An electromagnetic micrometer to measure the wire centering in high- resolution aluminium drift tubes / Cambiaghi, M ; Cardini, A ; Casani, S ; Ferrari, R ; Gaudio, G ; Iuvino, G ; Lanza, A ; Prata, M J
The muon detector of the Atlas experiment at LHC (CERN) consists of 370000 high-resolution drift tubes assembled in multi-layer chambers. To take full advantage of the single-tube resolution, the high- precision external surface of tube end-plugs is used for positioning a layer before gluing. [...]
1999
In : IEEE 1999 Medical Imaging Conference, Seattle, WA, USA, 24 - 30 Oct 1999, pp.72-76 (v.1)
2.
An electromagnetic micrometer to measure the wire centering in high-resolution aluminium drift tubes / Cambiaghi, M ; Cardini, A ; Casani, S ; Ferrari, R ; Gaudio, G ; Iuvino, G ; Lanza, A ; Prata, M J
The muon detector of the Atlas experiment at LHC (CERN) consists of 370000 high-resolution drift tubes assembled in multi-layer chambers. To take full advantage of the single-tube resolution, the high- precision external surface of tube end-plugs is used for positioning a layer before gluing. [...]
1999
In : IEEE 1999 Medical Imaging Conference, Seattle, WA, USA, 24 - 30 Oct 1999, pp.72-6
3.
The Pavia-Romal ATLAS MDT quality control system / Bini, C ; Calabro, D ; Cambiaghi, M ; Cardini, A ; Casani, S ; Ferrari, R ; Gaudio, G ; Giacalone, R ; Iuvino, G ; Lacava, F et al.
The physics at LHC imposes very severe requirements on the ATLAS muon detector, which translates into stringent requirements on drift-tubes wire tensioning, leak current, gas leak and wire positioning. In order to verify all these parameters prior to chamber construction, a dedicated quality control system was completely designed and built by our groups. [...]
2001 - Published in : Nucl. Instrum. Methods Phys. Res., A 461 (2001) 65-7
4.
New CDF End-Plug Calorimeter / Oishi, R
FERMILAB-CONF-2000-036-E.
- 2000.
Full text from Fermilab
5.
Construction and test of the precision drift chambers for the ATLAS muon spectrometer / Bauer, F. (Munich, Max Planck Inst.) ; Blum, W. (Munich, Max Planck Inst.) ; Bratzler, U. (Munich, Max Planck Inst.) ; Dietl, H. (Munich, Max Planck Inst.) ; Kotov, S. (Munich, Max Planck Inst.) ; Kroha, H. (Munich, Max Planck Inst.) ; Lagouri, T. (Munich, Max Planck Inst.) ; Manz, A. (Munich, Max Planck Inst.) ; Ostapchuk, A. (Munich, Max Planck Inst.) ; Richter, Robert (Munich, Max Planck Inst.) et al.
The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 mum with a single-tube resolution of at least 80 mum und a sense wire positioning accuracy of 20 mum (rms). [...]
arXiv:1604.02259; MPI-PHE-2000-029; MPP-2016-073; MPI-PHE-2000-029; MPP-2016-073.- 2001 - 7 p. - Published in : IEEE Trans. Nucl. Sci. 48 (2001) 302 Fulltext: PDF; External link: Preprint
In : 47th IEEE Nuclear Science Symposium and Medical Imaging Conference, Lyons, France, 15 - 20 Oct 2000, pp.5/11-5/15 (v.1)
6.
A prototype wiring automate for the twister/tango based endplug of the ATLAS muon drift tubes / Dumps, R ; Flegel, W ; Linde, Frank L ; Rosset, C ; Rotil, D ; Massaro, G
ATL-MUON-98-267.
- 1998. - 20 p.
Access to fulltext document
7.
Test of the first BIL tracking chamber for the ATLAS muon spectrometer / Avolio, G ; Bagnaia, P ; Baroncelli, A ; Beretta, M ; Bini, C ; Branchini, P ; Cirilli, M ; Iodice, M ; La Rotonda, L ; Lanza, A et al.
The first Barrel Inner Large chamber of the Monitored Drift Tube (MDT) tracking detector for the muon spectrometer of the ATLAS experiment has been tested with a high-energy muon beam. After a description of the MDT characteristics, we present the test beam experimental set-up, the data analysis techniques and discuss the results. [...]
2004 - Published in : Nucl. Instrum. Methods Phys. Res., A 523 (2004) 309-322
8.
Long term stability and uniformity studies of MDT chambers in the H8 2003 system test / Antonelli, M ; Barone, M ; Cerutti, F ; Curatolo, M ; Esposito, B
The drift properties of six-barrel chambers installed on the H8 beam line have been studied. [...]
ATL-MUON-2004-017.
- 2003. - 26 p.
Access to fulltext - Access to fulltext - Access to fulltext
9.
An electromagnetic micrometer to measure wire location inside an ATLAS MDT drift tube / Cambiaghi, M ; Cardini, A ; Ferrari, R ; Gaudio, G
This short memo reports on an electromagnetic system for measuring the wire position inside an ATLAS MDT drift tube with a 2 micron accuracy..
ATL-MUON-98-259.
- 1998. - 5 p.
Access to fulltext document - Access to fulltext document
10.
A QA/QC system to monitor the planarity of the tube layers in MDT chambers construction / Ciapetti, G ; De Zorzi, G ; Giacalone, R ; Montani, L ; Pinci, D
In this note a commercial laser system for the monitoring of the correct placement of the MDT drift tube end-plugs on the assembly combs is described. [...]
ATL-MUON-98-255.
- 1998. - 9 p.
Access to fulltext document - Access to fulltext document

Nenašli ste čo ste hľadali? Skúste Vašu otázku na iných serveroch:
recid:503766 v Amazon
recid:503766 v CERN EDMS
recid:503766 v CERN Intranet
recid:503766 v CiteSeer
recid:503766 v Google Books
recid:503766 v Google Scholar
recid:503766 v Google Web
recid:503766 v IEC
recid:503766 v IHS
recid:503766 v INSPIRE
recid:503766 v ISO
recid:503766 v KISS Books/Journals
recid:503766 v KISS Preprints
recid:503766 v NEBIS
recid:503766 v SLAC Library Catalog