X1 X1
STM-1 AUG AU VC.4
155 Mb/s X3
TUG-3
TUG-3
TUG-3
X7
TUG-2
TUG-2
TUG-2
TUG-2
TUG-2
TUG-2
TUG-2
X3
2 Mb/s
DIP
TU-12
TU-12 VC-12
VC-12 C-12
C-12
- Optical interface, S-1.1 1310 nm TU-12 VC-12 C-12
- Electrical interface, 155.52 MHz CMI
EN/FAD 109 0015
LOT-w
LOT-w
LOT-w
LOT-w MS-1
LOT-w
LOT-w HOT-w
HOT-w Working
LOT-w
LOT-w
GS
GS
MS-2
HOT-p
HOT-p Protection
LOT-p
LOT-p
ET155
HOT Higher Order Termination
LOT Lower Order Termination
EN/FAD 109 0015
P Protection
W Working
HOT LOT w
LOT std by
EN/FAD 109 0015
RP 4 dummy
420 mm
2000-03-23 5 Confidential ETO/S/CZ K.P. Laulo
ET 155 - HOT & LOT
EN/FAD 109 0015
Optical or electrical
DL-34 interface STM-1 interface
MS-1
ET155-1-w
ET155-1-w Working
GS
GS
AUG link (back plane)
MS-2
ET155-1-p
ET155-1-p Protection
ET155-1
EN/FAD 109 0015
AUG
W P
AUG
W P
AUG
W AUG P
W P
EN/FAD 109 0015
SCB-RP
SCB-RP
XDB
XDB
2000-03-23 9 Confidential ETO/S/CZ K.P. Laulo
ET155 SW Architecture
Operator
“User” ISUP TUP Interface
RPADM APZ
RPADP
RPADS ETDIF#1 ETDIF#2 ETDIF#3
RPADC DIPMC
DIPST
OMS DIPAMC
EXDA
EXDAP
SNTDA DIPHID
SNTMC
TRAN1
PSEMC PSNMC
ET SDIPST
NS GSS SDIPMC
NSC SDIPQ
GSM
GSM2
SNEAL SDIPAMC
SNEC SDIPHID
SNEFD
SNEFI
SNETR GS
EN/FAD 109 0015
TSM ETC155
GSSNTM 155 Mb/s SDH interface
2014 SDIP
VC-12
1 DIP
0 Device
VC-4
ETC
8500 mm
GSS
CP & IO
4600 mm
DDF/ODF
EN/FAD 109 0015
ST 7 &
misc
4200 mm 4200 mm
2000-03-23 12 Confidential ETO/S/CZ K.P. Laulo
DIP / SDIP Functions
• Administration
• Definition / un-definition of DIP & SDIP
• Setting initial data
• Printing of Connection Data, Initial Data, State etc..
• Partly Equipped supported
• Fault Supervision
• Handling of Transmission failures
• Quality Supervision
EN/FAD 109 0015
• Performance Monitoring
Protection
Switch
Alarm
Alarm Ceasing
Fault
OK
t
Fault Filtering Time Cease Filtering Time
- typical 2.5 seconds - typical 10 seconds
• Alarm correlation (i.e. alarm issued for the most serious fault)
2000-03-23 14 Confidential ETO/S/CZ K.P. Laulo
Quality Supervision (Performance Monitoring)
Set Threshold
Reset Threshold
15 min. interval
Unacceptable Performance
EN/FAD 109 0015
Set Threshold
15-min. registers:
Measurements
24-hour registers:
Measurements
Current Data Recent Data
1 43 3 5 6 0 1 43 3 5 6 0
EN/FAD 109 0015
2 0 5 2 0 1 2 0 5 2 0 1
0 9 12 0 8 2 0 9 12 0 8 2
ES / SES
2000-03-23 18 Confidential ETO/S/CZ K.P. Laulo
Quality Supervision, additional information
Failed
MS-0 MS-0
• Optional feature
2000-03-23 20 Confidential ETO/S/CZ K.P. Laulo
DL-3
ET155
• SNT Administration
• Connection / Disconnection / State Printouts etc..
• Downloading of DP software
• no traffic disturbances
EN/FAD 109 0015
• Local Exchanges
• Transit Exchanges
• International Gateways
• MSCs (GSM and D-AMPS)
• BSCs (GSM)
• ...
EN/FAD 109 0015