SDH 2500 Hardware Class
SDH 2500 Hardware Class
Transmission System
System Overview
Contents
MUTE TEST
RUN
ALM
1 2 3 4
• Serial interfaces
• Ethernet interfaces /BNC
• F1 Interface (data user channel)
• Order wire phone interface
• Power supply interface
• External clock interface
Board Insertion Area
Board Insertion Area XCS:
1+1 protection
at the Front Subrack
SCC:
SCC board
I I I I I I X X I I I I I I S I
IUP:
U U U U U U C C U U U U U U C U protection slot
1 2 3 4 5 6 S S 7 8 9 1 1 1 C P IU1~IU4,IU9~IU12:
0 1 2 boards need
Optical Fiber/electrical cable leading area Electrical
FAN interface
/
I
P
U
622Mbit/s
I
2
U
622Mbit/s I
3
U
622Mbit/s
I
4
U
2.5Gbit/s(Share)
I
5
U
2.5Gbit/s
I
6
U
2.5Gbit/s
XCS
XCS
Fiber Routing
I
7
U
2.5Gbit/s
I
8
U
2.5Gbit/s
I
9
U
2.5Gbit/s(Share)
I
0
1
U
622Mbit/s
I
1
1
U
622Mbit/s
I
2
1
U
622Mbit/s(Share)
Board Insertion Area
C
C
I
I
P
P
U
U
Sub-rack (Rare View)
• Slot Assignment &
Relation F L L L L L L L L
B T
1 T T T T T T T
U
/
LTU1 IU1 U U U U U U U /
L F
LTU2 IU2 P B
LTU3 IU3 D 2
LTU4 IU4 R
9 8 7 6 5 4 3 2 1
LTU5 IU9 E
LTU6 IU10 I
P
LTU7 IU11 C
LTU8 IU12 10
Back of fan
Access Capacity of IU Slot
IU
1 2 3 4 5 6 7 8 9 10 11 12/
P
Slot
4 4 4 16 16 16 16 16 16 4 4 4
Capacity
Share Share
SDH IU IU SDH
Ethernet IU IU SDH
es sing
proc
T U-PTR
d
H an
LP O
The common alarms of PDH unit
Alarm
Alarm name Alarm reason
level
T_ALOS No E1 service is accessed
Critical alarm e.g. R-LOS
Major happens
TU_AIS
Wrong service configuration
Faulty PDH board
The opposite node receives such
LP_RDI
alarms as TU_AIS and TU_LOP
Minor
LP-BBE happens on the opposite
LP_REI
node
SDH Unit
Indicator Status Color Description
Flashing 5 times per
The board is not in working state
second
S CC
d to
S en
Collect Alarm and
performance
……
STM-16
es sing
roc
-P TR p
d AU
O H an
lllllllllllllllllllllllllll
0323501022000005 -SS62S1603
lllllllllllll
IN
RUN
ALM
OUT
S16
indicators
SC/PC connector
SDH Access Unit
llllllllll llllllllllllll
lll0323501022000005 llllllll lllll
-SS62S1603
IN
OUT
RUN
ALM
SL4
IN
OUT
ALM
RUN
SL1
SDH Access Unit
Unit
SDH
Access
llllllllllllllllllllllllllllllllllllllll
0323501022000005 -SS62SDE01
IN1
ALM
RUN
IN2
OUT2
OUT1
SDE
llllllllllllllllllllllllllllllllllllllll
0323501022000005 -SS62SQE01
ALM
RUN
SQE
In4
In3
In2
In1
Out4
Out3
Out2
Out1
SDH Access Unit
• SDE
– No need interface board
– 2×STM-1 electrical interfaces
on the front panel are used
– In all line slots
• SQE
– Need interface board LPSW
– No electrical interfaces on the front
panel
SDH Access Unit
The optical port parameters of S16
SDH unit
Commands
PDH unit Alarm and
performance
NMS
Ethernet unit
Other NE
System Control &
Communication Unit
Functions:
ON
OFF
D7 D6 D5 D4 D3 D2 D1 D0
ID=9, IP=129.9.0.9
System Control & Communication Unit
Indicator
SCC board has one more indicator ETN (yellow)
-- indicator for communication status
status
on--connection between NE and NM is ok
flash--data transmitted between NE and NM
when there's a call dialing in, the alarm indicator will
quick flashes.
System Control &
Communication Unit
The common alarms of SCC unit
Alarm
Alarm name Alarm reason
level
Critical NESTATE_INSTALL NE is in the installing state.
Inserted board and the configured
WRG_BD_TYPE
board are mismatched.
Major NESF_LOST Host software is lost.
APS_INDI Protection switching Indication
Minor FAN_FAIL Fan failed
System Control & Communication Unit
NMS
Ring A Ring B
NE B NE D NE B NE D
NE C NE C
X.25
interface
Modem
Serial
Modem
interface
PSTN PSTN
Modem Modem
Cross-connect Unit
SDH unit PDH unit Ethernet unit CC
S
d to
S en
Collect Alarm and
performance
High-order cross-connect
matrix (96×96 VC-4)
XCS
RUN
ALM
With SCC
get control command
send running information