Eco Energy Solution

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 11

Vision, Mission & Motto Presentation for M&V Empanelment of

AEA Firm
VISION for
“Eco Energy Solution aspires to be a BEE – Accreditation Advisory
quality driven- customer centric firm. Committee
We strive to become one of the most By
dedicated & technically sound
Energy Audit firm to undertake PAT
ECO ENERGY SOLUTION
advisory services for MEA and M&V
as per BEE guidelines.”

MISSION
“We pledge to serve the Industry and Integrity Dynamism Innovation
Nation by developing Technical skills
and continually upgrading operating
practices towards saving Energy and VALUES
waste minimization.”
Quality Excellence
MOTTO
Value – Excellence, Dependability &
Quality
Motto – “Saving Heat & Power”
ECO ENERGY SOLUTION
General Approach For Energy Audit

Recommen
Deciding Monitoring
Verification dation and Energy
Scope of &analysis
of data of Cost Action Plan Audit
Energy of use of
Energy Use Benefit Report
Audit energy data
Analysis

 Assess team deployment / auditors/ engineers with required set of instruments.


 Determine offsite and on site days required to complete the study.
 Initiate site visit. Schedule Opening meeting. Define Objectives.
 Request - Equipment load list. Collect historic data - energy & production.
 Undertake measurements and data collection as per formats / test codes.
 Review & analyse collected data Vs rated performance / design values.
 Train Plant Personnel. Deviation & gap analysis.
 Recommendation for optimising energy consumption / improving performance
 Check Guidelines, Data authenticity.
 Scheduling closing meeting, Submitting action plan for implementation & monitoring to
sustain performance. Support for inviting offers, review technical specifications &
parameters.

ECO ENERGY SOLUTION


ECO ENERGY SOLUTION
• Monitor Actual Savings Realised M&V
• Review / Compare With Recommendations & Initial Estimation
• Follow up on Implementation Support.
Follow
• Extend OEM Vendor Support, if reqd. up
• Report Recommendation / Implementation Progress.
• Supervise Implementation, if reqd.
• Summarize Findings, Draft Discussions, Conclusions, Review Recommendations  
• Conduct closing meeting, Discuss Observations & Recommendations Reporting
• Data Compilation, Draft Report Preparation & Submission, Address Recommendations
• Submit Final Report With Management Response / Comments Included
• Conduct General Walk-through, Prepare Initial Plan, Discuss Procedures with Key Staff Field
• Conduct Test Work, Data collection as per Formats & Test Codes Work
• Communicate throughout on Audit Progress & Potential Findings
• Receive Formal PO / Commencement Letter, Hold Opening Meeting
• Review Audit Scope & Objective Planning
• Address & Management Inherent Concerns and Onsite Support
• Address Onsite & Offsite Mandays for Completing Agreed Scope incl Report
Methodology For Conduct of Energy Audit
Methodology Adopted For Conduct Of Energy Audit In
Electrical/Thermal - Process Specific Areas

Process Details & Flow Diagram


Historic Production & Energy Undertake Sample Test at
Study Process & Energy Input
Data Design Load

Energy & Mass Balance Flows


Data Collection for Sample
Prepare Typical HMBD Analyse Deviations, if any
Test

Measuring & Metering Sample Batch / Production


Logging Energy Detailed trials
Power metering Thermal Energy Recording Fuel /
Input Selected Energy
Electrical Loads Input Metering Steam Flows consumers
Parameters

Benchmark / Norms Fixation


Analyse Use, Trend, Analyse Variations in Compute Theoretical Compare Theo. Vs
& Benchmarking SEC Energy Requirement Actual Norms

Review Best Alternative Practices


Review Process Specific Review Tech-Eco feasibility
ENCON Opportunity
BAT’s for implementing BAT
ECO ENERGY SOLUTION
ECO ENERGY SOLUTION
• Reconfirm Option, Fix M&V Methodology Recom
• Define Scope, Financial & Non Fin, Benefits, mendati
• Financial Analysis on
• Present Recommendation for Approval
• Analyse Impact on Production & Energy Consumption
• Review Site Limitation, Tech - Eco Feasibility Implem
entation
• Strategise Implementation & Formulate Implementation Plan Strategy
• Affix Implementation Responsibility
• Mitigate Project Risks, if any
• Identify Alternative Approaches
• Gather Information about Each Alternative Options
• Review & Shortlist Select Option
• Review Continuous & Standby Demand
• Quantify Performance & Deviations, if any,
ENCON
• Identify ENCON Potential & Opportunity
• Analyse, Develop & Shortlist Options
Data
• Measure Onsite Operating Parameters for Time Period as per Codes
Acquisiti
• Review Design Specifications Vs Actual Operating Parameters, on
• Review Design Performance Curves, Basis of Selection
Approach Adopted In Making Recommendations
Monitoring of Action Plan / Recommendations

Review Evaluate &


Invite Procure &
recommend Assess M&V
Offers Implement
ations Options

1. Internal Audit 1. Weigh adv & dis-adv 1. Define Scope & 1. Followup with 1. Review new
2. Management of all options Tech. parameters Management for SEC &
Review 2. Assess life cycle 2. Invite offers from Purchase requisition Equipment
3. Training Required cost reputed / known 2. Co-ordinate Civil performance
4. Continual 3. Review Dynamics of experienced OEM works as reqd. 2. Review
Improvement process changes 3. Compare tech – eco3. Clear Site for projected Vs
5. Risk & 4. Evaluate Standby values installation Actual Savings
Environmental requirements 4. Review similar 4. Integrate Process 3. Quantify
Aspect 5. Review Variability installations, if any Operation with deviation in
Assessment with Process 5. Review Major installation operating
6. Stat. Compliance 6. Finalise payback /Critical Spare 5. Plan shutdown, if parameters, if
Evaluation period requirements reqd any
7. Review redundancy 6. Review ease of 6. Install I&C for proper
of existing asset replacement / monitoring of SEC
8. Mitigate Gaps if any Duplication

ECO ENERGY SOLUTION


Eco Energy Solution : Energy Audit Team
Sr. Name Qualification Total Experience Energy Sector Exp.
1 Mr. Pushkar Khanna B.E.-Chem. 26 yrs. Experience in Accredited Energy Auditor
Plant Energy Audits (AEA # 0260)
2 Mr. Krunal Shah D.E.E., 24 yrs. Experience in Lead Auditor, EMS
D.M.E. Energy Audits
3 Mr. P K Tripathi M.E. Mech. 35 yr Ex GM Bhilai Steel Iron & Steel Sector Expert
4 Mr. J B Sharma BSc, MII Ch > 45 yrs, Ex ED GACL Chlor Alkali Sector Expert
5 Dr. Yogesh Padiya PhD Chem 20 yr in Energy Audits Certified Energy Auditor
6 Mr. Umesh Mishra BE Mec,BoE > 30 yrs Power Sector Expert
7 Mr. Amol Chiplunkar Mtech Eg 10 yrs in Energy Audits Certified Energy Auditor
8 Mr. Rajendra Pandya B.E. Mech. 35 yrs. of Experience Rtd. Sr. Ex GEDA
9 Mr. Nikhil Mohite ME Mech 10 yrs. in Energy Audits Certified Energy Auditor
10 Mr. Samir Shah BE – I&C > 20 yrs Textile Sector Expert
11 Mr. K S Seetharaman Bsc (Spl) > 40 yrs Cement Sector Expert
12 Mr. Prashant Saxena BE > 33 yrs Cement Sector Expert
13 Mr. Uday Garge BE Elec 4 yrs in Energy Audits Field study measurements
14 Mr. Pradeep Thakur BE Elec 35 yrs in Energy Audits CEA, Bldgs & TPS

15 Mr. Vaibhav Tupe BE Elec 4 yrs in Energy Audits Field study measurements
ECO ENERGY SOLUTION
Power Sector Experience
Sr Plant / Station Capacity Location, Study
1 Hindustan Zinc ltd, 234 MW Coal CPP Detailed Energy Audit
2 Indrajeet Infra Ltd. 2 x 45 MW CPP Detailed Energy Audit
3 Essar Power ltd, Hazira 500 MW Gas CCGT Detailed Energy Audit
4 Pragati Power Corp. Ltd 330 MW Gas CCGT Mandatory Energy Audit
5 TATA Power Ltd. – Trombay 1250 MW Multi fuel PAT M&V Audit
6 CESC Ltd., Kolkata 3 x 250 MW + 2 x 67.5 Mandatory Energy Audit
7 Adani Udupi Power Corp. Ltd. 2 x 600 MW TPS, IPP Mandatory Energy Audit
9 Aryan Coal Ltd. 2 x 135 MW, TPS IPP Mandatory Energy Audit
10 ACB Ltd. Washery rejects 2 x 30 MW Mandatory Energy Audit
11 Spectrum Power Ltd 2 x 50 MW, IPP Mandatory Energy Audit
12 TATA Power CGPL Mundra. 5 x 830 MW TPS, IPP Mandatory Energy Audit
13 Hindalco Ind., Renusagar 10 x 80 MW CPP Mandatory Energy Audit
14 Maruti Clean Coal & Power 1 x 300 MW , Air Cooled Mandatory Energy Audit
Steel Sector Experience
Sr Plant / Station Capacity Year Location, Study
1 Uttam Galwa ltd Steel & Rolling Mill 2012 Detailed Energy Audit
2 Electrotherm ltd, Integrated Steel Plant 2015 Detailed Energy Audit
3 Nalwa Steel & Power Ltd Steel & Rolling Mill 2015 & Mandatory Energy Audit
2018
4 Mukand Ltd Steel Plant – SS & 2014 & Mandatory Energy Audit
2016
Alloy Steel
5 Shyam Sel & Power ltd Sponge Iron plant 2017 Mandatory Energy Audit
6 Adhunik Metaliks ltd Integrated Steel Plant 2015 Mandatory Energy Audit
7 Mahindra Eugene ltd Steel & Rolling Mill 2014 Detailed Energy Audit
8 SULB Steel, Bahrain Integrated Steel Plant 2015 Detailed Energy Audit
9 MSP Steel & Power Sponge Iron plant 2017 Mandatory Energy Audit
10 Essar Steel ltd, Hazira 10 Million Ton Plant 2018 Mandatory Energy Audit
11 African Foundries, Nigeria Rolling Mill 2018 Detailed Energy Audit
12 Sterlite Ind. Ltd Al Extrusion 2013 Detailed Energy Audit
13 Hindalco ltd Alumina 2018 Mandatory Energy Audit

ECO ENERGY SOLUTION


Textile & Cement Sector Experience
Sr Plant / Station Capacity Location, Study
1 LS Mills ltd Mandatory Energy Audit
2 Vaibhav Laxmi Ltd, Detailed Energy Audit
3 NTC Textile Mills Detailed Energy Audit

1 India Cements Ltd Detailed Energy Audit


2 Binani Cement Ltd Detailed Energy Audit
3 Chittoor Cement Ltd Detailed Energy Audit
(Lafarge/Nuvoco Cement)

ECO ENERGY SOLUTION


Inhouse Audit Instruments

Sr. No. Instrument List Model Make


1 3-Phase Power Analyzer-Unbalance Power ALM 31 Krykard
2 3-Phase Balance/1-Phase Power Analyzer-Clamp on Meter Nanovip-2 Elcontrol
3 Ultrasonic Flow Meter TR-600H ACORN
4 Flue Gas Analyzer & Digital Differential pressure meter 905 KANE
5 Pitot Tube L-Shape NEVCO
6 Non Contact InfraRed Thermometer Testo-805i Testo
7 Vane type Anemometer AM-4201 Lutron
8 Lux Meter 99 Kusum-Meco
9 Laser Distance Meter 414D Fluke
10 GPS Co-ordinator Garmin
11 Sling Physchrometer Zeal
12 Digital Non-Contact Tachometer DT2236 Lutron
13 Clamp On Meter 3150 MECO
14 Earth Tester WACO
15 Meggar DIT99E MECO
16 Contact Type Thermometer DTC-605 Digitek
17 Pressure gauge & Vacuum Gauges AL BAUMER

ECO ENERGY SOLUTION

You might also like