Lecture 9
Lecture 9
Design
Prof. Dr. Khair Al-Deen Bsisu
Lecture 9
ONE-WAY
Ribbed SLAB
One-Way Ribbed Slabs
Since resistance of concrete in tension is too small compared with
that in compression, concrete in the tension zone may be
gathered in regularly spaced ribs cast monolithically with topping
slab on top of these ribs.
Hollow blocks made of lightweight concrete or other materials are
arranged between the ribs or the voids between ribs are left out
without any filling material.
There are two main types of ribbed floors (a) hollow block floors and
(b) moulded floors as shown in Figure. Each type of floor consists of
number of reinforced concrete ribs spanning in the short directions
supporting a thin topping slab above.
Ribbed slabs can be used in one-way and two-way edge supported
slabs.
Either drop or hidden beams can be used to support these slabs
depending on the span.
If the ribs are provided in one direction only, the slab is
classified as being one-way, regardless of the ratio of
longer to shorter panel dimensions.
Key components
Minimum dimensions:
According to ACI Code 8.11.2, ribs are not to be less than 10 cm in
width, and a depth of not more than 3.5 times the minimum web
width. Clear spacing between ribs is not to exceed 75.0 cm as
specified by ACI Code 8.11.3.
Loads:
The load on ribs consists of dead and live loads. The dead load
includes own weight of the slab, weight of the surface finish, and
equivalent partition load. The live load is dependant on the
intended use of the building.
Arrangement of ribs: (a) ribs are arranged in the shorter
direction; (b) ribs are arranged in the longer direction
The designer has to make up his mind regarding the option he
prefers.
Shear strength:
According to ACI Code 8.11.8, shear strength provided by rib
concrete Vc may be taken 10 % greater than those for beams. It is
permitted to increase shear strength using shear reinforcement or
by widening the ends of ribs.
Although shear reinforcement is not often required, it is
recommended to use 4φ 6 mm stirrups per meter run,
Flexural strength:
Ribs are designed as rectangular beams in the regions of
negative moment at the supports and as T-shaped beams in
the regions of positive moments between the supports.
Effective flange width be is taken as half the distance between
ribs, center-to-center.
:c. Hollow blocks
Hollow blocks are made of lightweight concrete or other
lightweight materials. They are commercially available in
standard sizes and shapes.
The most common concrete hollow block sizes are 40 × 25
cm in plan and heights of 14, 17, 20, and 24 cm.
Minimum Thickness
: Solution
Ribbed slab
:The direction of ribs is chosen .1