Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer
Authors:
David J. Mercer,
Ryan Winkler,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Krystal I. de Castro,
Eric A. Feissle,
Joseph W. Fowler,
Johnathon D. Gard,
John A. B. Mates,
Daniel G. McNeel,
Nathan J. Ortiz,
Daniel Schmidt,
Katherine A. Schreiber,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Sophie L. Weidenbenner,
Abigail L. Wessels
Abstract:
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter…
▽ More
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter gamma-ray spectrometer. For the 103-keV gamma ray we report an improved centroid energy and emission probability.
△ Less
Submitted 8 July, 2022; v1 submitted 6 February, 2022;
originally announced February 2022.
-
Improved Plutonium and Americium Photon Branching Ratios from Microcalorimeter Gamma Spectroscopy
Authors:
Michael D. Yoho,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Johnathon D. Gard,
J. A. Ben Mates,
David J. Mercer,
Nathan J. Ortiz,
Daniel R. Schmidt,
Chandler M. Smith,
Daniel S. Swetz,
Aidan D. Tollefson,
Joel N. Ullom,
Leila R. Vale,
Abigail L. Wessels,
Duc T. Vo
Abstract:
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-h…
▽ More
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium (238Pu,239Pu,241Pu) and 241Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. We show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2{3 for four branching ratios.
△ Less
Submitted 22 June, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.
-
First application of superconducting transition-edge-sensor microcalorimeters to hadronic-atom x-ray spectroscopy
Authors:
S. Okada,
D. A. Bennett,
C. Curceanu,
W. B. Doriese,
J. W. Fowler,
J. Gard,
F. P. Gustafsson,
T. Hashimoto,
R. S. Hayano,
S. Hirenzaki,
J. P. Hays-Wehle,
G. C. Hilton,
N. Ikeno,
M. Iliescu,
S. Ishimoto,
K. Itahashi,
M. Iwasaki,
T. Koike,
K. Kuwabara,
Y. Ma,
J. Marton,
H. Noda,
G. C. O'Neil,
H. Outa,
C. D. Reintsema
, et al. (13 additional authors not shown)
Abstract:
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f->3d transition and the parallel 4d->3p transition were observed with a full-width-at-half-maximum energy resolution of 6.8…
▽ More
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f->3d transition and the parallel 4d->3p transition were observed with a full-width-at-half-maximum energy resolution of 6.8 eV at 6.4 keV. Measured x-ray energies are consistent with calculated electromagnetic values which considered the strong-interaction effect assessed via the Seki-Masutani potential for the 3p energy level, and favor the electronic population of two filled 1s electrons in the K-shell. Absolute energy calibration with an uncertainty of 0.1 eV was demonstrated under a high-rate hadron beam condition of 1.45 MHz. This is the first application of a TES spectrometer to hadronic-atom x-ray spectroscopy and is an important milestone towards next-generation high-resolution kaonic-atom x-ray spectroscopy.
△ Less
Submitted 18 August, 2016;
originally announced August 2016.
-
Development of holmium-163 electron-capture spectroscopy with transition-edge sensors
Authors:
M. P. Croce,
M. W. Rabin,
V. Mocko,
G. J. Kunde,
E. R. Birnbaum,
E. M. Bond,
J. W. Engle,
A. S. Hoover,
F. M. Nortier,
A. D. Pollington,
W. A. Taylor,
N. R. Weisse-Bernstein,
L. E. Wolfsberg,
J. P. Hays-Wehle,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
T. E. Barnhart,
R. J. Nickles
Abstract:
Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (QEC < 3 keV) and short half-life (4570 y) of 163Ho make it attractive for high-precision electron capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum go…
▽ More
Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (QEC < 3 keV) and short half-life (4570 y) of 163Ho make it attractive for high-precision electron capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum goes to zero. In the ECS approach, an electron-capture-decaying isotope is embedded inside a microcalorimeter designed to capture and measure the energy of all the decay radiation except that of the escaping neutrino. We have developed a complete process for proton-irradiation-based isotope production, isolation, and purification of 163Ho. We have developed transition-edge sensors for this measurement and methods for incorporating 163Ho into high-resolution microcalorimeters, and have measured the electron-capture spectrum of 163Ho. We present our work in these areas and discuss the measured spectrum and its comparison to current theory.
△ Less
Submitted 20 October, 2015; v1 submitted 13 October, 2015;
originally announced October 2015.
-
High-resolution kaonic-atom x-ray spectroscopy with transition-edge-sensor microcalorimeters
Authors:
S. Okada,
D. A. Bennett,
W. B. Doriese,
J. W. Fowler,
K. D. Irwin,
S. Ishimoto,
M. Sato,
D. R. Schmidt,
D. S. Swetz,
H. Tatsuno,
J. N. Ullom,
S. Yamada
Abstract:
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resolutions of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction a…
▽ More
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resolutions of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction and provide new accurate charged-kaon mass value.
△ Less
Submitted 18 February, 2014; v1 submitted 30 January, 2014;
originally announced January 2014.