Parking Brake Abnormal

HD 785-7

Nama : Faisal Said


NRP : 83105025
Site : FMC Bendili
Jabatan : Mekanik
Grade : 4B

PT. United Tractors, Tbk


Site FMC Bendili - Office Soulmate, Plant 2 PAMA KPCS
Telp/Voice : 3210 (Ext 105)
UNIT DATA

Unit Model / SN : HD785-7 / 30164


Unit Number : DT4363
Engine Model / SN : SAA12V140E-3 / 505844
HM Unit : 25560
Customer Name : PT. Pama Persada Nusantara
Machine Location : W/S Soulmate (Site Bedili)
Trouble Date : 06 Juli 2015
Corrected Date : 06 Juli 2015
SN
HM :: 30164
25560
Trouble Shooting
Symptom : Parking brake abnormal
Parking brake caution lamp stay on when parking brake switch OFF

Possibilities causes:
1. Parking brake switch 6. Oil level
2. Parking brake relay 7. Brake pump
3. Fuse (BT 3 NO 8) 8. ACC valve
4. Pressure switch 9. Solenoid P brake
5. Wiring 10. P brake valve
Possible Cause

• Defective parking brake switch.


• Disconnection in wiring harness .
Electrical • Defective parking brake relay.
failure • Defective parking brake presssure
switch.
• Defective solenoid parking brake.
Parking • Fuse blown (BT3 No 8)
Brake
Abnormal

• Oil brake low level.


Hydraulic / • Brake pump low pressure.
Mechanical • Seal piston parking brake leak.
failure • Defective parking brake valve.

PT.United Tractors, Tbk – Site Bendili


Diagnostic & Data
Diagnostic : Data:
Pengetesan fungsi parking brake.
•Running engine sampai pressure brake tercapai. •Pressure tercapai (lampu OFF)
•Release parking brake kemudian coba bergerak maju atau mundur. •Bisa maju mundur ( lampu ON)
•Aktifkan parking brake kemudian coba bergerak maju atau mundur. •Tidak bisa maju mundur

PT.United Tractors, Tbk – Site Bendili


Diagnostic & Data
Diagnostic : Data:

No Item STD Actual


1 Check Voltage pada pin 1 reay parking brake (parking brake release) 24 V 0V
2 Check resistance pressure switch ketika parking brake release Max 1Ω OL
3 Check resistance R03 (1) - PSW (2) Max 1Ω 1Ω
4 Check resistance R03 (1) - groud Min 1MΩ 46 MΩ

2 4

PT.United Tractors, Tbk – Site Bendili


Analysis & Suspected Cause
Analysis :

No Item STD Actual


1 Check Voltage pada pin 1 reay parking brake (parking brake release) 24 V 0V
2 Check resistance pressure switch ketika parking brake release Max 1Ω OL
3 Check resistance R03 (1) - PSW (2) Max 1Ω 1Ω
4 Check resistance R03 (1) - groud Min 1MΩ 46 MΩ

Analysis data:
Kesimpulan dari data di atas adalah terjadi kerusakan pada pressure switch
parking brake (jamed open), karena resistance pressure switch tetap tidak
terbaca ketika parking brake direlease.

Suspected Cause :
Pressure Switch Parking Brake P/N 421-43-32912 (Jamed Open)

PT.United Tractors, Tbk – Site Bendili


Conclusion
Kesimpulan
Parking brake abnormal ( caution lamp tetap menyala ketika switch parkin brake OFF),
disebabkan oleh rusaknya parking brake pressure switch (jamed open). Akibatnya, power
24 volt dari fuse BT3 NO 8 yang berfungsi sebagai trigger tidak sampai ke relay R03
ketika parking brake release; sehingga switch pada R03 tetap ON dan kontroller retarder
tetap membaca parking brake aktif.

PT.United Tractors, Tbk – Site Bendili


Action
Activities:
•Replace pressure switch parking brake.
•Test function parking brake.
•Final Check.

PT.United Tractors, Tbk – Site Bendili


Terima Kasih

PT.United Tractors, Tbk – Site Bendili


Lampiran

PT.United Tractors, Tbk – Site Bendili


ON UNIT TROUBLE SHOOTING FIELD ACTIVITIES
STEP 1 : STEP 2 : STEP 3 :
TROUBLE STEP 4 : STEP 5 :
POSSIBILITIES OBSERVE &
SHOOTING DATA ANALYSIS
CAUSES DIAGNOSTIC

REQUIREMENT REQUIREMENT
- CHARM, PATIENT, CAREFUL AND OPEN MIND
- TECHNICAL KNOWLEDGE
+ - COMMUNICATION SKILL
ACTIVITIES ACTIVITIES
1 COLLECT 1 Compare the data's with the
* Measurements results proper standard
REFFERENSI & TOOLS ACTIVITIES *Testing results 2 Discussion with others for
1 Shop Manual, PK2, QA form 1 OBSERVE * Discussion with customer proper analysis , Superior, BI,
2 Troubleshooting Chart * Operation Condition * Photos As references Mechanics, TO etc
3 Parts & Service News * Maintenance system
4 Tools Measurement * Parts Usage
5 Digital Camera * Load Condition
2 CHECK AND TESTED
ACTIVITIES * Unit Performance
1 Do the step of TS by the easier way 3 DISKUSI with Customer
2 Indicate the parts, Components & circuit which * OPERATOR, to collect daily
which got abnormality, ie. Break, Not Standard .. symptom
3 Take the photos as references * Mechanics, to collect repair
4 Record the results of measurement or testing historical

STEP 8 : STEP 7 : STEP 6 :


ACTION TO IMPROVEMENT CONCLUSION SUSPECTED CAUSE

ACTIVITIES ACTIVITIES ACTIVITIES


REPORTING SYSTEM 1.Repair the problem by, 1 Ensure the suspicion problem by, 1 State the suspicion of the problem
• Adjustments * Adjustments 2 Indicate abnormality by criteria
PROVIDE COMPREHENSIVE • Replace parts or repair parts * Replace by temporary normal parts * the abnormality is the main problem
REPORT TO SHARE OTHERS • Modification from others or
• Share to customer the problem * Temporary modification * The abnormality is only the effect
and problem solution to prevent 2 BE CONCLUDED FROM ALL

You might also like