Skip to main content

Showing 1–13 of 13 results for author: Ovchinnikov, B M

Searching in archive physics. Search in all archives.
.
  1. arXiv:2112.12069  [pdf

    physics.soc-ph

    The arctic electric power stations are the decision of energy, environmental and climate problems

    Authors: B. M. Ovchinnikov, Yu. B. Ovchinnikov, V. V. Parusov

    Abstract: In this paper we propose the decision of energy, environmental and climate problems of the society with the help of arctic electric power stations. Such stations can provide the electricity to the whole of Europe and Asian, this can save from dependence on oil and gas. This method of producing electricity is completely ecologically safe. Keywords: electrical engineering, power station, design, gen… ▽ More

    Submitted 14 December, 2021; originally announced December 2021.

    Comments: 7 pages, 5 figures

    Journal ref: International Journal of Energy Science and Engineering Vol. 3, No. 5, 2017, pp. 44-47

  2. arXiv:2111.10231  [pdf

    physics.med-ph

    The method of inhalation therapy with micro-doses of mixtures noble gases with oxygen

    Authors: A. Yu. Perov, B. M. Ovchinnikov, V. V. Parusov, A. V. Bobrovnikov, V. G. Safronova, Yu. D. Holodilin

    Abstract: In this research, we presented the method of inhalation therapy with noble gas micro-doses and results of clinical studies in hospital of Russian Academy of Sciences (RAS). We have designed a device that allows dosed injection of noble gas with a volume of about 2-4 ml with peroxide vapors into the nasal cavity. After testing on the authors of the project and obtaining a positive impact of xenon a… ▽ More

    Submitted 20 January, 2022; v1 submitted 18 November, 2021; originally announced November 2021.

    Comments: 6 pages, 5 figures

  3. arXiv:2103.06038  [pdf

    physics.ins-det astro-ph.IM hep-ex

    GEM-based detectors for direct detection of low-mass WIMP, solar axions and narrow resonances (quarks)

    Authors: B. M. Ovchinnikov, V. V. Parusov

    Abstract: Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between electrodes are created. The chambers containing MGEMs (WGEMs) with pin-anodes are proposed as detectors for searching of spin-dependent interactions between Dark Matter (DM) particles and gases with nonzero-spin nuclei (1H, D2, 3He, 19F, 21Ne, 129Xe, 131Xe,etc.In this paper… ▽ More

    Submitted 12 April, 2023; v1 submitted 10 March, 2021; originally announced March 2021.

    Comments: 30 pages,20 figures. arXiv admin note: text overlap with arXiv:2006.06401

  4. arXiv:2006.06401  [pdf

    physics.ins-det

    Gas electron multipliers with metal electrodes and their applications in detectors

    Authors: B. M. Ovchinnikov, V. V. Parusov

    Abstract: Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted leakage currents and spark breakdowns between the electrodes. Accidental spark events in such MGEM don't lead to their failure as far as positive ions quickly mov… ▽ More

    Submitted 5 June, 2020; originally announced June 2020.

    Comments: 15pages,6figures

  5. arXiv:1603.05649  [pdf

    physics.ins-det

    Detection chamber for search of low Mass WIMP and solar axions

    Authors: B. M. Ovchinnikov, V. V. Parusov

    Abstract: A chamber for direct detection of WIMPs with masses < 10 GeV/c2 and solar axions is developed. The chamber is filled with a gas mixture of H2 +3ppm TMAE (1,5,10 bar), or D2 + 3ppm TMAE. These gas fillings make it possible to suppress an electron background. For detection of events, the system GEM+pin-anode with a multiplication coefficient of about 10E+05 is constructed.

    Submitted 17 March, 2016; originally announced March 2016.

    Comments: 5 pages,2 figures, submitted to UJPA(HRPAB)

  6. Massive liquid Ar and Xe detectors for direct Dark Matter searches

    Authors: B. M. Ovchinnikov, Yu. B. Ovchinnikov, V. V. Parusov

    Abstract: A novel experiment for direct searches of the Dark Matter with liquid argon double-phase chamber with a mass of liquid Ar up to several hundred tons is proposed. To suppress the b-, g- and n0- backgrounds, the comparison of scintillation and ionization signals for every event is suggested. The addition in liquid Ar of photosensitive Ge(CH3)4 or C2H4 and suppression of triplet component of scintill… ▽ More

    Submitted 2 April, 2012; v1 submitted 17 February, 2011; originally announced February 2011.

    Comments: 8 pages, 2 figures, 1 table

  7. arXiv:1012.4716  [pdf

    physics.ins-det

    Gas Electron Multiplier detectors with high reliability and stability

    Authors: B. M. Ovchinnikov, V. V. Parusov, Yu. B. Ovchinnikov

    Abstract: The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their increased stability and reliability. The experimental results on testing of such detectors with gaps between the electrodes of 1 and 3 mm are reported. It is dem… ▽ More

    Submitted 21 December, 2010; originally announced December 2010.

    Comments: 10 pages, 13 figures, 1 table

  8. arXiv:1006.2986  [pdf

    physics.ins-det nucl-ex

    Multi-channel gas electron multiplier with metallic electrodes

    Authors: B. M. Ovchinnikov, V. V. Parusov, Yu. B. Ovchinnikov

    Abstract: The design of multi-channel gas electron multiplier (MGEM) with metallic electrodes is proposed, produced and tested. The electrodes of MGEM are produced from the brass plates with thickness of 1 mm, round openings of 1 mm in diameter and 1.5 mm steps between them. The gap between the electrodes is equal to 3 mm, while the total working area has a diameter of 20 mm. The neon gas fillings of the MW… ▽ More

    Submitted 16 June, 2010; v1 submitted 15 June, 2010; originally announced June 2010.

    Comments: 9 pages, 4 figures, 1 table

  9. arXiv:1005.1556  [pdf

    physics.ins-det nucl-ex

    Multi-channel wire gas electron multipliers with gaps between the electrodes of 1 and 3mm

    Authors: B. M. Ovchinnikov, V. V. Parusov, Yu. B. Ovchinnikov

    Abstract: Multi-channel wire gas electron multipliers (MWGEM) with gaps between the electrodes of 1 and 3mm were investigated. The chamber of the MWGEM was filled with pure commercial neon gas at pressure of 0.4 or 1.0 bar and irradiated by alpha-particles (Pu-239) or beta-particles (Ni-63). The following maximal coefficients of electrons proportional multiplication have been obtained: 6 \times 10^3 (alpha… ▽ More

    Submitted 10 May, 2010; originally announced May 2010.

    Comments: 7 pages, 2 figures

  10. arXiv:1003.1240  [pdf

    physics.ins-det physics.acc-ph

    A multi-channel wire gas electron multiplier

    Authors: B. M. Ovchinnikov, V. V. Parusov, Yu. B. Ovchinnikov

    Abstract: A novel and relatively simple method of production of electrodes for a multi-channel wire gas multiplier is developed. Two modifications of the multipliers have been tested: with a multiplication of electrons between two wire electrodes, MWGEM, and between a wire electrode and continuous anode, MWCAT. For both MWGEM and MWCAT detectors, filled with neon under pressure of 760 Torr and irradiated… ▽ More

    Submitted 5 March, 2010; originally announced March 2010.

    Comments: 4 pages, 9 figures

    Journal ref: Instrum.Exp.Tech.53:653-656,2010; Prib.Tekh.Eksp.5:37-40,2010

  11. arXiv:0911.4811  [pdf

    physics.ins-det

    Wire GEM detector

    Authors: B. M. Ovchinnikov, V. I. Razin, A. I. Reshetin, S. N. Filippov

    Abstract: A wire GEM (WGEM) detector with a gas gap between meshes was constructed. The detector provides the amplification 5x10E5 for the gas mixture of Ar +20% CO2 at atmospheric pressure. As compared with well-known GEM detectors produced by perforation the plastic plate metalized on both sides the WGEM does not suffer from breakdowns between its electrodes and the effect of accumulation of charges on… ▽ More

    Submitted 25 November, 2009; originally announced November 2009.

    Comments: Presented at the RD51 Collaboration Meeting, CERN, November 2009, submitted to the Prib. Tech. Exper

  12. arXiv:0911.4807  [pdf

    physics.ins-det

    RETGEM with polyvinylchloride (PVC) electrodes

    Authors: V. I. Razin, B. M. Ovchinnikov, A. I. Reshetin, S. N. Filippov

    Abstract: This paper presents a new design of the RETGEM (Resistive Electrode Thick GEM) based on electrodes made of a polyvinylchloride material (PVC). Our device can operate with gains of 10E5 as a conventional TGEM at low counting rates and as RPC in the case of high counting rates without of the transit to the violent sparks. The distinct feature of present RETGEM is the absent of the metal coating an… ▽ More

    Submitted 25 November, 2009; originally announced November 2009.

    Comments: Presented at the RD51 Collaboration Meeting, CERN, November 2009

  13. arXiv:physics/0105107  [pdf

    physics.ins-det physics.plasm-ph

    Investigation of the proportional discharge mechanism in nonelectronegative gases

    Authors: B. M. Ovchinnikov, V. V. Parusov, Yu. B. Ovchinnikov

    Abstract: A shape of the signals in proportional chamber with preamplification gap and electron component extraction from proportional discharge has been investigated. It was shown for Penning mixtures that in proportional discharge besides the primary avalanches there is also the tail of secondary avalanches caused by metastable and nonmetastable Penning effects. For different mixtures of gases the durat… ▽ More

    Submitted 31 May, 2001; originally announced May 2001.

    Comments: 13 pages, 8 figures