Solvent Separation UNIT-06 - GOOD
Solvent Separation UNIT-06 - GOOD
Rafinate
Solvent
Feed
Extract
to Extract Settler
Extractor Pump
06PC-131~135
• Solvent extraction process is preferred over steam distillation process for
extraction of phenol because the water-phenol mixture forms azeotrope of 9.2
weight percent phenol.
• Solvent; DIPE, Di-Iso-Propyl-Ether.
As DIPE having preferential solubility to phenol and
immiscible with aqueous components, DIPE is
selected as solvent
• Operating pressure; 0.1 kg/cm2 g
• Operating temperature; 43 0C
• Capacity; 122 m3
• Max liquid level; 3600 mm
• Maximum filling rate; 310 m3/hr
• Make up is added in 1st extractor @ 1.19 kg/hr, 35 0C, 1.12 kg/cm2 a and
recovered solvent is added in 5th extractor.
Solvent Input Extractors: Solvent Output Extractors:
Make up 1.19 Kg/Hr Extract settler 40104.37 Kg/Hr
Solvent phenol slop receiver 2474.58 Kg/hr Raffinate after settler 4181.52 Kg/hr
Gas liquor from Vent gas scrubber Nil Extractor vents combine 545.02 kg/hr
Phenol column overhead condensate 3047.87 kg/hr 44831 kg/hr
Solvent column overhead settler 39307.27 kg/hr
44831 kg/hr
DIPE
A secondary ether used as a solvent
A Colourless liquid that is slightly soluble in water but miscible with most organic
solvents.
Tends to form explosive peroxides upon standing in air for long period.
Due to the secondary carbon next to the oxygen atom, which makes storage of DIPE
more dangerous.
The stored solvent should therefore be tested for the presence of peroxides more
often. (Once in every three months)
Molecular formulae; C6H14O
Density; 0.725 g/mol
BoilingPoint; 69 0C
06DM-104
EXTRACT SETTLER
N-73%
06LDT H-77%
-1076
L-72%
06DM-131
Extractor no-1 06DM-105
Extract Receiver
Capacity- 92 m3
N-92% 06LT- Op Press- 0.1 kg/cm2 g
H-96% 1075 Op temp- 43 oC
L-90% Density- 700/1032 kg/m3
06DM-106
Solvent Phenol Slop
Purge connection for N2
Nor-38%
06DM-104
Alm-91/86/26/23%
Extract Settler
LIC- HH- Activates shutdown
Capacity- 134 m3 1010 of entire extraction train.
Op Press- 0.1 kg/cm2 g LL- Trip 06PC-109
High level in drum boot
stops PC-109 to avoid Op temp- 43 oC
water carryover to Density- 700/1032 kg/m3
distillation column and LV-
CASCADE
1014 transferring slop from
solvent phenol slop to
extractor to avoid more LIC-
water coming from slop to SP-58% 1011
Alm-81/71/--/-- Solvent
extraction system.
06ES-103
Solvent distn colm recycle preheate
06DM-106
Solvent Phenol Slop 06FV-1046
06XV-1057
06LV-1011 06PC-109
SP- 61~79 m3/hr
Alm- --/86/39/--
06FIC-1046
Master flow controller of the whole phenosolvan and ammonia recovery unit.
Operated in auto mode only, once the plant is balanced and at >=80% normal
capacity in order to use FIC-1045 (Solvent return to extraction flow rate) on
manual/local set points for precisely establishing final desired solvent rate by
increasing the return by small increments.
Both FIC-1046 & 1045 are interlinked for not operating in auto mode.
Flow is cascaded to LIC-1010, i.e level controller in extract receiver.
Closed on reflux failure to 06VL-104 solvent distillation column, High level
in bottom of column.
Closed on high level of KO drum 06DM-101
06ES-103
SOLVENT DISTILATION COLUMN RECYCLE PREHEATER
Extract to
solvent distn colm Extract from extract
80 0C, 45645 kg/hr
receiver
43 0C, 45645 kg/hr
CTA from
153 0C
Phenol colm Bottom
Phenol cooler
70 0C
06VL-104/06DM-109
SOLVENT DISTn COLm/ PHENOL SURGE VESSEL
06ES-105
Solv dist colm condensor 75 0C
06PC-110
Solvent Reflux Pump
06VL-106
CWR Vent Gas
CWS Scrubber
06ES-105
60 0C
CWR
CWS
06ES-106
43 0C
06DM-107
SOLVENT COLm O/H SETTLER
06ES-106
Solv dist col cooler N-82%
06LDT
H-93%
-4301 L-10%
06DM-108
Solv col O/H receiver
Capacity- 69.3 m3
Op Press- 0.3 kg/cm2 g
Op temp- 43 oC
Density- 730 kg/m3
06DM-106
Solvent Phenol Slop
06DM-108
SOLVENT COLm O/H RECEIVER
06DM-107
Solv dist col O/H settler
Capacity- 69.3 m3
LIC-1098 SP- 61%
Op Press- 0.2 kg/cm2 g
Alm- --/85/7/4
Op temp- 43 oC
Density- 718 kg/m3