LTE eNodeB Commissioning
LTE eNodeB Commissioning
LTE eNodeB Commissioning
On completion of this course, you should be able to: Know the way to do the commissioning with USB Know the commissioning procedure
c) When you save the eNodeB software and data configuration file to the USB storage device, ensure that the locking switch on the USB storage device is disabled.
d) eNodeB software is copied to USB:/eNodeB/software/ (Software is already stored on the USB Stick for Subcontractors)
d) eNodeB software is copied to USB:/eNodeB/software/ (Software is already stored on the USB Stick for Subcontractors)
e) Subcontractor will get eNodeB configuration script and PreInfo.xml from Huawei engineer and then copy it to USB directory : /eNodeB/
Note: The name of the configuration file must be CFGDATA.xml Please verify the eNodeB ID and Name by opening the CFG file before the Commissioning (right-click on file and select edit)!!!
Software&Configuration File
Software&Configuration File
a) Ensure that RRU has been already powered on and connected with BBU by CPRI fiber cable. Check eNodeB hardware and make sure that the LED light is normal.
Power on the eNodeB After the eNodeB is started, it automatically upgrades the software and download the data configuration file. LED will be flashing fast on both USB and LMPT board (RUN). After about 20 minutes, check the status of the LED on the USB disk. LED being red for long means the upgrade succeeds. After Checking the Status of LEDs and ensuring that the eNodeB is running properly, Unplug the USB disk.
b) Change IP settings of Laptop as seen below & disable any proxy server settings
f) Open Internet Explorer and type in 192.168.0.49 to re-login to eNodeB again Username:admin Password:admin123 *Notes: If you are prompted to change the password, please change to Enodeb123
e) Check Active Alarms via MML command (LST ALMAF:;) , there should be no active alarm.
f) Check Active Alarms by clicking on Alarm Tab, then Engineering should be the same alarm status as in alarm list)
THANK YOU