-
Development of MMC-based lithium molybdate cryogenic calorimeters for AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
H. Bae,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
S. Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev
, et al. (84 additional authors not shown)
Abstract:
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is und…
▽ More
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is under construction.This paper discusses the baseline design and characterization of the lithium molybdate cryogenic calorimeters to be used in the AMoRE-II detector modules. The results from prototype setups that incorporate new housing structures and two different crystal masses (316 g and 517 - 521 g), operated at 10 mK temperature, show energy resolutions (FWHM) of 7.55 - 8.82 keV at the 2.615 MeV $^{208}$Tl $γ$ line, and effective light detection of 0.79 - 0.96 keV/MeV. The simultaneous heat and light detection enables clear separation of alpha particles with a discrimination power of 12.37 - 19.50 at the energy region around $^6$Li(n, $α$)$^3$H with Q-value = 4.785 MeV. Promising detector performances were demonstrated at temperatures as high as 30 mK, which relaxes the temperature constraints for operating the large AMoRE-II array.
△ Less
Submitted 16 July, 2024;
originally announced July 2024.
-
Improved limit on neutrinoless double beta decay of \mohundred~from AMoRE-I
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (83 additional authors not shown)
Abstract:
AMoRE searches for the signature of neutrinoless double beta decay of $^{100}$Mo with a 100 kg sample of enriched $^{100}$Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. As a demonstration of the full-scale AMoRE, we conducted AMoRE-I, a pre-experiment with 18 molybdate c…
▽ More
AMoRE searches for the signature of neutrinoless double beta decay of $^{100}$Mo with a 100 kg sample of enriched $^{100}$Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. As a demonstration of the full-scale AMoRE, we conducted AMoRE-I, a pre-experiment with 18 molybdate crystals, at the Yangyang Underground Laboratory for over two years. The exposure was 8.02 kg$\cdot$year (or 3.89 kg$_{\mathrm{^{100}Mo}}\cdot$year) and the total background rate near the Q-value was 0.025 $\pm$ 0.002 counts/keV/kg/year. We observed no indication of $0νββ$ decay and report a new lower limit of the half-life of $^{100}$Mo $0νββ$ decay as $ T^{0ν}_{1/2}>3.0\times10^{24}~\mathrm{years}$ at 90\% confidence level. The effective Majorana mass limit range is $m_{ββ}<$(210--610) meV using nuclear matrix elements estimated in the framework of different models, including the recent shell model calculations.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Construction of Yemilab
Authors:
K. S. Park,
Y. D. Kim,
K. M. Bang,
H. K Park,
M. H. Lee,
J. H. Jang,
J. H. Kim,
J. So,
S. H. Kim,
S. B. Kim
Abstract:
The Center for Underground Physics of the Institute for Basic Science (IBS) in Korea has been planning the construction of a deep underground laboratory since 2013 to search for extremely rare interactions such as dark matter and neutrinos. In September 2022, a new underground laboratory, Yemilab, was finally completed in Jeongseon, Gangwon Province, with a depth of 1,000 m and an exclusive experi…
▽ More
The Center for Underground Physics of the Institute for Basic Science (IBS) in Korea has been planning the construction of a deep underground laboratory since 2013 to search for extremely rare interactions such as dark matter and neutrinos. In September 2022, a new underground laboratory, Yemilab, was finally completed in Jeongseon, Gangwon Province, with a depth of 1,000 m and an exclusive experimental area spanning 3,000 m$^3$. The tunnel is encased in limestone and accommodates 17 independent experimental spaces. Over two years, from 2023 to 2024, the Yangyang Underground Laboratory facilities will be relocated to Yemilab. Preparations are underway for the AMoRE-II, a neutrinoless double beta decay experiment, scheduled to begin in Q2 2024 at Yemilab. Additionally, Yemilab includes a cylindrical pit with a volume of approximately 6,300 m$^3$, designed as a multipurpose laboratory for next-generation experiments involving neutrinos, dark matter, and related research. This article provides a focused overview of the construction and structure of Yemilab.
△ Less
Submitted 21 February, 2024;
originally announced February 2024.
-
Background study of the AMoRE-pilot experiment
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (83 additional authors not shown)
Abstract:
We report a study on the background of the Advanced Molybdenum-Based Rare process Experiment (AMoRE), a search for neutrinoless double beta decay (\znbb) of $^{100}$Mo. The pilot stage of the experiment was conducted using $\sim$1.9 kg of \CAMOO~ crystals at the Yangyang Underground Laboratory, South Korea, from 2015 to 2018. We compared the measured $β/γ$ energy spectra in three experimental conf…
▽ More
We report a study on the background of the Advanced Molybdenum-Based Rare process Experiment (AMoRE), a search for neutrinoless double beta decay (\znbb) of $^{100}$Mo. The pilot stage of the experiment was conducted using $\sim$1.9 kg of \CAMOO~ crystals at the Yangyang Underground Laboratory, South Korea, from 2015 to 2018. We compared the measured $β/γ$ energy spectra in three experimental configurations with the results of Monte Carlo simulations and identified the background sources in each configuration. We replaced several detector components and enhanced the neutron shielding to lower the background level between configurations. A limit on the half-life of $0νββ$ decay of $^{100}$Mo was found at $T_{1/2}^{0ν} \ge 3.0\times 10^{23}$ years at 90\% confidence level, based on the measured background and its modeling. Further reduction of the background rate in the AMoRE-I and AMoRE-II are discussed.
△ Less
Submitted 7 April, 2024; v1 submitted 15 January, 2024;
originally announced January 2024.
-
Performance of an ultra-pure NaI(Tl) detector produced by an indigenously-developed purification method and crystal growth for the COSINE-200 experiment
Authors:
Hyun Seok Lee,
Byung Ju Park,
Jae Jin Choi,
Olga Gileva,
Chang Hyon Ha,
Alain Iltis,
Eun Ju Jeon,
Dae Yeon Kim,
Kyung Won Kim,
Sung Hyun Kim,
Sun Kee Kim,
Yeong Duk Kim,
Young Ju Ko,
Cheol Ho Lee,
Hyun Su Lee,
In Soo Lee,
Moo Hyun Lee,
Se Jin Ra,
Ju Kyung Son,
Keon Ah Shin
Abstract:
The COSINE-100 experiment has been operating with 106 kg of low-background NaI(Tl) detectors to test the results from the DAMA/LIBRA experiment, which claims to have observed dark matter. However, since the background of the NaI(Tl) crystals used in the COSINE-100 experiment is 2-3 times higher than that in the DAMA detectors, no conclusion regarding the claimed observation from the DAMA/LIBRA exp…
▽ More
The COSINE-100 experiment has been operating with 106 kg of low-background NaI(Tl) detectors to test the results from the DAMA/LIBRA experiment, which claims to have observed dark matter. However, since the background of the NaI(Tl) crystals used in the COSINE-100 experiment is 2-3 times higher than that in the DAMA detectors, no conclusion regarding the claimed observation from the DAMA/LIBRA experiment could be reached. Therefore, we plan to upgrade the current COSINE-100 experiment to the next phase, COSINE-200, by using ultra-low background NaI(Tl) detectors. The basic principle was already proved with the commercially available Astro-grade NaI powder from Sigma-Aldrich company. However, we have developed a mass production process of ultra-pure NaI powder at the Center for Underground Physics (CUP) of the Institute for Basic Science (IBS), Korea, using the direct purification of the raw NaI powder. We plan to produce more than 1,000 kg of ultra-pure powder for the COSINE200 experiment. With our crystal grower installed at CUP, we have successfully grown a low-background crystal using our purification technique for the NaI powder. We have assembled a low-background NaI(Tl) detector. In this article, we report the performance of this ultra-pure NaI(Tl) crystal detector produced at IBS, Korea.
△ Less
Submitted 12 January, 2023;
originally announced January 2023.
-
Direct dark matter searches with the full data set of XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
N. Kato,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
Y. Suzuki,
A. Takeda,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
Y. Itow,
K. Martens,
A. Mason,
M. Yamashita,
K. Miuchi,
Y. Takeuchi,
K. B. Lee,
M. K. Lee,
Y. Fukuda,
H. Ogawa
, et al. (7 additional authors not shown)
Abstract:
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was al…
▽ More
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was also available through a new low threshold trigger. Searching for a WIMP signal in the detector's 97~kg fiducial volume yielded a limit on the WIMP-nucleon scattering cross section of ${\rm 1.4\times 10^{-44}\, cm^{2}}$ for a ${\rm 60\,GeV/c^{2}}$ WIMP at the 90$\%$ confidence level. We also searched for WIMP induced annual modulation signatures in the detector's whole target volume, containing 832~kg of liquid xenon. For nuclear recoils of a ${\rm 8\,GeV/c^{2}}$ WIMP this analysis yielded a 90\% CL cross section limit of ${\rm 2.3\times 10^{-42}\, cm^{2}}$. At a WIMP mass of ${\rm 0.5\, GeV/c^{2}}$ the Migdal effect and Bremsstrahlung signatures were evaluated and lead to 90\% CL cross section limits of ${\rm 1.4\times 10^{-35}\, cm^{2}}$ and ${\rm 1.1\times 10^{-33}\, cm^{2}}$ respectively.
△ Less
Submitted 1 September, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Status and performance of the AMoRE-I experiment on neutrinoless double beta decay
Authors:
H. B. Kim,
D. H. Ha,
E. J. Jeon,
J. A. Jeon,
H. S. Jo,
C. S. Kang,
W. G. Kang,
H. S. Kim,
S. C. Kim,
S. G. Kim,
S. K. Kim,
S. R. Kim,
W. T. Kim,
Y. D. Kim,
Y. H. Kim,
D. H. Kwon,
E. S. Lee,
H. J. Lee,
H. S. Lee,
J. S. Lee,
M. H. Lee,
S. W. Lee,
Y. C. Lee,
D. S. Leonard,
H. S. Lim
, et al. (10 additional authors not shown)
Abstract:
AMoRE is an international project to search for the neutrinoless double beta decay of $^{100}$Mo using a detection technology consisting of magnetic microcalorimeters (MMCs) and molybdenum-based scintillating crystals. Data collection has begun for the current AMORE-I phase of the project, an upgrade from the previous pilot phase. AMoRE-I employs thirteen $^\mathrm{48depl.}$Ca$^{100}$MoO$_4$ cryst…
▽ More
AMoRE is an international project to search for the neutrinoless double beta decay of $^{100}$Mo using a detection technology consisting of magnetic microcalorimeters (MMCs) and molybdenum-based scintillating crystals. Data collection has begun for the current AMORE-I phase of the project, an upgrade from the previous pilot phase. AMoRE-I employs thirteen $^\mathrm{48depl.}$Ca$^{100}$MoO$_4$ crystals and five Li$_2$$^{100}$MoO$_4$ crystals for a total crystal mass of 6.2 kg. Each detector module contains a scintillating crystal with two MMC channels for heat and light detection. We report the present status of the experiment and the performance of the detector modules.
△ Less
Submitted 5 November, 2022;
originally announced November 2022.
-
An induced annual modulation signature in COSINE-100 data by DAMA/LIBRA's analysis method
Authors:
G. Adhikari,
N. Carlin,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
D. H. Lee
, et al. (32 additional authors not shown)
Abstract:
The DAMA/LIBRA collaboration has reported the observation of an annual modulation in the event rate that has been attributed to dark matter interactions over the last two decades. However, even though tremendous efforts to detect similar dark matter interactions were pursued, no definitive evidence has been observed to corroborate the DAMA/LIBRA signal. Many studies assuming various dark matter mo…
▽ More
The DAMA/LIBRA collaboration has reported the observation of an annual modulation in the event rate that has been attributed to dark matter interactions over the last two decades. However, even though tremendous efforts to detect similar dark matter interactions were pursued, no definitive evidence has been observed to corroborate the DAMA/LIBRA signal. Many studies assuming various dark matter models have attempted to reconcile DAMA/LIBRA's modulation signals and null results from other experiments, however no clear conclusion can be drawn. Apart from the dark matter hypothesis, several studies have examined the possibility that the modulation is induced by variations in their detector's environment or their specific analysis methods. In particular, a recent study presents a possible cause of the annual modulation from an analysis method adopted by the DAMA/LIBRA experiment in which the observed annual modulation could be reproduced by a slowly varying time-dependent background. Here, we study the COSINE-100 data using an analysis method similar to the one adopted by the DAMA/LIBRA experiment and observe a significant annual modulation, although the modulation phase is almost opposite to that of the DAMA/LIBRA data. Assuming the same background composition for COSINE-100 and DAMA/LIBRA, simulated experiments for the DAMA/LIBRA without dark matter signals also provide significant annual modulation with an amplitude similar to DAMA/LIBRA with opposite phase. Even though this observation does not explain the DAMA/LIBRA's results directly, this interesting phenomenon motivates deeper studies of the time-dependent DAMA/LIBRA background data.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.
-
Search for neutrinoless quadruple beta decay of $^{136}$Xe in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
N. Kato,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens
, et al. (12 additional authors not shown)
Abstract:
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was obser…
▽ More
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was observed from the energy spectrum fitting with precise background evaluation, and we set a lower limit of the half life of 3.7 $\times$ 10$^{24}$ years at 90$\%$ confidence level. This is the first experimental constraint of the neutrinoless quadruple beta decay of $^{136}$Xe.
△ Less
Submitted 5 August, 2022; v1 submitted 10 May, 2022;
originally announced May 2022.
-
Exploring coherent elastic neutrino-nucleus scattering using reactor electron antineutrinos in the NEON experiment
Authors:
J. J. Choi,
E. J. Jeon,
J. Y. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
Y. D. Kim,
Y. J. Ko,
B. C. Koh,
C. Ha,
B. J. Park,
S. H. Lee,
I. S. Lee,
H. Lee,
H. S. Lee,
J. Lee,
Y. M. Oh
Abstract:
Neutrino elastic scattering observation with NaI (NEON) is an experiment designed to detect neutrino-nucleus coherent scattering using reactor electron antineutrinos. NEON is based on an array of six NaI(Tl) crystals with a total mass of 13.3 kg, located at the tendon gallery that is 23.7 m away from a reactor core with a thermal power of 2.8 GW in the Hanbit nuclear power complex. The installatio…
▽ More
Neutrino elastic scattering observation with NaI (NEON) is an experiment designed to detect neutrino-nucleus coherent scattering using reactor electron antineutrinos. NEON is based on an array of six NaI(Tl) crystals with a total mass of 13.3 kg, located at the tendon gallery that is 23.7 m away from a reactor core with a thermal power of 2.8 GW in the Hanbit nuclear power complex. The installation of the NEON detector was completed in December 2020, and since May 2021, the detector has acquired data at full reactor power. Based on the observed light yields of the NaI crystals of approximately 22, number of photoelectrons per unit keV electron-equivalent energy (keVee), and 6 counts/kg/keV/day background level at 2-6 keVee energy, coherent elastic neutrino-nucleus scattering observation sensitivity is evaluated as more than 3$σ$ assuming one-year reactor-on and 100 days reactor-off data, 0.2 keVee energy threshold, and 7 counts/keV/kg/day background in the signal region of 0.2-0.5 keVee. This paper describes the design of the NEON detector, including the shielding arrangement, configuration of NaI(Tl) crystals, and associated operating systems. The initial performance and associated sensitivity of the experiment are also presented.
△ Less
Submitted 20 December, 2022; v1 submitted 8 April, 2022;
originally announced April 2022.
-
A feasibility study of extruded plastic scintillator embedding WLS fiber for AMoRE-II muon veto
Authors:
J. W. Seo,
W. T. Kim,
Y. D. Kim,
H. Y. Lee,
J. Lee,
M. H. Lee,
P. B. Nyanda,
E. S. Yi
Abstract:
AMoRE-II is the second phase of the Advanced Molybdenum-based Rare process Experiment aiming to search for the neutrino-less double beta decay of 100Mo isotopes using ~ 200 kg of molybdenum-containing cryogenic detectors. The AMoRE-II needs to keep the background level below 10-5 counts/keV/kg/year with various methods to maximize the sensitivity. One of the methods is to have the experiment be ca…
▽ More
AMoRE-II is the second phase of the Advanced Molybdenum-based Rare process Experiment aiming to search for the neutrino-less double beta decay of 100Mo isotopes using ~ 200 kg of molybdenum-containing cryogenic detectors. The AMoRE-II needs to keep the background level below 10-5 counts/keV/kg/year with various methods to maximize the sensitivity. One of the methods is to have the experiment be carried out deep underground free from the cosmic ray backgrounds. The AMoRE-II will run at Yemilab with ~ 1,000 m depth. However, even in such a deep underground environment, there are still survived cosmic muons, which can affect the measurement and should be excluded as much as possible. A muon veto detector is necessary to reject muon-induced particles coming to the inner detector where the molybdate cryogenic detectors are located. We have studied the possibility of using an extruded plastic scintillator and wavelength shifting fiber together with SiPM as a muon veto system. We found that the best configuration is two layers of plastic scintillators (PSs, 150 cm x 25 cm x 1.2 cm) with two WLS fibers per groove, which could separate radiogenic gammas well with muon detection efficiency above 99.4% along the length of the PS. Based on the expected flux from a prototype measurement at a 700 m deep underground, we found that the dead time of the muon veto system for AMoRE-II at the Yemilab with a 1 ms veto window is 0.6% of whole muon events.
△ Less
Submitted 11 July, 2022; v1 submitted 20 January, 2022;
originally announced January 2022.
-
Identification of new isomers in $^{228}$Ac : Impact on dark matter searches
Authors:
K. W. Kim,
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
J. J. Choi,
S. Choi,
M. Djamal,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
S. H. Kim,
S. K. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
E. K. Lee
, et al. (28 additional authors not shown)
Abstract:
We report the identification of metastable isomeric states of $^{228}$Ac at 6.28 keV, 6.67 keV and 20.19 keV, with lifetimes of an order of 100 ns. These states are produced by the $β$-decay of $^{228}$Ra, a component of the $^{232}$Th decay chain, with $β$ Q-values of 39.52 keV, 39.13 keV and 25.61 keV, respectively. Due to its low Q-value as well as the relative abundance of $^{232}$Th and their…
▽ More
We report the identification of metastable isomeric states of $^{228}$Ac at 6.28 keV, 6.67 keV and 20.19 keV, with lifetimes of an order of 100 ns. These states are produced by the $β$-decay of $^{228}$Ra, a component of the $^{232}$Th decay chain, with $β$ Q-values of 39.52 keV, 39.13 keV and 25.61 keV, respectively. Due to its low Q-value as well as the relative abundance of $^{232}$Th and their progeny in low background experiments, these observations potentially impact the low-energy background modeling of dark matter search experiments.
△ Less
Submitted 12 August, 2021; v1 submitted 3 March, 2021;
originally announced March 2021.
-
Search for sterile neutrino oscillation using RENO and NEOS data
Authors:
Z. Atif,
J. H. Choi,
B. Y. Han,
C. H. Jang,
H. I. Jang,
J. S. Jang,
E. J. Jeon,
S. H. Jeon,
K. K. Joo,
K. Ju,
D. E. Jung,
H. J. Kim,
H. S. Kim,
J. G. Kim,
J. H. Kim,
B. R. Kim,
J. Y. Kim,
J. Y. Kim,
S. B. Kim,
S. Y. Kim,
W. Kim,
Y. D. Kim,
Y. J. Ko,
E. Kwon,
D. H. Lee
, et al. (22 additional authors not shown)
Abstract:
We present a reactor model independent search for sterile neutrino oscillation using 2\,509\,days of RENO near detector data and 180 days of NEOS data. The reactor related systematic uncertainties are significantly suppressed as both detectors are located at the same reactor complex of Hanbit Nuclear Power Plant. The search is performed by electron antineutrino\,($\overlineν_e$) disappearance betw…
▽ More
We present a reactor model independent search for sterile neutrino oscillation using 2\,509\,days of RENO near detector data and 180 days of NEOS data. The reactor related systematic uncertainties are significantly suppressed as both detectors are located at the same reactor complex of Hanbit Nuclear Power Plant. The search is performed by electron antineutrino\,($\overlineν_e$) disappearance between six reactors and two detectors with baselines of 294\,m\,(RENO) and 24\,m\,(NEOS). A spectral comparison of the NEOS prompt-energy spectrum with a no-oscillation prediction from the RENO measurement can explore reactor $\overlineν_e$ oscillations to sterile neutrino. Based on the comparison, we obtain a 95\% C.L. excluded region of $0.1<|Δm_{41}^2|<7$\,eV$^2$. We also obtain a 68\% C.L. allowed region with the best fit of $|Δm_{41}^2|=2.41\,\pm\,0.03\,$\,eV$^2$ and $\sin^2 2θ_{14}$=0.08$\,\pm\,$0.03 with a p-value of 8.2\%. Comparisons of obtained reactor antineutrino spectra at reactor sources are made among RENO, NEOS, and Daya Bay to find a possible spectral variation.
△ Less
Submitted 6 September, 2022; v1 submitted 2 November, 2020;
originally announced November 2020.
-
Measurement of the Background Activities of a 100Mo-enriched Powder Sample for an AMoRE Crystal Material by using Fourteen High-Purity Germanium Detectors
Authors:
S. Y. Park,
K. I. Hahn,
W. G. Kang,
V. Kazalov,
G. W. Kim,
Y. D. Kim,
E. K. Lee,
M. H. Lee,
D. S. Leonard
Abstract:
The Advanced Molybdenum-based Rare process Experiment in its second phase (AMoRE-II) will search for neutrinoless double-beta (0ν\b{eta}\b{eta}) decay of 100Mo in 200 kg of molybdate crystals. To achieve the zero-background level in the energy range of the double-beta decay Q-value of 100Mo, the radioactive contamination levels in AMoRE crystals should be low. 100EnrMoO3 powder, which is enriched…
▽ More
The Advanced Molybdenum-based Rare process Experiment in its second phase (AMoRE-II) will search for neutrinoless double-beta (0ν\b{eta}\b{eta}) decay of 100Mo in 200 kg of molybdate crystals. To achieve the zero-background level in the energy range of the double-beta decay Q-value of 100Mo, the radioactive contamination levels in AMoRE crystals should be low. 100EnrMoO3 powder, which is enriched in the 100Mo isotope, is used to grow the AMoRE crystals. A shielded array of fourteen high-purity germanium detectors with 70% relative efficiency each was used for the measurement of background activities in a sample of 9.6-kg powder. The detector system named CAGe located at the Yangyang underground laboratory was designed for measuring low levels of radioactivity from natural radioisotopes or cosmogenic nuclides such as 228Ac, 228Th, 226Ra, 88Y, and 40K. The activities of 228Ac and 228Th in the powder sample were 0.88 \pm 0.12 mBq/kg and 0.669 \pm 0.087 mBq/kg, respectively. The activity of 226Ra was measured to be 1.50 \pm 0.23 mBq/kg. The activity of 88Y was 0.101 \pm 0.016 mBq/kg. The activity of 40K was found as 36.0 \pm 4.1 mBq/kg.
△ Less
Submitted 4 September, 2020;
originally announced September 2020.
-
Development of an array of HPGe detectors with 980% relative efficiency
Authors:
D. S. Leonard,
I. S. Hahn,
W. G. Kang,
V. Kazalov,
G. W. Kim,
Y. D. Kim,
E. K. Lee,
M. H. Lee,
S. Y. Park,
E. Sala
Abstract:
Searches for new physics push experiments to look for increasingly rare interactions. As a result, detectors require increasing sensitivity and specificity, and materials must be screened for naturally occurring, background-producing radioactivity. Furthermore the detectors used for screening must approach the sensitivities of the physics-search detectors themselves, thus motivating iterative deve…
▽ More
Searches for new physics push experiments to look for increasingly rare interactions. As a result, detectors require increasing sensitivity and specificity, and materials must be screened for naturally occurring, background-producing radioactivity. Furthermore the detectors used for screening must approach the sensitivities of the physics-search detectors themselves, thus motivating iterative development of detectors capable of both physics searches and background screening. We report on the design, installation, and performance of a novel, low-background, fourteen-element high-purity germanium detector named the CAGe (CUP Array of Germanium), installed at the Yangyang underground laboratory in Korea.
△ Less
Submitted 1 September, 2020;
originally announced September 2020.
-
Search for event bursts in XMASS-I associated with gravitational-wave events
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any pa…
▽ More
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any particular burst models, we looked for event bursts in sliding windows with various time width from 0.02 to 10 s. The search was conducted in a time window between $-$400 and $+$10,000 s from each gravitational-wave event. For the binary neutron star merger GW170817, no significant event burst was observed in the XMASS-I detector and we set 90% confidence level upper limits on neutrino fluence for the sum of all the neutrino flavors via coherent elastic neutrino-nucleus scattering. The obtained upper limit was (1.3-2.1)$\times 10^{11}$ cm$^{-2}$ under the assumption of a Fermi-Dirac spectrum with average neutrino energy of 20 MeV. The neutrino fluence limits for mono-energetic neutrinos in the energy range between 14 and 100 MeV were also calculated. Among the other 10 gravitational wave events detected as the binary black hole mergers, a burst candidate with a 3.0$σ$ significance was found at 1801.95-1803.95 s in the analysis for GW151012. However, no significant deviation from the background in the reconstructed energy and position distributions was found. Considering the additional look-elsewhere effect of analyzing the 11 GW events, the significance of finding such a burst candidate associated with any of them is 2.1$σ$.
△ Less
Submitted 30 December, 2020; v1 submitted 29 July, 2020;
originally announced July 2020.
-
Measurement of the Background Activities of a 100Mo-enriched powder sample for AMoRE crystal material using a single high purity germanium detector
Authors:
Su-yeon Park,
Insik Hahn,
Woon Gu Kang,
Gowoon Kim,
Eun Kyung Lee,
Douglas S. Leonard,
Vladimir Kazalov,
Yeong Duk Kim,
Moo Hyun Lee,
Elena Sala
Abstract:
The Advanced Molybdenum-based Rare process Experiment (AMoRE) searches for neutrino-less double-beta (0ν\b{eta}\b{eta}) decay of 100Mo in enriched molybdate crystals. The AMoRE crystals must have low levels of radioactive contamination to achieve low background signals with energies near the Q-value of the 100Mo 0ν\b{eta}\b{eta} decay. To produce low-activity crystals, radioactive contaminants in…
▽ More
The Advanced Molybdenum-based Rare process Experiment (AMoRE) searches for neutrino-less double-beta (0ν\b{eta}\b{eta}) decay of 100Mo in enriched molybdate crystals. The AMoRE crystals must have low levels of radioactive contamination to achieve low background signals with energies near the Q-value of the 100Mo 0ν\b{eta}\b{eta} decay. To produce low-activity crystals, radioactive contaminants in the raw materials used to form the crystals must be controlled and quantified. 100EnrMoO3 powder, which is enriched in the 100Mo isotope, is of particular interest as it is the source of 100Mo in the crystals. A high-purity germanium detector having 100% relative efficiency, named CC1, is being operated in the Yangyang underground laboratory. Using CC1, we collected a gamma spectrum from a 1.6-kg 100EnrMoO3 powder sample enriched to 96.4% in 100Mo. Activities were analyzed for the isotopes 228Ac, 228Th, 226Ra, and 40K. They are long-lived naturally occurring isotopes that can produce background signals in the region of interest for AMoRE. Activities of both 228Ac and 228Th were < 1.0 mBq/kg at 90% confidence level (C.L.). The activity of 226Ra was measured to be 5.1 \pm 0.4 (stat) \pm 2.2 (syst) mBq/kg. The 40K activity was found as < 16.4 mBq/kg at 90% C.L.
△ Less
Submitted 11 August, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.
-
Growth and development of pure Li2MoO4 crystals for rare event experiment at CUP
Authors:
J. K. Son,
J. S. Choe,
O. Gileva,
I. S. Hahn,
W. G. Kang,
D. Y. Kim,
G. W. Kim,
H. J. Kim,
Y. D. Kim,
C. H. Lee,
E. K. Lee,
M. H. Lee,
D. S. Leonard,
H. K. Park,
S. Y. Park,
S. J. Ra,
K. A. Shin
Abstract:
The Center for Underground Physics (CUP) of the Institute for Basic Science (IBS) is searching for the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) of 100Mo in the molybdate crystals of the AMoRE experiment. The experiment requires pure scintillation crystals to minimize internal backgrounds that can affect the 0ν\b{eta}\b{eta} signal. For the last few years, we have been growing and studying…
▽ More
The Center for Underground Physics (CUP) of the Institute for Basic Science (IBS) is searching for the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) of 100Mo in the molybdate crystals of the AMoRE experiment. The experiment requires pure scintillation crystals to minimize internal backgrounds that can affect the 0ν\b{eta}\b{eta} signal. For the last few years, we have been growing and studying Li2MoO4 crystals in a clean-environment facility to minimize external contamination during the crystal growth. Before growing Li2100MoO4 crystal, we have studied Li2natMoO4 crystal growth by a conventional Czochralski (CZ) grower. We grew a few different kinds of Li2natMO4 crystals using different raw materials in a campaign to minimize impurities. We prepared the fused Al2O3 refractories for the growth of ingots. Purities of the grown crystals were measured with high purity germanium detectors and by inductively coupled plasma mass spectrometry. The results show that the Li2MoO4 crystal has purity levels suitable for rare-event experiments. In this study, we present the growth of Li2MoO4 crystals at CUP and their purities.
△ Less
Submitted 14 May, 2020;
originally announced May 2020.
-
Development of ultra-pure NaI(Tl) detectors for the COSINE-200 experiment
Authors:
B. J. Park,
J. J. Choe,
J. S. Choi,
O. Gileva,
C. Ha,
A. Iltis,
E. J. Jeon,
D. Y. Kim,
K. W. Kim,
S. K. Kim,
Y. D. Kim,
Y. J. Ko,
C. H. Lee,
H. S. Lee,
I. S. Lee,
M. H. Lee,
S. H. Lee,
S. J. Ra,
J. K. Son,
K. A. Shin
Abstract:
The annual modulation signal observed by the DAMA experiment is a long-standing question in the community of dark matter direct detection. This necessitates an independent verification of its existence using the same detection technique. The COSINE-100 experiment has been operating with 106~kg of low-background NaI(Tl) detectors providing interesting checks on the DAMA signal. However, due to high…
▽ More
The annual modulation signal observed by the DAMA experiment is a long-standing question in the community of dark matter direct detection. This necessitates an independent verification of its existence using the same detection technique. The COSINE-100 experiment has been operating with 106~kg of low-background NaI(Tl) detectors providing interesting checks on the DAMA signal. However, due to higher backgrounds in the NaI(Tl) crystals used in COSINE-100 relative to those used for DAMA, it was difficult to reach final conclusions. Since the start of COSINE-100 data taking in 2016, we also have initiated a program to develop ultra-pure NaI(Tl) crystals for COSINE-200, the next phase of the experiment. The program includes efforts of raw powder purification, ultra-pure NaI(Tl) crystal growth, and detector assembly techniques. After extensive research and development of NaI(Tl) crystal growth, we have successfully grown a few small-size (0.61$-$0.78 kg) thallium-doped crystals with high radio-purity. A high light yield has been achieved by improvements of our detector assembly technique. Here we report the ultra-pure NaI(Tl) detector developments at the Institute for Basic Science, Korea. The technique developed here will be applied to the production of NaI(Tl) detectors for the COSINE-200 experiment.
△ Less
Submitted 31 August, 2020; v1 submitted 13 April, 2020;
originally announced April 2020.
-
A search for solar axion induced signals with COSINE-100
Authors:
P. Adhikari,
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
W. Kang,
M. Kauer,
G. S. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
V. A. Kudryavtsev
, et al. (23 additional authors not shown)
Abstract:
We present results from a search for solar axions with the COSINE-100 experiment. We find no evidence of solar axion events from a data-set of 6,303.9 kg$\cdot$days exposure and set a 90\,\% confidence level upper limit on the axion-electron coupling, $g_{ae}$, at 1.70~$\times$~$10^{-11}$ for an axion mass less than 1\,keV/c$^2$. This limit excludes QCD axions heavier than 0.59\,eV/c$^2$ in the DF…
▽ More
We present results from a search for solar axions with the COSINE-100 experiment. We find no evidence of solar axion events from a data-set of 6,303.9 kg$\cdot$days exposure and set a 90\,\% confidence level upper limit on the axion-electron coupling, $g_{ae}$, at 1.70~$\times$~$10^{-11}$ for an axion mass less than 1\,keV/c$^2$. This limit excludes QCD axions heavier than 0.59\,eV/c$^2$ in the DFSZ model and 168.1\,eV/c$^2$ in the KSVZ model.
△ Less
Submitted 10 July, 2019; v1 submitted 15 April, 2019;
originally announced April 2019.
-
The First Direct Search for Inelastic Boosted Dark Matter with COSINE-100
Authors:
C. Ha,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
M. Djamal,
A. C. Ezeribe,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
W. Kang,
M. Kauer,
G. S. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
V. A. Kudryavtsev
, et al. (23 additional authors not shown)
Abstract:
A search for inelastic boosted dark matter (iBDM) using the COSINE-100 detector with 59.5 days of data is presented. This relativistic dark matter is theorized to interact with the target material through inelastic scattering with electrons, creating a heavier state that subsequently produces standard model particles, such as an electron-positron pair. In this study, we search for this electron-po…
▽ More
A search for inelastic boosted dark matter (iBDM) using the COSINE-100 detector with 59.5 days of data is presented. This relativistic dark matter is theorized to interact with the target material through inelastic scattering with electrons, creating a heavier state that subsequently produces standard model particles, such as an electron-positron pair. In this study, we search for this electron-positron pair in coincidence with the initially scattered electron as a signature for an iBDM interaction. No excess over the predicted background event rate is observed. Therefore, we present limits on iBDM interactions under various hypotheses, one of which allows us to explore an area of the experimental search for iBDM using a terrestrial detector.
△ Less
Submitted 30 January, 2019; v1 submitted 22 November, 2018;
originally announced November 2018.
-
A measurement of the scintillation decay time constant of nuclear recoils in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) an…
▽ More
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) and a xenon nucleus. The inner detector volume contains 832 kg of LXe.
$^{252}$Cf was used as an external neutron source for irradiating the detector. The scintillation decay time constant of the resulting neutron induced NR was evaluated by comparing the observed photon detection times with Monte Carlo simulations. Fits to the decay time prefer two decay time components, one for each of the Xe$_{2}^{*}$ singlet and triplet states, with $τ_{S}$ = 4.3$\pm$0.6 ns taken from prior research, $τ_{T}$ was measured to be 26.9$^{+0.7}_{-1.1}$ ns with a singlet state fraction F$_{S}$ of 0.252$^{+0.027}_{-0.019}$.We also evaluated the performance of pulse shape discrimination between NR and electron recoil (ER) with the aim of reducing the electromagnetic background in WIMP searches. For a 50\% NR acceptance, the ER acceptance was 13.7${\pm}$1.0\% and 4.1${\pm}$0.7\% in the energy ranges of 5--10 keV$_{\rm ee}$ and 10--15 keV$_{\rm ee}$, respectively.
△ Less
Submitted 24 December, 2018; v1 submitted 16 September, 2018;
originally announced September 2018.
-
Search for WIMP-$^{129}$Xe inelastic scattering with particle identification in XMASS-I
Authors:
XMASS Collaboration,
T. Suzuki,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classific…
▽ More
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classification based on scintillation timing that distinguished $γ$-rays and $β$-rays, and simultaneous fitting of the energy spectra of $γ$-like and $β$-like samples. No evidence of a WIMP signal was found. Thus, we set the upper limits of the inelastic channel cross section at 90\% confidence level, for example, $4.1\times 10^{-39} \;{\rm cm^2}$ for a $200\; {\rm GeV}/c^2$ WIMP. This result provides the most stringent limits on the SD WIMP-neutron interaction and is better by a factor of 7.7 at $200\;{\rm GeV}/c^2$ than the existing experimental limit.
△ Less
Submitted 19 March, 2019; v1 submitted 14 September, 2018;
originally announced September 2018.
-
Search for sub-GeV dark matter by annual modulation using XMASS-I detector
Authors:
M. Kobayashi,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu,
K. Miuchi
, et al. (11 additional authors not shown)
Abstract:
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in…
▽ More
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
△ Less
Submitted 22 December, 2018; v1 submitted 19 August, 2018;
originally announced August 2018.
-
Direct dark matter search by annual modulation with 2.7 years of XMASS-I data
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more…
▽ More
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more than one year of additional data, which more than doubles the exposure to 800 live days with the same 832 kg target mass. When we assume weakly interacting massive particle (WIMP) dark matter elastically scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ at 90\% confidence level with our newly implemented data selection through a likelihood method. For the model-independent case, without assuming any specific dark matter model, we obtained more consistency with the null hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy region. This search probed this region with an exposure that was larger than that of DAMA/LIBRA. We also did not find any significant amplitude in the data for periodicity with periods between 50 and 600 days in the energy region between 1 to 6 keV.
△ Less
Submitted 25 May, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Measurement of low-energy background events due to $^{222}$Rn contamination on the surface of a NaI(Tl) crystal
Authors:
K. W. Kim,
C. Ha,
N. Y. Kim,
Y. D. Kim,
H. S. Lee,
B. J. Park,
H. K. Park
Abstract:
It has been known that decays of daughter elements of $^{222}$Rn on the surface of a detector cause significant background at energies below 10 keV. In particular $^{210}$Pb and $^{210}$Po decays on the crystal surface result in significant background for dark matter search experiments with NaI(Tl) crystals. In this report, measurement of $^{210}$Pb and $^{210}$Po decays on surfaces are obtained b…
▽ More
It has been known that decays of daughter elements of $^{222}$Rn on the surface of a detector cause significant background at energies below 10 keV. In particular $^{210}$Pb and $^{210}$Po decays on the crystal surface result in significant background for dark matter search experiments with NaI(Tl) crystals. In this report, measurement of $^{210}$Pb and $^{210}$Po decays on surfaces are obtained by using a $^{222}$Rn contaminated crystal. Alpha decay events of $^{210}$Po on the surface are measured by coincidence requirements of two attached crystals. Due to recoiling of $^{206}$Pb, rapid nuclear recoil events are observed. A mean time characterization demonstrates that $^{206}$Pb recoil events can be statistically separated from those of sodium or iodine nuclear recoil events, as well as electron recoil events.
△ Less
Submitted 11 May, 2018; v1 submitted 21 January, 2018;
originally announced January 2018.
-
Improved search for two-neutrino double electron capture on $^{124}$Xe and $^{126}$Xe using particle identification in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant sig…
▽ More
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \times 10^{22}$ and $1.9 \times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.
△ Less
Submitted 16 April, 2018; v1 submitted 10 January, 2018;
originally announced January 2018.
-
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Authors:
XMASS Collaboration,
N. Oka,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda
, et al. (17 additional authors not shown)
Abstract:
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits arou…
▽ More
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $δ= 2$ that axions can propagate in.
△ Less
Submitted 15 November, 2017; v1 submitted 19 July, 2017;
originally announced July 2017.
-
Measurement of Fast Neutron Rate for NEOS Experiment
Authors:
Y. J. Ko,
J. Y. Kim,
B. Y. Han,
C. H. Jang,
E. J. Jeon,
K. K. Joo,
B. R. Kim,
H. J. Kim,
H. S. Kim,
Y. D. Kim,
Jaison Lee,
J. Y. Lee,
M. H. Lee,
Y. M. Oh,
H. K. Park,
H. S. Park,
K. S. Park,
K. M. Seo,
Kim Siyeon,
G. M. Sun
Abstract:
The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and off periods and found to be ~20 per day fo…
▽ More
The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and off periods and found to be ~20 per day for both periods. The fast neutron rate is also measured at an overground site with a negligible overburden and is found to be ~100 times higher than that at the NEOS experiment site.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
H. Takiya,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
R. Kegasa,
K. Kobayashi,
K. Masuda,
K. Fushimi
, et al. (15 additional authors not shown)
Abstract:
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xeno…
▽ More
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $τ_1$ and $τ_2$, the decay time constant $τ_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $τ_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $τ_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.
△ Less
Submitted 18 August, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
A CaMoO4 Crystal Low Temperature Detector for the AMoRE Neutrinoless Double Beta Decay Search
Authors:
G. B. Kim,
S. Choi,
F. A. Danevich,
A. Fleischmann,
C. S. Kang,
H. J. Kim,
S. R. Kim,
Y. D. Kim,
Y. H. Kim,
V. A. Kornoukhov,
H. J. Lee,
J. H. Lee,
M. K. Lee,
S. J. Lee,
J. H. So,
W. S. Yoon
Abstract:
We report the development of a CaMoO4 crystal low temperature detector for the AMoRE neutrinoless double beta decay (0ν\b{eta}\b{eta}) search experiment. The prototype detector cell was composed of a 216 g CaMoO4 crystal and a metallic magnetic calorimeter. An over-ground measurement demonstrated FWHM resolution of 6-11 keV for full absorption gamma peaks. Pulse shape discrimination was clearly de…
▽ More
We report the development of a CaMoO4 crystal low temperature detector for the AMoRE neutrinoless double beta decay (0ν\b{eta}\b{eta}) search experiment. The prototype detector cell was composed of a 216 g CaMoO4 crystal and a metallic magnetic calorimeter. An over-ground measurement demonstrated FWHM resolution of 6-11 keV for full absorption gamma peaks. Pulse shape discrimination was clearly demonstrated in the phonon signals, and 7.6 σ of discrimination power was found for the α and \b{eta}/γ separation. The phonon signals showed rise-times of about 1 ms. It is expected that the relatively fast rise-time will increase the rejection efficiency of two-neutrino double beta decay pile-up events which can be one of the major background sources in 0ν\b{eta}\b{eta} searches.
△ Less
Submitted 24 February, 2016;
originally announced February 2016.
-
Direct dark matter search by annual modulation in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
K. Fushimi,
J. Liu,
K. Martens,
Y. Suzuki,
B. D. Xu,
R. Fujita
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on t…
▽ More
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$γ$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.
△ Less
Submitted 25 May, 2016; v1 submitted 15 November, 2015;
originally announced November 2015.
-
Search for two-neutrino double electron capture on $^{124}$Xe with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
J. Liu,
K. Martens,
Y. Suzuki,
R. Fujita,
K. Hosokawa
, et al. (19 additional authors not shown)
Abstract:
Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on $^{124}$X…
▽ More
Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on $^{124}$Xe is performed using 165.9 days of data collected with the XMASS-I liquid xenon detector. No significant excess above background was observed and we set a lower limit on the half-life as $4.7 \times 10^{21}$ years at 90% confidence level. The obtained limit has ruled out parts of some theoretical expectations. We obtain a lower limit on the $^{126}$Xe two-neutrino double electron capture half-life of $4.3 \times 10^{21}$ years at 90% confidence level as well.
△ Less
Submitted 25 May, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
Search for bosonic superweakly interacting massive dark matter particles with the XMASS-I detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Ichimura,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi
, et al. (20 additional authors not shown)
Abstract:
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data…
▽ More
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data no significant excess above background was observed in the fiducial mass of 41 kg. The present limit for the vector super-WIMPs excludes the possibility that such particles constitute all of dark matter. The absence of a signal also provides the most stringent direct constraint on the coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented sensitivity was achieved exploiting the low background at a level $10^{-4}$ kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
△ Less
Submitted 21 August, 2014; v1 submitted 2 June, 2014;
originally announced June 2014.
-
First result of the experimental search for the 9.4 keV solar axion reactions with Kr-83 in the copper proportional counter
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. V. Derbin,
V. V. Kazalov,
H. J. Kim,
Y. D. Kim,
V. V. Kobychev,
V. V. Kuzminov,
Luqman Ali,
V. N. Muratova,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Semenov,
D. A. Tekueva,
S. P. Yakimenko,
E. V. Unzhakov
Abstract:
The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the…
▽ More
The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m_{A} < 130 eV at 95% C.L.
△ Less
Submitted 6 May, 2014;
originally announced May 2014.
-
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from the XMASS-I experiment
Authors:
H. Uchida,
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa
, et al. (21 additional authors not shown)
Abstract:
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to…
▽ More
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to derive our limits without explicitly subtracting the remaining events which are compatible with background expectations and derive for e.g. a 50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei of 3.2 pb at the 90% confidence level.
△ Less
Submitted 29 April, 2014; v1 submitted 19 January, 2014;
originally announced January 2014.
-
Search for solar axions in XMASS, a large liquid-xenon detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki Y. Suzuki,
A. Takeda,
O. Takachio,
K. Ueshima,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi,
A. Murata
, et al. (21 additional authors not shown)
Abstract:
XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$ (90% C.L.), which is a factor of two stronger than the existing experimental limit. The b…
▽ More
XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$ (90% C.L.), which is a factor of two stronger than the existing experimental limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are 1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced the most stringent limit, which is better than that previously derived from astrophysical arguments regarding the Sun to date.
△ Less
Submitted 29 May, 2013; v1 submitted 26 December, 2012;
originally announced December 2012.
-
Light WIMP search in XMASS
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki Y. Suzuki,
A. Takeda,
O. Takachio,
K. Ueshima,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi,
A. Murata
, et al. (21 additional authors not shown)
Abstract:
A search for light dark matter using low-threshold data from the single phase liquid xenon scintillation detector XMASS, has been conducted. Using the entire 835 kg inner volume as target, the analysis threshold can be lowered to 0.3 keVee (electron-equivalent) to search for light dark matter. With low-threshold data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and without discr…
▽ More
A search for light dark matter using low-threshold data from the single phase liquid xenon scintillation detector XMASS, has been conducted. Using the entire 835 kg inner volume as target, the analysis threshold can be lowered to 0.3 keVee (electron-equivalent) to search for light dark matter. With low-threshold data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and without discriminating between nuclear-recoil and electronic events, XMASS excludes part of the parameter space favored by other experiments.
△ Less
Submitted 16 January, 2013; v1 submitted 22 November, 2012;
originally announced November 2012.
-
Light Sterile Neutrinos: A White Paper
Authors:
K. N. Abazajian,
M. A. Acero,
S. K. Agarwalla,
A. A. Aguilar-Arevalo,
C. H. Albright,
S. Antusch,
C. A. Arguelles,
A. B. Balantekin,
G. Barenboim,
V. Barger,
P. Bernardini,
F. Bezrukov,
O. E. Bjaelde,
S. A. Bogacz,
N. S. Bowden,
A. Boyarsky,
A. Bravar,
D. Bravo Berguno,
S. J. Brice,
A. D. Bross,
B. Caccianiga,
F. Cavanna,
E. J. Chun,
B. T. Cleveland,
A. P. Collin
, et al. (162 additional authors not shown)
Abstract:
This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.
This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.
△ Less
Submitted 18 April, 2012;
originally announced April 2012.
-
Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon
Authors:
K. Ueshima,
K. Abe,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
Y. Koshio,
J. Liu,
K. Martens,
S. Moriyama,
M. Nakahata,
H. Nishiie,
H. Ogawa,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
M. Yamashita,
K. Fujii,
I. Murayama,
S. Nakamura,
K. Otsuka,
Y. Takeuchi,
Y. Fukuda,
K. Nishijima
, et al. (12 additional authors not shown)
Abstract:
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a singl…
▽ More
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2 0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to 7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee for a scintillation light yield of 20.9 p.e./keV. Further study was done by masking some of that light to reduce this yield to 4.6 p.e./keV, the same method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3 0.2(sys)\times10-1 for the lower of the energy regions above. We also observe that in contrast to nuclear recoils the fluctuations in our early to total ratio for electron events are larger than expected from statistical fluctuations.
△ Less
Submitted 11 June, 2011;
originally announced June 2011.
-
Development of CaMoO4 crystal scintillators for double beta decay experiment with 100-Mo
Authors:
A. N. Annenkov,
O. A. Buzanov,
F. A. Danevich,
A. Sh. Georgadze,
S. K. Kim,
H. J. Kim,
Y. D. Kim,
V. V. Kobychev,
V. N. Kornoukhov,
M. Korzhik,
J. I. Lee,
O. Missevitch,
V. M. Mokina,
S. S. Nagorny,
A. S. Nikolaiko,
D. V. Poda,
R. B. Podviyanuk,
D. J. Sedlak,
O. G. Shkulkova,
J. H. So,
I. M. Solsky,
V. I. Tretyak,
S. S. Yurchenko
Abstract:
Energy resolution, alpha/beta ratio, pulse-shape discrimination for gamma rays and alpha particles, temperature dependence of scintillation properties, and radioactive contamination were studied with CaMoO4 crystal scintillators. A high sensitivity experiment to search for neutrinoless double beta decay of 100-Mo by using CaMoO4 scintillators is discussed.
Energy resolution, alpha/beta ratio, pulse-shape discrimination for gamma rays and alpha particles, temperature dependence of scintillation properties, and radioactive contamination were studied with CaMoO4 crystal scintillators. A high sensitivity experiment to search for neutrinoless double beta decay of 100-Mo by using CaMoO4 scintillators is discussed.
△ Less
Submitted 10 July, 2007;
originally announced July 2007.
-
Measurement on the thermal neutron capture cross section of w-180
Authors:
W. G. Kang,
Y. D. Kim,
J. I. Lee,
I. S. Hahn,
A. R. Kim,
H. J. Kim
Abstract:
We have measured the thermal neutron capture cross section for w-180 nucleus. There is only one previous data on this cross section with a value of 30 $^{+300%}_{-100%}$ barn. To consider w-181 as a low energy neutrino source, the thermal neutron capture cross section should be measured more precisely to estimate the production rate of w-181 inside a nuclear reactor. We measured the cross sectio…
▽ More
We have measured the thermal neutron capture cross section for w-180 nucleus. There is only one previous data on this cross section with a value of 30 $^{+300%}_{-100%}$ barn. To consider w-181 as a low energy neutrino source, the thermal neutron capture cross section should be measured more precisely to estimate the production rate of w-181 inside a nuclear reactor. We measured the cross section of w-180 with a natural tungsten foil and obtained a new value of 21.9 $\pm$ 2.5 barn
△ Less
Submitted 23 April, 2007; v1 submitted 23 April, 2007;
originally announced April 2007.
-
Mesonic and nonmesonic weak decay widths of medium-heavy lambda hypernuclei
Authors:
Y. Sato,
S. Ajimura,
K. Aoki,
H. Bhang,
T. Hasegawa,
O. Hashimoto,
H. Hotchi,
Y. D. Kim,
T. Kishimoto,
K. Maeda,
H. Noumi,
Y. Ohta,
K. Omata,
H. Outa,
H. Park,
M. Sekimoto,
T. Shibata,
T. Takahashi,
M. Youn
Abstract:
We have measured the energy spectra of pions and protons emitted in the weak decay of 12_Lambda_C, 28_Lambda_Si, and Lambda_Fe hypernuclei produced via the (pi+, K+) reaction. The decay widths of the pi- mesonic decay (Lambda -> p + pi-) and the nonmesonic decay (Lambda + N -> N + N) were extracted. The present results demonstrate an increase of the mesonic decay width due to a distortion of the…
▽ More
We have measured the energy spectra of pions and protons emitted in the weak decay of 12_Lambda_C, 28_Lambda_Si, and Lambda_Fe hypernuclei produced via the (pi+, K+) reaction. The decay widths of the pi- mesonic decay (Lambda -> p + pi-) and the nonmesonic decay (Lambda + N -> N + N) were extracted. The present results demonstrate an increase of the mesonic decay width due to a distortion of the pion wave function in nuclear medium for the first time. The ratios of the neutron- to proton-induced nonmesonic decay widths, Gamma_n(Lambda + n -> n + n)/Gamma_p(Lambda + p -> n + p), were evaluated by a direct comparison of the measured proton energy spectra with the calculated ones. No theoretical calculation which has been proposed so far can simultaneously account for both the nonmesonic decay widths and the Gamma_n/Gamma_p ratios in the present data.
△ Less
Submitted 14 March, 2005; v1 submitted 11 September, 2004;
originally announced September 2004.
-
Neutron beam test of CsI crystal for dark matter search
Authors:
H. Park,
D. H. Choi,
I. S. Hahn,
M. J. Hwang,
W. G. Kang,
H. J. Kim,
J. H. Kim,
S. C. Kim,
S. K. Kim,
T. Y. Kim,
Y. D. Kim,
Y. J. Kwon,
H. S. Lee,
J. H. Lee,
M. H. Lee,
S. E. Lee,
S. H. Noh,
I. H. Park,
E. S. Seo,
E. Won,
H. Y. Yang,
M. S. Yang,
I. Yu
Abstract:
We have studied the response of Tl-doped and Na-doped CsI crystals to nuclear recoils and $γ$'s below 10 keV. The response of CsI crystals to nuclear recoil was studied with mono-energetic neutrons produced by the $^3$H(p,n)$^3$He reaction. This was compared to the response to Compton electrons scattered by 662 keV $γ$-ray. Pulse shape discrimination between the response to these $γ$'s and nucle…
▽ More
We have studied the response of Tl-doped and Na-doped CsI crystals to nuclear recoils and $γ$'s below 10 keV. The response of CsI crystals to nuclear recoil was studied with mono-energetic neutrons produced by the $^3$H(p,n)$^3$He reaction. This was compared to the response to Compton electrons scattered by 662 keV $γ$-ray. Pulse shape discrimination between the response to these $γ$'s and nuclear recoils was studied, and quality factors were estimated. The quenching factors for nuclear recoils were derived for both CsI(Na) and CsI(Tl) crystals.
△ Less
Submitted 13 February, 2002;
originally announced February 2002.
-
A statistical interpretation of the correlation between intermediate mass fragment multiplicity and transverse energy
Authors:
L. Phair,
L. Beaulieu,
L. G. Moretto,
G. J. Wozniak,
D. R. Bowman,
N. Carlin,
L. Celano,
N. Colonna,
J. D. Dinius,
A. Ferrero,
C. K. Gelbke,
T. Glasmacher,
F. Gramegna,
D. O. Handzy,
W. C. Hsi,
M. J. Huang,
I. Iori,
Y. D. Kim,
M. A. Lisa,
W. G. Lynch,
G. V. Margagliotti,
P. F. Mastinu,
P. M. Milazzo,
C. P. Montoya,
A. Moroni
, et al. (7 additional authors not shown)
Abstract:
Multifragment emission following Xe+Au collisions at 30, 40, 50 and 60 AMeV has been studied with multidetector systems covering nearly 4-pi in solid angle. The correlations of both the intermediate mass fragment and light charged particle multiplicities with the transverse energy are explored. A comparison is made with results from a similar system, Xe+Bi at 28 AMeV. The experimental trends are…
▽ More
Multifragment emission following Xe+Au collisions at 30, 40, 50 and 60 AMeV has been studied with multidetector systems covering nearly 4-pi in solid angle. The correlations of both the intermediate mass fragment and light charged particle multiplicities with the transverse energy are explored. A comparison is made with results from a similar system, Xe+Bi at 28 AMeV. The experimental trends are compared to statistical model predictions.
△ Less
Submitted 9 September, 1999;
originally announced September 1999.
-
Charge correlations and dynamical instabilities in the multifragment emission process
Authors:
L. G. Moretto,
Th. Rubehn,
L. Phair,
N. Colonna,
G. J. Wozniak,
D. R. Bowman,
G. F. Peaslee,
N. Carlin,
R. T. de Souza,
C. K. Gelbke,
W. G. Gong,
Y. D. Kim,
M. A. Lisa,
W. G. Lynch,
C. Williams
Abstract:
A new, sensitive method allows one to search for the enhancement of events with nearly equal-sized fragments as predicted by theoretical calculations based on volume or surface instabilities. Simulations have been performed to investigate the sensitivity of the procedure. Experimentally, charge correlations of intermediate mass fragments emitted from heavy ion reactions at intermediate energies…
▽ More
A new, sensitive method allows one to search for the enhancement of events with nearly equal-sized fragments as predicted by theoretical calculations based on volume or surface instabilities. Simulations have been performed to investigate the sensitivity of the procedure. Experimentally, charge correlations of intermediate mass fragments emitted from heavy ion reactions at intermediate energies have been studied. No evidence for a preferred breakup into equal-sized fragments has been found.
△ Less
Submitted 9 July, 1996;
originally announced July 1996.