08 - BSC Integration To Rel4
08 - BSC Integration To Rel4
By the end of this module the trainee should be able to integrate a BSC in
the network (Rel.04), performing the following actions:
CCS7 definitions
Activate circuits
Activate SCCP
Activate BSSAP
MSS MGW
• Create signalling route. Use MGW as STP. • Create TDM based signalling link
• Allow activation of signalling route • Create signalling link set
• Activate signalling route • Create signalling route set
• Create remote SCCP and subsystem • Allow link activation
(BSSAP) • Activate link
• Activate remote SCCP • Allow signalling route activation
• Activate remote SCCP subsystem • Activate signalling route
NRI:NA0,320:;
NFJ:NA0,320:;
SUBSYSTEM STATES
NRI:NA0,320:;
NFJ:
MSS MGW
• Create location area • Create circuit group. Type is SPE
• Create BSC (special) and use by VMGW.
• Modify BSC. Define signalling system • Add circuits to circuit group. PCM in
information. CRCT must match with TERMID in
corresponding circuit group in MSS.
• Create circuit group. Type is ECCS and • Change state of circuits
user part is BSSAP.
• Attach termination identifiers to the circuit • Change state of circuit group
group. TERMID must match with CRCT • Attach MGW- BSC TDM to virtual MGW.
definitions of corresponding circuit group • Add existing and new circuit group
in MGW. otherwise existing replaced by the new.
• Create route VMGW status should be registration not
• Change circuit group state available and registration not allowed
before this command.
• Change termination id state
• Define route of circuit pool in BSC.
• Create BTS.
• Define BSC - BTS – LAC relationship.
• Unlock BSC
• Unlock BTS
For public use – IPR applies
11 © Nokia Siemens Networks Presentation / Author / Date / Document Number
BSC integration (Routing) in MSS
CGR data
RCI:SEA=3:CGR=320:PRINT=5:;
CIRCUIT GROUP(S)
FQDN : -
TRES1 : - TRES2 : -
DR1A : - DR2A : - ART1A : - ART2A : - ACTA : NO ACTION
DR1B : - DR2B : - ART1B : - ART2B : - ACTB : NO ACTION
DR1C : - DR2C : - ART1C : - ART2C : - ACTC : NO ACTION
CIRCUIT(S)
ROU TYPE OUTR STP TSG TMT SAT ATME DCME ECHO CONT TON SEQH ICR
320 EXT OMCG0 1 - - N N N N N UNK N N
CLISET NCLISET
0 DEFAULT
UPDR
-
FCL
-
RCI:SEA=3:CGR=320:PRINT=5:;
CIRCUIT GROUP(S)
ADDITIONAL PARAMETERS:
POOLID : 0
ECHO : NO
CIRCUIT(S)