voltage
2. Current
3. Temperature reading of transformer
4. D.G.Set operting voltage and current, time of operation, temperature
5. Shut down
6. Failures & attention to faults
71. What are the safety items to be available in sub-station.
1. Sand bucket with sand. 6. Safety earthing chains.
2. Fire extinguishers. 7. ‘Men working’ caution
3. First Aid Box with boards.
medicine. 8. ‘Danger’ caution
4. Artificial respiration Boards.
chart. 9. Safety Helmets.
5. Ladders. 10. Safety belts.
72. Describe briefly the purpose of each of the following in Electrical Sub-Station.i)
Lightning Arrestors: A lightning arrestor is a device which protects transformer and
for other electrical Apparatus from an over load of electrical voltage. This overload
can occur either because of lightning or improper switching in the circuit. The
lightning arrestor provides a path over which the overload can pass to the ground
before it has a chance to attack and seriously damage the transformer or other
equipment
ii) Shielding wire: Its main function is to provide shielding to the transmission line
conductors and low height towers against direct strokes of lightning. The shield wire /
ground wire increases the potential of the conductor and reduce the surge stress on
the insulator due to its capacity coupling.
iii) Metal (Ballast) in substation yard: It is used as a safety measure Due to metal
(Ballast) spread in the substation, hazards and deterioration of equipment on account
of stagnation of water is reduced. The growth of grass is considerably reduced
73. Name the functions of the following in a sub-station.
(i) Potential Transformers: Potential transformer is used to measure the high
voltages in a substation in conjunction with standard low range voltmeters, It also
facilitate to operate relays or pilot lights whose ratings are very low. These
transformers are extremely accurate ratio step down transformers.
(ii) Current Transformers: These transformers are used with low range ammeters to
measure currents in high voltage ac circuits. In addition to insulating the instruments
from the high voltage line they step down the currents. (The range of the ammeter is
increased) in a known ratio.
84
(iii) Batteries: Batteries are used in a sub-station for feeding supply to control,
protection and indication circuits. They are also used for operation of circuit breakers
and interrupters and motor operated isolators. They are also used in remote control
centre.
(iv) Isolators with Earthing heels: These are used for making and breaking a circuit
in off load. The isolators are designed to operate without load. The isolators having
an Earthing arrangement such that in the event of opening/switching off a circuit
breaker one of the circuit is earthed automatically which is also an additional safety
aspect.
74. Write the five essential steps involved in effecting shut down.
1. Structure :
a. Check for leaning.
b. Check for any birds nests- Remove if any
c. Paint the structure once in 5 years (Last done date)
2. Anticlimbing Device: Check and ensure availability
3. HT Danger board: Check and ensure availability
85
4. Insulator: Check of chipped / cracked insulator.
5. Jumpers:
a. Check the condition for oxidation and flash marks & for strands cut.
b. Check and ensure provision fo standard PVC insulation sleeves for all
Jumpers.
6. Lighting Arrestor: Check the condition for flash over marks/ cracks.
7. Bird guard lacing: Check the condition.
8. Earth connections: Check for the condition of earth connections for:
i. Structure
ii. Lighting Arrestor(Ensure connections to separate Earth pit)
iii. AB switches and also to its operating handle.
iv. Transformer body and neutral (Double earth with 4 SWG GI wire or
flat)
9. A.B. switches:
i. Check for oxidation of contacts of AB switches.
ii. Check the locking arrangements and attend.
10. H.T. Fuses: Check the condition and ensure proper rating of standard fuse
element is used.
11. Spare HT cable: Check the condition of spare HT cable and cable
termination. Spare cable should be suitably supported and terminals to be earthed.
12. APDISCOM Supply point: Check the APDISCOM structure, Metering
Cubicle and report to APDISCOM officials if any defect is noticed.
76. What are the different types of insulators used in OH lines?
86
8. Conductor: Check it for cut in stands and damage of conductor.
9. Service tapping: Check and ensure proper connections of service tapings.
Check and ensure proper Tension in Service Tapings.
78. During maintenance what items are to be checked on U.G cables.
1. Check the insulation values of cables once in a year.
2. Check underground cables near the poles / structure for any damages and also the
condition of vertical protection pipe.
3. Check for proper earthing of cable armored and cable protection pipe.
79. What are the maintenance aspects to be taken care of oil used in transformer?
1. Oil level should be checked at frequent intervals the cause of any serious loss of oil
investigated.
2. All leaks should be repaired as quickly as possible
3. Oil for topping up should comply with relevant standard specification preferably it
should be from the same source as original oil.
Samples of the oil should be taken at regular intervals and tested for dielectric
strength, acidity and crackle records of these together with top oil temp, should be
kept.
80. What is meant by power factor in A.C. circuit?
(a) The ratio of real power to the apparent power is called power factor.
P.F. = Cos ᶲ
P.F. = resistance
Impedance
81. What are the disadvantages of low P.F.?
87
82. What are the regulations of power line crossings for electrified territory?
and Explain the procedure of modifying power line crossings in case of new
electrification of tracks between Railways and State Government.
These regulations apply to Electrical Over head lines
and on under ground Cables crossing Railway Track.
An Over head line crossing shall normally be at right angles to the Railway
track. In special cases, a deviation up to 30 degrees may be permitted. More
than 30 degrees deviation requires approval from the Electrical Inspectorate of
the Railways.
The steel structure shall normally be galvanized in accordance with IS:2629
– 1966.
The minimum distance of the structure (supporting the crossing span) from the
centre of the nearest Railway track shall be equal to the height of the structure
in meters above ground level plus 6 meters. In special circumstances, the
Electrical Inspectorate may permit a lesser distance being adopted subject to
any conditions, he deemed fit.
The crossing span shall be restricted to 300 meters or 80% of the normal span
for which the structures are designed, which ever is less.
The factor of safety of all structures, conductors, guards, guys and ground
wires used in the crossing shall be as stipulated in the Indian Electricity Rules
1956 (as amended in November 1984).
An over head line crossing over the Railway track already shall be located at
the middle of over head equipment span supported by two adjacent
structures/traction masts. The distance between any of the crossing
conductors and the nearest traction mast or structure under the most adverse
conditions shall not be less than 6 meters.
No over head line crossing shall be located over a Booster transformer,
Traction switching station, Traction Sub-station or a track cabin area location
in the electrified area.
The working of a Railway crane under over head line crossing shall normally
be avoided.
The minimum height above rail level to the lowest portion of any conductor of a
crossing including guard wire under the conditions of maximum sag shall be as
follows:
1. UPTO AND INCLUDING 11 KV NORMALLY BY CABLE
2. ABOVE 11 KV AND UPTP 66 KV 14.10 METERS
3. ABOVE 66 KV AND UPTP 132 KV 14.60 METERS
4. ABOVE 132 KV AND UPTP 220 KV 15.40 METERS
5. ABOVE 220 KV AND UPTP 400 KV 17.90 METERS
6. ABOVE 400 KV AND UPTP 500 KV 19.30 METERS
7. ABOVE 500 KV AND UPTP 800 KV 23.40 METERS
The minimum safe clearance between the height of a a crane jig highest point
and lower crossing conductor shall be as under;
88
NORMAL SYSTEM MIN. SAFELEARENCE
VOLTAGE IM METERS
33 KV --- --- --- --- 1.50
66 KV --- --- --- --- 2.00
110 KV --- --- --- 2.25
132 KV --- --- --- 2.50
220 KV --- --- --- 3.50
400 KV --- --- --- 6.00
500 KV --- --- --- 7.25
800 KV --- --- --- 11.50
A Double set of strain insulators shall be used in cross span.
The supporting structure of the over head line crossing on Railway land shall
be provided with anti climbing device.
Each structure on either side of the crossing span supporting the transmission
/distribution line conductors shall be earthed efficiently by two separate
distinct earths and connections
SEB’s should make all the necessary arrangements at the work spot to
complete the work in the minimum possible time
On the day of the execution, Traffic and power blocks will be taken by the
Railways and after taking the necessary safety precautions, they will
permit the SEB’s to start the work and to complete the work in the least
time duly taking the necessary safety precautions.
After completion of the work, the SEB’s will return the permit to work and
then after satisfying the conditions, Railways will cancel the traffic and
power block.
A certificate of completion is to be submitted to the Railways by the
SEB’s.
Railways will check all the work in accordance with the drawings and
other parameters. And after satisfied, they will give the permission to
charge the line.
The crossings will be charged in the presence of a Railways.
The supervisory charges at the rate of Rupees one lakh per hour or part
there of will be charged from the SEB’s.
89
83. What is meant by low, medium, high and extra high voltages?
--Low : <250V
--Medium : >250V but <650V
--High : >650V but < 33000V
--Extra high : >33000V
84. How the Vertical and Horizontal clearances of power line crossings are to be
measured. Explain permissible limits of vertical clearances up to 132KV EHT
power line crossings?
The horizontal clearances can be measured by means of measuring tape i.e.,
between the centre of track and nearest mast/pole/tower on both the sides of the
track. It can also be measured by a second span of the power line crossings on
both sides of the track.
Vertical clearances can be measured between centre of the conductor and
ground by providing a plumb off with Rope at the centre of the conductor of the
power line crossing/guarding.
85. What are the different types of wiring adopted for house hold wiring? Shich system is
now adopted in Indian Railways?
90
87. Name the parts of a fuse
Ans. Fuse wire, Fuse carriers, Fuse Carrier Contacts, Fuse Base, Fixed Contacts.
89. Explain the the Insulation resistance test between conductors and between conductor
and earth in a wiring installation? Draw a rough diagram?
Ans. Before performing the insulation resistance test of complete installation, the main switch
should be put off, all the fuses should be intact in the distribution box, and the lamps (i.e. load) and
all the switches should be put ON. One terminal of the megger is connected to the earth wire of the
supply or to a water pipe and the other terminal (L) of the megger is connected to one live wire and
together with the neutral of the circuit as shown in Fig. Then the handle of the meggar is rotated at
its normal speed and the reading on the scale is noted. This reading is the insulation resistance
between the conductors and the earth. If the needle of the meggar shows zero reading, it means
that there is a direct connection between the conductors and the earth and that should be removed
before conducting the next test. The reading of the megger should not be less than 50 /no. Of
outlets. In general 1MΩ insulation resistance may be considered as sufficient for the complete
installation.
Insulation Test between Conductors: This test is conducted to find the value of the insulation
resistance between live and neutral conductors and also to locate a short circuit if any in the
complete installation.
The wire connected during the previous test should be removed with the fuse terminal
together with neutral link as shown in Fig.
All the lamps should be removed and the main switch should be put OFF. All the fuses
should be intact and all the switches should be ON. The megger terminals should be connected
across the two main fuse terminals of the installation. The handle of the meggar should be turned at
normal speed. In this test also the result should not be less than 1MΩ. This is the insulation
resistance between live and neutral conductors. However if the reading is zero, it means there is a
short circuit in the wiring which should be removed.
This test should be performed only if the result of the last test is found satisfactory. If
there is any fault in the first test, that must be removed.
91
90. What should be the height of the following:
(1) Single pole switch,
(2) Wall socket,
(3) Batten wiring
(4) Ceiling fan,
(5) Power wall socket
Ans.(1) 1.5 metres.
(2)1.5 metres
(3) 2.3 metres
(4) 2.75 metres
(5) 0.33 metres
93. What tests are to be conducted a) while a wiring is in progress b) After wiring is
completed?
The minimum voltage rating= 2x rated circuit voltage ex. For house wiring,
Voltage rating of D.C megger=2x 250V=500V DC
95. What is the allowable min insulation resistance of house wiring?
Pumps
96. What are the different types of pumps used in Railways?
92
1. Bed plate: This may be of cast iron or welded steel which has provision for
passing of dowel locating pins driven through the pump and motor legs for
easy assembly and correct alignment.
2. Pump Casing: It is made of cast iron and may be split horizontally to
enable removal of the impeller and spindle.
3. Impeller: This is made up of close grained cast iron or cast steel . to
eliminate rusting, impellers are made of gun metal. They are hydraulically
and dynamically balanced.
4. Spindle: This is made of steel. To reduce the leakages, hurts collars, gun
metal sleeves and bronze neck rings are used.
5. Stuffing Box and Gland Packing: This serves two purposes – on the
suction side it prevents leakage of air and on the delivery side leakage of water
under pressure. It has gland bolts, packing material.
6. Bearings: These may be of ball, roller or sleeve type.
Quarterly check
Pump noise Foot valve strainer
Pipe connections and nut/bolts Moving parts for lubrication
Yearly check
Remove impeller, replace if vanes are worn out totally
Replace shaft sleeves, if worn out
Replace gland packing, if worn out
Replace any other worn out part
Replace mechanical seal if damaged.
101. What are the precautions you take while installing.
93
g) The gap at the mouth of the bore well around submersible pump should be
closed.
h) Supporting clamps should be mounted properly.
(b) Horizontal Centrifugal pumps:
a) Foundation and foundation bolts for pump and motor should be ensured as per
the specification.
b) Proper alignment between motor and pump should be ensured.
c) Proper functioning of non return valve should be ensured.
d) Anchoring of suction pipe and priming of pump should be ensured.
e) Lubricating bearing and tightness of gland packing should be ensured.
102. What are the functions of the following in a pumping installation.
(a) Strainer: It is fixed in the suction side which prevents the entry of foreign
matter in the system.
(b) Foot Valve: It is fixed at the bottom of the suction pipe which is useful to
maintain liquid in the suction pipe while in operation and stationary
conditions. Entry of foreign matter in the pumping system can be prevented by
providing a suitable mesh around the foot valve. The foot valve has a hinged
leather faced flap which lifts up during the normal operation, and drops and
closes the opening when pump stops.
(c) Sluice valve: It is provided in the discharge pipe line which is used at the
time of replacement of pumps. In normal operations this should be kept
opened. This is generally provided where a pump is installed below the water
level in a reservoir which gives positive feed in to the pump.
(d) Non-return valve: This should be of robust design and strong enough to
withstand the heavy shocks caused by water hammer action, when the pump is
shut down, and protects centrifugal pump and the foot valve. This valve is
provided in the delivery side of the pipe line.
(e) Vacuum and pressure gauges: Vacuum gauge is used to measure the
pressure below that of atmospheric pressure either in feet or lbs/inch. Pipe
connection to the gauge is taken from the suction inlet to the pump pressure
gauge is provided on the delivery side of the pump to measure out put water
pressure of the pump.
103. Describe the merits and demerits of submersible pumps over vertical
shaft pumps.
Submersible pump can be installed in the bore wells which are not exotically
vertical where as vertical shaft pumps cannot be installed in such cases.
2) The installation of a vertical pump requires the services of an experienced
mechanic since alignment of column pipe and rotating shaft should be very
accurate.
3) In case of oil lubricated vertical pump special attention is required and
maintenance cost is also more than submersible pump.
4) Submersible pumps are more reliable than vertical shaft pumps which has got
various mechanical elements.
5) Submersible pumps can be operated by remote control very easily.
6) Dry running of the submersible pump leads to burning of motor.
104. What are the basic criteria for selection of (i) Submersible
94
pumps (ii) Vertical shaft pumps.
Criteria for pumps selection is :
1. Nature of liquid, water (Raw or tread) or chemicals to be handled.
2. Type of duty required i.e., whether continuous, intermittent or cyclic
3. Present and projected demands and pattern of change in demand.
4. The details of head and flow rate required
5. Type and duration of the availability of the power supply
6. Selecting the operating speed of the pump and suitable drive/driving gears.
7. The efficiency of pumps and consequent influence on power consumption
and the running costs
8. Possible permutations of the parameters of the pumping system, in lading
capacity and number of pumps (With standby) combining them in series
or in parallel
9. Options of different modes of installations and their influence on the civil
and structural costs, on the case of operation and maintenance and on over all
economics.
105. Indicate the type of pumps you select in the following application duly
justifying your selection.
i. Bore well pump for individual domestic water needs = Submersible pump for more
depths and jet pumps for less depth.
ii. Open well near river beds for water supply to colonies, industrial and commercial needs
of high suction lift =Multi stage Centrifugal pumps
iii. Bore well pumps at small Railway premises = Submersible pumps
iv. Open well pump with suction lift of 5 M for Divisional HQ Railway premises =
Monoblock pump
v. Pump for Transfer of HSD oil from drums to Engine tank = Rotary pump
Maximum daily consumption of water for the present and anticipated increase
consumption for the next five years for domestic, commercial, industrial use on
the base of yardsticks approved. On the above basis hourly requirement can be
calculated and curve can be drawn.
Type of fluid to be pumped
Type of source in reservoir / sump, well (Including depth) etc., and then
hydraulic data recorded during the last 15 to 20 years.
Location and capacity of Overhead tank can be derived from the above points.
Route and diameter of the pipe line by considering the utilization for different
places and various types.
Times of requirements.
Power supply availability
Sanction for provision of stand by prime movers.
ii. Ans.
95
Total Head = 212 feet
Water to be pumped = 120 GPM
Therefore Work done required = 120 x 10 x 212 (10lb/gallon)
Efficiency= 70%
HP= 120 x 10 x 212/0.7 x 33000 = 11 HP.
107. Briefly explain the Daily and Half yearly checks to be carried out on mono bloc
pumps.
Daily Maintenance:
1. Gland Packing: Leakage through Gland packing.
2. Bearings: Bearing temperature
3. Sound: Whether any under noise or vibration is present.
4. Readings: Pressure, Voltage and current reading.
TARRIF
108. What is Tariff? Name the different categories of Tariff under which
power are obtained from distribution authorities?
Electrical Tariff represents the basis on which charges are recovered from the
consumers for supply of electricity.
The main objectives of the tariff is to distribute equitably the cost of
supplying electrical energy among the various classification of use such as
lighting, heating, industrial and, bulk supply etc.
The different kinds of tariff in common use are as under:
Simple tariff Max. demand tariff
Flat rate tariff Power factor tariff
Block rate tariff Three part tariff
Two part tariff Off peak tariff
109. (a) Explain (i) Load factor (ii) Diversity factor.
LOAD FACTOR: The load factor is specified with its period viz., daily
load factor, monthly load factor or annual load factor.
96
The annual load factor is defined as the ratio of KWH supplied by the station
in a year divided by the product of peak load and 8760 (The no. of hours in a
year).
= 25,00,000/5 x 10 X 10 X 10 X 24 X 30 X 0.8
= 125/14.4 = 0.86
97
c. Energy charges. Recorded energy units or 250 units for kVA
of CMD whichever is more.
d. P.F. penalty 2 Paise / Unit if the P.F. is below 0.9.
e. P.F. discount 1 Paise/unit if the P.F. is above 0.95.
f. Meter rent Rs. 1500/-
g. MD charges. 1500 / KVA, Energy charges Rs. 420/KWH.
Find the energy bill if the joint readings are as follows for 11 kV
substation having CMD: 2500 kVA.
(a) M.D. = 1200 kVA, KWH=6,00,000 units P.F. = 0.96.
i. MD = 80% of CMD = 80% of 2500 = 2000KVA
MD = 80 % of RMD = 80% of 1200 = 960 KVA
ii. MD penalty = No penalty as RMD is less than CMD
MD charges = Rs 1500 x 2000KVA =Rs30,00,000
iii. Energy charges
Recorded energy units=6,00,000xRs420=
Rs25,20,00,000 is less.
250 units/KVA of CMD=250x2500KVA
= 6,25,000 units.
6,25,000 x RS 420 =Rs 26,25,00,000 is more.
Power factor penalty =Nil
P F discount =1paise/unit x 6,25,000
=Rs 6,250.
BILL: Rs 30,00,000+26,25,00,000+1500-6250
= Rs26,54,95,250.Ans.
FIRE SAFETY
111. What are the reasons for fire occurrence
Enumerate in :
1. Substations:- Due to leakage/spillage of oil from oil drums, Paints and other
inflammables etc coming in contact with electrical sparks of burnt switches,
cables, short circuit of wiring etc,
Anybody throwing a lighted cigarette on the oil drum or used
cotton waste causes fire in substation.
Flashover from switches, circuit breakers, etc also leads to fire in
substations.
112. Why at all a Fire occur
98
comes into contact with spark, etc leads to fire.
iii) Smoking and throwing the lighted butts etc on the
easily combustible material by the passengers will
also lead to fire in coaches.
iv) Some times unsafe use of stoves in pantry cars
leads to fire.
v) Using of oversize fuses, under size cables,
improper/loose terminal connections, tightness of
connections, etc leads to fire in coaches
vi) Bypassing of safety items like fuses, relays etc, low
insulation resistance causing earth leakage, also
leads to fire in coaches.
113. How many types of fire extinguishers are available in your jurisdiction.
There are four types of fire extinguishers
A class: Soda ash cartridges, water buckets, chemical foam, Halon gasses etc.,
B class: Chemical foam, Dry powder, carbon dioxide Halon gas
C class: Dry chemical powder, carbon dioxide, Halon gas
D class: Halon gas, Dry chemical powder, carbon dioxide
114. Classify various types of fires and how do you extinguish them in detail.
99
v) Do not bring naked flame near a battery.
Prevention of accident:-
i) Be cautious. ii) Handle with care.
iii) don’t play with electricity.
iv) Don’t lean on switchboards and electrical equipment.
v) Use safety items viz., safety belts, helmets etc
116. What are the preventive measures to be taken to avoid Fire accidents in
Workshop.
---Use electrical equipments of approved design and from reputed
manufacturer.
---They are to be installed properly, by experienced staff who are fully aware
of their responsibilities and conversant with the statutory rules like IE rules
and regulations for safe working on electric equipments.
---The electrical equipment has to be maintained properly by carryings out
periodical inspections and tests to ensure that the equipment is safe.
--- The equipment has to be used carefully, taking normal precautions .
--- The place of working should be dry and free from inflammable items.
---proper earthing of the equipments is to be done.
---Loose connections and shortcut methods are to be avoided. Hanging wires
and bare wires should not be allowed.
117. What action you will take when fire occurs in a HT Sub-Station?
Ans. On completion of laying, terminating and jointing of the cables, a plan should be
prepared, which should contain the following details of the installation.
a. Type of cables, cross-section area, rated voltage. Details of construction,
cable number and drum number.
b. Year and month of laying.
c. Actual length between joint-to-joint or end.
d. Location of cables and joints in relation to certain fixed reference points, for
example, buildings, hydrant, boundary stones, etc.
100
e. Name of the jointer who carried the jointing work.
f. Date of making joint.
g. Results of original electrical measurements and testing on cable installation.
MAINTENANCE OF CABLES
Repairs of cables generally involve replacement of a section of the defective
cable by a length of new cable and insertion of two straight joints. All repairs and
new joint in connection with repairs should be made in the same manner as joints on
new cables.
In some cases where the insulation has not been damaged severely, or where
moisture has not obtained ingress into the insulation, it may only be necessary to
install a joint at the point of cable failure.
MAINTENANCE OF END TERMINATIONS
Visual inspection of all the cable end termination should be carried out regularly
for any over heating flashing mark, insulation damage etc.
Cable end terminations should be checked for tightness with a suitable torque
wrench/spanner periodically.
Check the cable support clamps, glands for proper position and intactness.
121. What are the points to be attended during POH of battery chargers?
101
3. Inspect the condition of transformer assembly, rectifier assembly, fuse
assembly and wiring.
4. Check condition of bus bar heat sink, main diodes. Replace if found
damaged/defective. The polarity of silicon diode must be checked before
replacement of new diode.
5. Check the condition of transformer winding and other electrical parameter. If
the transformer is found defective, take for rewinding.
6. Check the condition of rotary switches, push buttons. Clean and attend them
for minor repairs. Replace with new one if found burnt/defective. The
terminals of the rotary switch should be kept tightened.
7. Check all fuses and replace with new one if found defective.
8. Remove and clean thoroughly terminal board assembly. Replace components
with new one if found damaged/defective.
9. Check the tapping of the transformer and attend damaged portion.
10. Replace burnt-out/defective wires/cables of terminal board.
11. Remove the Ammeter, Voltmeter and send it to test room for
overhauling and calibration.
12. Check all joints and connections of primary and secondary winding.
13. Check the insulation and earth resistance of the charger.
14. Paint the control panel, if required.
15. Check the electrical parameters such as voltage, current, temperature rise and
record. Also check the performance of the equipment for 4 hours.
122. Enumerate the likely causes for the main fuse blowing out in a battery charging
rectifier?
Ans.
1. Main fuse blowing a. Power rectifier diode may Check diodes and replace.
out be short circuited.
102
123. What are the different types of welding plants?
Ans. The different types of welding plants are: Arc welding plants,CO2 and plasma welding
plants.
124. What will happen if a motor is started with two phases only because of one fuse
being blown off?
Ans. Before starting rewinding, the complete data of the motor should be noted. The data can
be divided into two parts:
(i) Name plate data: Note down the following details:
Make of the motor, No. of phases, Horse power, R.P.M., Voltage, Full-load current,
Frequency, Temperature, etc.
(ii) Re-winding data: Note down the following details:
No. of coils, No. of slots, Turns per coil, No. of coils per group, No. of groups, No. of
poles, Coil-pitch, size of wire, No. of parallel paths, No. of conductors in each coil,
Connections, Insulation used in slots, Insulation used on coils etc.
126. Name the energy efficient measures adopted in lighting?
103
v. Its weight is low.
vi. The choke circuit component can easily be repaired up.
vii. It can work on voltage between 100 to 300 volts.
viii. It doesn’t get hot.
ix. Its life is double.
x. It can work on A.C./D.C. source.
xi. It gives more light.
128. What is the function of a choke in the florescent lamp?
Ans. i. when the starter’s contacts get open due gas glow then the flux of the choke
falls rapidly and a surge voltage of about 1000V is developed. The gas discharge glow is
started in the tube at this high voltage.
ii. when the tube is glowing then it supplies about 110volts to the tube.
iii. it regulates the current at a stable rate during operation of the tube.
104
OBJECTIVE TYPE QUESTIONS ON ELECTRICAL POWER
MAINTENANCE
1. The net resistance of a circuit consists of 4 resistances 1,2,3,4 in series is
___________________.
2. The net resistance of a circuit consists of 4 resistances 1,2,3,4 in parallel is ______________
a. 0.58
b. 0.48
c. 0.40
d. 0.50
3. The best conductor of electricity is
a. Silver
b. Aluminum
c. Brass
d. Zinc
4. The mercury is a _____________ conductor.
a. Solid
b. Liquid
c. Gaseous
d. None of the above
5. Dry air is a
a. Conductor
b. Insulator
c. Semi- conductor
d. None of the above
6. The theoretical water column that can be supported by atmosphere at sea level is
a. 10 feet
b. 24 feet
c. 34 feet
d. None of the above
7. In centrifugal pump water is admitted into the
a. Center of rotor
b. Outer periphery of pump
c. None of the above
8. In a turbine pump the water enters into the pump from
a. Center of rotor
b. Outside opening on the casing
c. None of the above
9. Which of the following pump require priming
a. Centrifugal pump
b. Turbine pump
c. Submersible pump
10. In a submersible pump the motor is located
a. Below the pump
b. Above the pump
c. In the middle
105
11. In a centrifugal pump water is
a. Permitted to enter into the unit and circulate between rotor and stator
b. Not Permitted to enter into the unit and circulate between rotor and stator
12. The bearings in a submersible pump are
a. Water lubricated
b. Oil lubricated
c. Grease lubricated
13. Equipment earthing means
a. Earthing of all metal work of electrical equipment other than live parts
b. Earthing of all metal work of electrical equipment including live parts
14. System earthing is done to
a. Limit the potential of live conductors with earth
b. Increase the potential of live conductors with earth
c. Decrease the potential of live conductors with earth
d. None of the above
15. The meaning of earthing or grounding is to connect the earth point of equipment to general
mass of earth by wire of
a. Negligible resistance
b. Higher resistance
c. Low resistance
d. None of the above
16. The minimum size of G.I pipe electrode used in pipe earthing is
a. 25 mm Dia
b. 40 mm Dia
c. 50 mm Dia
d. 70 mm Dia
17. The minimum distance of earth electrode from a building shall be
a. 1.5 m
b. 0.5 m
c. 2.5 m
d. 2.0 m
18. The maximum permissible earth ‘R’ values for major power stations is
a. 0.5
b. 1.0
c. 2.0
d. 8.0
19. Earth continuity inside an installer from earth plate to any point in the installation is
a. 1.0
b. 2.0
c. 3.0
d. 4.0
20. In maintenance free earthing the electrode is of_________.
106
21. The earthing electrode shall always be placed in
a. Vertical position
b. Horizontal position
c. Any position
22. The minimum size of earth wire is a circuit / sub-circuit should be
a. Equal to size of conductor used in circuit/sub-circuit
b. More than the size of conductor used in circuit/sub-circuit
c. Half of the size of conductor used in circuit/sub-circuit
23. The minimum no. of earth for earthing a transformer separate
a. Two independent earth
b. One earth
c. Three separate & individual earth
24. The distance between two earth electrodes shall be
a. Equal to length & earth electrode
b. Twice the length & earth electrode
c. No distance need to be maintained
25. The earth resistance should be checked once in a year
a. On a dry day during dry season
b. On a dry day during wet season
c. Can be checked anytime
26. The minimum distance to be maintained between the two electrodes of earth megger when
taking reading shall be
a. 20 feet
b. 40 feet
c. 10 feet
d. 75 feet
27. While measuring the earth resistance
a. It is necessary to disconnect the electrode under test from the installation
b. It is not necessary to disconnect the electrode under test from the installation
c. Inter connect all the earth electrodes in vicinity
28. The combined Earth resistance of 33kV/11kV receiving station should not exceed
a) 1 ohm
b) 2 ohms
c) 10 ohms
d) 20 ohms
29. The combined earth resistance of 11kV/415 V Sub-station should not exceed
a) 0.5 ohm
b) 2 ohms
c) 10 ohms
d) 20 ohms
30. As per the present Tariff the minimum power factor of sub-station should be
a) 0.8
b) 0.85
c) 0.90
d) 0.95
107
31.The minimum clearance of lowest conductor from the ground of 33kV lines, across the road
a) 3M
b) 4M
c) 6.1M
d) 14 M
32. The minimum clearance of lowest conductor from the ground of 33 kv lines, along a street
a) 5.8 M
b) 4.0 M
c) 3.0 M
d) 14 M
33. The minimum vertical clearance from 11 KV line to any part of building
a)2.0 M
b)10 M
c) 3.7 M
d) 6.0 M
34. The minimum Horizontal clearance of 11 kV lines from any buildings
a) 1.2 M
b) 3.7 M
c) 6.1 M
d) 10 M
35. The Rod gap on the L.V. side of 11 kV/415V, 250 kVA Transformer is
a) 300 mm.
b) 100 mm.
c) 50 mm
d) Rod gap L.A. is not provided for LV side of Transformer
37. For medium sized 11kV/415v, 500 kVA Transformer sub-station, the type of L.A. used are
a) Station type
b) Line type
c) Distribution type
d) None of these
38. The line type L.A. used for our 11 kV and 33 kV sub-station are having a standard normal
discharge current (peak)
a) 5 KA
b) 10 KA
c) 1.5 KA
d) 2.5 KA
108
39. The span of supports for 11 kV over head lines should not exceed
a) 100 m.
b) 65 m.
c) 30 m.
d) 27 m.
44. In a 11kV / 415 V sub-station the transformer is connected in _______________ to step down
voltage.
a. Star – star
b. Delta – delta
c. Star – delta
d. Delta - star
45. The reason of drawing high current at the time of starting by an induction- motor is:
a) high voltage
b) low power factor
c) zero back e.m.f.
46. In a three phase induction-motor, the speed of rotor is always lesser than that of stator.
109
50. If two transformers have different voltage ratios and their parallel operation is desired then:
a) they can not work.
b) they will work at different power factors.
c) they cannot work on load.
54. The silica jelly used in the breather of a transformer stops the moisture to reach the insulating
oil.
a) rain water
b) dry air
c) moisture
55. If the pump fails to start the likely cause/s is /are
a.) Fuses blown. b). Short circuiting. C). Heavy load on the pump d. )All of the above.
55. A delta-star connected 3-phase transformer is used for high voltage transmission.
59. The power consumption of a 100 watts lamp used 10 hour daily will be:
a) 2 units
b) 1 unit
c) ½ unit
d) 5 units
61. In a self-excited generator residual magnetism is necessary for producing the induced e.m.f.
64. A D.C. over compound generator is useful for transmitting electrical power up to distant places.
110
65. A series motor is always started on load.
66. A starter protects a motor against he damages caused by a heavy current flow.
67. If the field or armature terminals of a d.c. shunt motor reversed then the direction of armature‘s
rotation will change.
69.1 µF is equal to
a) 10-6F
b) 106F
c) 10-3F
d)103 F
78.Vibration dampers are used for controlling the tort ional vibration of the
crankshaft
111
87.Certificate for clearing shut down is issued on form No.EE245.
108. Minimum horizontal distance between power line crossing tower and track shall be
Height of the tower + 6 m
109. Power line crossing tower should be earthed with an earthing electrode (T / F)
TRUE
110. Guarding wire is not required if the system voltage of power line crossing is above
33 KV.
111.Jointing is permitted in the crossing span (T / F). FALSE
112. Inside station limits for B.G. line minimum height above rail of lowest crossing
113. Conductor for system voltages above 66 KV and upto 132 KV at mid span is
14.6 m
114. 11 KV crossing can be overhead type (T / F) FALSE
112
115. If crossing is provided with a guarding, a minimum clearance of _2.0 m shall
be maintained between the bottom of the guard wire and highest traction conductor.
Objective Type:
Sl.No Item To be filled
1. Transformer Secondary Volts = Primary Volts x ( ) (Primary Amps.
Primary turns. Secondary.
Amps. Secondary
Secondary Turns turns).
113