Trommel Structure Comparison
Trommel Structure Comparison
Operating
parameters as PARTNERSHIPS IN PRACTICE
Inside Dia of Discharge Trunion Because of this, a transition piece is needed here to fit the
Dia. 980 mm
Liner trommel having an effective inner diameter of 1800mm
and a discharge trunnion liner inner diameter of 980mm
% of Solid/water 50/50
Circulating Load N.A
RPM 13.5 — 14
PH Value 5-7
Other Details N.A
Capacity of solid feed 540 TPH
www.tegaindustries.com/optiscreen 05/01/2024 2
PARTNERSHIPS IN PRACTICE
Trommel Structure wt. Comparison
Competitor’s Trommel structure Tega’s Trommel structure
Transition piece
Pin & Lug For 30MM THK PNL 364 0.15 54.6 Pin & Lug For 30MM THK PNL 364 0.15 54.6
946(L)x150(HT)X30MM(TH 946(L)x150(HT)X30MM(THK
Total spiral length(16083) 17 12 204 Total spiral length(16083) 17 12 204
K) )
Nut Bolt, Washer & other Nut Bolt, Washer & other
34 0.1 3.4 34 0.1 3.4
fixings fixings
RR Lining Wt. 89.09115317 RR Lining Wt. 224.9536423
Transition piece wt. Transition piece wt. 491.59688
Total wt. of the trommel 1242.475153 Total wt. of the trommel 2279.218642
Tega's trommel weight has nearly doubled due to the design requirements aligned with the operating parameters. Additionally, the rubber lining weight has increased
by more than 2.5 times owing to the increased surface area, and the lining thickness of 10mm.
01/05/2024 www.tegaindustries.com/optiscreen 3
PARTNERSHIPS IN PRACTICE
we assure that the left side structure going to fail under sudden failure because of the factor of safety just 1.12. which is less than the required
endurance limit of the material of the structure.
01/05/2024 www.tegaindustries.com/optiscreen 4
PARTNERSHIPS IN PRACTICE
Despite having approximately double the weight, the maximum deformation in Tega's structure is less than that in the left-side structure. This is because we
have utilized I-beams as the main members of the structure, as per the requirements validated through the given operating parameters, and it is safe to
operate.
01/05/2024 www.tegaindustries.com/optiscreen 5
PARTNERSHIPS IN PRACTICE
Conclusion:
In the case of a cantilever beam subjected to cyclic loading conditions, it is imperative to ensure that the maximum
stress does not exceed the endurance limit of the material. This validation is crucial to safeguard the structure
against fatigue failure, employing the concept of the S-N curve.
since the trommel functions akin to a cantilever beam mounted over the discharge side of the mill, we validate our
structure based on this concept.
If the stress surpasses the endurance limit of the material, it would entail risking sudden structural failure (Please
refer to slide no.3 for stress results comparison)
We have supplied over five thousand trommels globally and received positive feedback regarding the quality,
longevity, and lining of the structures.
01/05/2024 www.tegaindustries.com/optiscreen 6
Thank You