AC PCB Checking Guidelines For Service
AC PCB Checking Guidelines For Service
AC PCB Checking Guidelines For Service
Part Code
Display Part Code
1100103950
PCB 1100111868
India dance series
Cooling & Heating/D panel/Z panel Cooling/Left –Right swing/D panel/Z panel
PCB Identification Code-0x1E6C3A PCB Identification Code-0x1DF999
Software Version code-23 Software Version code-21
WiFi CHIP
Part Code
Display Part Code Part Code
1100112846
PCB 1100112846 1100112999
PCB Component Identification Sheet
ERROR CODE-E1,E2
ERROR CODE-E1
ROOM
SENSOR CN5
ERROR CODE-E2
COIL
CN6
SENSOR
ERROR CODE-E4
CAUSES COUNTERMEASURES
3.TEMPERATURE CONTROL
Under cooling and dry modes if Te≤-2⁰C for consecutive 3min and the compressor
IT MAY BE BECAUSE OF EVAPORATING COIL SUCTION
continuously runs for 5 min or longer, the compressor will stop running while the
IS BLOCKED SO REMOVE BLOCKAGE OVER OF IT.
indoor fan continues to blow in the set fan speed ;if Te≥7⁰C, the protection will be
suspended
4.COMPRESSOR PROTECTION
If the following 3 conditions have been met for 1 hour and 45 min, the
compressor will stop running for 7 min while the fan keeps running at set fan
speed.
A)Compressor runs continuously
NO NEED TO WORRY
b)Indoor fan runs at low medium or ultra low fan speed
c)In case of room Tr<26⁰C,If compressor stops , the timing process starts again.
Note: If the fan runs at other speeds or room temp≥26⁰C,the timing will be
suspended; the timing process will continue if those conditions are met again;
and the cumulative time will be cleared in case of shutdown or mode conversion.
ERROR CODE-E5
2.INDOOR FAN MOTOR FAULTY REPLACE INDOOR FAN MOTOR WITH NEW ONE
IDU FAN
MOTOR
3.INDOOR FAN MOTOR JAM REPLACE INDOOR FAN MOTOR WITH NEW ONE
3.COIL SENSOR NOT PROPERLY INSERTED AT EVAPORATING COIL INSERT COIL SENSOR PROPERLY IN COIL PROPER FITMENT
HOLDER LOCATION SENSOR HOLDER OF COIL SENSOR
Self-inspection function
1. This function is used to test whether all input and output items on the main control PCB and the display PCB are normal.
2.Press the emergency button to supply power, a buzzer sounds once after 0.5 seconds and then it enters into the self-inspection mode:
3. In the process of self-inspection, if a fault occurs, it will report the fault and stop the self-inspection; in case of no fault,
the driving signals in two columns will be output in cycle and it will stop after 5 cycles.
PCB check process before removing for
replacement
5.Check relay for compressor & fan motor getting hot or chattering
8.Check programming pins of CN2 connector should not touch each other, If touching then
separate them apart
Programming pins
9.Check F1 fuse is properly fitted ,if not then properly fit it, it should touch fuse holder properly
i)whether there is soldering short on display connector CN9 ,if present then remove
that shorting
ii)Check whether any soldering short in IC1 IC is there, if present then remove it
IC1
How to run AC in worst condition
If compressor works in good condition you can run AC for half an hour by
commissioning mode
Commissioning: press the emergency button and hold it for 5s until the buzzer beeps twice, then the controller will enter commissioning
mode. Press down and hold the button for another 5s, commissioning will be stopped. The commissioning lasts 30min, and the cooling
mode icon will start blinking
a. During commissioning, the determination conditions for room temperature sensor will become ineffective, the compressor will start
normally after 3 minutes of protection (no 3min protection if initially powered), the indoor fan will blow at high speed, the machine will
work in cooling mode, and vertical swing angle will set to angle 3.
c. Press and hold emergency button for 5s, then the commissioning will be stopped.
d. The 7 segment displays (Tr) room temperature during commissioning, If the emergency button is pressed once while it is showing room
Temp, the 7 segment will display (Te)coil temp. ,and press again to show room temp(Tr)
1.Make inspection sheet ,mention model no., serial no. of PCB in addition to other component
data like Customer name, complaint no. etc.
3.Proper packing with foam poly bag/ bubble bag & carton to be used for sending factory analysis
4. If PCB not marked or not properly packed then factory cannot inspect that PCB properly.