Prosper® Tutorial 08: Modelling A Gas Well With Connected Pipeline
Prosper® Tutorial 08: Modelling A Gas Well With Connected Pipeline
How to perform a system calculation (VLP + IPR) to estimate the well flow rate for a
given WHFP.
Statement Of The Problem
In Tutorial 1, we have build a PROSPER model for a dry and wet gas well. The PROSPER file
that corresponds to this tutorial is Tutorial_01.OUT.
It is required to:
-Connect a 5000 ft long pipeline (ID = 6 inches) to the well only model created in tutorial 1
- Predict the flow rate if the pressure at the manifold is 350 psig.
Input Data
In Tutorial 1, we have build a PROSPER model for a dry an wet gas well. The
PROSPER file that corresponds to this tutorial is Tutorial_01.OUT.
It is strongly suggested to work trough the tutorial 1 first in order to gain familiarity with the
software.
Users already familiar with the software can simply recall the file "Tutorial_01.OUT" and
proceed with the current tutorial.
-Construct a PROSPER model for a producing an oil well with surface pipeline included.
- Use the PROSPER well model to estimate the flow rate against a manifold pressure of 350
psig.
- Step 1: Recall the file "Tutorial_01.OUT" and save it under a new name.
For this, select | System | Equipment | Surface Equipment and make the following changes:
One can read that the well would produce around 20 MMscf/d at a well head pressure of 395 psig.
Step by Step
In order to visualise the system plot, select | Plot | System Plot and this is the plot that
is generated: