-
Status of ArDM-1t: First observations from operation with a full ton-scale liquid argon target
Authors:
ArDM Collaboration,
J. Calvo,
C. Cantini,
M. Daniel,
U. Degunda,
S. Di Luise,
L. Epprecht,
A. Gendotti,
S. Horikawa,
L. Knecht,
B. Montes,
W. Mu,
M. Munoz,
S. Murphy,
G. Natterer,
K. Nguyen,
K. Nikolics,
L. Periale,
C. Regenfus,
L. Romero,
A. Rubbia,
R. Santorelli,
F. Sergiampietri,
D. Sgalaberna,
T. Viant
, et al. (1 additional authors not shown)
Abstract:
ArDM-1t is the first operating ton-scale liquid argon detector for direct search of Dark Matter particles. Developed at CERN as Recognized Experiment RE18, the experiment has been approved in 2010 to be installed in the Spanish underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical completion and s…
▽ More
ArDM-1t is the first operating ton-scale liquid argon detector for direct search of Dark Matter particles. Developed at CERN as Recognized Experiment RE18, the experiment has been approved in 2010 to be installed in the Spanish underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical completion and safety approval until the recent filling of the target vessel with almost 2 ton of liquid argon. This report describes the experimental achievements during commissioning of ArDM and the transition into a stage of first physics data taking in single phase operational mode. We present preliminary observations from this run. A first indication for the background discrimination power of LAr detectors at the ton-scale is shown. We present an outlook for completing the detector with the electric drift field and upgrade of the scintillation light readout system with novel detector modules based on SiPMs in order to improve the light yield.
△ Less
Submitted 10 May, 2015;
originally announced May 2015.
-
Summary of the Second Workshop on Liquid Argon Time Projection Chamber Research and Development in the United States
Authors:
R. Acciarri,
M. Adamowski,
D. Artrip,
B. Baller,
C. Bromberg,
F. Cavanna,
B. Carls,
H. Chen,
G. Deptuch,
L. Epprecht,
R. Dharmapalan,
W. Foreman,
A. Hahn,
M. Johnson,
B. J. P. Jones,
T. Junk,
K. Lang,
S. Lockwitz,
A. Marchionni,
C. Mauger,
C. Montanari,
S. Mufson,
M. Nessi,
H. Olling Back,
G. Petrillo
, et al. (19 additional authors not shown)
Abstract:
The second workshop to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States was held at Fermilab on July 8-9, 2014. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in six t…
▽ More
The second workshop to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States was held at Fermilab on July 8-9, 2014. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in six topical plenary sessions: $i)$ Argon Purity and Cryogenics, $ii)$ TPC and High Voltage, $iii)$ Electronics, Data Acquisition and Triggering, $iv)$ Scintillation Light Detection, $v)$ Calibration and Test Beams, and $vi)$ Software. This document summarizes the current efforts in each of these areas. It primarily focuses on the work in the US, but also highlights work done elsewhere in the world.
△ Less
Submitted 22 April, 2015; v1 submitted 21 April, 2015;
originally announced April 2015.
-
The LBNO long-baseline oscillation sensitivities with two conventional neutrino beams at different baselines
Authors:
LAGUNA-LBNO Collaboration,
:,
S. K. Agarwalla,
L. Agostino,
M. Aittola,
A. Alekou,
B. Andrieu,
F. Antoniou,
R. Asfandiyarov,
D. Autiero,
O. Bésida,
A. Balik,
P. Ballett,
I. Bandac,
D. Banerjee,
W. Bartmann,
F. Bay,
B. Biskup,
A. M. Blebea-Apostu,
A. Blondel,
M. Bogomilov,
S. Bolognesi,
E. Borriello,
I. Brancus,
A. Bravar
, et al. (136 additional authors not shown)
Abstract:
The proposed Long Baseline Neutrino Observatory (LBNO) initially consists of $\sim 20$ kton liquid double phase TPC complemented by a magnetised iron calorimeter, to be installed at the Pyhäsalmi mine, at a distance of 2300 km from CERN. The conventional neutrino beam is produced by 400 GeV protons accelerated at the SPS accelerator delivering 700 kW of power. The long baseline provides a unique o…
▽ More
The proposed Long Baseline Neutrino Observatory (LBNO) initially consists of $\sim 20$ kton liquid double phase TPC complemented by a magnetised iron calorimeter, to be installed at the Pyhäsalmi mine, at a distance of 2300 km from CERN. The conventional neutrino beam is produced by 400 GeV protons accelerated at the SPS accelerator delivering 700 kW of power. The long baseline provides a unique opportunity to study neutrino flavour oscillations over their 1st and 2nd oscillation maxima exploring the $L/E$ behaviour, and distinguishing effects arising from $δ_{CP}$ and matter. In this paper we show how this comprehensive physics case can be further enhanced and complemented if a neutrino beam produced at the Protvino IHEP accelerator complex, at a distance of 1160 km, and with modest power of 450 kW is aimed towards the same far detectors. We show that the coupling of two independent sub-MW conventional neutrino and antineutrino beams at different baselines from CERN and Protvino will allow to measure CP violation in the leptonic sector at a confidence level of at least $3σ$ for 50\% of the true values of $δ_{CP}$ with a 20 kton detector. With a far detector of 70 kton, the combination allows a $3σ$ sensitivity for 75\% of the true values of $δ_{CP}$ after 10 years of running. Running two independent neutrino beams, each at a power below 1 MW, is more within today's state of the art than the long-term operation of a new single high-energy multi-MW facility, which has several technical challenges and will likely require a learning curve.
△ Less
Submitted 2 December, 2014;
originally announced December 2014.
-
Optimised sensitivity to leptonic CP violation from spectral information: the LBNO case at 2300 km baseline
Authors:
LAGUNA-LBNO Collaboration,
:,
S. K. Agarwalla,
L. Agostino,
M. Aittola,
A. Alekou,
B. Andrieu,
F. Antoniou,
R. Asfandiyarov,
D. Autiero,
O. Bésida,
A. Balik,
P. Ballett,
I. Bandac,
D. Banerjee,
W. Bartmann,
F. Bay,
B. Biskup,
A. M. Blebea-Apostu,
A. Blondel,
M. Bogomilov,
S. Bolognesi,
E. Borriello,
I. Brancus,
A. Bravar
, et al. (136 additional authors not shown)
Abstract:
One of the main goals of the Long Baseline Neutrino Observatory (LBNO) is to study the $L/E$ behaviour (spectral information) of the electron neutrino and antineutrino appearance probabilities, in order to determine the unknown CP-violation phase $δ_{CP}$ and discover CP-violation in the leptonic sector. The result is based on the measurement of the appearance probabilities in a broad range of ene…
▽ More
One of the main goals of the Long Baseline Neutrino Observatory (LBNO) is to study the $L/E$ behaviour (spectral information) of the electron neutrino and antineutrino appearance probabilities, in order to determine the unknown CP-violation phase $δ_{CP}$ and discover CP-violation in the leptonic sector. The result is based on the measurement of the appearance probabilities in a broad range of energies, covering t he 1st and 2nd oscillation maxima, at a very long baseline of 2300 km. The sensitivity of the experiment can be maximised by optimising the energy spectra of the neutrino and anti-neutrino fluxes. Such an optimisation requires exploring an extended range of parameters describing in details the geometries and properties of the primary protons, hadron target and focusing elements in the neutrino beam line. In this paper we present a numerical solution that leads to an optimised energy spectra and study its impact on the sensitivity of LBNO to discover leptonic CP violation. In the optimised flux both 1st and 2nd oscillation maxima play an important role in the CP sensitivity. The studies also show that this configuration is less sensitive to systematic errors (e.g. on the total event rates) than an experiment which mainly relies on the neutrino-antineutrino asymmetry at the 1st maximum to determine the existence of CP-violation.
△ Less
Submitted 1 December, 2014;
originally announced December 2014.
-
LBNO-DEMO: Large-scale neutrino detector demonstrators for phased performance assessment in view of a long-baseline oscillation experiment
Authors:
L. Agostino,
B. Andrieu,
R. Asfandiyarov,
D. Autiero,
O. Bésida,
F. Bay,
R. Bayes,
A. M. Blebea-Apostu,
A. Blondel,
M. Bogomilov,
S. Bolognesi,
S. Bordoni,
A. Bravar,
M. Buizza-Avanzini,
F. Cadoux,
D. Caiulo,
M. Calin,
M. Campanelli,
C. Cantini,
L. Chaussard,
D. Chesneanu,
N. Colino,
P. Crivelli,
I. De Bonis,
Y. Déclais
, et al. (90 additional authors not shown)
Abstract:
In June 2012, an Expression of Interest for a long-baseline experiment (LBNO) has been submitted to the CERN SPSC. LBNO considers three types of neutrino detector technologies: a double-phase liquid argon (LAr) TPC and a magnetised iron detector as far detectors. For the near detector, a high-pressure gas TPC embedded in a calorimeter and a magnet is the baseline design. A mandatory milestone is a…
▽ More
In June 2012, an Expression of Interest for a long-baseline experiment (LBNO) has been submitted to the CERN SPSC. LBNO considers three types of neutrino detector technologies: a double-phase liquid argon (LAr) TPC and a magnetised iron detector as far detectors. For the near detector, a high-pressure gas TPC embedded in a calorimeter and a magnet is the baseline design. A mandatory milestone is a concrete prototyping effort towards the envisioned large-scale detectors, and an accompanying campaign of measurements aimed at assessing the detector associated systematic errors. The proposed $6\times 6\times 6$m$^3$ DLAr is an industrial prototype of the design discussed in the EoI and scalable to 20 kton or 50~kton. It is to be constructed and operated in a controlled laboratory and surface environment with test beam access, such as the CERN North Area (NA). Its successful operation and full characterisation will be a fundamental milestone, likely opening the path to an underground deployment of larger detectors. The response of the DLAr demonstrator will be measured and understood with an unprecedented precision in a charged particle test beam (0.5-20 GeV/c). The exposure will certify the assumptions and calibrate the response of the detector, and allow to develop and to benchmark sophisticated reconstruction algorithms, such as those of 3-dimensional tracking, particle ID and energy flow in liquid argon. All these steps are fundamental for validating the correctness of the physics performance described in the LBNO EoI.
△ Less
Submitted 14 September, 2014;
originally announced September 2014.
-
First operation and performance of a 200 lt double phase LAr LEM-TPC with a 40x76 cm^2 readout
Authors:
A. Badertscher,
A. Curioni,
U. Degunda,
L. Epprecht,
A. Gendotti,
S. Horikawa,
L. Knecht,
D. Lussi G. Natterer,
K. Nguyen,
F. Resnati,
A. Rubbia,
T. Viant
Abstract:
In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the readout consists of a $40\times 76$ cm$^2$ LEM and 2D projective anode to multiply and collect drifting charges. Scintillation light is detected by means of cryogen…
▽ More
In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the readout consists of a $40\times 76$ cm$^2$ LEM and 2D projective anode to multiply and collect drifting charges. Scintillation light is detected by means of cryogenic PMTs positioned below the cathode. To record both charge and light signals, we have developed a compact acquisition system, which is scalable up to ton-scale detectors with thousands of charge readout channels. The acquisition system, as well as the design and the performance of custom-made charge sensitive preamplifiers, are described. The complete experimental setup has been operated for a first time during a period of four weeks at CERN in the cryostat of the ArDM experiment, which was equipped with liquid and gas argon purification systems. The detector, exposed to cosmic rays, recorded events with a single-channel signal-to-noise ratio in excess of 30 for minimum ionising particles. Cosmic muon tracks and their $δ$-rays were used to assess the performance of the detector, and to estimate the liquid argon purity and the gain at different amplification fields.
△ Less
Submitted 21 January, 2013;
originally announced January 2013.
-
Performance of a 250L liquid Argon TPC for sub-GeV charged particle identification
Authors:
J-PARC T32 collaboration,
:,
O. Araoka,
A. Badertscher,
A. Curioni,
S. Di Luise,
U. Degunda,
L. Epprecht,
L. Esposito,
A. Gendotti,
T. Hasegawa,
S. Horikawa,
K. Kasami,
N. Kimura,
L. Knecht,
T. Kobayashi,
C. Lazzaro,
D. Lussi,
M. Maki,
A. Marchionni,
T. Maruyama,
A. Meregaglia,
T. Mitani,
Y. Nagasaka,
J. Naganoma
, et al. (17 additional authors not shown)
Abstract:
We have constructed a liquid Argon TPC detector with fiducial mass of 150 kg as a part of the R&D program of the next generation neutrino and nucleon decay detector. This paper describes a study of particle identification performance of the detector using well-defined charged particles (pions, kaons, and protons) with momentum of ~800 MeV/$c$ obtained at J-PARC K1.1BR beamline.
We have constructed a liquid Argon TPC detector with fiducial mass of 150 kg as a part of the R&D program of the next generation neutrino and nucleon decay detector. This paper describes a study of particle identification performance of the detector using well-defined charged particles (pions, kaons, and protons) with momentum of ~800 MeV/$c$ obtained at J-PARC K1.1BR beamline.
△ Less
Submitted 8 June, 2012; v1 submitted 6 June, 2012;
originally announced June 2012.
-
The ArDM experiment
Authors:
ArDM Collaboration,
C. Amsler,
A. Badertscher,
V. Boccone,
N. Bourgeois,
A. Bueno,
M. C. Carmona-Benitez,
M. Chorowski,
W. Creus,
A. Curioni,
E. Daw,
U. Degunda,
A. Dell'Antone,
M. Droge,
L. Epprecht,
C. Haller,
M. Haranczyk,
S. Horikawa,
L. Kaufmann,
J. Kisiel,
L. Knecht,
M. Laffranchi,
J. Lagoda,
C. Lazzaro,
P. Lightfoot
, et al. (29 additional authors not shown)
Abstract:
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, includin…
▽ More
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.
△ Less
Submitted 28 June, 2010;
originally announced June 2010.