PARTECH Report: Carla Felix Leanne Tan
PARTECH Report: Carla Felix Leanne Tan
PARTECH Report: Carla Felix Leanne Tan
Carla Felix
Leanne Tan
Contents of Report:
Gravity Sedimentation
Thickeners
Clarifiers
GRAVITY
SEDIMENTATION
Gravity Sedimentation
• Simple Gravity Settling Tank
Gravity Sedimentation
• Two Types of Classification
Equipment:
– Simple Gravity Settling Classifier
– Spitzkasten Gravity Settling Chamber
• Principle: The slower the settling
velocity, the farther it will travel.
Gravity Sedimentation
Simple Gravity Settling Classifier
Gravity Sedimentation
Spitzkasten Gravity Settling Chamber
Adjustable flow rates
between vessels to
change degree of
separation
Gravity Sedimentation Equipment
Corrugated Plate Separator (CPS)
Factors Affecting the Effectiveness
of Gravity Sedimentation
Floc which is too small or too large, is irregularly shaped, or has
a low density will not tend to settle out in the sedimentation
basin.
Disintegration of floc
Short circuiting
Temperature Differences
Disintegration of floc
sharp bends at the inlet high water velocity
Short circuiting
occurs when water bypasses the normal flow
path through the basin and reaches the outlet in
less than the normal detention time
Bridge-Supported Thickeners
Center-Column-Supported
Thickeners
Traction Thickeners
Bridge-Supported Thickeners
Give a denser and
Can transfer loads
Diameters up to 30 more consistent
to the tank
to 45 meters. underflow
peripherally.
concentration.
Fewer structural
Less complicated Access to drive
members subject
lifting device. from both ends.
to accumulation.
Mechanism is
20 meters or supported by a
more in diameter. single steel or
concrete column.
High installation
60 meters or
cost but low No lifting device
more in
maintenance can be used.
diameter.
cost.
Feed
Flocculant
Thickeners
Bridge Column
Type Type
Tunnel
Center-Column Piping
• Alternative to tunnel.
• Pump selection is important.
• Most common: bridge-mounted pump with suction line
through a wet or dry center column.
Types of Thickeners
High-Rate or
Conventional Thickeners
• The use of flocculant results to
a greater capacity
High-Density Thickeners
2. Ferric sulfate-Fe2(SO4)3
3. Ferric chloride-FeCl3
4. Sodium aluminate-Na2AI204
Coagulation
The positive charge
of the metals serves The metal salts also
to neutralize the form insoluble metal
negative charges on hydroxides
the turbidity particles
All chemical reactions are more rapid and more nearly complete, and
flocculation is improved.
The mixture passes out of the contacting and reaction well into the
clarification area, where the flocculated particles settle out.
Settling Zone
Outlet Zone
Sludge Zone
Parts of a Clarifier
Parts of a Clarifier
Inlet Zone
Channel
Weirs