Performance Check

Make performance check on the MFD equipment regularly and if any problem is found, investigate it
immediately. Pay special attention to the high voltage sections in inspection and take full care that
no trouble is caused by any error or carelessness in measurement. Take note of the results of
inspection, which can be used effectively in the next inspection work.
Carry out performance check on the items listed in the check list below.

Check List
Equipment Item to be checked Criteria

Display unit Screen image Can be correctly controlled


Screen operation
Cleaning the DVD drive Cleaning the lens of the DVD
drive
1.Starting Selftest functions

1)Click on the [Menu] button on the left Tool Bar.


The menu is displayed.
2)Click on the [Maintenance] - [Selftest] button on the menu.
The [Selftest] dialog box appears.

Disclosure button

Selftest functions

The Selftest functions are displayed in the left pane. Click on the disclosure button to hide the left pain.
3)Click on a Selftest function to be executed.
The execution dialog of the selected Selftest function is displayed.
2.Confirming the screen status [Monitor Test]

Confirm the screen status.


1)Click on the [Menu] button on the left Tool Bar.
The menu is displayed.
2)Click on the [Maintenance] - [Selftest] - [Monitor Test] button on the menu.
When the color or pattern of the dialog is clicked on, the color or pattern is displayed on the screen.
Check the screen status with the display status.

19

To reset the display, click the button again.


Pattern list

Pattern button name Display


All Red

The entire screen is displayed in red.


All Green

The entire screen is displayed in green.


All Blue

The entire screen is displayed in blue.


All White

The entire screen is displayed in white.

Pattern4

Displays the pattern for checking the communication


quality for VDR.
Pattern button name Display
Pattern5

Displays the pattern for checking the communication


quality for VDR.

Pattern6

Displays the pattern for checking the communication


quality for VDR.

Gray Scale

Displays the grey scale pattern for checking the19


monitor brightness adjustment.
Grey scale patterns can be identified with brightness
in day/night mode. By adjusting the monitor
brightness to facilitate identification of grey scale
patterns, the optimum brightness can be set. The
brightness in night mode can also be adjusted in the
same way.
Use the Day/Night button on the right Tool Bar for
switching between the day and night mode.
Pattern button name Display
S-57 Color Pattern

A color test pattern of the S57 chart is displayed.


By identifying the color pattern, the S57 chart
display status can be verified. A color pattern can
be displayed in Day/Night mode.
Use the Day/Night button on the right Tool Bar for
switching between the day and night mode.

ARCS Color Pattern The [ARCS Color Pattern] dialog is displayed.

A color test pattern of the ARCS chart is displayed.


By identifying the color pattern, the ARCS chart
display status can be verified. A color pattern can be
displayed in Day/Night mode.
Use the Day/Night button on the right Tool Bar for
switching between the day and night mode.

Section 19 Maintenance & Inspection 19-26


3.Confirming the operation of the operation unit [Key Test]
Confirm the operation of the keys of the operation unit.
1)Click on the [Menu] button on the left Tool Bar.
The menu is displayed.
2)Click on the [Maintenance] - [Selftest] - [Key Test] button on the menu.
3)Click on the [Key Test Start] button.

19
Key Test window is displayed.

4)Operate the keys, buttons and dials in the operation unit.


If the performance of the operation unit is normal, the colors of the keys, buttons and dials are changed.
5)Click on the [Key Test Stop] button after the operation check.
Returns to the [Selftest] dialog box.
4.Confirming the alert sound [Sound Test]
Confirm the alert sound.
1 Click on the [Menu] button on the left Tool Bar.
The menu is displayed.
2 Click on the [Maintenance] - [Selftest] - [Sound Test] button on the menu.
3 Click on the [Sound Test Start] button.
A sound test starts. All the available beep sound volumes can be tested by increasing the level from 0.
5.Testing the brightness of LED [Light Test]
Test the brightness of the LED of the operation unit.
1)Click on the [Menu] button on the left Tool Bar.
The menu is displayed.
2)Click on the [Maintenance] - [Selftest] - [Light Test] button on the menu.
3)Click on the [Light Test Start] button.
A LED brightness test starts. All the available brightness levels can be tested by increasing the level from 0.

19
6.Checking the memory [Memory Check]
Check the memory.
1)Click on the [Menu] button on the left Tool Bar.
The menu is displayed.
2)Click on the [Maintenance] - [Selftest] - [Memory Check] button on the menu.
3)Click on the [Memory Check Start] button.
Memory checking starts and the checking result is displayed on the [Result] list.

On JAN-5203, the SSD Test No.1 to No.4 are NG. It is no problem.


In the SSD Test No.1 to No.4, data drive SSD is checked.
RPS has not SSD as data drive.
7.Cleaning the lens of the DVD drive
1)Insert the supplied lens cleaner CD into the DVD drive.
2)Click on the [Menu] button on the left Tool Bar.
The menu is displayed.
3)Click [Maintenance] - [Selftest] - [DVD Cleaning] from the menu.
Cleaning automatically starts.
The following dialog box appears during cleaning:

19
4)When the cleaning completion dialog box appears, click on the [OK] button.

Remove the supplied lens cleaner CD.

Note
It is recommended that the DVD drive is cleaned at least once a month. If the lens becomes dirty, it
may not be possible to read data from a CD/DVD, or else it may not be possible to install a chart or an update.
When reading the lens cleaner CD fails, an error dialog box appears.