You are on page 1/ 21

IFM Profile

Sensor
OPD101
Configuration
Prepared by: Thien Dang
Tables of
Contents
 Purpose
 Topics
| Purpose

● The purpose of this document is providing:


■ An overview of IFM Profile Sensor OPD101.
■ How to config and troubleshoot OPD101.

© Copyright First Solar, Inc.


3
First Solar Proprietary & Confidential - General
| Topics
I. General description
II. Electrical connection
III. Configuration
IV. Troubleshooting
V. Appendix

© Copyright First Solar, Inc.


4
First Solar Proprietary & Confidential - General
I. General description
1. Overview
The sensor projects a laser line onto the object and determines the
height profile of the object along the laser line.
* Note: The object to be detected has to be in the sensor's
operating range.

The sensor has a trapezoidal operating


Z direction

range with the following dimensions:


• distance to the sensor (Z direction): 150…
300 mm

© Copyright First Solar, Inc.


• length of the profile (X direction):
– for an object distance of 150 mm: 45 mm
– for an object distance of 300 mm: 90 mm
X direction
5
First Solar Proprietary & Confidential - General
I. General description
2. ROI (Region of Interest):

The two ROIs (regions of


interest) are indicated by
two pairs of green markers

© Copyright First Solar, Inc.


6
First Solar Proprietary & Confidential - General
II. Electrical connection
 In the operating mode
“Continuous mode”, OUT1 and
OUT2 are configured as
complementary switching
outputs.
 In the operating mode “Triggered
mode”, OUT2 is configured as
ready signal.

© Copyright First Solar, Inc.


7
First Solar Proprietary & Confidential - General
III. Configuration

© Copyright First Solar, Inc.


8
First Solar Proprietary & Confidential - General
III. Configuration
 Some notes when setting parameters for new sensor:

 The distance from Sensor to plate is 250mm

 The Laser line of Sensor on the background is the plate with


out the Pigtail cable
 Follow this procedure and keep threshold value is default 90%

© Copyright First Solar, Inc.


9
First Solar Proprietary & Confidential - General
III. Configuration
 After teaching to check the Sensor indicator:

 The orange light is ON when sensor is not detecting the


Pigtail cable: Out1= OFF, Out2 = ON
 The orange light is OFF when Sensor is detecting the Pigtail
cable: Out1 = ON, Out2 = OFF
 Out1 link to PLC tag: LaserSensor2DetectCable

© Copyright First Solar, Inc.


 Out2 link to PLC tag: LaserSensor2NoDetectCable

10
First Solar Proprietary & Confidential - General
III. Configuration

© Copyright First Solar, Inc.


11
First Solar Proprietary & Confidential - General
If the object to be detected is outside
the operating range (e.g. closer than
150 mm or farther away than 300
mm), the teaching process is stopped.
The message [Object out of range]
appears for three seconds. Afterwards,
a new teaching process is started.

© Copyright First Solar, Inc.


12
First Solar Proprietary & Confidential - General
III. Configuration

© Copyright First Solar, Inc.


13
First Solar Proprietary & Confidential - General
III. Configuration

© Copyright First Solar, Inc.


14
First Solar Proprietary & Confidential - General
IV. Troubleshooting

© Copyright First Solar, Inc.


15
First Solar Proprietary & Confidential - General
IV. Troubleshooting

© Copyright First Solar, Inc.


16
First Solar Proprietary & Confidential - General
V. Appendix

© Copyright First Solar, Inc.


17
First Solar Proprietary & Confidential - General
V. Appendix

© Copyright First Solar, Inc.


18
First Solar Proprietary & Confidential - General
V. Appendix

© Copyright First Solar, Inc.


19
First Solar Proprietary & Confidential - General
V. Appendix

© Copyright First Solar, Inc.


20