Alignment AIMIL 1
Alignment AIMIL 1
On
Machine Alignment
What is Alignment?
It is the correction of relative position of two
machines so that Center lines of two rotating shafts
form a straight line when the machines are working
at normal operating temperature.
Causes Of Misalignment
2. Angular
1. Rough Alignment
(a) Using straight edge
(b) Twin wire method
2. Precision Alignment
(a) Face & Rim
(b) Reverse indicator
Rough Alignment
Using straight edge
Rough Alignment
Using twin wire
Face & Rim Method
Face & Rim Method
Advantages:
1. Good for large dia. coupling hubs where the shafts are close together.
2. To be used where one of the shafts can not rotate during alignment.
3. Easy to use.
Disadvantages:
1. Difficult to take face readings, if there is axial float in the shaft.
2. Requires removal of coupling spool.
3. More complex alignment calculation.
Reverse Indicator Method
Reverse Indicator Method
Advantages:
1. More accurate than face & rim method.
2. Readings are not affected by axial float.
3. Possible to keep the coupling spool.
Disadvantages:
1. Both shafts have to be rotated.
2. Should not be used on close coupled shafts.
3. Difficult to take readings on long shaft.
Which Method To Be Used?
If L > D Reverse Indicator
L
D/2
Combination Method
Calculation can be
made for each of the
method to verify the
readings.
Alignment Tolerance
Off Set Angular
RPM mm mm / 100 mm
0000 - 1000 0.13 0.10
1000 - 2000 0.10 0.08
2000 - 3000 0.07 0.07
3000 - 4000 0.05 0.06
4000 - 5000 0.03 0.05
Disadvantages Of Dial
Indicator Method
Short Foot
Angled Foot
Tightening Of Holding Down Bolts
Fixing Of Dial Gauge
Perpendicular to
the coupling
surface.
Rules For Good Alignment
Clean the machine base. Remove rust burrs etc.
Use steel or brass shims.
Check indicator sag.
Check soft foot.
Check dial gauges before taking readings.
Use correct bolt tightening procedure.
Don’t lift the machine more than necessary.
Try to put the stem of dial gauge perpendicular to
the surface of coupling.
Use jack bolts.
Laser Alignment
Laser
Light Amplified By Stimulated Emission Of Radiation
+
Graphical representation
Example 1
Scale: Y-axis = 10:1
(Reverse Indicator Method) X-axis = 1: 5
SM Dial Reading: -1.50 mm
MM Dial Reading : +0.5 mm
Graphical representation
+
Graphical representation