Automation and Drives

WinCC Flexible/Sm@rtService

 Sending of e-mail
on basis of messages and events

 Maintenance functions over Web


Standard HTML pages with service and
maintenance functions as well as diagnostics info

 Remote operation over Web


Complete remote control of an HMI system
using the Internet Explorer

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Learning targets

The participant will learn about

• the contents of Sm@rtService


• the procedure for configuring
various Sm@rtService features.

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 1: Sending E-mail Overview (1 of 2)

Triggered by:  Message


 Configured system
function Internet
Contents:  Message text SMTP
 Configured text server

Analog/ DSL modem

Ethernet

Sending e-mails
Ethernet

SMS (Cell Phone)


 Not directly possible
 Only if SMTP server can
convert an e-mail to SMS

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 1: Sending E-mail Overview (2 of 2)

 Application
 In order to reduce downtimes, the HMI panel sends messages or other configured
text information as an e-mail to the support personnel

 General procedure
 The connection data for an SMTP server and a sender name are stored in the
HMI panel (Control Panel or configuration)
 A receiver mail address can be assigned to a message class in the configuration,
or
system function "SendEmail" can be configured as a function for any events
((e.g. receipt of a specific message)

 Requirements
 Ethernet interface
 HMI panel must be able to access an SMTP server over the Ethernet
 One enabling license per HMI panel

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 1: Sending E-mail - Configuration

HMI Panel SMTP Server

1. Enter access data of SMTP server  Authentication possible, but no


(2 possibilities) scanning of a user password
 In the configuration
Device settings
 Control Panel
WinCC Internet Settings

2. Configure sending of e-mail


 Assign to a message class
 Configure system function
"SendEmail" for an event

3. Upload Sm@rtService license


 AutomationLicenseManager

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 1: Sending E-mail


Configuration of HMI Panel (1 of 2)
1. Enter access data of SMTP server (2 possibilities)
 In the configuration or  Control Panel
Device settings WinCC Internet Settings

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 1: Sending E-mail


Configuration of HMI Panel (2 of 2)
2. Configure sending of e-mail
 Assign to a message class or/and  Configure system function
"SendEmail" for an event

E-mail address
of receiver

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 2: Maintenance Functions Over Web


Overview (1 of 2)
Standard HTML pages with service and maintenance functions as well as diagnostics info

Internet or LAN
 Calling of HTML pages of HMI panel Internet
 You can expand the standard pages
included in the scope of delivery

Ethernet

Ethernet

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 2: Maintenance Functions Over Web


Overview (2 of 2)
 Application
 In order to reduce downtimes, the support personnel can call diagnostics
information directly from the HMI panel without having to be on site
 Access security through scanning of passwords set in the Control Panel of the
HMI panel

 General procedure
 HTML pages are downloaded to the HMI panel together with the configuration
 These HTML pages can be downloaded and viewed using a Web browser (e.g.
Internet Explorer)

 Requirements
 Ethernet interface
 HMI panel must be accessible to support personnel over Ethernet
LAN - must be in same network
Internet - Internet gateway !!! Observe network security !!!
 One enabling license per HMI panel

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 2: Maintenance Functions Over Web


HTML Pages
Standard functions
 Remote operation of HMI device
 Import/export of recipes and
password lists
 Starting and stopping of Runtime
 Device status
 System diagnostics
 Web browser
(password protection)

L pages
d H TM nted
n r
da ppleme L
S t a
n be su wn HTM
ca o ur o
h y
wit
s
page

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 2: Maintenance Functions Over Web


Configuration

HMI Panel Service PC

1. Activate MiniWebServer and 1. Install Web browser


transmission of HTML pages in the  e.g. Internet Explorer
HMI panel configuration
 Device settings 2. Call HTML pages
Sm@rtService: HTML pages  http://xxx.xxx.xxx.xxx 

2. Set access passwords on HMI panel


 Control Panel IP address
WinCC Internet Settings

3. Upload Sm@rtService license


 AutomationLicenseManager

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 2: Maintenance Functions Over Web


Configuration of HMI Panel (1 of 2)

1. Activate MiniWebServer and transmission of HTML pages in


the HMI panel configuration

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 2: Maintenance Functions over Web


Configuration of HMI panel (2 of 2)
2. Set access protection
 Different users+passwords+privileges can be recorded
 Control Panel
Current administrator
password

Assigned
user
privileges

Default user: Administrator password = 100

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 2: Maintenance Functions Over Web


Call HTML Pages
Name
or IP address
of HMI panel

Requirements
 Internet Explorer V6.0 SP1 and
higher
 HMI panel can be accessed
"ping 192.168.111.51"

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 2: Maintenance Functions Over Web


Adapt HTML Pages (1 of 2)
File name - Panels: WebContent.zip
 Per HMI panel class: wccf_installation_path\WinCC flexible 2007\Transfer\

PC Runtime:
 wccf_installation_path\WinCC flexible 2007 Runtime\WebContent\

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 2: Maintenance Functions Over Web


Adapt HTML Pages (2 of 2)
Output of device tags to HTML pages
e.g. output of device name (parameter "HostName"): See list for
<HTML> available
<HEAD> <TITLE> MiniWeb </TITLE> </HEAD> tags
<BODY >
Welcome on <MWSL><!-- write(GetVar("HostName")); --></MWSL>
</BODY>
</HTML>

Output of configuration tags to HTML pages


Name of tag
Dummy value for the tag is its name.
from
e.g. output of value of tag with the name "SetpointSpeed" configuration
<HTML>
<HEAD> <TITLE> MiniWeb </TITLE> </HEAD>
<BODY > Currently defined setpoint speed:
<MWSL><!-- write(GetVar("SetpointSpeed")); --></MWSL>
</BODY>
</HTML>
SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Exercise: Maintenance Functions Over Web

 Neighboring stations access the HTML pages of the neighboring


PC
 All activate transmission of the HTML pages

 Internet-Explorer
Calling of HTML pages of neighboring PC

Name
or IP address
of neighboring PC

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 3: Remote Operation Over Web Overview


(1 of 3)
Complete remote control of an HMI system using the Internet Explorer Tou
ch
Internet or LAN
or
PC p a n
Ru els
 Complete remote control
Internet
n t im
 VNC access e
 Internet Explorer

Ethernet

Without
panel
keyboard

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 3: Remote Operation Over Web Overview


(2 of 3)
Ke
Complete remote control of an HMI system using the SmartClient.exe yp
ane
Internet or LAN ls
 Complete remote control
 VNC access Internet
 SmartClient.exe

Start > SIMATIC > WinCCflexible2005Runtime > Sm@rtViewer


Ethernet With
panel
keyboard

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 3: Remote Operation Over Web Overview


(3 of 3)
 Application
 In order to reduce downtimes, the support personnel can carry out operations on the
panel without having to be on site
 Access security through scanning of passwords set in the Control Panel of the HMI
panel

 General procedure
 The HMI panel is accessible via remote VNC access
 The service PC is the remote keyboard and screen of the HMI panel
 Only one station has operator privileges at any one moment
(operation on the HMI panel has priority)

 Requirements
 Ethernet interface
 HMI panel must be accessible to support personnel over Ethernet
LAN - must be in same network
Internet - Internet gateway !!! Observe network security !!!
 Sm@rtServer must be activated on the HMI panel
 One enabling license
per HMI panel

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 3: Remote Operation Over Web


Configuration
HMI Panel Service PC

1. Activate remote access in the server 1. Install Web browser and Java
configuration RT Ev
 Device settings  e.g. Internet Explorer
Start Sm@rtServer  Java Runtime Environment
or
2. Set access passwords and Java Install Sm@rtViewer
Applet download on HMI panel  SmartClient.exe
 Control Panel
WinCC Internet Settings 2. Call remote control
 With Internet Explorer
3. Upload Sm@rtService license http://xxx.xxx.xxx.xxx:5800 
 AutomationLicenseManager  With Sm@rtViewer
Server: xxx.xxx.xxx.xxx 
IP address

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 3: Remote Operation Over Web


Configuration of HMI panel (1 of 2)

1. Activateremote access in the server configuration


 Start Sm@rtServer

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 3: Remote Operation Over Web


Configuration of HMI panel (2 of 2)
2. Set access passwords for Java Applet-Download
 Max. two different passwords can be set
 Control Panel
Timeout for
change in
Operation on HMI panel always
operator access has priority
to service PC

Passwords for Password for


operator access via forced operator
Sm@rtServer access
Default password: 100 Only SmartClient.exe

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 3: Call Remote Control


Internet Explorer

Password 1|2 from


WinCC Internet settings

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Task 3: Call Remote Control


SmartClient.exe
Start > SIMATIC > WinCCflexible2007Runtime > Sm@rtViewer Password 1|2 from
WinCC Internet settings

With device layout


and simulation of
function keyboard

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice
Automation and Drives

Exercise: Remote Operation Over Web

 Neighboring stations are remote-controlled


 All activate the remote access in the configuration
 Start Sm@rtServer

 Internet-Explorer
Calling of remote control of neighboring HMI panel

Name
or IP address
of neighboring PC

SITRAIN™
WinCC flexible Optionen /Sm@rtService 06/2007
© Siemens AG 2007 - Subject to change without prior notice