Facade System
Facade System
process (from extraction to shipment) and by promenade. The selection of materials was an important part of the coats) at all locations
finish that replicates mold prepared and applied as
putting in place the highest quality and design process; concrete is one of the most common building materials per manufacturer’s
materials with the greatest specifications including
environmental policy requirements demanded used in sub-tropical commercial projects appropriate priming
precision. coat, preparation of
surface, etc. complete.
by ISO 9001 Quality and ISO 14001 On steel work
Environmental certifications
MS PERFORATED SHEET 1 1210 200 2,42,000 SQM
JASSIMAR SINGH
180BARCH034
CASE STUDY OF FAÇADE SYSTEM
SANDWICH WALL SYSTEMS SANDWICH WALL BI-MODULAR SYSTEMS THE VCW SYSTEM
The SANDWICH WALL Bi-Modular system allows the panels to use the
The SANDWICH WALL system features a vertical Omega profile
same joints in the horizontal and vertical directions and the four sides A ventilated curtain wall (VCW) is a facade system composed of multiple layers, in which the supporting external wall is provided with a facing that offers
joint with horizontal mounting edges for fixing wall panels
can be connected to each other so that the windows, doors and the shading protection against the weather. The facing can be made from a wide variety of materials: ceramic, metal, fibre cement, composite panels, natural stone
Features system can be combined with the wall organically: No fasteners are visible on etc. The substructure attaches this facing to the solid outer wall while leaving a gap between the two
• Prefabricated in factory, up to 1200mm x 12000mm. the
• According to the wall surface thermal insulation. building surface. It has high technical content and is beautiful and practical. Mechanism
requirements, the thickness is available in 50/75/100mm. Wind and thermal effects due to warming create a circulation of air in the ventilation space. This circulation transports away the moisture in the ventilation space
• High-density thermal insulation rock wool compound Features caused by diffusion of water vapour or driving rain. Separating the supporting and enclosing functions of the wall from the functions of weather protection and
presents high panel flatness and large strength. thermal insulation with an intermediate ventilation zone is a highly effective design in terms of physical aspects of the structure. Depending on the materials
• Prefabricated in factory, up to 1200mm x used, it can be employed in buildings of any height and any function.
• A variety of panel material options: aluminum alloy, stainless
12000mm.
steel, copper, titanium zinc alloy, etc.
• According to the wall surface thermal
• Thermally improved PVC joint profile and reduced thermal Anchoring Facade anchors approved by the building
insulation requirements, the thickness is
bridge effect for excellent overall thermal insulation. authorities must be used to anchor the VCW to the
available in 50/75/100mm.
• The installation structure and fasteners are completely supporting external wall. The optimum anchors are
• High-density thermal insulation rock wool
hidden, ensuring a uniform and aesthetically pleasing facade. selected for use in each project based on
compound presents high panel flatness and
• System installation seams can be customized according to considerations such as the materials used in the
large strength.
design requirements. construction of the supporting external wall and the
• A variety of panel material options: aluminum
• A wide variety of panel shapes allow for creating of curved prevailing loads. For VCWs, the most commonly used
alloy, stainless steel, copper, titanium zinc alloy,
surfaces, corners, etc. anchors are plastic anchors with galvanised screws
etc.
• Fire performance and curtain wall performance certification.
• Thermally improved PVC joint profile and
• Suitable for external walls or internal walls partitions
reduced thermal bridge effect for excellent nstallation: The insulation materials must be stored dry and
It is composed of an outer layer and an inner layer that are overall thermal insulation. then laid and joined together in a single layer on the
aluminium sheets, and intermediate layer that is high-density rock • The installation structure and fasteners are supporting wall. The insulation panels must be installed in
wool. completely hidden, ensuring a uniform and such a way that there is no gap between the surface of the
aesthetically pleasing facade. wall and the insulating layer. This ensures that no current of
• The system installation seam is 25mm. cold outdoor air can circulate behind the insulation. The
• A wide variety of panel shapes allow for joints between the insulation panels must be pushed firmly
creating of curved surfaces, corners, etc. together to ensure a tight seal. Connections to the
• Fire performance and curtain wall substructure, e.g. brackets, must be installed with no gaps.
performance certification. The fleece lamination must always be to the outside.
• Suitable for external walls or internal walls
partitions.
Above : Changchun Railway Above : Phase II of
Station, China Beijing Corning, China
Architect : The Third Architect : QunYu Design
Railway Survey and Design Consultancy Co., Ltd
Institute Group Corporation Product : Bi-Modular
(TSDI for short) Sandwich Wall Panel
Product : Sandwich Wall Façade
Panel
JASSIMAR SINGH
and intermediate layer that is high-
density rock wool.
180BARCH034