0% found this document useful (0 votes)
19 views29 pages

Management Review Qhs

Uploaded by

Aires Luzada
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views29 pages

Management Review Qhs

Uploaded by

Aires Luzada
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 29

QUALITY, HEALTH

& SAFETY
DEPARTMENT

PROCESS PERFORMANCE AND CONFORMITY OF PRODUCTS AND SERVICES


PROCESS PERFORMANCE AND CONFORMITY OF PRODUCTS AND SERVICES

To t a l n u m b e r o f d e l i v e r e d S O v s To t a l N u m b e r o f C F R

Delivered CFR
Total number of SS tank delivered Total number of Customer feedback
from march to May 2024 from March to May 2024

908 units 15 units


QUALITY ISSUES MARCH
350

300 296

250 MARCH 2024


Total SO Delivered: 296 Units
200 Total CFR Received: 3 Reports
Status: CLOSED
Percentage: 1.01% PASSED
150

100
Target: ​
• Reduce customer complaints due
50 to quality issues to 5% ​
3 0
• Zero customer claims/Returned items​
0
Series1

NC Delivered
QUALITY ISSUES MARCH

CFR Control No.: 000102

Customer Name: Agua Trade


Tank: FTH 10000L
Reported Date: 03/04/2024
Accomplished Date: 03/05/2024

Status: CLOSED

Issue: Burst Top Cover


Investigation: Burst originates in the TOP
area of the tank. Poor seam weld application
of the crown cover
Corrective Action: Re-weld on site and re
apply silicone
QUALITY ISSUES MARCH

CFR Control No.: 000103

Customer Name: ORO SOLID


Tank: FTR-2000L
Reported Date: 03/19/2024
Accomplished Date: 03/20/2024

Status: CLOSED

Issue: Leaking
Investigation: Leaking originates in the
bottom area of the tank. Poor silicone
sealant application upon on-site verification.
Corrective Action: Re-application of
Silicone Sealant
QUALITY ISSUES MARCH

CFR Control No.: 000104

Customer Name: Cagayan Pioneer


Hardware
Tank: FTR-920 L
Reported Date: 03/22/2024
Accomplished Date: 03/24/2024

Status: CLOSED

Issue: Leaking
Investigation: Leaking on welded bottom
area. Poor application of Silicone Sealant is
the closest reason.
Corrective Action: Re-application of
Silicone Sealant on leaking area.
QUALITY ISSUES APRIL
350

300
312
APRIL 2024
Total SO Delivered: 312 Units
Total CFR Received: 8 Reports
250
Status: CLOSED
Percentage: 2.6% PASSED
200

Target: ​
150
• Reduce customer complaints due
100
to quality issues to 5% ​
• Zero customer claims/Returned items​
50

8
0
Series1

NC Delivered
QUALITY ISSUES APRIL

CFR Control No.: 000116

Customer Name: Arnold Johanna


Fernandez
Tank: FTR 1000
Reported Date: 04/30/2024
Accomplished Date: 05/02/2024

Status: CLOSED

Issue: Loosed Tank


Investigation: In-accurate tank stand
dimension
Corrective Action: Tank Replacement
QUALITY ISSUES APRIL

CFR Control No.: 000115

Customer Name: Weld Powertools CDO


Tank: FTR 4600L LEAK
Reported Date: 04/24/2024
Accomplished Date: 05/07/2024

Status: CLOSED

Issue: Leaking
Investigation: Leaking on the vertical
welded joint body of the tank
Corrective Action: Re-application of
silicone sealant on site.
QUALITY ISSUES APRIL

CFR Control No.: 000114

Customer Name: Strength Hardware


Tank: FTR 2000L
Reported Date: 04/24/2024
Accomplished Date: 05/07/2024

Status: CLOSED

Issue: Leaking due to hole/no paint on the


welded part.

Corrective Action: application of devcon


and silicone sealant.
QUALITY ISSUES APRIL

CFR Control No.: 000112

Customer Name: Ismael Assura Ibarra


Tank: FTR 1000
Reported Date: 04/13/2024
Accomplished Date: 04/18/2024

Status: CLOSED

Issue: Loosed Tank


Investigation: due to the dent formation on
the groove lines causing to adjust the tanks
size to shrink.
Corrective Action: Tank Replacement
QUALITY ISSUES MAY
350

300
300 MAY 2024
Total SO Delivered: 300 Units
Total CFR Received: 5 Reports
250
Status: CLOSED
Percentage: 1.7% PASSED
200

Target: ​
150
• Reduce customer complaints due
100
to quality issues to 5% ​
• Zero customer claims/Returned items​
50

5
0
Series1

NC Delivered
QUALITY ISSUES MAY

CFR Control No.: 000117

Customer Name: Virgillio Otacan


Tank: FTH 2000L
Reported Date: 05/07/2024
Accomplished Date: 05/14/2024

Status: CLOSED

Issue: Leaking
Investigation: due to the small hole which
was causing to leak
Corrective Action: Devcon application and
Silicone sealant repair on site.
QUALITY ISSUES MAY

CFR Control No.: 000119

Customer Name: Jeanica Hydraulic


Trading
Tank: FTR 6000L
Reported Date: 05/24/2024
Accomplished Date: 05/25/2024

Status: CLOSED

Issue: Leaking
Investigation: Upon investigation on site, it
was found out that the leak was due to the
loose fittings
Corrective Action: Tightening of Fitting
QUALITY ISSUES MAY

CFR Control No.: 0043

Customer Name: KIMBO


CONSTRUCTION
Tank: FTH 775
Reported Date: 05/18/2024
Accomplished Date: 05/21/2024

Status: CLOSED

Issue: Leaking
Investigation: Upon investigation on site, it
was found out that the leak was due to poor
application of Silicone Sealant
Corrective Action: Re application of
silicone
QUALITY ISSUES MAY

CFR Control No.: 0041

Customer Name: CITI HARDWARE


OZAMIZ
Tank: FTR 2000L
Reported Date: 05/16/2024
Accomplished Date: 05/23/2024

Status: CLOSED

Issue: Leaking
Investigation: Upon investigation on site, it
was found out that the leak was due to poor
application of silicone sealant
Corrective Action: Re-application of
silicone
PRODUCT QUALLITY 1st QTR vs. 2nd QTR
1st QTR 2nd QTR

25
13

20

15

10 9

5
1
2 2
1
0
0 0
0
Dent Scratch LEAK Wrong Dimension Rust

Conclusion, the issue of leakage in stainless steel tanks is a significant and frequent
challenge that our plant must address. The integrity of the tanks is paramount, as leaks can
lead to product loss, environmental hazards, and potential safety risks. It is crucial for the
plant to implement stringent quality control measures, adopt advanced manufacturing
technologies, and conduct regular inspections to mitigate this problem. Ensuring the
production of leak-proof tanks is not only essential for maintaining the plant's reputation
but also for upholding industry standards and customer trust.
HYDROTESTING QUALITY ISSUES MAY
Hydrotesting of SS tank for 3000L Below

It will affect the production lead time,


but it will increase our product quality
assurance and lessen the cost of repair.

For 3200L and above, advise the client,


sales dept, dealers etc. to initiate
testing upon installation and inform the
QHS dept, for any issues during the
testing period.
HYDROTESTING QUALITY ISSUES MAY
Count of Tank Model
16

14
14

12

10

6
6
5 5

4
3
2 2 2
2

0
LEAKING PASSED PASSED LEAKING PASSED LEAKING PASSED PASSED
FTR 1000L FTR 1200L FTR 2000L FTR 500L FTR 775L
SUGGESTION:
QUALITY ISSUES MAY
• Adequate space and facility for
hydrotesting
• Hiring of Additional QC/safety officer
with skillset

Questions?

THANK YOU
QUALITY ISSUES MAY

PROJECT
MONITORING
QUALITY ISSUES MAY
AMG CORP GENERAL SANTOS CITY
QUALITY ISSUES MAY

Manpower 4 (3 welders and 1 helper)


Leadtime 28 days
QUALITY ISSUES MAY
PRINCETON HOTEL PAGADIAN QUALITY ISSUES MAY

Manpower 4 (3 welders and 1 helper)


Leadtime 21 days
QUALITY ISSUES MAY
DAPA PUBLIC MARKET QUALITY ISSUES MAY

Manpower 4 (3 welders and 1 helper)


Leadtime 22 days
QUALITY ISSUES MAY
QUALITY ISSUES MAY

Questions?

THANK YOU

You might also like