CERN Accelerating science

CERN Document Server 找到 2,038 笔记录  1 - 10下一个最後  跳到记录: 检索需时 0.37 秒. 
1.
Commissioning of the 4 K Outer Cryostat for the CUORE Experiment / Ferri, E (INFN, Milan Bicocca ; Milan Bicocca U.) ; Alessandria, F (INFN, Milan) ; Biassoni, M (INFN, Milan Bicocca ; Milan Bicocca U.) ; Bucci, C (Gran Sasso) ; Ceruti, G (INFN, Milan Bicocca) ; Chiarini, A (INFN, Genoa) ; Clemenza, M (INFN, Milan Bicocca ; Milan Bicocca U.) ; Cremonesi, O (INFN, Milan Bicocca ; Milan Bicocca U.) ; Datskov, V (CERN) ; Dossena, S (INFN, Milan Bicocca ; Milan Bicocca U.) et al.
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment. The CUORE detector is an array of 988 TeO crystals arranged in a cylindrical, compact, and granular structure of 19 towers. [...]
2014 - 7 p. - Published in : J. Low Temp. Phys. 176 (2014) 952-958
2.
The 4 K outer cryostat for the CUORE experiment: construction and quality control / Alessandria, F. (INFN, Milan) ; Biassoni, M. (INFN, Milan Bicocca ; Milan Bicocca U.) ; Ceruti, G. (INFN, Milan Bicocca) ; Chiarini, A. (INFN, Bologna) ; Clemenza, M. (INFN, Milan Bicocca ; Milan Bicocca U.) ; Cremonesi, O. (INFN, Milan Bicocca) ; Datskov, V. (CERN) ; Dossena, S. (INFN, Milan Bicocca) ; Faverzani, M. (INFN, Milan Bicocca ; Milan Bicocca U.) ; Ferri, E. (INFN, Milan Bicocca ; Milan Bicocca U.) et al.
The external shell of the CUORE cryostat is a large cryogen-free system designed to host the dilution refrigerator and the bolometers of the CUORE experiment in a low radioactivity environment. The three vessels that form the outer shell were produced and delivered to the Gran Sasso underground Laboratories in July 2012. [...]
arXiv:1306.1351.- 2013 - 8 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 727 (2013) 65-72 Fulltext: PDF; External link: Preprint
3.
Results of CUORE / CUORE Collaboration
The Cryogenic Underground Observatory for Rare Events (CUORE) at the Laboratori Nazionali del Gran Sasso, Italy, is the world's largest bolometric experiment. The detector consists of an array of 988 TeO$_{2}$ crystals, for a total mass of 742 kg. [...]
arXiv:1905.07667.- 2019 - 6 p. - Published in : (2019) , pp. 189-194 Fulltext: PDF;
In : 54th Rencontres de Moriond on Electroweak Interactions and Unified Theories, La Thuile, Italy, 16 - 23 Mar 2019, pp.189-194
4.
Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE / CUORE Collaboration
The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta ($0 \nu \beta \beta$) decay. [...]
arXiv:2104.06906.- 2022-04-06 - 6 p. - Published in : Nature Fulltext: jhg - PDF; 2104.06906 - PDF; External links: Interactions.org; Nature News and Views article
5.
Science and technology of BOREXINO: A Real time detector for low-energy solar neutrinos : A Real Time Detector for Low Energy Solar Neutrinos / Borexino Collaboration
BOREXINO, a real-time device for low energy neutrino spectroscopy is nearing completion of construction in the underground laboratories at Gran Sasso, Italy (LNGS). The experiment's goal is the direct measurement of the flux of 7Be solar neutrinos of all flavors via neutrino-electron scattering in an ultra-pure scintillation liquid. [...]
hep-ex/0012030.- 2002 - 51 p. - Published in : Astropart. Phys. 16 (2002) 205-234 Access to fulltext document: PDF PS; External link: hep-ex/0012030 PDF
6.
Towards a new Liquid Argon Imaging Chamber for the MODULAr project / Angeli, D (Modena U.) ; Baibussinov, B (INFN, Padua) ; Baldo-Ceolin, M (Padua U. ; INFN, Padua) ; Battistoni, G (INFN, Milan) ; Benetti, P (Pavia U. ; INFN, Pavia) ; Borio, A (Pavia U.) ; Calligarich, E (INFN, Pavia) ; Cambiaghi, M (Pavia U. ; INFN, Pavia) ; Cavanna, F (L'Aquila U. ; Gran Sasso) ; Centro, S (Padua U. ; INFN, Padua) et al.
2009 - Published in : JINST 4 (2009) P02003 SISSA/IOP Open Access article: PDF;
7.
MOSCAB: A geyser-concept bubble chamber to be used in a dark matter search / MOSCAB Collaboration
The MOSCAB experiment (Materia OSCura A Bolle) uses the "geyser technique", a variant of the superheated liquid technique of extreme simplicity. Operating principles of the new dark matter detector and technical solutions of the device are reported in detail. [...]
arXiv:1708.00101.- 2017-11-09 - 11 p. - Published in : Eur. Phys. J. C 77 (2017) 752 Article from SCOAP3: scoap3-fulltext - PDF; scoap - PDF; Fulltext: PDF;
8.
Thermal and fast neutron detection with two CLYC scintillators / Giaz, A (Milan U. ; INFN, Milan) ; Camera, F (Milan U. ; INFN, Milan) ; Blasi, N (Milan U. ; INFN, Milan) ; Brambilla, S (Milan U. ; INFN, Milan) ; Ceruti, S (Milan U. ; INFN, Milan) ; Million, B (Milan U. ; INFN, Milan) ; Pellegri, L (Milan U. ; INFN, Milan) ; Riboldi, S (Milan U. ; INFN, Milan)
Geneva : CERN, 2015 Published version from CERN: PDF;
In : 14th International Conference on Nuclear Reaction Mechanisms, Villa Monastero, Varenna, Italy, 15 - 19 Jun 2015, pp.95
9.
Flux Modulations seen by the Muon Veto of the GERDA Experiment / GERDA Collaboration
The GERDA experiment at LNGS of INFN is equipped with an active muon veto. The main part of the system is a water Cherenkov veto with 66~PMTs in the water tank surrounding the GERDA cryostat. [...]
arXiv:1601.06007.- 2016-11 - 7 p. - Published in : Astropart. Phys. 84 (2016) 29-35 Preprint: PDF; External link: Preprint
10.
Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector / ICARUS Collaboration
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes, Hamamatsu model R5912-MOD, suitable for cryogenic applications. [...]
arXiv:1807.08577; FERMILAB-PUB-18-390-ND.- 2018-10-26 - 19 p. - Published in : JINST 13 (2018) P10030 Fulltext: fulltext1683520 - PDF; Babicz_2018_J._Inst._13_P10030 - PDF; fermilab-pub-18-390-nd - PDF; 1807.08577 - PDF; Fulltext from Publisher: PDF; Preprint: PDF; External link: Fermilab Library Server (fulltext available)

没有寻找到什么? 尝试在以下的服务器查寻:
recid:2124606 在 Amazon
recid:2124606 在 CERN EDMS
recid:2124606 在 CERN Intranet
recid:2124606 在 CiteSeer
recid:2124606 在 Google Books
recid:2124606 在 Google Scholar
recid:2124606 在 Google Web
recid:2124606 在 IEC
recid:2124606 在 IHS
recid:2124606 在 INSPIRE
recid:2124606 在 ISO
recid:2124606 在 KISS Books/Journals
recid:2124606 在 KISS Preprints
recid:2124606 在 NEBIS
recid:2124606 在 SLAC Library Catalog