Periferica Truper
Periferica Truper
Periferica Truper
ENGLISH
Instructivo de
Bomba periférica
para agua
Uso agrícola
BOAP-1/2A2
BOAP-3/4A2
BOAP-1A2
BOAP-1/2A2
BOAP-3/4A2
BOAP-1A2
2 ESPAÑOL
Especificaciones técnicas
BOAP-1/2A2 BOAP-3/4A2 BOAP-1A2
Código 12111 12113 12114
Descripción Bomba periférica para agua
Tensión 127 V
Frecuencia 60 Hz
Velocidad 3 450 r/min
Corriente 3,5 A 3,7 A 3,9 A
Potencia 375 W 560 W 750 W
(1/2 Hp) (3/4 Hp) (1 Hp)
Diámetro de entrada y salida 1 NPT
Máxima profundidad de succión 8m
Altura máxima / Valor máximo
40 m 55 m 60 m
de altura manométrica total
Flujo máximo 40 L/min 45 L/min
Temperatura máxima del agua 40 °C
Conductores 18 AWG 17 AWG
Ciclo de trabajo 50 min de trabajo por 20 min de descanso. Máximo 6 h diarias.
Aislamiento Clase I
Grado IP IPX4
El cable de alimentación tiene sujeta-cables tipo: Y
La clase de construcción de la herramienta es: Aislamiento básico.
La clase de aislamiento térmico de los devanados del motor: Clase F.
ADVERTENCIA Si el cable de alimentación se daña, éste debe ser reemplazado por el fabricante o Centro de Servicio
Autorizado , con el fin de evitar algún riesgo de descarga o accidente considerable.
La construcción del aislamiento eléctrico de esta herramienta es alterado por salpicaduras o
derramamiento de líquidos durante su operación. No la exponga a la lluvia, líquidos y/o humedad.
ADVERTENCIA Antes de obtener acceso a las terminales, todos los circuitos de alimentación deben ser desconectados.
Requerimientos eléctricos
ATENCIÓN La conexión a la fuente de energía debe realizarse por un
profesional en electricidad, siguiendo el diagrama eléctrico de la derecha.
Partes
Salida
de agua
a presión Cable de
alimentación
Tapón de
purga
Toma de
agua Soportes
para fijar
a la base
ESPAÑOL 5
Instalación
Montaje
• La bomba debe instalarse en un lugar seco, al resguardo
de la intemperie, que permita el flujo de aire para su
adecuada ventilación (A). Con una temperatura ambiente
que no exceda los 40 °C (104 °F).
• Utilice pernos para fijar la bomba a una base de concreto
para evitar cualquier vibración (B). La bomba debe
instalarse en posición horizontal para asegurar su buen
funcionamiento.
• Los tubos de las líneas de succión y presión deben de
contar con soportes a la pared o piso para evitar la
transmisión de tensión al cuerpo de la bomba (C).
• Tenga cuidado de no dañar la bomba y/o la tubería
debido a un apriete excesivo de las uniones.
C
Línea de succión (entrada)
• El diámetro del tubo de succión no debe ser menor al
diámetro de la toma de agua de la bomba. Si la altura de
la succión excede de 4 m, use un tubo con un diámetro
más grande. E
• El tubo de succión debe de ser completamente
hermético, su extremo debe de estar sumergido en el
agua por lo menos medio metro, en donde se recomienda
F
instalar una válvula de pie (D). El tubo debe de quedar
perfectamente vertical y doblar a 90° hacia la toma de
agua de la bomba. ATENCIÓN De no seguir éstas
indicaciones se formarán cierres de aire y burbujas que
interferirán con el buen desempeño de la bomba.
90°
C B
50 cm (mínimo)
Instalación
incorrecta
Trampa D
de arena
6 ESPAÑOL
Instalación
Conexión eléctrica
• Recurra a un electricista profesional para realizar las
conexiones eléctricas al suministro de energía, cumpliendo
con los reglamentos obligatorios correspondientes.
• La instalación fija debe de incorporar un dispositivo para
asegurar la desconexión omnipolar de la alimentación de
energía.
• Asegúrese de que los requerimientos eléctricos descritos
en éste instructivo y en la placa de la bomba coincidan con
los valores de capacidad del suministro de energía.
• Conecte la bomba a un circuito con tierra física y
después conecte las fases de acuerdo al diagrama eléctrico
de la página 3 o de la placa de la bomba.
• La bomba tiene un motor monofásico, protegido contra
sobrecargas usando un dispositivo térmico (corte de
sobrecorriente) colocado en el devanado.
Puesta en marcha
Purga
H
• La primera vez que ponga en marcha la bomba o
después de un largo periodo de inactividad o cuando haya
entrado aire al sistema debe de llenar la bomba con agua
limpia antes de encenderla.
• Retire el tapón de purga (H) y llene de agua hasta que
llegue al nivel del orificio.
• Atornille el tapón y encienda la bomba.
ADVERTENCIA Nunca ponga en marcha la bomba
cuando esté vacía. Si ocurre esto accidentalmente apague
la bomba de inmediato, espere a que se enfríe y luego
llénela usando agua limpia.
ESPAÑOL 7
Mantenimiento
• La bomba no requiere de mantenimiento siempre y
cuando se tomen las siguientes precauciones:
• Cuando exista riesgo de congelación vacié la bomba por
completo retirando la válvula de pie para que la tubería se
drene.
• Si la bomba permanecerá inactiva por un largo periodo
es recomendable vaciarla por completo, enjuagarla con
agua limpia y almacenarla en un lugar seco.
• Si la flecha no gira libremente utilice un desarmador para
liberarla, insertándolo en el orificio posterior de la bomba (J).
ADVERTENCIA Desconecte la bomba del
suministro de energía antes de realizar trabajos de
mantenimiento.
J
• En caso que la temperatura ambiente este por debajo de
4 °C o que la bomba tenga que dejar de usarse por largo
tiempo, vacié el liquido de la tubería para evitar
congelamiento dentro de la bomba. No opere la bomba
sin agua.
8 ESPAÑOL
Solución de problemas
Problema Causa Solución
El motor no arranca. • No hay energía. • Revise las conexiones y los valores de tensión.
• Impulsor atorado. • Libérelo con un desarmador (consulte la página 8).
Velocidad de flujo • Altura de la succión en el límite. • Disminuya la longitud del tubo de succión.
insuficiente. • Filtro de la válvula de pie • Limpie la válvula de pié y todo el tubo de succión de ser
parcialmente tapado. necesario.
ESPAÑOL 9
Notas
10 ESPAÑOL
Centros de Servicio Autorizados
En caso de tener algún problema para contactar un Centro de Servicio consulte nuestra página www.truper.com
donde obtendrá un listado actualizado, o llame al teléfono: 800 690-6990 ó 800 018-7873 donde le informarán
cuál es el Centro de Servicio Autorizado más cercano.
ESPAÑOL 11
Póliza de Garantía
Este producto, sus piezas y componentes están garantizados por 1 año contra defectos de
fabricación, funcionamiento y mano de obra, excepto cuando: el producto haya sido usado en
condiciones distintas a las recomendadas, o no se haya operado de acuerdo al instructivo, o
haya sido alterado o reparado por personal no autorizado por . Para hacer
válida la garantía o adquirir piezas y componentes deberá presentar el producto y su
comprobante de compra en Av. San Isidro #110, Col. Industrial San Antonio, Alc. Azcapotzalco,
C.P. 02760, CDMX, Méx. o en el establecimiento donde lo compró, o en algún Centro de
Servicio de los enlistados en el anexo de la póliza de garantía y/o en
www.truper.com . Los gastos de transportación que resulten para su cumplimiento serán
cubiertos por . Para dudas o comentarios, llame al 800-690-6990.
Importado por: Truper, S.A. de C.V. , Parque Industrial #1, Jilotepec, Edo. de Méx.,
Méx. C.P. 54240, Hecho en China
1
AÑO
Fecha de entrega:
www.truper.com
12 ESPAÑOL 08-2019
Warranty policy
Models Codes Brand
BOAP-1/2A2 12111
BOAP-3/4A2 12113
BOAP-1A2 12114
This product, its parts and components have a one year warranty against defects in its
manufacture, operation and workmanship, except when: the product has been used in conditions
other than those recommended, or has not been operated according to the instructions, or has
been altered or repaired by personnel not authorized by
Warranty Policy . In order to make the
warranty valid or to purchase components and spare parts, you must present the product and its
proof of purchase at Av. San Isidro #110, Col. Industrial San Antonio, ALC. Azcapotzalco, C.P.
02760, CDMX, Mex. or at the store where you bought it, or at a service center
listed in the attached warranty policy and/or at www.truper.com. Transportation costs resulting
from compliance of this warranty will be covered by . For questions or comments,
call 800-690-6990.
Imported by: Truper, S.A. de C.V. , Parque Industrial #1, Jilotepec, Edo. de Méx.,
Méx. C.P. 54240, Made in China
Stamp of the business:
YEAR
1 Delivery date:
www.truper.com
12 ENGLISH 08-2019
Authorized Service Centers
In the event of any problem contacting a Service Center, please see our webpage www.truper.com to get an
updated list, or call our toll-free numbers (800) 690-6990 or (800) 018-7873 to get information about the
nearest Authorized Service Center.
AGUASCALIENTES DE TODO PARA LA CONSTRUCCIÓN NUEVO LEÓN SUCURSAL MONTERREY
GRAL. BARRAGÁN #1201, COL. GREMIAL, C.P. 20030, AV. STIVA #275, PARQUE INDUSTRIAL STIVA BARRAGAN,
AGUASCALIENTES, AGS. TEL.: 449 994 0537 SAN NICOLAS DE LOS GARZA ,C.P. 66420, MONTERREY,
N.L. TEL.: 81 8352 8791 / 81 8352 8790
BAJA SUCURSAL TIJUANA
CALIFORNIA SUR AV. LA ENCANTADA, LOTE #5, PARQUE INDUSTRIAL EL OAXACA FIX FERRETERÍAS
FLORIDO II, C.P 22244, TIJUANA, B.C. AV. 20 DE NOVIEMBRE #910, COL. CENTRO, C.P. 68300,
TEL.: 664 969 5100 TUXTEPEC, OAX. TEL.: 287 106 3092
FIX FERRETERÍAS PUEBLA SUCURSAL PUEBLA
FELIPE ÁNGELES ESQ. RUIZ CORTÍNEZ S/N, COL. PUEBLO AV PERIFÉRICO #2-A, SAN LORENZO ALMECATLA,
NUEVO, C.P. 23670, CD. CONSTITUCIÓN, B.C.S. C.P. 72710, CUAUTLACINGO, PUE.
TEL.: 613 132 1115 TEL.: 222 282 8282 / 84 / 85 / 86
CAMPECHE TORNILLERÍA Y FERRETERÍA AAA QUERÉTARO ARU HERRAMIENTAS S.A DE C.V.
AV. ÁLVARO OBREGÓN #324, COL. ESPERANZA AV. PUERTO DE VERACRUZ #110, COL. RANCHO DE
C.P. 24080 CAMPECHE, CAMP. TEL.: 981 815 2808 ENMEDIO, C.P. 76842, SAN JUAN DEL RÍO, QRO.
TEL.: 427 268 4544
CHIAPAS FIX FERRETERÍAS
AV. CENTRAL SUR #27, COL. CENTRO, C.P. 30700, QUINTANA ROO FIX FERRETERÍAS
TAPACHULA, CHIS. TEL.: 962 118 4083 CARRETERA FEDERAL MZ. 46 LT. 3 LOCAL 2, COL EJIDAL,
C.P. 77710 PLAYA DEL CARMEN, Q.R.
CHIHUAHUA SUCURSAL CHIHUAHUA TEL.: 984 267 3140
AV. SILVESTRE TERRAZAS #128-11, PARQUE INDUSTRIAL
BAFAR, CARRETERA MÉXICO CUAUHTÉMOC, C.P. 31415, SAN LUIS FIX FERRETERÍAS
CHIHUAHUA, CHIH. TEL. 614 434 0052 POTOSÍ AV. UNIVERSIDAD #1850, COL. EL PASEO, C.P. 78320,
SAN LUIS POTOSÍ, S.L.P. TEL.: 444 822 4341
MÉXICO FIX FERRETERÍAS
CITY EL MONSTRUO DE CORREGIDORA, CORREGIDORA # 22, SINALOA SUCURSAL CULIACÁN
COL. CENTRO, C.P. 06060, CUAUHTÉMOC, CDMX. AV. JESÚS KUMATE SUR #4301, COL. HACIENDA DE LA
TEL: 55 5522 5031 / 5522 4861 MORA, C.P. 80143, CULIACÁN, SIN.
TEL.: 667 173 9139 / 173 8400
COAHUILA SUCURSAL TORREÓN
CALLE METAL MECÁNICA #280, PARQUE INDUSTRIAL SONORA FIX FERRETERÍAS
ORIENTE, C.P. 27278, TORREÓN, COAH. CALLE 5 DE FEBRERO #517, SUR LT. 25 MZ. 10, COL.
TEL.: 871 209 68 23 CENTRO, C.P. 85000, CD. OBREGÓN, SON.
TEL.: 644 413 2392
COLIMA BOMBAS Y MOTORES BYMTESA DE MANZANILLO
BLVD. MIGUEL DE LA MADRID #190, COL. 16 DE TABASCO SUCURSAL VILLAHERMOSA
SEPTIEMBRE, C.P. 28239, MANZANILLO, COL. CALLE HELIO LOTES 1, 2 Y 3 MZ. #1, COL. INDUSTRIAL,
TEL.: 314 332 1986 / 332 8013 2A ETAPA, C.P. 86010, VILLAHERMOSA, TAB.
TEL.: 993 353 7244
DURANGO TORNILLOS ÁGUILA, S.A. DE C.V.
MAZURIO #200, COL. LUIS ECHEVERRÍA, DURANGO, TAMAULIPAS VM ORINGS Y REFACCIONES
DGO.TEL.: 618 817 1946 / 618 818 2844 CALLE ROSITA #527 ENTRE 20 DE NOVIEMBRE Y GRAL.
RODRÍGUEZ, FRACC. REYNOSA, C.P. 88780, REYNOSA,
ESTADO DE SUCURSAL CENTRO JILOTEPEC TAMS. TEL.: 899 926 7552
MÉXICO AV. PARQUE INDUSTRIAL #1-A, JILOTEPEC, C.P. 54240,
JILOTEPEC, EDO. DE MÉX. TLAXCALA SERVICIOS Y HERRAMIENTAS INDUSTRIALES
TEL: 761 782 9101 EXT. 5728 Y 5102 PABLO SIDAR #132, COL . BARRIO DE SAN BARTOLOMÉ,
C.P. 90970, SAN PABLO DEL MONTE, TLAX.
GUANAJUATO CÍA. FERRETERA NUEVO MUNDO S.A. DE C.V. TEL.: 222 271 7502
AV. MÉXICO - JAPÓN #225, CD. INDUSTRIAL, C.P. 38010,
CELAYA, GTO. TEL.: 461 617 7578 / 79 / 80 / 88 VERACRUZ LA CASA DISTRIBUIDORA TRUPER
BLVD. PRIMAVERA. ESQ. HORTENSIA S/N, COL.
GUERRERO CENTRO DE SERVICIO ECLIPSE PRIMAVERA C.P. 93308, POZA RICA, VER.
CALLE PRINCIPAL MZ.1 LT. 1, COL. SANTA FE, C.P. 39010, TEL.: 782 823 8100 / 826 8484
CHILPANCINGO, GRO. TEL.: 747 478 5793
YUCATÁN SUCURSAL MÉRIDA
HIDALGO FERREPRECIOS S.A. DE C.V. CALLE 33 #600 Y 602, LOCALIDAD ITZINCAB Y MULSAY,
LIBERTAD ORIENTE #304 LOCAL 30, INTERIOR DE PASAJE MPIO. UMÁN, C.P. 97390, MÉRIDA, YUC.
ROBLEDO, COL. CENTRO, C.P. 43600, TULANCINGO, TEL.: 999 912 2451
HGO. TEL.: 775 753 6615 / 775 753 6616
JALISCO SUCURSAL GUADALAJARA
AV. ADOLFO B. HORN # 6800, COL: SANTA CRUZ DEL
VALLE, C.P.: 45655, TLAJOMULCO DE ZUÑIGA, JAL.
TEL.: 33 3606 5285 AL 90
MICHOACÁN FIX FERRETERÍAS
AV. PASEO DE LA REPÚBLICA #3140-A, COL.
EX-HACIENDA DE LA HUERTA, C.P. 58050, MORELIA,
MICH. TEL.: 443 334 6858
MORELOS FIX FERRETERÍAS
CAPITÁN ANZURES #95, ESQ. JOSÉ PERDIZ, COL.
CENTRO, C.P. 62740, CUAUTLA, MOR.
TEL.: 735 352 8931
NAYARIT HERRAMIENTAS DE TEPIC
MAZATLAN #117, COL. CENTRO, C.P. 63000, TEPIC, NAY.
TEL.: 311 258 0540
ENGLISH 11
Notes
10 ENGLISH
Troubleshooting
Problem Cause Solution
The motor is not • There is no power • Check the connections and the power values.
starting • The impeller is stuck • Release it with a screwdriver (see page 8)
The motor turns but is • The foot-valve filter is clogged • Clean the filter
not pumping water • Excessive suction height • Shorten the suction pipe length. Check the suction pipe is
hermetic. Double check the foot valve is submerged, at least,
19.6” It is necessary to purge the pump again (see page 7).
• Air in the admission • Check the suction height
Flow speed is • The suction height is in the limit • Shorten the suction pipe length
insufficient • Foot valve filter is partially clogged • Clean the foot valve and the whole suction pipe if necessary
The motor thermal • The motor is overheated • Check voltage and ventilation
protector is activated • The impeller is stuck • Release it with a screwdriver (see page 8).
ENGLISH 9
Maintenance
• The pump does not require maintenance only if
following these simple precautions:
• When there is risk of frost empty the pump completely.
Remove the foot valve to drain the pipes.
• If the pump will remain idle for long periods of time, it
is recommended to empty it completely, rinse with clean
water and store in a dry place.
• If the shaft is not turning freely, use a screwdriver to
release it. Insert the screwdriver in the rear orifice of the
pump (J)
WARNING • Disconnect the pump from the
power supply before carrying out maintenance jobs.
• In the event the environment temperature is below J
104º F, or the pump is going to be idle for long periods
of time, empty the liquid from the pipes to prevent
freezing inside the pump. Do not operate the pump
without water.
8 ENGLISH
Installation
Electrical Installation
• Call a professional electrician to carry out the electric
connection to the power supply, following the mandatory
rules.
• The fixed installation shall incorporate a device to assure
the omnipolar disconnect from the power supply.
• Make sure the electric requirements described in this
Instruction Manual and the pump nameplate, match with
the power supply value capacity.
• Connect the pump into a circuit with physical earth and
then, connect the phases following the electric diagram in
page 3 or the pump nameplate.
• The pump is built with a monophasic motor protected
against overload using a thermal device (overcurrent cut)
built in the winding.
Start Up
Purge
H
• The first time you start the pump or after a long period of
time idle, or when air has entered the system, fill-up the
pump with clean water before starting.
• Remove the purge cap (H) and fill with water until
reaching the level un the orifice.
WARNING • Never start the pump when empty. If
it happens accidentally, turn OFF the pump immediately,
wait for the pump to cool down, then, fill with clean water.
ENGLISH 7
Installation
Mounting
• The pump shall be installed in a dry place, away from the
elements; with air flow to allow air flow for the adequate
ventilation (A)
Ambient temperature not exceeding 104º F
• Use bolts to fix the pump onto a concrete base to
prevent vibrations (B) The pump shall be installed in a
horizontal position to assure it runs properly.
• The suction lines and pressure pipes shall be supported
to the wall or the floor to prevent transmission of tension
to the pump body (C)
• Use care not to damage the pump and / or the pipes due
to excessive tightening of the joints.
C
Suction line (inlet)
• The suction pipes diameter shall not be smaller than the
diameter of the pump water inlet. If the suction height
exceeds 13 ft, use a pipe with a larger diameter.
• The suction pipe shall be completely watertight, the end E
shall be submerged into water at least one meter and a
half, where using a (D). The pipe shall be set totally
vertical and bend to 90º towards the water inlet in the
F
pump.
CAUTION • Failure to follow these indications will
result in air sealing – in and bubbles interfering with the
pump performance.
Pressure line (outlet)
A
• The outlet pipe will need a gate valve (E) to adjust the
required flow speed and pressure. G
• It is recommended to set a check valve (F) between the
pressurized water from the pump and the gate valve to
prevent the unexpected return of water columns exceeding
65 ft
90°
19.6” (minimum) C B
Wrong
installation
Sand trap D
6 ENGLISH
Safety Warnings for
The Use Of Water Pumps
WARNING • Do not install the pump in areas
Adequate Uses where there is danger of explosion or near combustible
• The pump is a stationary device designed to pump clean liquid and gases.
neutral liquids, with no suspended abrasive solids, in WARNING • Do not aim the water jet against the
temperature not higher than 104 ºF Useful for watering device or other electric components. It is a death hazard
orchards, for pumping non aggressive liquids and to due to electric shock.
increase insufficient pressure in aqueducts pressure. CAUTION • Double check the power cable is not
• Periphery pumps are suitable for agricultural applications making contact with water circulating in the pump.
in watering systems by mini aspersion or air pulverization. • Any type of repair shall only be carried out in a
Also, where pressure requirements are higher due to height Authorized Service Center.
in the watering system and the minimum pressure Otherwise, the user is exposed to an electric shock and
requirements for sprayers to function. makes the warranty void.
For these type of applications, centrifugal pumps are not • All the symbols attached to the device shall not be
recommended due to the low pressure managed. removed or cover. All information about the device that is
• The device is in compliance with the most updated safety not legible, shall be replaced immediately,
requirements, only if is used for what it is designed. The • Read and follow the operation instructions before
devise shall only be used under the allowed performance installing and starting the pump. Any malfunction caused
restrictions. by omission of indications in this Manual, may damage the
• Do not use it for explosive liquids, combustibles or pump an makes the warranty void.
aggressive materials, or for substances hazardous to health,
or sewage water.
• Inadequate use or modifications to the device, using
components not approved or tested by the manufacturer
may result in unexpected damage to the device and the
operator and frees the manufacturer from their legal
responsibility.
CAUTION • The pump shall be connected through a
residual current circuit breaker RCCB designed with current
short circuit not higher than 30 mA.
CAUTION • Before connecting, double check the
power supply matches the pump requirements.
CAUTION • Do not install the pump outdoors or near
wet areas. Recommended for watering with atomizers.
Parts
Pressurized
Water Outlet Power
Cord
Purge
Cap
Water
Connection Supports
for fixing into the base
ENGLISH 5
General Power Tools
Safety Warnings
WARNING! Read carefully all safety warnings and instructions listed below. Failure to comply with any of
these warnings may result in electric shock, fire and / or severe damage. Save all warnings and instructions for
future references.
Work area Do not overreach. Keep proper footing and balance at all times.
Keep your work area clean, and well lit. This enables a better control on the tool during unexpected situations.
Cluttered and dark areas may cause accidents.
Dress properly. Do not wear loose clothing or jewelry. Keep
Never use the tool in explosive atmospheres, such as in the hair, clothes and gloves away from the moving parts.
presence of flammable liquids, gases or dust. Loose clothes or long hair may get caught in moving parts.
Sparks generated by power tools may ignite the flammable material.
If you have dust extraction and recollection devices connected
Keep children and bystanders at a safe distance while operating onto the tool, inspect their connections and use them correctly.
the tool. Using these devices reduce dust-related risks.
Distractions may cause loosing control.
Power Tools Use and Care
Electrical Safety Do not force the tool. Use the adequate tool for your
The tool plug must match the power outlet. Never modify application.
the plug in any way. Do not use any adapter plugs with The correct tool delivers a better and safer job at the rate for which it was designed.
grounded power tools.
Modified plugs and different power outlets increase the risk of electric shock. Do not use the tool if the switch is not working properly.
Any power tool that cannot be turned ON or OFF is dangerous and should be
Avoid body contact with grounded surfaces, such as pipes, repaired before operating.
radiators, electric ranges and refrigerators.
The risk of electric shock increases if your body is grounded. Disconnect the tool from the power source and / or battery
before making any adjustments, changing accessories or
Do not expose the tool to rain or wet conditions. storing.
Water entering into the tool increases the risk of electric shock. These measures reduce the risk of accidentally starting the tool.
Do not force the cord. Never use the cord to carry, lift or unplug Store tools out of the reach of children. Do not allow persons
the tool. Keep the cord away from heat, oil, sharp edges or that are not familiar with the tool or its instructions to
moving parts. operate the tool.
Damaged or entangled cords increase the risk of electric shock. Power tools are dangerous in the hands of untrained users.
When operating a tool outdoors, use an extension cord suitable Service the tool. Check the mobile parts are not misaligned or
for outdoor use. stuck. There should not be broken parts or other conditions that
Using an adequate outdoor extension cord reduces the risk of electric shock. may affect its operation. Repair any damage before using the
tool.
If operating the tool in a damp location cannot be avoided, use Most accidents are caused due to poor maintenance to the tools.
a ground fault circuit interrupter (GFCI) protected supply.
Using a GFCI reduces the risk of electric shock. Keep the cutting accessories sharp and clean.
Cutting accessories in good working conditions are less likely to bind and are
Personal safety easier to control.
Stay alert, watch what you are doing and use common sense
when operating a tool. Do not use a power tool while you are Use the tool, components and accessories in accordance with
tired or under the influence of drugs, alcohol or medication. these instructions and the projected way to use it for the type of
A moment of distraction while operating the tool may result in personal injury. tool when in adequate working conditions.
Using the tool for applications different from those it was designed for, could
Use personal protective equipment. Always wear eye result in a hazardous situation.
protection.
Protective equipment such as safety glasses, anti-dust mask, non-skid shoes, Service
hard hats and hearing protection used in the right conditions significantly Repair the tool in a Authorized Service Center
reduce personal injury. using only identical spare parts.
This will ensure that the safety of the power tool is maintained.
Children or people with reduced physical, sensory or mental
Prevent unintentional starting up. Ensure the switch is in the capabilities shall not operate the tool, neither inexperienced
“OFF” position before connecting into the power source and / people or without knowledge in the use of the tool, unless
or battery as well as when carrying the tool. supervised by a person responsible of their safety or if receiving
Transporting power tools with the finger on the switch or connecting power previous instructions about the tool operation.
tools with the switch in the “ON” position may cause accidents. Children shall be kept under supervision to double-check they will not play
with the tool. Tight supervision shall be used with children or disabled
Remove any wrench or vice before turning the power tool on. persons to prevent from using or being close to any household tool.
Wrenches or vices left attached to rotating parts of the tool may result in personal
injury.
This tool is in compliance with
the Official Mexican Standard
(NOM - Norma Oficial Mexicana).
4 ENGLISH
Technical Data
BOAP-1/2A2 BOAP-3/4A2 BOAP-1A2
Code 12111 12113 12114
Description Peripheral Water Pump
Voltage 127 V
Flow 60 Hz
Speed 3 450 RPM
Current 3,5 A 3,7 A 3,9 A
Power 1/2 Hp 3/4 Hp 1 Hp
Outlet and Inlet Diameter 1 NPT
Maximum Suction Depth 26 ft
Maximum Height / Total Manometric
131 ft 180 ft 197 ft
Maximum Height Value
Maximum Flow 10,5 gal/min 11,8 gal/min
Maximum Water Temperature 104 °F
Conductors 18 AWG 17 AWG
Work Cycle 50 minutes’ work per 20 min rest. Maximum 6 hours’ daily
Insultation Class I
Grade IP IPX4
Power Cord Grips used in this product: Type “Y”.
Tool Build Quality: Basic insulation
Thermal insulation on motor winding: Class F
WARNING Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING Before gaining access to the terminals all power sources should be disconnected.
Power Requirements
CAUTION Connection to the energy source shall be carried out by a
professional in electricity, following the diagram to the right.
CAUTION Use a separate electric circuit for the pump. This circuit R
shall not have conductors with a caliber lower than 12 AWG and shall be
protected with a 20 A time delay fuse. Before. connecting the motor to the
current line, double check the voltage is equal to the data in the motor
nameplate. If operated with a lower voltage, the motor will get damaged.
CAUTION The energy cables are coded with the following colors:
Green: Earth
White: Neutral
Black: Line
WARNING All the wiring, electric connections and ground connections in the system shall comply with THE OFFICIAL
MEXICAN STANDARD NOM – 001 – SEDE- ELECTRIC INSTALLATION (USE) or with the local codes and ordinances. The
user shall call a certified electrician. It is recommended to feed the pump with a circuit that includes a differential switch with an
assigned current not higher than 30 mA.
ENGLISH 3
Contents
Technical Data 3 CAUTION
Power Requirements 3 To gain the best performance of
General Power Tool
the tool, prolong the duty life,
Safety Warnings 4 make the Warranty valid if
necessary, and to avoid hazards
Safety Warnings for Using of fatal injuries please read and
Water Pumps 5 understand this Manual before
using the tool.
Parts 5
Keep this manual for future references.
Installation 6
The illustrations in this manual are for reference
Start Up 7 only. They might be different from the real tool.
Maintenance 8
Troubleshooting 9
Notes 10
Authorized Service Centers 11
Warranty Policy 12
BOAP-1/2A2
BOAP-3/4A2
BOAP-1A2
2 ENGLISH
ESPAÑOL
ENGLISH
Manual
Peripheral Agricultural Use
water pump
Applies for:
Models Codes
BOAP-1/2A2 12111
BOAP-3/4A2 12113
BOAP-1A2 12114
BOAP-1/2A2
BOAP-3/4A2
BOAP-1A2
Read this manual thoroughly
CAUTION before using the tool.