Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer
Authors:
David J. Mercer,
Ryan Winkler,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Krystal I. de Castro,
Eric A. Feissle,
Joseph W. Fowler,
Johnathon D. Gard,
John A. B. Mates,
Daniel G. McNeel,
Nathan J. Ortiz,
Daniel Schmidt,
Katherine A. Schreiber,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Sophie L. Weidenbenner,
Abigail L. Wessels
Abstract:
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter…
▽ More
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter gamma-ray spectrometer. For the 103-keV gamma ray we report an improved centroid energy and emission probability.
△ Less
Submitted 8 July, 2022; v1 submitted 6 February, 2022;
originally announced February 2022.
-
Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers
Authors:
Mark Croce,
Daniel Becker,
Katrina E. Koehler,
Joel Ullom
Abstract:
Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma…
▽ More
Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and HPGe data, allowing direct comparison. We present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
New Experimentally Observable Gamma-ray Emissions from 241Am Nuclear Decay
Authors:
Katrina E. Koehler,
Michael D. Yoho,
Matthew H. Carpenter,
Mark P. Croce,
David J. Mercer,
Chandler M. Smith,
Aidan D. Tollefson,
Duc T. Vo,
Michael A. Famiano,
Daniel T. Becker,
Johnathon D. Gard,
J. A. B. Mates,
Nathan J. Ortiz,
Joel N. Ullom,
Abigail L. Wessels,
Douglas A. Bennett,
Daniel R. Schmidt,
Daniel S. Swetz,
Leila R. Vale
Abstract:
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of 241Am decay with a large microcalorimeter array has yielded never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These have been made possible because of new microwave-multiplexing readout and improved analysis al…
▽ More
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of 241Am decay with a large microcalorimeter array has yielded never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These have been made possible because of new microwave-multiplexing readout and improved analysis algorithms for microcalorimeters.
△ Less
Submitted 29 March, 2021;
originally announced March 2021.
-
Improved Plutonium and Americium Photon Branching Ratios from Microcalorimeter Gamma Spectroscopy
Authors:
Michael D. Yoho,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Johnathon D. Gard,
J. A. Ben Mates,
David J. Mercer,
Nathan J. Ortiz,
Daniel R. Schmidt,
Chandler M. Smith,
Daniel S. Swetz,
Aidan D. Tollefson,
Joel N. Ullom,
Leila R. Vale,
Abigail L. Wessels,
Duc T. Vo
Abstract:
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-h…
▽ More
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium (238Pu,239Pu,241Pu) and 241Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. We show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2{3 for four branching ratios.
△ Less
Submitted 22 June, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.
-
Study of Two-Photon Exchange via the Beam Transverse Single Spin Asymmetry in Electron-Proton Elastic Scattering at Forward Angles over a Wide Energy Range
Authors:
B. Gou,
J. Arvieux,
K. Aulenbacher,
D. Balaguer Ríos,
S. Baunack,
D. Becker,
L. Capozza,
W. Deconinck,
J. Diefenbach,
R. Frascaria,
M. Gorchtein,
B. Gläser,
D. von Harrach,
Y. Imai,
E. M. Kabuß,
R. Kothe,
S. Kowalski,
R. Kunne,
F. E. Maas,
H. Merkel,
M. C. Mora Espí,
M. Morlet,
U. Müller,
S. Ong,
E. Schilling
, et al. (4 additional authors not shown)
Abstract:
We report on a new measurement of the beam transverse single spin asymmetry in electron-proton elastic scattering, $A^{ep}_{\perp}$, at five beam energies from 315.1 MeV to 1508.4 MeV and at a scattering angle of $30^{\circ} < θ< 40^{\circ}$. The covered $Q^2$ values are 0.032, 0.057, 0.082, 0.218, 0.613 (GeV/c)$^2$. The measurement clearly indicates significant inelastic contributions to the two-…
▽ More
We report on a new measurement of the beam transverse single spin asymmetry in electron-proton elastic scattering, $A^{ep}_{\perp}$, at five beam energies from 315.1 MeV to 1508.4 MeV and at a scattering angle of $30^{\circ} < θ< 40^{\circ}$. The covered $Q^2$ values are 0.032, 0.057, 0.082, 0.218, 0.613 (GeV/c)$^2$. The measurement clearly indicates significant inelastic contributions to the two-photon-exchange (TPE) amplitude in the low-$Q^2$ kinematic region. No theoretical calculation is able to reproduce our result. Comparison with a calculation based on unitarity, which only takes into account elastic and $\mathrm{πN}$ inelastic intermediate states, suggests that there are other inelastic intermediate states such as $\mathrm{ππN}$, $\mathrm{K Λ}$ and $\mathrm{ηN}$. Covering a wide energy range, our new high-precision data provide a benchmark to study those intermediate states.
△ Less
Submitted 14 February, 2020;
originally announced February 2020.
-
The P2 Experiment - A future high-precision measurement of the electroweak mixing angle at low momentum transfer
Authors:
Dominik Becker,
Razvan Bucoveanu,
Carsten Grzesik,
Ruth Kempf,
Kathrin Imai,
Matthias Molitor,
Alexey Tyukin,
Marco Zimmermann,
David Armstrong,
Kurt Aulenbacher,
Sebastian Baunack,
Rakitha Beminiwattha,
Niklaus Berger,
Peter Bernhard,
Andrea Brogna,
Luigi Capozza,
Silviu Covrig Dusa,
Wouter Deconinck,
Jürgen Diefenbach,
Jens Erler,
Ciprian Gal,
Boris Gläser,
Boxing Gou,
Wolfgang Gradl,
Michael Gericke
, et al. (20 additional authors not shown)
Abstract:
This article describes the future P2 parity-violating electron scattering facility at the upcoming MESA accelerator in Mainz. The physics program of the facility comprises indirect, high precision search for physics beyond the Standard Model, measurement of the neutron distribution in nuclear physics, single-spin asymmetries stemming from two-photon exchange and a possible future extension to the…
▽ More
This article describes the future P2 parity-violating electron scattering facility at the upcoming MESA accelerator in Mainz. The physics program of the facility comprises indirect, high precision search for physics beyond the Standard Model, measurement of the neutron distribution in nuclear physics, single-spin asymmetries stemming from two-photon exchange and a possible future extension to the measurement of hadronic parity violation. The first measurement of the P2 experiment aims for a high precision determination of the weak mixing angle to a precision of 0.14% at a four-momentum transfer of Q^2 = 4.5 10^{-3} GeV^2. The accuracy is comparable to existing measurements at the Z pole. It comprises a sensitive test of the standard model up to a mass scale of 50 TeV, extendable to 70 TeV. This requires a measurement of the parity violating cross section asymmetry -39.94 10^{-9} in the elastic electron-proton scattering with a total accuracy of 0.56 10^-9 (1.4 %) in 10,000 h of 150 \micro A polarized electron beam impinging on a 60 cm liquid H_2 target allowing for an extraction of the weak charge of the proton which is directly connected to the weak mixing angle. Contributions from gamma Z-box graphs become small at the small beam energy of 155 MeV. The size of the asymmetry is the smallest asymmetry ever measured in electron scattering with an unprecedented goal for the accuracy. We report here on the conceptual design of the P2 spectrometer, its Cherenkov detectors, the integrating read-out electronics as well as the ultra-thin, fast tracking detectors. There has been substantial theory work done in preparation of the determination of the weak mixing angle. The further physics program in particle and nuclear physics is described as well.
△ Less
Submitted 14 March, 2018; v1 submitted 13 February, 2018;
originally announced February 2018.
-
Study of Light Backgrounds from Relativistic Electrons in Air Light-Guides
Authors:
S. Riordan,
Y. X. Zhao,
S. Baunack,
D. Becker,
C. Clarke,
K. Dehmelt,
A. Deshpande,
M. Gericke,
B. Glaser,
K. Imai,
T. Kutz,
F. E. Maas,
D. McNulty,
J. Pan,
S. Park,
S. Rahman,
P. A. Souder,
P. Wang,
B. Wellman,
K. S. Kumar
Abstract:
The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Møller scattering). A relative measure of the scattering rate is planned to…
▽ More
The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Møller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the Møller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.
△ Less
Submitted 23 April, 2018; v1 submitted 19 October, 2017;
originally announced October 2017.
-
Measuring the weak mixing angle with the P2 experiment at MESA
Authors:
Niklaus Berger,
Kurt Aulenbacher,
Sebastian Baunack,
Dominik Becker,
Jürgen Diefenbach,
Michael Gericke,
Kathrin Gerz,
Ruth Herbertz,
Krishna Kumar,
Frank Maas,
Matthias Molitor,
David Rodríguez Piñeiro,
Iurii Sorokin,
Paul Souder,
Hubert Spiesberger,
Alexey Tyukin,
Valery Tyukin,
Marco Zimmermann
Abstract:
The P2 experiment in Mainz aims to measure the weak mixing angle in electron- proton scattering to a precision of 0.13 %. In order to suppress uncertainties due to proton structure and contributions from box graphs, both a low average momentum transfer $Q^2$ of $4.5\cdot 10^{-3}$ GeV$^2/c^2$ and a low beam energy of 155 MeV are chosen. In order to collect the enormous statistics required for this…
▽ More
The P2 experiment in Mainz aims to measure the weak mixing angle in electron- proton scattering to a precision of 0.13 %. In order to suppress uncertainties due to proton structure and contributions from box graphs, both a low average momentum transfer $Q^2$ of $4.5\cdot 10^{-3}$ GeV$^2/c^2$ and a low beam energy of 155 MeV are chosen. In order to collect the enormous statistics required for this measurement, the new Mainz Energy Recovery Superconducting Accelerator (MESA) is being constructed. These proceedings describe the motivation for the measurement, the experimental and accelerator challenges and how we plan to tackle them.
△ Less
Submitted 12 November, 2015;
originally announced November 2015.