Elective (1)
Storage Technologies:
Section 2
ICT Architecture
www.huawei.com
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved.
Data and Information
Processing Information
Data
Data Redundancy
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 2
Lifecycle Management of Information and
Data
5 Stages of the Lifecycle
of Information and Data Management:
1. Generation
2. Transmission
3. Usage
4. Maintenance
5. Fate (Store or Delete)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 3
New Industrial Revolution Requires New
ICT
Cloud Big Data Social IoT CPS Mobility
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 4
ICT is Migrating From Support System To
The Role of Production System
New Industrial Revolution
1980 - 1995 1995 - 2010 2010 - 2025
ICT Phase I ICT Phase II ICT Phase III
ICT Changes Business ICT Becomes The Core of
Office Automation
Flows. Production Systems.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 5
What is ICT ?
ICT is the abbreviation of Information, Communication and Technology. It is a new concept and
technological area formed from the combination of communication technology and information
technology.
Figure 1: Narrow Definition Theory: ICT is the Figure 2: Combination Theory: ICT is the union or
intersection of IT and CT (ICT=IT∩CT). combination of IT and CT (ICT=IT∪CT).
Figure 3: General IT Theory: CT is a part of the wider definition of IT(CT ⊆IT,ICT=IT ∪CT=IT).
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 6
Features of ICT
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 7
Business Driven ICT Architecture (1)
Business Driven Joint Innovation in Ecosystem
Drive Drive
Industrial Application
Business (e.g. ERP, CRM, Traffic Control
Enable Enable
Requirement System)
Enterprise Users Partners (GP, ISV, SI)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 8
Business Driven ICT Architecture (2)
Huawei Focused ICT Infrastructure
ICT Convergence
Capabilities Product Innovations
Network Cloud OS
Drive
Cloud Big Data Drives
Storage Big Data
Open API
(eSDK)
Enables
Enable Server Security
Social IoT
Enterprise
UC
Wireless
Mobility CPS
Huawei
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 9
Huawei Focuses on Converged ICT
Architecture of Cloud, Pipe and Device
Cloud:
DC2 + Big Data
IaaS/SaaS Distributed Cloud Data Center + Big Data
MES ERP PLM Software Defined, Hardware Reconstruction,
Business Driven, Data Innovation.
Service-driven - DC2
Pipe:
Low Latency, Multi Concurrent Reliable
Network
5G SDN
Leading 5G and Agile networks.
Smart Gateway Device:
Intelligent IoT
LTE-M.
Leading LTE-M2M.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 10
Common Components of ICT
Host
Basic
Storage
Switch Components
Array
of ICT
Network
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 11
Examples of ICT Components
Host Storage
Clients (PC, Tablet, Mobile etc.)
Switch Backup
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 12
Front View of the Basic Components of
ICT Infrastructure
Host Host
Switch Switch
Switch Network
Storage Array Storage Array
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 13
Rear View of the Basic Components of
ICT Infrastructure
Host Host
Switch Switch
Switch Network
Storage Array Storage Array
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 14
Common Forms of Storage Array
Components
Controller and Disk Chassis Separation
+ =
Independent External Disk
Controller Chassis Enclosures for Storage Array System
Expansion
Controller and Disk Chassis Integration
+ =
Controller Module Integrated Controller and Storage Array System
Disk Enclosure
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 15
Chassis with Controller and Disk
Separation
I/O Module Fan Module
Chassis
Power Module
Controller
BBU Module Module
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 16
2U 2.5” Disk Enclosure
2.5” Disk Module
No adapter
design
Support 6G SAS
/NL-SAS /6G
SAS SSD
Expansion Module
Dual Expansion
module
12 G SAS Uplink/
Downlink
600w Power Module
1 Serial Port 1+1 Redundancy
1 2 3
Fan Built-In Power Module (Each
2 Mini SAS HD Expansion Port Power Module has Built-In Fan )
Supports AC/DC current
3 Disk Enclosure ID Display
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 17
4U 3.5” High Density Disk Enclosure
75 disks installed in 5 rows
and 15 columns.
Single Disk
module can be hot
swappable.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 18
Supported Hard Disk Types
Disk Size: Ports:
• ATA/IDE
• 5.25 inch • SATA/NL SAS
• 3.5 inch • SCSI
• 2.5 inch • SAS
• 1.8 inch • FC
Medium • SSD Functions:
• Mechanical Hard Disk
Drive (HDD) Disk Types • Desktop Grade
• Enterprise Grade
• Solid State Drive(SDD)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 19
Components of a Hard Disk
Spindle
Disk Platter
(Motor and Bearing is
underneath)
Actuator
Read/Write Arm
Control Circuit
Board
Disk
Connector
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 20
Properties of a Hard Disk
Sector Track
Read/Write Head
Cylinder D Actuator
Arm
Disk Platter
Motor
Motor
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 21
SAS Drives
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 22
NL - SAS Drives
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 23
Solid State Drives (SSD)
As price lowers and storage capacity increases, SSD is becoming more and more
popular in the market.
SSD Principles:
Uses flash technology to store data.
No mechanical structure with lower energy consumption, low heat signature and low
noise.
Limited lifetime due to SSD usage frequency.
3 types of SSD:
SLC (Single Level Cell)
MLC (Multi Level Cell)
TLC (Triple Level Cell)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 24
SLC vs MLC vs TLC
SLC: Each cell stores only 1 bit of data: 0 or 1.
MLC: Each cell stores 2 bit of data : 00,01,10,11.
TLC: Each cell stores 3 bit of data: 000, 001, 010, 011,100,
101,110, and 111.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 25
SSD Architecture
SSD Hardware Architecture Principles
BBU SSD Architecture Diagram
BBU
Multi Parallel Paths
6Gbps SSD
SAS
SAS Connector
Connector
Controller FLASH
DDR
DDR RAM
RAM
No moving mechanical parts, high performance, low energy consumptions.
Multi parallel paths and within channel flash cell reuse sequence.
Supports TCQ/NCQ, responds to multiple IO requests at the same time.
Standard response time is lower than 0.1ms.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 26
Advantages of SSD Performance
Performance Advantages of SSD Technology
I/O I/O
IP/FC SAN
• Delayed by Track Seek
• Short Response Time.
Time.
• Mechanical • High Read/Write Efficiency.
Delay Time.
VS
Traditional HDD Storage System SSD Storage System
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 27
Key Performance Indicators of Hard Drives
Volume: Indicated in units of MB or GB. Storage Volume is affected by the volume
of a single disk platter and number of disk platters.
Rotational Speed: Indicated in Rotation Per Minute (RPM) of the disk platter.
Common drive RPM are 5400RPM/7200RPM, SCSI drives RPM can reach up to
10,000-15,000RPM.
Average Access Time: Equals to Average Track Seek Time + Average Waiting Time.
Data Transfer Rate: Refers to speed of Data Read/Write of the disk and indicated by
MB/s. It includes both internal and external data transmission rate indicators.
IOPS (Input/Output Per Second): Refers to input/output (read/write) count per
second, it is one of the key indicators of the hard drive performance.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 28
FC I/O Module
8Gb FC I/O module provides 4
8Gbits/s transmission rate FC ports.
16Gb FC I/O module provides 2
16Gbits/s transmission rate FC ports.
A B
8Gb FC High Density I/O module
provides 2 physical ports that can be
converted to 8 unit of 8Gb/s FC Optical
Ports.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 29
FC Switch
FC Switch
SFP/QSFP Optical Cables
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 30
Host Bus Adapter (HBA) Cards
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 31
Equipment Cables
1. FDR Cable. 2. Serial Cable.
3. Mini SAS HD Cable. 4. Optical Cable.
5. MPO-4*DLC Fiber Cable. 6. AOC Cable.
1 2 3
4 5 6
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 32
Thank You
www.huawei.com
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 33