OMCR Operation Guide: Security Level: Internal

This document provides an overview and instructions for using the Operations and Maintenance Center Room (OMCR) system. It discusses the key components of OMCR including the M2000 platform and BSC6000 systems. It also outlines the routine tasks performed in OMCR such as modifying parameters, collecting data, monitoring alarms, and cooperating with drive tests. The document then delves into the specific functions and usage of the M2000 and BSC6000 systems for tasks like querying traffic statistics, alarms, and maintaining BTS equipment. It concludes with best practices for change management procedures when modifying network parameters through OMCR.

Uploaded by

Abdoulaye Abakar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views28 pages

OMCR Operation Guide: Security Level: Internal

This document provides an overview and instructions for using the Operations and Maintenance Center Room (OMCR) system. It discusses the key components of OMCR including the M2000 platform and BSC6000 systems. It also outlines the routine tasks performed in OMCR such as modifying parameters, collecting data, monitoring alarms, and cooperating with drive tests. The document then delves into the specific functions and usage of the M2000 and BSC6000 systems for tasks like querying traffic statistics, alarms, and maintaining BTS equipment. It concludes with best practices for change management procedures when modifying network parameters through OMCR.

Uploaded by

Abdoulaye Abakar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 28

Security Level: Internal

OMCR Operation Guide

Alex www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Agenda
• OMCR
• M2000
• BSC6000
• Principles in OMCR
OMCR Introduction
• Location of OMCR

M2000 Platform
• OM interface
• Traffic Stats (Excel) M2000 Nastar KPI
Platform Server Report
• Alarm (Excel)
OMCR
•… Intranet

...
BSC6000 BSC6000 BSC6000

BTS BTS BTS BTS BTS BTS BTS BTS BTS

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3


OMC Routine Task
• Modifying Parameters
• Collecting Data
 Data Configuration
 Traffic Statistics
 Signaling Trace
• Monitoring Alarms
• DT Cooperation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4


Agenda
• OMCR
• M2000
• BSC6000
• Principles in OMCR
M2000 Overview

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6


M2000-Log in BSC6000 LMT(on
line)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7


M2000-Query Traffic Statistics
Object Counter Other Get
Setting Setting Setting Results

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


M2000-Alarms
• Querying Current Fault Alarms
 Right Click on the site or BSC, and select Browse current Fault Alarms.
• Querying History Fault Alarms
 Right click on to the site or BSC, go to the Alarm Query > Query History
Fault Alarms.
• Querying Custom Alarms
 Select the shortcut Current Fault Alarm Query
 Configure parameters
 Object
 Alarm Level
 Alarm Type
 Alarm Status

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9


Alarms degrade KPIs

BSC Alarms BTS Alarms:


• MSC Overload • LAPD Alarm
• Cell Out of Service • Radio Link Prompt Alarm
• LAPD OML Fault • TRX Hardware alarm
• Lack TC Resource • TRX VSWR alarm
• LAPD Link Congestion • Main receive channel alarm
• … • Diversity receive channel alarm
• TRX communication alarm
• Clock Reference Abnormal Alarm
• E1 Remote Alarm /E1 Local Alarm
• Level 1 VSWR Alarm
• Level 2 VSWR Alarm
• …

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10


Agenda
• OMCR
• M2000
• BSC6000
• Principles in OMCR
BSC6000 O&M
LMT(GUI)
• Manage Data Configuration
• Manage BTS
• Signaling Trace
• Alarm Maintenance

MML(Script)
• Manage Data Configuration
• Manage BTS
• Alarm Maintenance

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12


LMT-Data Configuration
• Querying Data Configuration
• Modify Data Configuration
• Batch Modify Data Configuration
• Backup lmt.dat to Local PC
• Query Data Configuration in table

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13


LMT-BTS Maintenance(1)

• Level 3 reset: Based on the configuration data of the BTS


stored in the memory.
• Level 4 reset: Based on the data configuration stored in the
database (DB), the BSC updates the data stored in the
memory, and then configures the BTS again to reset it.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14


LMT-BTS Maintenance(2)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15


LMT-BTS Maintenance(3)

• One SDCCH has 8 sub-channels. One half rate TCH has 2 subchannels.
• The status of a channel is identified according to the color. You can put the mouse
point on a dot to view the status of a sub-channel.
• If a TRX number has a sign * on its upper right, the TRX is in mutual aid state.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 16


LMT-BTS Maintenance(4)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 17


LMT-BTS Maintenance(5)

Query the maximum and average values


of the main level and diversity level in a
frequency scan period.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 18


LMT-BTS Maintenance(6)

Manually set the network to maximum interference mode


to obtain the maximum interference of the entire
network. Testing idle timeslot refers to sending idle
Burst bit stream to the unseized timeslots to set the
network to maximum interference mode.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 19


LMT-Signaling Trace

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 20


MML Introduction

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 21


MML-Commands

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 22


MML-Batch Command(1)
• Generating Batch MML Command:
 Step1: generate one correct MML command.
 Step2: paste multiple lines in Ultra Edit.
 Step3: Using Column Mode to edit object
 Step4: Replacing spaces and Save.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 23


MML-Batch Command(2)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 24


Agenda
• OMCR
• M2000
• BSC6000
• Principles in OMCR
Principle in OMCR

• Follow the time schedule and rules for engineer to enter and leave OMC
room.
• Do not eat and drink in OMC room, and do not bring glasses into OMC
room.
• Different O&M clients use different user names and passwords. Usually
OMC room operators manage and distribute user names and passwords
to everyone, so do follow related rules when using them.
• Do not perform other operations except necessary RNP&O operations,
such as board reset and system parameter modification.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 26


CR Procedure
1. RNO engineers propose a request for modifying parameters, and sent it
to OMCR manager (customer or Huawei) for approval.
2. After OMCR managers approve it, RNO engineer send CR to OMC room
operators.
3. OMC room operators execute related modifying action. Do feed back the
modifying result to RNO engineers and OMCR manager by Email. If OMC
room operators fail to modify parameter, RNO engineers must analyze
the reason till the operation is close.
4. If parameters modification is just for temporary or testing, OMC
operators should restore the parameters after test.
5. Pay attention to parameter importance, parameter level, and parameter
impact on the system. Select the right time to avoid accidents. It is
strongly recommended to modify parameters at midnight.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 27