CERN Accélérateur de science

CERN Document Server 2,042 notices trouvées  1 - 10suivantfin  aller vers la notice: La recherche a duré 0.26 secondes. 
1.
Parameters of the preproduction series SiPMs for the CMS HCAL phase I upgrade / Heering, A (Notre Dame U.) ; Musienko, Yu (Notre Dame U. ; Moscow, INR) ; Ruchti, R (Notre Dame U.) ; Wayne, M (Notre Dame U.) ; Karneyeu, A (Moscow, INR) ; Postoev, V (Moscow, INR)
In 2012 the HCAL SiPM photo sensor upgrade was approved for the increased luminosity (5*10 34 ) of SLHC. The upgrade will replace the current hybrid photodiodes (HPDs) with multi-pixel Geiger-mode avalanche photodiodes, also known as silicon photomultipliers (SiPMs). [...]
2016 - 4 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 824 (2016) 115-118
In : Frontier Detectors for Frontier Physics: 13th Pisa Meeting on Advanced Detectors, La Biodola, Isola D'elba, Italy, 24 - 30 May 2015, pp.115-118
2.
Radiation damage studies of silicon photomultipliers for the CMS HCAL phase I upgrade / Musienko, Yu (Notre Dame U.) ; Heering, A (Notre Dame U.) ; Ruchti, R (Notre Dame U.) ; Wayne, M (Notre Dame U.) ; Karneyeu, A (Moscow, INR) ; Postoev, V (Moscow, INR)
Results from a study of the radiation hardness of silicon photomultipliers (SiPMs) are presented. Recently developed high density (>4500 cells/mm 2 ) SiPMs from two manufacturers (Hamamatsu (Japan) and KETEK (Germany) were exposed to 62 MeV protons at fluences up to 1×10 12 protons/cm 2 at the UCL (Belgium) proton cyclotron (LIF irradiation facility). [...]
2015 - 4 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 787 (2015) 319-322
In : 7th International Conference on New Developments in Photodetection, Tours, France, 30 Jun - 4 Jul 2014, pp.319-322
3.
Measurement of parameters of scintillating bars with wavelength-shifting fibres and silicon photomultiplier readout for the SHiP Muon Detector / Baldini, W. (INFN, Ferrara) ; Blondel, A. (Geneva U.) ; Calcaterra, A. (Frascati) ; Jacobsson, R. (CERN) ; Khotjantsev, A. (Moscow, INR) ; Kudenko, Y. (Moscow, INR ; Moscow Phys. Eng. Inst.) ; Kurochka, V. (Moscow, INR) ; Lanfranchi, G. (Frascati) ; Mefodiev, A. (Moscow, INR) ; Mineev, O. (Moscow, INR) et al.
The light yield and the time resolution of different types of 3 m long scintillating bars instrumented with wavelength shifting fibres and read out by different models of silicon photomultipliers have been measured at a test beam at the T9 area at the CERN Proton Synchrotron. The results obtained with different configurations are presented. [...]
arXiv:1612.01125.- 2017-03-07 - 20 p. - Published in : JINST 12 (2017) P03005 Fulltext: 10.1088_1748-0221_12_03_P03005 - PDF; arXiv:1612.01125_3 - PDF; arXiv:1612.01125_2 - PDF; arXiv:1612.01125 - PDF; IOP Open Access article: PDF; External links: 00009 Light yield scan across 3 cm, 5 cm and 10 cm bars (a). Attenuation of scintillating light in the opposite directions from a fibre in the 10 cm bar (b).; 00006 Sum of the light yield measured at each as a function of the beam position along the bar for L2, L1, L4 bar.; 00004 L2 bar: light yield measured at each end (red squares and blue solid circles) and the sum of the light yields measured at both ends (black open circles) as a function of the incident beam position along the bar.; 00003 L1 bar: light yield measured at each end (red squares and blue solid circles) and the sum of the light yields at both ends (black open circles) as a function of the incident beam position along the bar.; 00007 Light yield scan for 3 cm bars U1 (a) and 5 cm bars U2 (b).; 00002 Example of distribution of the sum of the light yield collected at both ends of a 2 cm thick NICADD bar.; 00014 L2 bar time resolution using only SiPM $L$($R$), red circles(blue squares) and both SiPMs (green triangles).; 00013 L1 bar time resolution using only SiPM $L$($R$), red circles(blue squares) and both SiPMs (green triangles).; 00015 L4 bar time resolution using only SiPM $L$($R$), red circles(blue squares) and both SiPMs (green triangles).; 00001 Example of MPPC spectrum used for the calibration of the light yield.; 00008 Light yield scan for 10 cm bars U3 (a) and U4 (b).; 00000 Four types of bars manufactured at UNIPLAST factory.; 00018 Time resolution for 10 cm bars with 2 MPPC readout (a) and 4 MPPC readout (b).; 00017 Time resolution for 3 cm (a) and 5 cm bars (b) vs position along the bars.; 00011 Example of baseline-subtracted waveform for 2 cm thick NICADD bars.; 00010 The inefficiency for 3 and 5 cm wide bars as a function of the charge detection threshold. The events are counted if the charge is over the specified threshold at each bar end.; 00005 L4 bar: light yield measured at each end (red squares and blue solid circles) and the sum of the light yields measured at both ends (black open circles) as a function of the beam position along the bar.; 00016 Fitting of digitized pulse shape to obtain the timing mark.; 00012 Speed of light propagation $v_f$ in L2 fibre, for signals read by SiPM left (red line) and right (blue line); $v_f$ is measured as $(16.0\pm0.1)$ cm/ns.
4.
Performance studies of the hodoscope prototype for the NA62 experiment / Duk, V (INFN, Perugia ; Moscow, INR) ; Kholodenko, S (Serpukhov, IHEP) ; Fedotov, S (Moscow, INR) ; Giorgi, M (INFN, Pisa) ; Gushchin, E (Moscow, INR) ; Khudyakov, A (Moscow, INR) ; Kleymenova, A (Moscow, INR ; Moscow Phys. Eng. Inst.) ; Kudenko, Y (Moscow, INR ; Moscow Phys. Eng. Inst. ; Moscow, MIPT) ; Kurshetsov, V (Serpukhov, IHEP) ; Mannelli, I (INFN, Pisa) et al.
A hodoscope prototype to detect charged particles in the NA62 experiment at CERN SPS has been installed within the experimental setup in 2014 and exposed to the beam during the data taking period. Efficiency and time resolution for hodoscope tiles are measured. [...]
2016 - Published in : JINST 11 (2016) P06001
5.
Scintillator Tile Hadron Calorimeter with Novel SiPM Readout / Danilov, M. (Moscow, ITEP) /CALICE Collaboration
The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors - Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a large scale. [...]
arXiv:0704.3514.- 2007 - 6 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 581 (2007) 451-456
Preprint: PDF; External link: Preprint
In : 11th Vienna Conference on Instrumentation, Vienna, Austria, 19 - 24 Feb 2007, pp.451-456
6.
Meetings with Hamamatsu to discuss Phase 2 upgrade SiPMs - Phase 2 upgrade SiPMs meeting   20 Jan - 21 Feb 2020  - Solothurn, Switzerland  .-
2020
7.
The CALICE Tile Hadron Calorimeter Prototype With SiPM Readout: Design, Construction and First Test Beam Results / Wattimena, N (DESY) /CALICE Collaboration
The CALICE collaboration has constructed a test beam hadronic calorimeter (HCAL) with 7608 scintillator tiles, individually read out by novel multi-pixel Geiger mode photodiodes, so called SiPMs, and tested it in electron and hadron beams at CERN. This prototype is the first device which uses SiPMs on a large scale; its purpose is to establish the technology and to record hadron shower data with unprecedented granularity for the validation of simulation models and the development of clustering algorithms..
2008 - Published in : 10.1142/9789812819093_0067
In : 10th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications, Villa Olmo, Como, Italy, 8 - 12 Oct 2007, pp.381-385
8.

CERN-PHOTO-202012-177
© 2020-2022 CERN
Working on CMS HCAL electronics
CMS team working on new endcap control electronics [...]
17-12-2020
More >>
9.
First results from the CMS SiPM-based hadronic endcap calorimeter / De Guio, Federico (Texas Tech.) /CMS Collaboration
The CMS hadronic calorimeter employs a plastic-scintillator-based endcap detector. In early 2017, a 20$^{\circ}$ wedge of the endcap was upgraded with silicon photomultipliers (SiPMs) and readout electronics based on the QIE11 digitizer. [...]
CMS-CR-2018-163.- Geneva : CERN, 2019 - 8 p. - Published in : J. Phys.: Conf. Ser. 1162 (2019) 012009 Fulltext: PDF; Published fulltext: PDF;
In : 18th International Conference on Calorimetry in Particle Physics, Eugene, Usa, 21 - 25 May 2018, pp.012009
10.
Plastic scintillator detector with the readout based on an array of large-area SiPMs for the ND280/T2K upgrade and SHiP experiments / Korzenev, A. (Geneva U.) ; Betancourt, C. (Zurich U.) ; Blondel, A. (Geneva U.) ; Breton, D. (Orsay, LAL) ; Datwyler, A. (Zurich U.) ; Gascon, D. (ICC, Barcelona U.) ; Gomez, S. (ICC, Barcelona U.) ; Khabibullin, M. (Moscow, INR) ; Kudenko, Y. (Moscow, INR ; Moscow, MIPT ; Moscow Phys. Eng. Inst.) ; Maalmi, J. (Orsay, LAL) et al.
Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle identification via time-of-flight measurements. [...]
arXiv:1901.07785; JPS Conf. Proc. 27; 011005 (2019).- 2019 - 6 p. - Published in : JPS Conf. Proc. 27 (2019) 011005 Fulltext: 1901.07785 - PDF; fulltext1716502 - PDF;
In : PD18 5th International Workshop on New Photon-Detectors, Tokyo, Japan, 27 - 29 Nov 2018, pp.011005

Vous n'avez pas trouvé ce que vous avez cherché? Essayez votre requête sur d'autres serveurs:
recid:2267903 dans Amazon
recid:2267903 dans CERN EDMS
recid:2267903 dans CERN Intranet
recid:2267903 dans CiteSeer
recid:2267903 dans Google Books
recid:2267903 dans Google Scholar
recid:2267903 dans Google Web
recid:2267903 dans IEC
recid:2267903 dans IHS
recid:2267903 dans INSPIRE
recid:2267903 dans ISO
recid:2267903 dans KISS Books/Journals
recid:2267903 dans KISS Preprints
recid:2267903 dans NEBIS
recid:2267903 dans SLAC Library Catalog