Week No. 3
Week No. 3
Systems(MEMS)
Week No. 3
MEMS Research Group- E&ME College
Application Domains and Working Methodology
2
Some Examples of Our Work
Test Microstructures for MEMS Reliability Microgripper for Single Cell Maniplation
22
Our Current Research Focus
(a) (b)
Our Current Research Focus
Micro/Nanotechnology in Robotic Surgery
In a recent research study “Global Nanotechnology Market Outlook 2024” by RANCO Business Consultancy Service,
the global nanotechnology market is expected to exceed USD 125 Billion by year 2024.
The global robotics technology market size was valued at $62.75 billion in 2019, and is projected to reach $189.36
billion by 2027
Capacitive tactile sensor consisting of 16 × 16 tactile cells for force measurement in robotic hand
Our Current Research Focus
Micro/Nanotechnology in Robotic Surgery
Piezoresistive MEMS based tactile sensor for stiffness characterization in robotic manipulation
Our Current Research Focus
Piezoelectric MEMS based tactile sensor for texture and shape recognition of the micro objects
Potential of MEMS Technology in Pakistan
Problem Identification
Lack of trained manpower in the
IC and MEMS design and
development
13
Potential of MEMS Technology in Pakistan
Demand for MEMS in Local Industry
semiconductor
Review of Essential Electrical and Mechanical Concepts
Stress and Strain
Newton’s Laws is that, for any stationary object, the vector sum of forces and
moment (torque) on the object and on any part of it must be zero.
semiconductor
Review of Essential Electrical and Mechanical Concepts
Flexural Beams in MEMS
A beam is a structure member subjected to lateral loads, that is, forces or
moments having their vectors perpendicular to the longitudinal axis.
Flexural beams are used in MEMS as spring support elements.
We have to calculate
o Bending of beam under simple loading conditions
o Analyzing the induced internal stresses
o Determining the resonant frequency
Review of Essential Electrical and Mechanical Concepts
Various Beams used in MEMS
Applications of Microcantiliver Based Sensors
Savran, C.A., Knudsen, S.M., Ellington, A.D. and Manalis, S.R., 2004. Micromechanical detection of proteins using aptamer-based receptor
molecules. Analytical chemistry, 76(11), pp.3194-3198.
Applications of Microcantiliver Based Sensors
Zheng, Fengjiao, Peixi Wang, Qingfeng Du, Yiping Chen, and Nan Liu. "Simultaneous and ultrasensitive detection of foodborne bacteria by
gold Nanoparticles-Amplified Microcantilever array biosensor." Frontiers in chemistry 7 (2019): 232.
Review of Essential Electrical and Mechanical Concepts
Longitudinal Strain under Pure Bending
o Normal Stress
Review of Essential Electrical and Mechanical Concepts
o Total Stress
Review of Essential Electrical and Mechanical Concepts
o Natural Frequency of Cantilever Beam (No applied force, only boundary conditions)
Review of Essential Electrical and Mechanical Concepts
o Natural Frequency of Cantilever Beam (No applied force, only boundary
conditions)
Review of Essential Electrical and Mechanical Concepts
o Modal Frequency of Cantilever Beam (Second Mode)
Review of Essential Electrical and Mechanical Concepts
o Modal Frequency of Cantilever Beam (Third Mode)
Review of Essential Electrical and Mechanical Concepts
o Modal Frequency of Cantilever Beam
Review of Essential Electrical and Mechanical Concepts
o Bending Analysis of a Cantilever Beam
semiconductor
Review of Essential Electrical and Mechanical Concepts
Stress and Strain
Shear Stress
Shear Strain
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
Emery, R. D., & Povirk, G. L. (2003). Tensile behavior of free-standing gold films. Part I. Coarse-
grained films. Acta Materialia, 51(7), 2067-2078.
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
Haque, M. A., & Saif, M. T. A. (2001). Microscale materials testing using MEMS actuators. Journal
of Microelectromechanical Systems, 10(1), 146-152.
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
Haque, M. A., & Saif, M. T. A. (2001). Microscale materials testing using MEMS actuators. Journal of
Microelectromechanical Systems, 10(1), 146-152.
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
Espinosa, H. D., Zhu, Y., & Moldovan, N. (2007). Design and operation of a MEMS-based material testing
system for nanomechanical characterization.Journal of Microelectromechanical Systems, 16(5), 1219-1231.
semiconductor
Material Properties in MEMS
Tensile Testing in MEMS
semiconductor
What kind of mechanical behaviour phenomena does one have to understand?
Phenomenologically mechanical behaviour can be understood as in the flow diagram
below.
Multiple mechanisms may be associated with these phenomena (e.g. creep can occur by
diffusion, grain boundary sliding etc.).
These phenomena may lead to the failure of a material.
Mechanical Behaviour
Note: above is a ‘broad’ classification for ‘convenience’. E.g. Creep is also leads to plastic deformation!
Review of Essential Electrical and Mechanical Concepts
Recoverable
Instantaneous
Elastic
Time dependent Anelasticity
Deformation
Instantaneous
Plastic
Permanent Time dependent
Viscoelasticity
Creep in Microstructures
• Time dependent accumulation of the plastic strain at high temperature and stress affects both the static
and dynamic response of the MEMS device.
• For the long term reliability of the MEMS devices especially for the space applications it is very
important to study the creep mechanism .
Creep in Microstructures
48
Creep in Microstructures
49
Creep in Microstructures
50
Case Study: Experimental Investigation of Creep in Gold RF
Microstructures Experimental Investigation of
Creep in Gold RF Microstructures
51
An RF MEMS Switch
52
Experimental Investigation of Creep in Gold RF Microstructures
•Samples designed ad-hoc for creep tests
•Electrostatic actuation
•Material: gold electroplated
•Typical configuration of microbridge based RF-MEMS switch
53
Experimental Investigation of Creep in Gold RF Microstructures
•Samples designed ad-hoc for creep tests
•Electrostatic actuation
•Material: gold electroplated
•Typical configuration of microbridge based RF-MEMS switch
54
Experimental Investigation of Creep in Gold RF Microstructures
•Specimens with different geometric dimensions were tested at different temperatures and
actuation voltages.
Plate Length Plate Width Beam Length Beam Width Number of Plate Thickness Beam Thickness
(lp) (wp) (lb) (wb) Hole Size (tp) (tb)
holes
55
Experimental Investigation of Creep in Gold RF Microstructures
•FEM modeling of thermal loading at 60 °C
z z
x y x y
(a) (b)
56
Experimental Investigation of Creep in Gold RF Microstructures
•FEM modeling of electrostatic actuation at 60 V
z z
x y x y
(a) (b)
57
MEMS Reliability; FEM Modelling and Experimental Characterization
Experimental Investigation of Creep in Gold RF Microstructures
•FEM modeling of BOTH thermal heating at 60 °C and electrostatic actuation at 60 V
z z
x y x y
(a) (b)
•Von- Mises stress is 104 Mpa
•Maximum upward deflection is 1.6 um
58
MEMS Reliability; FEM Modelling and Experimental Characterization
Experimental Investigation of Creep in Gold RF Microstructures
•Experimental Setup:
• Accumulation of the creep strain measured by monitoring central plate deflection.
• Constant stress is applied by potential difference between top and bottom plate.
• Constant temperature is provided by Peltier cell with a temperature sensor.
(Experimental Setup)
60
Experimental Investigation of Creep in Gold RF Microstructures
•Repeatability test: Specimens with same dimensions and on separate dies to avoid;
• Size effects
• Sequential heating effects
Almost one-fourth of
the creep strains are
plastic and permanent
strains.
61
Experimental Investigation of Creep in Gold RF Microstructures
62
Experimental Investigation of Creep in Gold RF Microstructures
•Effect of creep on dynamic response
Before creep test After creep test (f final/f initial)
natural frequency natural frequency
(kHz) (f initial) (kHz) (f final)
Specimen 7 33.4 32.4 0.97
Specimen 8 33.6 32.3 0.96
Specimen 9 32.9 30.5 0.93
•Natural frequency (w) depends on the mechanical stiffness which depends on the Young’s modulus and
geometric parameters.
Before creep test natural After creep test natural frequency (f final/f initial)
frequency kHz ((f initial) kHz ((f final)
3D FEM with 3D FEM with
Experimental nominal Experimental decreased Experimental 3D FEM
stiffness stiffness
Specimen 7 33.4 33 32.4 32.1 0.97 0.97
Specimen 8 33.6 33.1 32.3 31.7 0.96 0.96
Specimen 9 32.9 32.6 30.5 30.3 0.93 0.93
A decrease of 6, 8 and 14 % in the Young’s modulus for the specimen 7, 8 and 9 respectively 63
Experimental Investigation of Creep in Gold RF Microstructures
•Effect of creep on static response
Before creep test After creep test (Vpi final/Vpi initial) After creep test
pull-in voltage (V) pull-in voltage permanent measured
(Vpi initial) (V) (Vpi final) central plate deflection
(um)
Specimen 7 97 89 0.92 0.14
Specimen 8 98 88 0.90 0.15
Specimen 9 90 79 0.88 0.12
•Pull-in Voltage depends on both the mechanical stiffness (k) which depends on the Young’s modulus and central
plate deflection (dave) after creep test.
Before creep test pull-in voltage (V) After creep test pull-in voltage (V) (Vpi final/Vpi initial)
(Vpi initial) (Vpi final)
3D FEM with 3D FEM with
Experimental nominal Experimental measured Experimental 3D FEM
stiffness deflection only
Specimen 7 97 96 89 91.2 0.92 0.95
Specimen 8 98 96.2 88 91 0.90 0.94
Specimen 9 90 89.4 79 81.8 0.88 0.91
64
Experimental Investigation of Creep in Gold RF Microstructures
•Effect of creep on static response
Before creep test pull-in voltage (V) After creep test pull-in voltage (V) (Vpi final/Vpi initial)
(Vpi initial) (Vpi final)
3D FEM with
3D FEM with both measured
Experimental nominal Experimental deflection and Experimental 3D FEM
stiffness decreased
stiffness
Specimen 7 97 96 89 88 0.92 0.916
Specimen 8 98 96.2 88 88 0.90 0.914
Specimen 9 90 89.4 79 78.4 0.88 0.876
•The variation in the natural frequency values measured before and after the creep test is
explained with the permanent reduction in the mechanical stiffness.
•This decrease in the mechanical stiffness is also verified by comparing the pull-in voltage values
before and after the creep tests.
65
Experimental Investigation of Creep in Gold RF Microstructures
•Endurance Test under Repeated Loading
• One of the specimen is tested for creep endurance test under repeated loading.
• The specimen is tested by applying constant actuation voltage of 60V and temperature of 60°C for 24
hours and then allowing to relax for next 2 hours.
• Four consecutive cycles are applied.
66
Experimental Investigation of Creep in Gold RF Microstructures
•Endurance Test under Repeated Loading
67