-
Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)
Authors:
X. Shi,
M. K. Ayoub,
J. Barreiro Guimarães da Costa,
H. Cui,
R. Kiuchi,
Y. Fan,
S. Han,
Y. Huang,
M. Jing,
Z. Liang,
B. Liu,
J. Liu,
F. Lyu,
B. Qi,
K. Ran,
L. Shan,
L. Shi,
Y. Tan,
K. Wu,
S. Xiao,
T. Yang,
Y. Yang,
C. Yu,
M. Zhao,
X. Zhuang
, et al. (52 additional authors not shown)
Abstract:
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the co…
▽ More
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.
△ Less
Submitted 28 April, 2020;
originally announced April 2020.
-
Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector
Authors:
X. Yang,
S. Alderweireldt,
N. Atanov,
M. K. Ayoub,
J. Barreiro Guimaraes da Costa,
L. Castillo Garcia,
H. Chen,
S. Christie,
V. Cindro,
H. Cui,
G. D'Amen,
Y. Davydov,
Y. Y. Fan,
Z. Galloway,
J. J. Ge,
C. Gee,
G. Giacomini,
E. L. Gkougkousis,
C. Grieco,
S. Grinstein,
J. Grosse-Knetter,
S. Guindon,
S. Han,
A. Howard,
Y. P. Huang
, et al. (54 additional authors not shown)
Abstract:
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising…
▽ More
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.
△ Less
Submitted 31 March, 2020;
originally announced March 2020.
-
Recent Results from Polycrystalline CVD Diamond Detectors
Authors:
RD42 Collaboration,
L. Bäni,
A. Alexopoulos,
M. Artuso,
F. Bachmair,
M. Bartosik,
H. Beck,
V. Bellini,
V. Belyaev,
B. Bentele,
A. Bes,
J. -M. Brom,
M. Bruzzi,
G. Chiodini,
D. Chren,
V. Cindro,
G. Claus,
J. Collot,
J. Cumalat,
A. Dabrowski,
R. D'Alessandro,
D. Dauvergne,
W. de Boer,
C. Dorfer,
M. Dünser
, et al. (87 additional authors not shown)
Abstract:
Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse hei…
▽ More
Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse height versus particle rate of unirradiated and irradiated polycrystalline CVD (pCVD) diamond pad detectors up to a particle flux of $20\,\mathrm{MHz/cm^2}$ and a fluence up to $4 \times 10^{15}\,n/\mathrm{cm^2}$.
△ Less
Submitted 16 October, 2019;
originally announced October 2019.
-
EUDAQ $-$ A Data Acquisition Software Framework for Common Beam Telescopes
Authors:
P. Ahlburg,
S. Arfaoui,
J. -H. Arling,
H. Augustin,
D. Barney,
M. Benoit,
T. Bisanz,
E. Corrin,
D. Cussans,
D. Dannheim,
J. Dreyling-Eschweiler,
T. Eichhorn,
A. Fiergolski,
I. -M. Gregor,
J. Grosse-Knetter,
D. Haas,
L. Huth,
A. Irles,
H. Jansen,
J. Janssen,
M. Keil,
J. S. Keller,
M. Kiehn,
H. J. Kim,
J. Kroll
, et al. (32 additional authors not shown)
Abstract:
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed…
▽ More
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications.
△ Less
Submitted 18 November, 2019; v1 submitted 30 September, 2019;
originally announced September 2019.
-
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
Subpixel Mapping and Test Beam Studies with a HV2FEI4v2 CMOS-Sensor-Hybrid Module for the ATLAS Inner Detector Upgrade
Authors:
T. Bisanz,
J. Große-Knetter,
A. Quadt,
J. Rieger,
J. Weingarten
Abstract:
The upgrade to the High Luminosity Large Hadron Collider will pose unprecedented challenges to the tracking systems of all experiments. Recent advancement of active pixel detectors designed in CMOS processes provide attractive alternatives to the well-established hybrid design using passive sensors. This article presents studies with a high-voltage CMOS active pixel sensor designed for the ATLAS t…
▽ More
The upgrade to the High Luminosity Large Hadron Collider will pose unprecedented challenges to the tracking systems of all experiments. Recent advancement of active pixel detectors designed in CMOS processes provide attractive alternatives to the well-established hybrid design using passive sensors. This article presents studies with a high-voltage CMOS active pixel sensor designed for the ATLAS tracker upgrade. The sensor is glued to the read-out chip of the Insertable B-Layer. The device under test is structured in smaller pixels than those of the attached read-out chip with information on the hit CMOS pixel encoded in the output signal (subpixel encoding). Test beam measurements mapping recorded hits in the read-out chip to CMOS pixels, thus validating the subpixel encoding, are described.
△ Less
Submitted 6 February, 2017;
originally announced February 2017.
-
On the Response of an OST to a Point-like Heat Source
Authors:
A. Quadt,
B. Schröder,
M. Uhrmacher,
J. Weingarten,
B. Willenberg,
H. Vennekate
Abstract:
A new technique of superconducting cavity diagnostics has been introduced by D. Hartrill at Cornell University, Ithaca, USA. Oscillating Superleak Transducers (OST) detect the heat transferred from a cavity's quench point via "Second Sound" through the superfluid He bath, needed to cool the superconducting cavity. The observed response of an OST is a complex, but reproducible pattern of oscillatio…
▽ More
A new technique of superconducting cavity diagnostics has been introduced by D. Hartrill at Cornell University, Ithaca, USA. Oscillating Superleak Transducers (OST) detect the heat transferred from a cavity's quench point via "Second Sound" through the superfluid He bath, needed to cool the superconducting cavity. The observed response of an OST is a complex, but reproducible pattern of oscillations. A small helium evaporation cryostat was built which allows the investigation of the response of an OST in greater detail. The distance between a point-like electrical heater and the OST can be varied. The OST can be mounted either parallel or perpendicular to the plate, housing the heat source. If the artificial quench-point releases an amount of energy compatible to a real quench spot on a cavity's surface, the OST signal starts with a negative pulse, which is usually strong enough to allow automatic detection. Furthermore, the reflection of the Second Sound on the wall is observed. A reflection coefficient R = 0.39 +- 0.05 of the glass wall is measured. This excludes a strong influence of multiple reflections in the complex OST response. Fourier analyses show three main frequencies, found in all OST spectra. They can be interpreted as modes of an oscillating circular membrane.
△ Less
Submitted 23 November, 2011;
originally announced November 2011.