0% found this document useful (0 votes)
433 views41 pages

Valmet DNA - Overview

Valmet

Uploaded by

venkyjajula55
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
433 views41 pages

Valmet DNA - Overview

Valmet

Uploaded by

venkyjajula55
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 41

Valmet DNA 2015

OVERVIEW
By
RAKHI.L.MOHAN
MANAGER
CE-ENGG-BOP
Upgradeability with innovative evolution

1979 1988 1996 2000 2006 2011 2015

Damatic Damatic XD Damatic XDi metsoDNA metsoDNA CR Metso DNA Valmet DNA
”Classic”

 Connectability  User friendly


 Upgradeability  Flexible
 Openness  Reliable
 Same platform for all applications  Long experience of
developing control systems

2 © Valmet |
Valmet DNA architecture
Control room Windows Server:
Engineering
¯

Windows Server:
Windows PC’s Information management

Redundant Process controllers Interfaces to


controllers third party systems

Field buses

IO units
Variable speed drives

Safety system
Motors
Field devices 4-20 mA

3 © Valmet |
Valmet DNA scalability and architecture

 Valmet DNA is truly scalable system starting from a tiny system and
extending to large system
 The communication of Valmet DNA is using tag names. Tag names
are unique through out the whole system
 Valmet DNA can access and work via internet or modem line if
needed. Future integration of several mills working like one single
installation is possible
 Valmet DNA has good capabilities for remote accessibility.
 Valmet DNA supports full redundancy down to I/o level

4 © Valmet |
Valmet DNA redundancy
Backup Power Supply for
- control node cabinets and rack I/O’s
Redundant hard Optional power backup for
disks and backup - control room devices and
tape device servers

Information Server Engineering Server Operator Interface

Alarm Processing

Redundant control room bus and process bus


Back-up (BU) PCS PCS PCS GTW-LIS GTW-LIS
Redundant
Redundant power supplies and
hard disk
Interface controller
Redundant M120 I/O units
Redundant process
controller PLC PLC

Redundant
Redundant PLC
PROFIBUS DP interface
Field Bus
devices
Redundant
I/O power
supply
per rack.

5 © Valmet |
Valmet DNA user interface and history data

 Valmet DNA has integrated user interface for operators, flexibility to


use known operating environments like windows, Internet explorer
tools, Excel, etc.
 Valmet DNA user interface provides good integration to history,
reporting and analyze tools
 Valmet DNA history (Info) provides advanced tools for history trending,
analyzing and reporting
 Valmet DNA has advanced integrated documentation , administration
and diagnostics/troubleshooting tools
– E.g. troubleshooting: “time machine” feature in operator graphic window

6 © Valmet |
Valmet DNA Operate – efficient problem solving
Time machine feature for any picture
Switch to history mode
History mode indication
 For collected tags
– History replay from any picture
– Drag ’n Drop to analysis tools

Select time in history and replay

7 © Valmet |
DNA Report Tracer – trend and analyse tool

8 © Valmet |
DNA Report Tracer

Events now connected


together with the
corresponding trend row

Usability enhancements in
the legend area enable
flexible online configuration

9 © Valmet |
Alarms & Events Management
History mode in event browser

10 © Valmet |
ACN MR Controller

 ACN MR is Modular Rail mounted controller


 ACN MR is a multifunctional controller and member of ACN controller
family. ACN MR controller is used in centralized, distributed and
embedded applications
 ACN MR can be also used in standalone applications with or without
connection Valmet DNA system
 ACN MR is application and communication compatible with other
Valmet DNA controllers
 ACN MR controller can be redundant

11 Date/Title/Author © Valmet |
Valmet DNA process controllers

 Valmet DNA ACN controllers can run complex control algorithms for
e.g. predictive and multivariable controls. With competitor system
algorithms are typically implemented in separate Windows
workstation.
 Valmet DNA ACNs are using multitasking operating systems, so it’s
possible download and run applications in parallel with real time
control functions.
 All Valmet DNA ACN controllers are using the same application
language and tools
 As an option there is conformal coating available for the controllers

12 © Valmet |
ACN process controller family
Reliable Controllers with Flexible Field Options

A complete controller family for process


control applications and external interfaces.
– ACN RT large expandable controller ACN RT
- all field buses supported
- centralized installations
• ACN CS compact controller
- all field buses supported ACN CS
- field and centralized installations
• ACN MR compact controller
- all field buses supported
ACN MR ACN SR1
- field and centralized installations
• ACN SR1 small rail mounted controller
- with ACN I/O
- for embedded field installations

13 © Valmet |
Valmet DNA I/O units

 All I/O units can be changed during the operation (hot swap)
 All digital inputs units have time stamping feature. Resolution is 1 ms
or 2 ms depending on the unit. There is no limit for the number of
“sequence-of-event” signals
 As an option there is conformal coating available for the units.
 Valmet DNA I/O units have electronic over current protection feature.
There is no need to use fuses in field connections.
The exception are digital output units with mechanical- or solid state
relay

14 © Valmet |
ACN I/O product family
Key features

 ACN I/O is modern I/O family which combines the best features
of centralized and distributed I/O in one compact design
 Simplifies system design, cabinet assembly and
commissioning
 Best performance and features
– Speed - fast controls down to 20 ms
– Extensive diagnostics
– High accuracy of AI and AO
– 1 ms sequence of events (SOE)
– Hot swapping
– HART embedded
– Channel specific isolation
– 115-240 VAC DI and DO units
– G3 environmental specification with optional lacquered
units
– Operating temperature 0...+70 °c
– High packing density
 Connected with Ethernet to ACN controller

15 © Valmet |
ACN I/O product series

 Two series of ACN I/O: ACN M80 I/O


– M80 for ordinary process control and  DIN-Rail mounting
monitoring. • Max. 16 modules per
– M120 when high isolation voltage is group
required and for vibration sensors. • Field signals directly
 1 millisecond accuracy for digital connected or to
terminal board via flat-
(on/off) alarms throughout the cable to I/O module.
system!
 Easy maintenance by: ACN M120 I/O
– Extensive built-in diagnostics. • DIN-Rail mounting
– Simulator and status window in • Max. 16 modules per
operator station. group
– “Hot swapping” module change. • Field connection via
cable and connector
module

16 © Valmet |
ACN I/O M120 series
I/O units for demanding industrial applications

 All M120 series I/O units have 1500 VAC isolation voltage between
logic part and I/O channels (ref IEC60664-1: Table 2 and 4 + Annex A &
IEC 61010-1 table D.4)
 Analog I/O units and some digital units have isolation between I/O
channels 1500 VAC – 2200 VAC depending on the unit
 M120 I/O digital units can be used for high DC/AC line voltages without
external relays
 M120 I/O units uses the same power supply and controller units than
other ACN I/O units.
 M120 I/O units are mounted on MBI8 mounting board (8 I/O units).

17 © Valmet |
ACN I/O M120 series units

Analog units, 1500 VAC Digital units Other units, 1500 VAC
isolation between channels isolation between channels
AII8C DII8P24, DII8P48 FII4V
- 8 analog input channels -8 digital input channels - 4 channel frequency inputs
- voltage supply to transmitters - Self-powered short-circuit protected,opto-isolated, - 0 - 400 kHz
- 0/4 - 20 mA PNP input (24 or 48 VDC) - 24V P-type pulse inputs
- I/O channels have common ground
AII8CN TII4W3, TII4W4
- 8 analog input channels DII4U120, DII4U240 - 4 channel temperature input unit for RTD (PT-10,
- no voltage supply to transmitters -4 digital input channels PT-100,PT-1000)
- 0/4 - 20 mA - Potential free full wave rectified digital inputs for 120 - 3 wire or 4 wire connection
or 240 VAC inputs
AII8V - 2200 VAC isolation between channels TCI8
- 8 analog input channels - 8 channel temperature input unit for
DII8U120, DII8U240 thermocouples
- 0/1 - 5 V -8 digital input channels - 2 wire connection
AII4H - Potential free full wave rectified digital inputs for 120 -Thermocouples supported : J, K, T, E, S, R, B, N,
- 4 analog input channels or 240 VAC inputs G, C, D, Platinel II and EMF
- 0/4 - 20 mA HART - 1500 VAC isolation between the unit and the system
Vibration monitoring units
AOI4C DII8U48, DII4U125 - Vibration and triggering measurement units
- 4 analog output channels - 8/4 digital input channels
- 0/4 - 20 mA - Potential free/polarity free digital inputs for 48/125 Fast control units
VDC inputs - Servo control, valve position input
AOI4H - 2200 VAC isolation between channels
- 4 analog output channels DOI4RO
- 0/4 - 20 mA HART - 4 digital output channels
-Single pole, closing contact,polarity free 3.0-5.0 IBC, I/O Bus Controller
A//120-240 VAC or 0.3-5 A/ 24-125 VDC - Connects I/O group to ACN
- 2200 VAC isolation between channels - max. 32 I/O units / IBC controller

DOI8RO, DOI8IRO
- 8 digital output channels
-Single pole, closing contact,polarity free 1.0 A//120-
IPSP, I/O Power Supply
240 VAC or 0.3-3.0 A/ 24-125 VDC
- 1500 VAC isolation between the unit and the system - Power supply for I/O group
- For DOI8IRO: 2200 VAC isolation between channels - max. 32 I/O units / IPSP

18 © Valmet |
ACN I/O M120 units for vibration measurements

AIF8V AIF8T Isolation

-8 channels, 16 bits, -3 dB, 9.1 kHz, -8 channels, 16 bits, -3 dB, 9.1 kHz, - Field to system 1500 VAC
1500 VAC / 60 s, 50 μs (20 kHz) 1500 VAC / 60 s, 50 μs (20 kHz) - Between channels 1500 VAC

-Acceleration sensors - Rotation speed signals from the


synchronization sensors (for
-0…24 V voltage signals. example, RTS-226).
-4 mA constant current supply for The unit is equipped with a channel-
acceleration sensors specific current-limited operating
voltage supply for the transmitter.

19 © Valmet |
ACN I/O M120 units for turbine vibration
measurements and diagnostics

AIF4E AIF4V Isolation

Eddy current measurement for shaft Absolute vibration measurement - Field to system 1500 VAC
position or vibration measurement using accelerometers or - Between channels 1500 VAC
velomitors

- 4 input channels
- each channel configurable for - 4 input channels
both static and dynamic values, - each channel configurable for 2
- 2 calculated values per calculated values per
channel supported channel, rms or peak, vibration
- 100 ms update rate for protection acceleration or velocity
(API670) - 100 ms update rate for protection
- raw signal sample buffers and outputs (API670)
for external diagnostic applications - raw signal sample buffers for
- 4 output channels 4–20 mA, external diagnostic applications
any value to any output - 4 output channels 4–20 mA,
any value to any output

20 © Valmet |
Redundant ACN PCS and ACN I/O

 Redundancy improves the already high


availability of Valmet DNA
 Redundancy makes it possible to by-pass and
disconnect a failed part of the system
 Redundant ACN controllers can locate in
different rooms or buildings
 Redundancy for ACN RT, ACN CS and ACN
SR1 controllers
 Redundancy can be carried out in the
following steps
– redundant process network connection
(always)
– redundant process network and I/O field
bus connection
– redundant process network and redundant
PCS including redundant I/O field bus
– redundant ACN M120 I/O
21 © Valmet |
Redundant ACN I/O M120 units
New Key Features

 Redundancy for M120 I/O units


 Redundant I/O is used with redundant process controllers
 Redundant I/O’s can locate in the same or different cabinets
 Straightforward configuration of redundancy application

 I/O redundancy is used in applications where extremely high


availability is required

22 © Valmet |
Simulation of ACN I/O

 Simulation of ACN I/O is done with software. There are no


simulation switches in I/O units
 Simulation panel is activated from DNA Operate Operator Interface
 Versatile searching and sorting actions
 Simulation of one I/O channel or several I/O channels
 Event display for active simulated I/O channels

23 © Valmet |
Simulation display of ACN I/O

Order of columns can be Simulated I/O-value Simulation status Output read-back simulation status
defined in editor (blank with measurements)

Actual I/O-value

24 © Valmet |
Valmet DNA engineering

 Valmet DNA offer user friendly configuration tools. You can access
data by tag name, regardless of hardware or location .
 Valmet DNA allow centralized configuration from the operator or
engineering console in the control room. You can change
programming offline, and download without restarting the system
 Valmet DNA engineering has powerful tools for application generation
and mass modifications

25 © Valmet |
Extensive set of engineering features
Engineering and Maintenance Tools

 Scalable multiuser environment  State of the art network design,


for concurrent engineering hw-engineering and
 DNA Explorer – one documentation tool DNA Network
configuration and maintenance Designer
tool for control applications, field  Point and click operation for all
bus, field devices and network tasks: edit, online, check etc.
document management Efficient bulk data handling
 Uniform configuration for all field
interfaces
 WYSIWYG Graphical User
Interface design tool
 Integrated testing environment

26 © Valmet |
Valmet DNA diagnostic
Operation, Maintenance, Reporting,
Reporting Enterprise integration

Expert services

Firewall

Diagnostic from all levels:


 Network devices
Engineering
and
Maintenance
 System bus
 System nodes
 IO groups / units
 Field devices

27 © Valmet |
Valmet DNA diagnostic
System nodes – from Valmet DNA Operate

 Automatic system node


diagnostic displays:
– Redundant ACN
– Network, version, HW,
redundancy and field bus
information
– IO group statuses

Field buses 3 and 4 ACN IO


Field bus 5 – centralized rack
IO

28 © Valmet |
Extensive set of engineering features
Engineering and Maintenance Tools

 Scalable multiuser environment  State of the art network design,


for concurrent engineering hw-engineering and
 DNA Explorer – one documentation tool DNA Network
configuration and maintenance Designer
tool for control applications, field  Point and click operation for all
bus, field devices and network tasks: edit, online, check etc.
document management Efficient bulk data handling
 Uniform configuration for all field
interfaces
 WYSIWYG Graphical User
Interface design tool
 Integrated testing environment

29 © Valmet |
Scalable engineering environment
Engineering Server & Clients
Office
 Scalable multiuser environment Engineering Engineering
for concurrent engineering Clients 0-n Clients 0-n
– One common server for all engineering
data
– Multiple clients

 Backup server to strore control


application and system software
for automation downloads
– Data backup for user changeable
parameters (setpoints, production
targets,…)
– Bumpless download

 Alternative/additional flash 1111U U


U
U
2U U

memory backup in process


211U U
122U U
U
12U U
211U U
U
122U U
U

- Engineering Server
12U

controller
1U U
U
122U
U
AC/DC-POWERSUPPLIES(2) 1U
4K
AKUU

- DNA Field Device Backup


condition monitoring(CM) Server

30 © Valmet |
Process picture editor
DNA Operate Editor

 Features:
– WYSIWYG (what you see is what
you get) picture design tool
– Extensive library of three
dimensional devices, tanks,
pipelines and other process
components.
– Part of the engineering toolset

31 © Valmet |
Application loading
Bumpless download

 Modular loading: add, replace


and update the objects you
selected
– One application module to one
controller
 Bumpless online does not disturb
process
 To real process or to Virtual
Valmet DNA for testing
 Opens directly from DNA
Explorer

32 © Valmet |
Valmet DNA internal time synchronizing

Clock messages
Process controller node Valmet DNA master clock node
synchronizes Valmet IO buses

 There is one master clock node for the  If master clock node is down, another
whole system and all subsystems. node will be as master clock node
 The master clock node can be a ACN  Each node (ACN, Windows PC or server)
process controller node or a Windows has NCU (network communication)
node. software, which handles also time
 Time of the master clock set, when synchronizing
system started the first time  Time synchronizing by clock messages
(every 30 s) from master clock node,
resolution 1.0 µs

33 © Valmet |
Valmet DNA external time synchronizing

Atomic clock GPS Satelite

GPS receiver
NTP time server

Valmet DNA master clock node

 GPS receiver/NTP (Network Time  Same NTP time server can be used for
Protocol) time server is connected to synchronizing other non-Valmet DNA
Valmet DNA Ethernet network systems also
 With NTP protocol the accuracy of time
synchronizing is about 200 ns

34 © Valmet |
Functional descriptions

 Functional description
– Tells how the loop works and shows
the interlocking information.
 Integrated to operator interface
 Benefits
– Problem solving
– Fast star up’s
– Learning

35 © Valmet |
Interlocking signals and functional descriptions

t
ir gh
use
o
M

The interlockings page


displays the state of the loop
and any interlocking
connections to other loops.
From interlockings can also
found loop that triggered the
first interlocking ( ).

36 © Valmet |
New interlocking concept
Turn interlocking logic application to DNA Operate status view

37 Date/Title/Author © Valmet |
New Interlocking concept

 Generate Interlocking status displays directly from intelocking


application
 Replaces old Web based interlocking displays generated via DNA
Help
 New Interlocking displays are available on DNA operate.
 No manual work for generation required.
– Displays will be generated automatically during application compilation
– Dowloaded to DNA Operate along other application
 Solution based on composite function blocks
 Requirements
– New templates for Interlocking applications (PID, MTR, MGVS)

38 Date/Title/Author © Valmet |
Valmet DNA nodes/terminology

Node name Function Hardware Software


DNA Operate Operator interface ACN PO or Windows & DNA
HP/DELL Operate operator
workstation interface sw.
Trend- and -Trend History and ACN AS or Windows server &
Event archive Alarm history database HP/DELL Server Information server
- “off the self” package Compact and tools sw.
Alarm Alarm handling ACN PO or Windows & Alarm
processor HP/DELL processor sw.
workstation
BU -Compiled application ACN PO or Windows & Back
packages HP/DELL node sw.
-System sw. for process workstation
controllers
-Run time parameters

39 © Valmet |
Valmet DNA nodes/terminology

Node name Function Hardware Software


Engineering -Engineering repository ACN AS or Windows server &
server -Engineering tools HP/DELL Server Engineering
Standard server/client sw.
Engineering -Engineering tools HP/DELL Windows &
client workstation or Engineering client
Laptop sw.
Information -Trend History and HP/DELL Server Windows server &
management Alarm history database Standard Information server
server -Reporting/analyze tools and tools sw.

Process -Process control ACN RT Real time operating


controller -Interfaces to I/O’s and ACN CS system & process
field buses ACN MR or controller sw.
- Interfaces to external ACN SR1
systems

40 © Valmet |
THANKYOU