Advanced Control System
Advanced Control System
CONTROL SYSTEM
P R O C E S S C O N T R O L A N D I N S T R U M E N TAT I O N
BY
A N G E LY N N
ANGELENA
YUNUS
L O R E T TA
VIMALAN
INTRODUCTION
A thermostat
Used to control controlling a heater
ON OFF CONTROLLERS
W
h
e
n
it
cr
o
Hse
te
nh
Tpd
ec
h urest
le
e vt
oel,
o tefc
ho
u ef
t o
u
p p
t
u u
t,
t vt
ca hal
ve
u pe
or
seof
tces
chv
h bs
eari
a yle
stea
n g
m
g na
isa
e gstar
aic
i nh
a
n nf
ug
li
p yn
g
r o
pb
o ue
nt
ces i
v nt
o
ari gv
re
b iers
vd
le. eirct
1o
0n
0.
%
o
u
t
p
u
t.
WATER TANK USING TEMPERATURE
CONTROL
Steam is admitted through the coil but again, reaching its trough of undershoot at point E.
The difference between the peak and the trough is known as the operating differential.
The switching differential of the thermostat depends on the type of thermostat used.
ON OFF CONTROLLER
If the controlled condition is outside the bandwidth, the output If the controlled condition is within the bandwidth, the controller
signal from the controller is either fully on or fully off, acting as output is turned on and off relative to the deviation between the
an on/off device. value of the controlled condition and the set point.
When transformer runs with such a load, the temperature of the electrical power transformer rises beyond the preset value .
As the cooling fans run, the forced air decreases the temperature of the transformer.
When the temperature (process variable) comes down below a preset value, the control switch of fans trip and fans stop supplying forced air to the transformer.
Again when during rising, the temperature crosses the preset value, the fans again start rotating to cool down the transformer.
FAN CONTROLLING SCHEME OF TRANSFORMER
COOLING SYSTEM.
• There is always a non zero time delay for closing and opening action of controller elements.
• This time delay is known as dead time.
• Actual response curve differs from the above shown ideal response curve.
ADVANTAGES & DISADVANTAGES
Advantages
•It is simple and very low cost.
•This is why it is frequently found on domestic type
applications such as central heating boilers and heater fans.
Disadvantage
•The operating differential might fall outside the control
tolerance required by the process.
FEED-FORWARD
CONTROL SYSTEM
NAME : ANGELENA RANI FRANCIS
ID : 1000032
Is a mechanism in a system that monitors The control variable adjustment is not error-
performance inputs rather than its outputs. based.
Block diagram of feed-forward system
ADVANTAGES
Takes corrective action before
the process is upset.
DISADVANTAGES
Incapable of
Takes no For frequent
Theoretically
and
correcting a
corrective actionsevere
not capable of
deviation from
until a deviation
disturbances,
achieving
set point at the
in the controlled
process may“perfect
not
time of its
variable occurs.settle out.
control.”
detection.
APPLICATIONS
• HEAT EXCHANGER
APPLICATIONS
• SIMPLE BINARY DISTILLATION COLUMN
APPLICATIONS
• HOME FURNACE
EXAMPLE QUESTION
• CONTINUOS STIRRED TANK REACTOR(CSTR)
RATIO
CONTROL
NAME : MUHAMMAD YUNUS
ID :
WHAT IS RATIO CONTROL?
ased on product
tions, feedstock
y, the actions of
r it may simply
least willing to
rmal operation.
s in this article
note that other
uch as variable
rs may also be
plementations.
RELAYS IN THE RATIO ARCHITECTURE
A ratio set point value is entered into the FCC, along with tuning
parameters and other values required for any controller implementation.
RATIO RELAY OR FLOW FRACTION CONTROLLER
C
o
n
qpseIt
u
er
notly,
vt
hTie
uhd
osees
T hnxt
fe
etracl
h ody
rati
relarati
e ohy
he
c m
h
um
tsaas
h d
vpf
ealtie
o ualier
vnnta
gealcti
ice uo(
onre
o dialt
dnyisa
f vas
arelt
yhnta
u gise
dnerati
si oe
peta
n nreal
dydi
nil
g gyc
o
a nm
bt
acesi
hlei
rela pnae
pare
y dplicat
m
o
netr.I
w)t
hofit
o qhref
uoa
r nires
gnre
qga
a uhile-
giresa
gnher
n plerat
vuleel
ovt
faelsi
F uon
hopgle-f
t
F orizater
uo
nm
C opbef
ist
isa nuorea
ct
hac
p ngo
a
dne
ractil nocaesttr
m
bolerase
dm
ater.
dduaisc
e
tjse
oud
ts.
hae
brati
oo
v
m
ultie.
p
lier.
ADAPTIVE
CONTROLLER
N A M E : M A R I A L O R E T TA L AW R E N C E
ID : 1000339
WHAT IS AN ADAPTIVE CONTROLLER?
Adaptive control is the control method utilized by a For instance, as an airplane flies, its mass will
controller which must adjust to a controlled system gradually diminish as a consequence of fuel
with parameters which change, or are at first utilization; a control law is required that adjusts to
uncertain. such evolving conditions.
Algorithmic Program Control
ADAPTIVE CONTROL IN PHOSPHATE
INDUSTRY
Autotuner:
• An autotuner is often a PID controller where the control parameters are automatically tuned only at
commissioning. I.e. a sequence of step responses or a relay type of control in order to find an appropriate
parameter setting.
TYPES OF CONTROLLERS
Others:
• Aeroplanes Distillation Columns
• Ship Steering
In such a control system, the output of the primary controller determines the set point for
the secondary controller.
The output of the secondary controller is used to adjust the control variable.
Generally, the secondary controller changes quickly while the primary controller changes
slowly.
Once cascade control is implemented, disturbances from rapid changes of the secondary
controller will not affect the primary controller. [ Extracted from : Wikipedia ]
In a double loop cascade system, the action of the secondary loop
on the process should be faster than that of the primary loop.
This ensures that the changes made by the primary output will be
reflected quickly in the process and observed when the primary
control variable is next measured.
There must Response
be a clear The period of the
relationship secondary primary loop The major
The primary
between the loop must has to be at disturbance
loop should
measured have least 4 times to the system
be able to
variables of influence larger than should act in
have a large
the primary over the the response the primary
gain, Kc.
and primary period of the loop.
secondary loop. secondary
loops. loop.
Setpoint - temperature desired for the water in the tank
Primary controller (master) - measures water temperature in the tank and asks the secondary controller for more or less
heat
Secondary controller (slave) - measures and maintains steam flow rate directly
Outer loop disturbances - fluctuations in the tank temperature due to uncontrolled ambient conditions, especially
fluctuations in the inflow temperature
Secondary process variable - steam flow rate
The secondary
controller can Closing the control
correct the loop around the
disturbance affecting secondary part of the
the secondary process reduces the
variable , before a phase lag seen by the
pronounced primary controller,
influence is felt by resulting in increased
the secondary speed of response
variable.
DISADVANTAGES
Cascade control
systems are also
The extra sensor
more complex
and controller
than single-
tend to increase
measurement
the overall
controllers,
equipment costs.
requiring twice as
much tuning.
REFERENCES
• K. S. Narendra and A. M. Annaswamy, Stable Adaptive Systems. Englewood Cliffs, NJ: Prentice Hall,
1989; Dover Publications, 2004.
• S. Sastry and M. Bodson, Adaptive Control: Stability, Convergence and Robustness. Prentice Hall, 1989.
• http://www.hindawi.com/journals/jcse/2012/827353/
• http://www.pages.drexel.edu/~kws23/tutorials/MRAC/MRAC.html
• https://www.linkedin.com/pulse/fundamentals-cascade-control-hamzeh-ahmadi
• https://controls.engin.umich.edu/wiki/index.php/CascadeControl
• http://
www.controleng.com/single-article/fundamentals-of-cascade-control/bcedad6518aec409f583ba6bc9b728
54.html
• http://newton.ex.ac.uk/teaching/CDHW/Feedback/ControlTypes.html#OnOffCtl
• https://www.quora.com/What-is-a-bang-bang-controller
• http://newton.ex.ac.uk/teaching/CDHW/Feedback/Technical-Info.html
THANK YOU